Normalized to: Jahn, W.
[1]
oai:arXiv.org:1807.02172 [pdf] - 1711615
Curved detectors developments and characterization: application to
astronomical instruments
Lombardo, Simona;
Behaghel, Thibault;
Chambion, Bertrand;
Jahn, Wilfried;
Hugot, Emmanuel;
Muslimov, Eduard;
Roulet, Melanie;
Ferrari, Marc;
Gaschet, Christophe;
Caplet, Stéphane;
Henry, David
Submitted: 2018-07-05
Many astronomical optical systems have the disadvantage of generating curved
focal planes requiring flattening optical elements to project the corrected
image on flat detectors. The use of these designs in combination with a
classical flat sensor implies an overall degradation of throughput and system
performances to obtain the proper corrected image. With the recent development
of curved sensor this can be avoided. This new technology has been gathering
more and more attention from a very broad community, as the potential
applications are multiple: from low-cost commercial to high impact scientific
systems, to mass-market and on board cameras, defense and security, and
astronomical community. We describe here the first concave curved CMOS detector
developed within a collaboration between CNRS- LAM and CEA-LETI. This
fully-functional detector 20 Mpix (CMOSIS CMV20000) has been curved down to a
radius of Rc = 150 mm over a size of 24x32 mm^2 . We present here the
methodology adopted for its characterization and describe in detail all the
results obtained. We also discuss the main components of noise, such as the
readout noise, the fixed pattern noise and the dark current. Finally we provide
a comparison with the flat version of the same sensor in order to establish the
impact of the curving process on the main characteristics of the sensor.
[2]
oai:arXiv.org:1805.09069 [pdf] - 1688203
Curved detectors for wide field imaging systems: impact on tolerance
analysis
Muslimov, Eduard;
Hugot, Emmanuel;
Lombardo, Simona;
Roulet, Melanie;
Behaghel, Thibault;
Ferrari, Marc;
Jahn, Wilfried;
Gaschet, Christophe;
Chambion, Bertrand;
Henry, David
Submitted: 2018-05-23
In the present paper we consider quantitative estimation of the tolerances
widening in optical systems with curved detectors. The gain in image quality
allows to loosen the margins for manufacturing and assembling errors. On
another hand, the requirements for the detector shape and positioning become
more tight. We demonstrate both of the effects on example of two optical
designs. The first one is a rotationally-symmetrical lens with focal length of
25 mm, f-ratio of 3.5 and field of view equal to 72$^\circ$, working in the
visible domain. The second design is a three-mirror anastigmat telescope with
focal length of 250 mm, f-ratio of 2.0 and field of view equal to $4^\circ
\times 4^\circ$. In both of the cases use of curved detectors allow to increase
the image quality and substantially decrease the requirements for manufacturing
precision
[3]
oai:arXiv.org:1805.09071 [pdf] - 1688204
Advanced optical designs of curved detectors-based two-mirrors
unobscured telescopes
Submitted: 2018-05-23
In the present paper we consider a family of unobscured telescope designs
with curved detectors. They are based on classical two-mirror schemes --
Ritchey-Chretien, Gregorian and Couder telescopes. It is shown that all the
designs provide nearly diffraction limited image quality in the visible domain
for $.4^\circ \times .4^\circ$ field of view with the f-number of 7. We also
provide a brief ghost analysis and point on special features of the systems
with curved detectors. Finally, the detector surface shape obtained in each
case is analyzed and its' technological feasibility is demonstrated.
[4]
oai:arXiv.org:1710.08776 [pdf] - 1686650
A fast, wide-field and distortion-free telescope with curved detectors
for surveys at ultra-low surface brightness
Submitted: 2017-10-24, last modified: 2017-10-25
We present the design of an all-reflective, bi-folded Schmidt telescope aimed
at surveys of extended astronomical objects with extremely-low surface
brightness. The design leads to a high image quality without any diffracting
spider, along with a large aperture and field of view, with a small central
obstruction which barely alters the PSF. As an example, we present the design
of a high-quality, 36 cm diameter, fast ( f /2.5) telescope working in the
visible with a large field of view (1.6{\deg}x 2.6{\deg}). The telescope can
operate with a curved detector (or with a flat detector with a field flattener)
and a set of filters. The entrance mirror is anamorphic and replaces the
classical Schmidt entrance corrector plate. We show that this anamorphic
primary mirror can be manufactured through stress polishing, avoiding high
spatial frequency errors, and tested with a simple interferometer scheme. This
prototype is intended to serve as a fast-track scientific and technological
pathfinder for the future space-based MESSIER mission.
[5]
oai:arXiv.org:1706.05520 [pdf] - 1584827
Combining freeform optics and curved detectors for wide field imaging: a
polynomial approach over squared aperture
Submitted: 2017-06-17
In the recent years a significant progress was achieved in the field of
design and fabrication of optical systems based on freeform optical surfaces.
They provide a possibility to build fast, wide-angle and high-resolution
systems, which are very compact and free of obscuration. However, the field of
freeform surfaces design techniques still remains underexplored. In the present
paper we use the mathematical apparatus of orthogonal polynomials defined over
a square aperture, which was developed before for the tasks of wavefront
reconstruction, to describe shape of a mirror surface. Two cases, namely
Legendre polynomials and generalization of the Zernike polynomials on a square,
are considered. The potential advantages of these polynomials sets are
demonstrated on example of a three-mirror unobscured telescope with F/#=2.5 and
FoV=7.2x7.2{\deg}. In addition, we discuss possibility of use of curved
detectors in such a design.
[6]
oai:arXiv.org:1607.06272 [pdf] - 1531078
Flexible focal plane arrays for UVOIR wide field instrumentation
Hugot, Emmanuel;
Jahn, Wilfried;
Chambion, Bertrand;
Moulin, Gaid;
Nikitushkina, Liubov;
Gaschet, Christophe;
Henry, David;
Getin, Stéphane;
Ferrari, Marc;
Gaeremynck, Yann
Submitted: 2016-07-21
LAM and CEA-LETI are developing the technology of deformable detectors, for
UV, VIS or NIR applications. Such breakthrough devices will be a revolution for
future wide field imagers and spectrographs, firstly by improving the image
quality with better off-axis sharpness, resolution, brightness while scaling
down the optical system, secondly by overcoming the manufacturing issues
identified so far and by offering a flexibility and versatility in optical
design. The technology of curved detectors can benefit of the developments of
active and deformable structures, to provide a flexibility and a fine tuning of
the detectors curvature by thinning down the substrate without modifying the
fabrication process of the active pixels. We present studies done so far on
optical design improvements, the technological demonstrators we developed and
their performances as well as the future five-years roadmap for these
developments.