Normalized to: Järvinen, A.
[1]
oai:arXiv.org:2002.08690 [pdf] - 2072705
High-resolution spectroscopy and spectropolarimetry of the total lunar
eclipse January 2019
Submitted: 2020-02-20
Observations of the Earthshine off the Moon allow for the unique opportunity
to measure the large-scale Earth atmosphere. Another opportunity is realized
during a total lunar eclipse which, if seen from the Moon, is like a transit of
the Earth in front of the Sun. We thus aim at transmission spectroscopy of an
Earth transit by tracing the solar spectrum during the total lunar eclipse of
January 21, 2019. Time series spectra of the Tycho crater were taken with the
Potsdam Echelle Polarimetric and Spectroscopic Instrument (PEPSI) at the Large
Binocular Telescope (LBT) in its polarimetric mode in Stokes IQUV at a spectral
resolution of 130000 (0.06 \AA). In particular, the spectra cover the red parts
of the optical spectrum between 7419-9067 \AA . The spectrograph's exposure
meter was used to obtain a light curve of the lunar eclipse. The brightness of
the Moon dimmed by 10.75 mag during umbral eclipse. We found both branches of
the O$_2$ A-band almost completely saturated as well as a strong increase of
H$_2$O absorption during totality. The deep penumbral spectra show significant
excess absorption from the NaI 5890 \AA doublet, the CaII infrared triplet
around 8600 \AA, and the KI line at 7699 \AA in addition to several
hyper-fine-structure lines of MnI and even from BaII. The detections of the
latter two elements are likely due to an untypical solar center-to-limb effect
rather than Earth's atmosphere. The absorption in CaII and KI remained visible
throughout umbral eclipse. A small continuum polarization of the O$_2$ A-band
of 0.12\% during umbral eclipse was detected at 6.3$\sigma$. No line
polarization of the O$_2$ A-band, or any other spectral-line feature, is
detected outside nor inside eclipse. It places an upper limit of $\approx$0.2\%
on the degree of line polarization during transmission through Earth's
atmosphere and magnetosphere.
[2]
oai:arXiv.org:1511.09281 [pdf] - 1374191
Comparing modal noise and FRD of circular and non-circular cross-
section fibres
Submitted: 2015-11-30
Modal noise is a common source of noise introduced to the measurements by
optical fibres and is particularly important for fibre-fed spectroscopic
instruments, especially for high-resolution measurements. This noise source can
limit the signal-to-noise ratio and jeopardize photon-noise limited data. The
subject of the present work is to compare measurements of modal noise and
focal-ratio degradation (FRD) for several commonly-used fibres. We study the
influence of a simple mechanical scrambling method (excenter) on both FRD and
modal noise. Measurements are performed with circular and octagonal fibres from
Polymicro Technology (FBP-Series) with diameters of 100, 200 and 300 {\mu}m and
for square and rectangular fibres from CeramOptec, among others. FRD
measurements for the same sample of fibres are performed as a function of
wavelength. Furthermore, we replaced the circular fibre of the
STELLA-echelle-spectrograph (SES) in Tenerife with an octagonal and found a SNR
increase by a factor of 1.6 at 678 nm. It is shown in the laboratory that an
excenter with a large amplitude and low frequency will not influence the FRD
but will reduce modal noise rather effectively by up to 180%.
[3]
oai:arXiv.org:1505.06492 [pdf] - 1056016
PEPSI: The high-resolution echelle spectrograph and polarimeter for the
Large Binocular Telescope
Strassmeier, K. G.;
Ilyin, I.;
Järvinen, A.;
Weber, M.;
Woche, M.;
Barnes, S. I.;
Bauer, S. -M.;
Beckert, E.;
Bittner, W.;
Bredthauer, R.;
Carroll, T. A.;
Denker, C.;
Dionies, F.;
DiVarano, I.;
Döscher, D.;
Fechner, T.;
Feuerstein, D.;
Granzer, T.;
Hahn, T.;
Harnisch, G.;
Hofmann, A.;
Lesser, M.;
Paschke, J.;
Pankratow, S.;
Plank, V.;
Plüschke, D.;
Popow, E.;
Sablowski, D.;
Storm, J.
Submitted: 2015-05-24
PEPSI is the bench-mounted, two-arm, fibre-fed and stabilized Potsdam Echelle
Polarimetric and Spectroscopic Instrument for the 2x8.4 m Large Binocular
Telescope (LBT). Three spectral resolutions of either 43 000, 120 000 or 270
000 can cover the entire optical/red wavelength range from 383 to 907 nm in
three exposures. Two 10.3kx10.3k CCDs with 9-{\mu}m pixels and peak quantum
efficiencies of 96 % record a total of 92 echelle orders. We introduce a new
variant of a wave-guide image slicer with 3, 5, and 7 slices and peak
efficiencies between 96 %. A total of six cross dispersers cover the six
wavelength settings of the spectrograph, two of them always simultaneously.
These are made of a VPH-grating sandwiched by two prisms. The peak efficiency
of the system, including the telescope, is 15% at 650 nm, and still 11% and 10%
at 390 nm and 900 nm, respectively. In combination with the 110 m2
light-collecting capability of the LBT, we expect a limiting magnitude of 20th
mag in V in the low-resolution mode. The R=120 000 mode can also be used with
two, dual-beam Stokes IQUV polarimeters. The 270 000-mode is made possible with
the 7-slice image slicer and a 100- {\mu}m fibre through a projected sky
aperture of 0.74", comparable to the median seeing of the LBT site. The
43000-mode with 12-pixel sampling per resolution element is our bad seeing or
faint-object mode. Any of the three resolution modes can either be used with
sky fibers for simultaneous sky exposures or with light from a stabilized
Fabry-Perot etalon for ultra-precise radial velocities. CCD-image processing is
performed with the dedicated data-reduction and analysis package PEPSI-S4S. A
solar feed makes use of PEPSI during day time and a 500-m feed from the 1.8 m
VATT can be used when the LBT is busy otherwise. In this paper, we present the
basic instrument design, its realization, and its characteristics.