sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Ishitsuka, H.

Normalized to: Ishitsuka, H.

4 article(s) in total. 286 co-authors, from 1 to 3 common article(s). Median position in authors list is 9,0.

[1]  oai:arXiv.org:1712.00148  [pdf] - 2127370
Construction of KAGRA: an Underground Gravitational Wave Observatory
Akutsu, T.; Ando, M.; Araki, S.; Araya, A.; Arima, T.; Aritomi, N.; Asada, H.; Aso, Y.; Atsuta, S.; Awai, K.; Baiotti, L.; Barton, M. A.; Chen, D.; Cho, K.; Craig, K.; DeSalvo, R.; Doi, K.; Eda, K.; Enomoto, Y.; Flaminio, R.; Fujibayashi, S.; Fujii, Y.; Fujimoto, M. -K.; Fukushima, M.; Furuhata, T.; Hagiwara, A.; Haino, S.; Harita, S.; Hasegawa, K.; Hasegawa, M.; Hashino, K.; Hayama, K.; Hirata, N.; Hirose, E.; Ikenoue, B.; Inoue, Y.; Ioka, K.; Ishizaki, H.; Itoh, Y.; Jia, D.; Kagawa, T.; Kaji, T.; Kajita, T.; Kakizaki, M.; Kakuhata, H.; Kamiizumi, M.; Kanbara, S.; Kanda, N.; Kanemura, S.; Kaneyama, M.; Kasuya, J.; Kataoka, Y.; Kawaguchi, K.; Kawai, N.; Kawamura, S.; Kawazoe, F.; Kim, C.; Kim, J.; Kim, J. C.; Kim, W.; Kimura, N.; Kitaoka, Y.; Kobayashi, K.; Kojima, Y.; Kokeyama, K.; Komori, K.; Kotake, K.; Kubo, K.; Kumar, R.; Kume, T.; Kuroda, K.; Kuwahara, Y.; Lee, H. -K.; Lee, H. -W.; Lin, C. -Y.; Liu, Y.; Majorana, E.; Mano, S.; Marchio, M.; Matsui, T.; Matsumoto, N.; Matsushima, F.; Michimura, Y.; Mio, N.; Miyakawa, O.; Miyake, K.; Miyamoto, A.; Miyamoto, T.; Miyo, K.; Miyoki, S.; Morii, W.; Morisaki, S.; Moriwaki, Y.; Muraki, Y.; Murakoshi, M.; Musha, M.; Nagano, K.; Nagano, S.; Nakamura, K.; Nakamura, T.; Nakano, H.; Nakano, M.; Nakano, M.; Nakao, H.; Nakao, K.; Narikawa, T.; Ni, W. -T.; Nonomura, T.; Obuchi, Y.; Oh, J. J.; Oh, S. -H.; Ohashi, M.; Ohishi, N.; Ohkawa, M.; Ohmae, N.; Okino, K.; Okutomi, K.; Ono, K.; Ono, Y.; Oohara, K.; Ota, S.; Park, J.; Arellano, F. E. Peña; Pinto, I. M.; Principe, M.; Sago, N.; Saijo, M.; Saito, T.; Saito, Y.; Saitou, S.; Sakai, K.; Sakakibara, Y.; Sasaki, Y.; Sato, S.; Sato, T.; Sato, Y.; Sekiguchi, T.; Sekiguchi, Y.; Shibata, M.; Shiga, K.; Shikano, Y.; Shimoda, T.; Shinkai, H.; Shoda, A.; Someya, N.; Somiya, K.; Son, E. J.; Starecki, T.; Suemasa, A.; Sugimoto, Y.; Susa, Y.; Suwabe, H.; Suzuki, T.; Tachibana, Y.; Tagoshi, H.; Takada, S.; Takahashi, H.; Takahashi, R.; Takamori, A.; Takeda, H.; Tanaka, H.; Tanaka, K.; Tanaka, T.; Tatsumi, D.; Telada, S.; Tomaru, T.; Tsubono, K.; Tsuchida, S.; Tsukada, L.; Tsuzuki, T.; Uchikata, N.; Uchiyama, T.; Uehara, T.; Ueki, S.; Ueno, K.; Uraguchi, F.; Ushiba, T.; van Putten, M. H. P. M.; Wada, S.; Wakamatsu, T.; Yaginuma, T.; Yamamoto, K.; Yamamoto, S.; Yamamoto, T.; Yano, K.; Yokoyama, J.; Yokozawa, T.; Yoon, T. H.; Yuzurihara, H.; Zeidler, S.; Zhao, Y.; Zheng, L.; Agatsuma, K.; Akiyama, Y.; Arai, N.; Asano, M.; Bertolini, A.; Fujisawa, M.; Goetz, R.; Guscott, J.; Hashimoto, Y.; Hayashida, Y.; Hennes, E.; Hirai, K.; Hirayama, T.; Ishitsuka, H.; Kato, J.; Khalaidovski, A.; Koike, S.; Kumeta, A.; Miener, T.; Morioka, M.; Mueller, C. L.; Narita, T.; Oda, Y.; Ogawa, T.; Sekiguchi, T.; Tamura, H.; Tanner, D. B.; Tokoku, C.; Toritani, M.; Utsuki, T.; Uyeshima, M.; Brand, J. van den; van Heijningen, J.; Yamaguchi, S.; Yanagida, A.
Comments: Resolution of some figures has been decreased from its original version submitted to a journal
Submitted: 2017-11-30, last modified: 2017-12-11
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
[2]  oai:arXiv.org:1405.7576  [pdf] - 862855
Sub-Kelvin refrigeration with dry-coolers on a rotating system
Comments: 3pages, 4 figures, to appear in Review of Scientific Instruments
Submitted: 2014-05-29, last modified: 2014-07-18
We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint connectors for electricity and helium gas circulation enable the coolers to be operated and maintained with ease. We performed cool-down tests under a condition of continuous rotation at 20 rpm. We obtained a temperature of 0.23 K with a holding time of more than 24 hours, thus complying with catalog specifications. We monitored the system's performance for four weeks; two weeks with and without rotation. A few-percent difference in conditions was observed between these two states. Most applications can tolerate such a slight difference. The technology developed is useful for various scientific applications requiring sub-Kelvin conditions on rotating platforms.
[3]  oai:arXiv.org:1311.2847  [pdf] - 855791
Mission design of LiteBIRD
Comments: 6 pages, 2 figures
Submitted: 2013-11-12
LiteBIRD is a next-generation satellite mission to measure the polarization of the cosmic microwave background (CMB) radiation. On large angular scales the B-mode polarization of the CMB carries the imprint of primordial gravitational waves, and its precise measurement would provide a powerful probe of the epoch of inflation. The goal of LiteBIRD is to achieve a measurement of the characterizing tensor to scalar ratio $r$ to an uncertainty of $\delta r=0.001$. In order to achieve this goal we will employ a kilo-pixel superconducting detector array on a cryogenically cooled sub-Kelvin focal plane with an optical system at a temperature of 4~K. We are currently considering two detector array options; transition edge sensor (TES) bolometers and microwave kinetic inductance detectors (MKID). In this paper we give an overview of LiteBIRD and describe a TES-based polarimeter designed to achieve the target sensitivity of 2~$\mu$K$\cdot$arcmin over the frequency range 50 to 320~GHz.
[4]  oai:arXiv.org:1306.5040  [pdf] - 853614
Radio-transparent multi-layer insulation for radiowave receivers
Comments: 7 pages, 8 figures, to appear in Review of Scientific Instruments
Submitted: 2013-06-20, last modified: 2013-10-18
In the field of radiowave detection, enlarging the receiver aperture to enhance the amount of light detected is essential for greater scientific achievements. One challenge in using radio transmittable apertures is keeping the detectors cool. This is because transparency to thermal radiation above the radio frequency range increases the thermal load. A technology that maintains cold conditions while allowing larger apertures has been long-awaited. We propose radio-transparent multi-layer insulation (RT-MLI), composed from a set of stacked insulating layers. The insulator is transparent to radio frequencies, but not transparent to infrared radiation. The basic idea for cooling is similar to conventional multi-layer insulation. It leads to a reduction in thermal radiation while maintaining a uniform surface temperature. The advantage of this technique over other filter types is that no thermal links are required. As insulator material, we used foamed polystyrene; its low index of refraction makes an anti-reflection coating unnecessary. We measured the basic performance of RT-MLI to confirm that thermal loads are lowered with more layers. We also confirmed that our RT-MLI has high transmittance to radiowaves, but blocks infrared radiation. For example, RT-MLI with 12 layers has a transmittance greater than 95% (lower than 1%) below 200 GHz (above 4 THz). We demonstrated its effects in a system with absorptive-type filters, where aperture diameters were 200 mm. Low temperatures were successfully maintained for the filters. We conclude that this technology significantly enhances the cooling of radiowave receivers, and is particularly suitable for large-aperture systems. This technology is expected to be applicable to various fields, including radio astronomy, geo-environmental assessment, and radar systems.