Normalized to: Jacobsen, B.
[1]
oai:arXiv.org:astro-ph/0204437 [pdf] - 48982
An Optical Ultra-High-Resolution Cross-dispersed Echelle Spectrograph
with Adaptive Optics
Submitted: 2002-04-26
A prototype cross-dispersed optical echelle spectrograph of very high
resolution has been designed and built at Steward Observatory and tested at the
Starfire Optical Range (SOR) 1.5 m telescope. It is the first spectrograph to
take advantage of diffraction-limited images provided by adaptive optics in
order to achieve a potential resolving power of $R \sim 600,000$. The
wavelength coverage in a single exposure is about 300 \AA, which is
approximately 100 times that of conventional spectrographs operating at
comparable resolution. This was achieved by recording 60 cross-dispersed orders
across the $18\times 18$ mm$^2$ area of the CCD detector. The total efficiency
of the system, including the sky and telescope transmission, spectrograph and
CCD detector, is measured to be 1.3% at peak, much higher than that of other
ultra-high-resolution spectrographs. Sample stellar spectra with $R \sim
250,000$ are presented.
[2]
oai:arXiv.org:astro-ph/9708275 [pdf] - 98453
Mesosphere Sodium Column Density and the Sodium Laser Guide Star
Brightness
Ge, Jian;
Angel, J. R. P.;
Jacobsen, B. D.;
Roberts, T.;
Martinez, T.;
Livingston, W.;
McLeod, B.;
Lloyd-Hart, M.;
McGuire, P.;
Noyes, R.
Submitted: 1997-08-29
The first time simultaneous measurements of sodium column density and the
absolute flux from a sodium laser guide star, created by a monochromatic 3 W cw
laser, tuned to the peak of the sodium D2 hyperfine structure, were conducted
at the MMT and CFA 60 inch telescope in 1997. The results show that linearly
and circularly polarized laser returns are proportional to the simultaneous
sodium column density. Moreover, circularly polarized laser provides about 30%
increase in fluorescent return over linearly polarized laser. A laser guide
star with R = 10.3 mag. or absolute flux of 8.4x10^5 photons/s/m^2, could be
formed from a 1 watt projected circularly polarized sodium laser beam when
sodium layer abundance N(Na) = 3.7x10^9 /cm^2. Together with the distributed
column density measurements (e.g. seasonal and diurnal variations), we can
project laser power requirements for any specified guide star brightness.
The mesosphere sodium column density variation was measured above Tucson sky
throughout the year, through sodium absorption line measurements in stellar and
solar spectra. Previous measurements, e.g. Papen et al, 1996, have not been
made at this latitude (32 degrees). Further, our absorption method is more
direct and may be more accurate than the lidar methods normally used. The
seasonal variation amplitude is smaller than that at higher latitudes. While
the annual mean sodium column density tends to be lower than at higher
latitudes. Diurnal sodium column density tends to vary by as much as a factor
of two within an hour.
[3]
oai:arXiv.org:astro-ph/9607146 [pdf] - 95088
An Optical Ultrahigh Resolution Spectrograph for Use with Adaptive
Optics
Submitted: 1996-07-29
A prototype ultrahigh resolution spectrograph has been built with an adaptive
optics telescope. It provides $250,000$ resolving power, 300 \AA\ wavelength
coverage and 0.8\% efficiency.