Normalized to: Jibben, P.
[1]
oai:arXiv.org:1802.04432 [pdf] - 1659707
Diagnosing the magnetic field structure of a coronal cavity observed
during the 2017 total solar eclipse
Chen, Yajie;
Tian, Hui;
Su, Yingna;
Qu, Zhongquan;
Deng, Linhua;
Jibben, Patricia R.;
Yang, Zihao;
Zhang, Jingwen;
Samanta, Tanmoy;
He, Jiansen;
Wang, Linghua;
Zhu, Yingjie;
Zhong, Yue;
Liang, Yu
Submitted: 2018-02-12
We present an investigation of a coronal cavity observed above the western
limb in the coronal red line Fe X 6374 {\AA} using a telescope of Peking
University and in the green line Fe XIV 5303 {\AA} using a telescope of Yunnan
Observatories, Chinese Academy of Sciences during the total solar eclipse on
2017 August 21. A series of magnetic field models are constructed based on the
magnetograms taken by the Helioseismic and Magnetic Imager onboard the Solar
Dynamics Observatory (SDO) one week before the eclipse. The model field lines
are then compared with coronal structures seen in images taken by the
Atmospheric Imaging Assembly on board SDO and in our coronal red line images.
The best-fit model consists of a flux rope with a twist angle of 3.1$\pi$,
which is consistent with the most probable value of the total twist angle of
interplanetary flux ropes observed at 1 AU. Linear polarization of the Fe XIII
10747 {\AA} line calculated from this model shows a "lagomorphic" signature
that is also observed by the Coronal Multichannel Polarimeter of the High
Altitude Observatory. We also find a ring-shaped structure in the line-of-sight
velocity of Fe XIII 10747 {\AA}, which implies hot plasma flows along a helical
magnetic field structure, in the cavity. These results suggest that the
magnetic structure of the cavity is a highly twisted flux rope, which may erupt
eventually. The temperature structure of the cavity has also been investigated
using the intensity ratio of Fe XIII 10747 {\AA} and Fe X 6374 {\AA}.
[2]
oai:arXiv.org:1607.06697 [pdf] - 1494769
X-Raying the Dark Side of Venus - Scatter from Venus Magnetotail?
Submitted: 2016-07-22
This work analyzes the X-ray, EUV and UV emission apparently coming from the
Earth-facing (dark) side of Venus as observed with Hinode/XRT and SDO/AIA
during a transit across the solar disk occurred in 2012. We have measured
significant X-Ray, EUV and UV flux from Venus dark side. As a check we have
also analyzed a Mercury transit across the solar disk, observed with Hinode/XRT
in 2006. We have used the latest version of the Hinode/XRT Point Spread
Function (PSF) to deconvolve Venus and Mercury X-ray images, in order to remove
possible instrumental scattering. Even after deconvolution, the flux from Venus
shadow remains significant while in the case of Mercury it becomes negligible.
Since stray-light contamination affects the XRT Ti-poly filter data from the
Venus transit in 2012, we performed the same analysis with XRT Al-mesh filter
data, which is not affected by the light leak. Even the Al-mesh filter data
show residual flux. We have also found significant EUV (304 A, 193 A, 335 A)
and UV (1700 A) flux in Venus shadow, as measured with SDO/AIA. The EUV
emission from Venus dark side is reduced when appropriate deconvolution methods
are applied; the emission remains significant, however. The light curves of the
average flux of the shadow in the X-ray, EUV, and UV bands appear different as
Venus crosses the solar disk, but in any of them the flux is, at any time,
approximately proportional to the average flux in a ring surrounding Venus, and
therefore proportional to the average flux of the solar regions around Venus
obscuring disk line of sight. The proportionality factor depends on the band.
This phenomenon has no clear origin; we suggest it may be due to scatter
occurring in the very long magnetotail of Venus.
[3]
oai:arXiv.org:1506.06078 [pdf] - 1245886
Prominence Visibility in Hinode/XRT images
Submitted: 2015-06-19
In this paper we study the soft X-ray (SXR) signatures of one particular
prominence. The X-ray observations used here were made by the Hinode/XRT
instrument using two different filters. Both of them have a pronounced peak of
the response function around 10 A. One of them has a secondary smaller peak
around 170 A, which leads to a contamination of SXR images. The observed
darkening in both of these filters has a very large vertical extension. The
position and shape of the darkening corresponds nicely with the prominence
structure seen in SDO/AIA images. First we have investigated the possibility
that the darkening is caused by X-ray absorption. But detailed calculations of
the optical thickness in this spectral range show clearly that this effect is
completely negligible. Therefore the alternative is the presence of an extended
region with a large emissivity deficit which can be caused by the presence of
cool prominence plasmas within otherwise hot corona. To reproduce the observed
darkening one needs a very large extension along the line-of-sight of the
region amounting to around 10$^5$ km. We interpret this region as the
prominence spine, which is also consistent with SDO/AIA observations in EUV.