Normalized to: Irastorza, I.
[1]
oai:arXiv.org:1910.13957 [pdf] - 2097246
The TREX-DM experiment at the Canfranc Underground Laboratory
Castel, J;
Cebrián, S;
Dafni, T;
Galán, J;
Irastorza, IG;
Luzón, G;
Margalejo, C;
Mirallas, H;
de Solórzano, A Ortiz;
Peiró, A;
Ruiz-Chóliz, E
Submitted: 2019-10-30, last modified: 2020-03-22
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for
low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using
light elements (Ne, Ar) as target in a high pressure TPC equipped with
Micromegas readouts. Here, a description of the detector, the first results
from commissioning data and the expected sensitivity from the developed
background model are briefly presented.
[2]
oai:arXiv.org:1812.04519 [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Dafni, T.;
Galan, J.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Mirallas, H.;
de Solorzano, A. Ortiz;
Ruiz-Choliz, E.
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive
Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas
readout planes at the Canfranc Underground Laboratory. The detector can hold in
the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30
kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered
acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low
background level in the lowest energy region is another essential requirement.
To assess the expected background, all the relevant sources have been
considered, including the measured fluxes of gamma radiation, muons and
neutrons at the Canfranc Laboratory, together with the activity of most of the
components used in the detector and ancillary systems, obtained in a complete
assay program. The background contributions have been simulated by means of a
dedicated application based on Geant4 and a custom-made code for the detector
response. The background model developed for the detector presently installed
in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region
of interest, making TREX-DM competitive in the search for low-mass WIMPs. A
roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[3]
oai:arXiv.org:1906.01084 [pdf] - 1894436
First Results on the Search for Chameleons with the KWISP Detector at
CAST
Cuendis, S. Arguedas;
Baier, J.;
Barth, K.;
Baum, S.;
Bayirli, A.;
Belov, A.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Castel, J. F.;
Cetin, S. A.;
Dafni, T.;
Davenport, M.;
Dermenev, A.;
Desch, K.;
Döbrich, B.;
Fischer, H.;
Funk, W.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gninenko, S.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakovčić, K.;
Kaminski, J.;
Karuza, M.;
Krieger, C.;
Lakić, B.;
Laurent, J. M.;
Luzón, G.;
Maroudas, M.;
Miceli, L.;
Neff, S.;
Ortega, I.;
Ozbey, A.;
Pivovaroff, M. J.;
Rosu, M.;
Ruz, J.;
Chóliz, E. Ruiz;
Schmidt, S.;
Schumann, M.;
Semertzidis, Y. K.;
Solanki, S. K.;
Stewart, L.;
Tsagris, I.;
Vafeiadis, T.;
Vogel, J. K.;
Vretenar, M.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2019-06-03
We report on a first measurement with a sensitive opto-mechanical force
sensor designed for the direct detection of coupling of real chameleons to
matter. These dark energy candidates could be produced in the Sun and stream
unimpeded to Earth. The KWISP detector installed on the CAST axion search
experiment at CERN looks for tiny displacements of a thin membrane caused by
the mechanical effect of solar chameleons. The displacements are detected by a
Michelson interferometer with a homodyne readout scheme. The sensor benefits
from the focusing action of the ABRIXAS X-ray telescope installed at CAST,
which increases the chameleon flux on the membrane. A mechanical chopper placed
between the telescope output and the detector modulates the incoming chameleon
stream. We present the results of the solar chameleon measurements taken at
CAST in July 2017, setting an upper bound on the force acting on the membrane
of $80$~pN at 95\% confidence level. The detector is sensitive for direct
coupling to matter $10^4 \leq\beta_m \leq 10^8$, where the coupling to photons
is locally bound to $\beta_\gamma \leq 10^{11}$.
[4]
oai:arXiv.org:1811.09290 [pdf] - 1842424
Weighing the Solar Axion
Dafni, Theopisti;
O'Hare, Ciaran A. J.;
Lakić, Biljana;
Galán, Javier;
Iguaz, Francisco J.;
Irastorza, Igor G.;
Jakovčić, Krešimir;
Luzón, Gloria;
Redondo, Javier;
Chóliz, Elisa Ruiz
Submitted: 2018-11-22, last modified: 2019-02-20
Axion helioscopes search for solar axions and axion-like particles via
inverse Primakoff conversion in strong laboratory magnets pointed at the Sun.
While helioscopes can always measure the axion coupling to photons, the
conversion signal is independent of the mass for axions lighter than around
0.02 eV. Masses above this value on the other hand have suppressed signals due
to axion-photon oscillations which destroy the coherence of the conversion
along the magnet. However, the spectral oscillations present in the axion
conversion signal between these two regimes are highly dependent on the axion
mass. We show that these oscillations are observable given realistic energy
resolutions and can be used to determine the axion mass to within percent level
accuracies. Using projections for the upcoming helioscope IAXO, we demonstrate
that $>3\sigma$ sensitivity to a non-zero axion mass is possible between $3
\times 10^{-3}$ and $10^{-1}$ eV for both the Primakoff and axion-electron
solar fluxes.
[5]
oai:arXiv.org:1803.07547 [pdf] - 1790650
High magnetic fields for fundamental physics
Battesti, Rémy;
Beard, Jerome;
Böser, Sebastian;
Bruyant, Nicolas;
Budker, Dmitry;
Crooker, Scott A.;
Daw, Edward J.;
Flambaum, Victor V.;
Inada, Toshiaki;
Irastorza, Igor G.;
Karbstein, Felix;
Kim, Dong Lak;
Kozlov, Mikhail G.;
Melhem, Ziad;
Phipps, Arran;
Pugnat, Pierre;
Rikken, Geert;
Rizzo, Carlo;
Schott, Matthias;
Semertzidis, Yannis K.;
Kate, Herman H. J. ten;
Zavattini, Guido
Submitted: 2018-03-20
Various fundamental-physics experiments such as measurement of the
birefringence of the vacuum, searches for ultralight dark matter (e.g.,
axions), and precision spectroscopy of complex systems (including exotic atoms
containing antimatter constituents) are enabled by high-field magnets. We give
an overview of current and future experiments and discuss the state-of-the-art
DC- and pulsed-magnet technologies and prospects for future developments.
[6]
oai:arXiv.org:1706.05818 [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Amare, J.;
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Cuesta, C.;
Dafni, T.;
Galan, J.;
Garcia, E.;
Garza, J. G.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Martinez, M.;
Mirallas, H.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Ruiz-Choliz, E.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background
conditions at energies below a few tens of keV. Radioactive isotopes are
produced via cosmogenic activation in detectors and other materials and those
isotopes constitute a background source which has to be under control. In
particular, tritium is specially relevant due to its decay properties (very low
endpoint energy and long half-life) when induced in the detector medium, and
because it can be generated in any material as a spallation product.
Quantification of cosmogenic production of tritium is not straightforward,
neither experimentally nor by calculations. In this work, a method for the
calculation of production rates at sea level has been developed and applied to
some of the materials typically used as targets in dark matter detectors
(germanium, sodium iodide, argon and neon); it is based on a selected
description of tritium production cross sections over the entire energy range
of cosmic nucleons. Results have been compared to available data in the
literature, either based on other calculations or from measurements. The
obtained tritium production rates, ranging from a few tens to a few hundreds of
nuclei per kg and per day at sea level, point to a significant contribution to
the background in dark matter experiments, requiring the application of
specific protocols for target material purification, material storing
underground and limiting the time the detector is on surface during the
building process in order to minimize the exposure to the most dangerous cosmic
ray components.
[7]
oai:arXiv.org:1709.10062 [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Aznar, F;
Castel, J;
Cebrian, S;
Coarasa, I;
Dafni, T;
Galan, J;
Garza, JG;
Iguaz, FJ;
Irastorza, IG;
Luzon, G;
Mirallas, H;
de Solorzano, A Ortiz;
Ruiz-Choliz, E;
Villar, JA
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a
gas time projection chamber equipped with novel micromegas readout planes at
the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized
gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg
of Ne. The micromegas will be read with a self-triggered acquisition, allowing
for effective thresholds below 0.4 keV (electron equivalent). The preliminary
background model, following a complete material screening program, points to
levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest,
making TREX-DM competitive. The status of the commissioning, description of the
background model and the corresponding WIMP sensitivity will be presented here.
[8]
oai:arXiv.org:1708.02111 [pdf] - 1586844
Stellar Recipes for Axion Hunters
Submitted: 2017-08-07
There are a number of observational hints from astrophysics which point to
the existence of stellar energy losses beyond the ones accounted for by
neutrino emission. These excessive energy losses may be explained by the
existence of a new sub-keV mass pseudoscalar Nambu--Goldstone boson with tiny
couplings to photons, electrons, and nucleons. An attractive possibility is to
identify this particle with the axion -- the hypothetical pseudo
Nambu--Goldstone boson predicted by the Peccei--Quinn solution to the strong CP
problem. We explore this possibility in terms of a DFSZ-type axion and of a
KSVZ-type axion/majoron, respectively. Both models allow a good global fit to
the data, prefering an axion mass around 10 meV. We show that future axion
experiments -- the fifth force experiment ARIADNE and the helioscope IAXO --
can attack the preferred mass range from the lower and higher end,
respectively. An axion in this mass range can also be the main constituent of
dark matter.
[9]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[10]
oai:arXiv.org:1512.08108 [pdf] - 1415039
Cool WISPs for stellar cooling excesses
Submitted: 2015-12-26, last modified: 2016-05-30
Several stellar systems (white dwarfs, red giants, horizontal branch stars
and possibly the neutron star in the supernova remnant Cassiopeia A) show a
mild preference for a non-standard cooling mechanism when compared with
theoretical models. This exotic cooling could be provided by Weakly Interacting
Slim Particles (WISPs), produced in the hot cores and abandoning the star
unimpeded, contributing directly to the energy loss. Taken individually, these
excesses do not show a strong statistical weight. However, if one mechanism
could consistently explain several of them, the hint could be significant. We
analyze the hints in terms of neutrino anomalous magnetic moments, minicharged
particles, hidden photons and axion-like particles (ALPs). Among them, the ALP
or a massless HP represent the best solution. Interestingly, the hinted ALP
parameter space is accessible to the next generation proposed ALP searches,
such as ALPS II and IAXO and the massless HP requires a multi TeV energy scale
of new physics that might be accessible at the LHC.
[11]
oai:arXiv.org:1503.04561 [pdf] - 1376478
Search for chameleons with CAST
Anastassopoulos, V.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Christensen, F.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Desch, K.;
Dermenev, A.;
Eleftheriadis, C.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Hailey, C.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakobsen, A.;
Jakovčić, K.;
Kaminski, J.;
Karuza, M.;
Kavuk, M.;
Krčmar, M.;
Krieger, C.;
Krüger, A.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Luzón, G.;
Neff, S.;
Ortega, I.;
Papaevangelou, T.;
Pivovarov, M. J.;
Raffelt, G.;
Riege, H.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Solanki, S. K.;
Vafeiadis, T.;
Villar, J. A.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.;
Brax, P.;
Lavrentyev, I.;
Upadhye, A.
Submitted: 2015-03-16, last modified: 2016-03-18
In this work we present a search for (solar) chameleons with the CERN Axion
Solar Telescope (CAST). This novel experimental technique, in the field of dark
energy research, exploits both the chameleon coupling to matter ($\beta_{\rm
m}$) and to photons ($\beta_{\gamma}$) via the Primakoff effect. By reducing
the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV
CAST became sensitive to the converted solar chameleon spectrum which peaks
around 600$\,$eV. Even though we have not observed any excess above background,
we can provide a 95% C.L. limit for the coupling strength of chameleons to
photons of $\beta_{\gamma}\!\lesssim\!10^{11}$ for $1<\beta_{\rm m}<10^6$.
[12]
oai:arXiv.org:1602.00039 [pdf] - 1350800
Experimental Searches for the Axion and Axion-like Particles
Submitted: 2016-01-29
Four decades after its prediction, the axion remains the most compelling
solution to the Strong-CP problem and a well-motivated dark matter candidate,
inspiring a host of elegant and ultrasensitive experiments based on
axion-photon mixing. This report reviews the experimental situation on several
fronts. The microwave cavity experiment is making excellent progress in the
search for dark matter axions in the microelectronvolt range and may be
plausibly extended up to 100 mu eV. Within the past several years however, it
has been realized that axions are pervasive throughout string theories, but
with masses that fall naturally in the nanoelectronvolt range, for which a
NMR-based search is under development. Searches for axions emitted from the
Sun's burning core, and purely laboratory experiments based on photon
regeneration have both made great strides in recent years, with ambitious
projects proposed for the coming decade. Each of these campaigns has pushed the
state of the art in technology, enabling large gains in sensitivity and mass
reach. Furthermore each modality has also been exploited to search for more
generalized axion-like particles, that will also be discussed in this report.
We are hopeful, even optimistic, that the next review of the subject will
concern the discovery of the axion, its properties, and its exploitation as a
probe of early universe cosmology and structure formation.
[13]
oai:arXiv.org:1509.06190 [pdf] - 1323484
A Micromegas-based low-background x-ray detector coupled to a
slumped-glass telescope for axion research
Aznar, F.;
Castel, J.;
Christensen, F. E.;
Dafni, T.;
Decker, T. A.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Giomataris, I.;
Gracia, J. G.;
Hailey, C. J.;
Hill, R. M.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakobsen, A. C.;
Luzon, G.;
Mirallas, H.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Ruz, J.;
Vafeiadis, T.;
Vogel, J. K.
Submitted: 2015-09-21
We report on the design, construction and operation of a low background x-ray
detection line composed of a shielded Micromegas (micromesh gaseous structure)
detector of the microbulk technique. The detector is made from radiopure
materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m
focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of
thermally-formed (or "slumped") glass substrates deposited with multilayer
coatings. The system has been conceived as a technological pathfinder for the
future International Axion Observatory (IAXO), as it combines two of the
techniques (optic and detector) proposed in the conceptual design of the
project. It is innovative for two reasons: it is the first time an x-ray optic
has been designed and fabricated specifically for axion research, and the first
time a Micromegas detector has been operated with an x-ray optic. The line has
been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and
is currently looking for solar axions. The combination of the XRT and
Micromegas detector provides the best signal-to-noise ratio obtained so far by
any detection system of the CAST experiment with a background rate of
5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and
signal spot area.
[14]
oai:arXiv.org:1508.03006 [pdf] - 1330987
Exploring 0.1-10$\,$eV axions with a new helioscope concept
Galán, J.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Iguaz, F. J.;
Irastorza, I. G.;
García, J. A.;
Gracia, J.;
Luzón, G.;
Papaevangelou, T.;
Redondo, J.;
Tomás, A.
Submitted: 2015-08-12, last modified: 2015-09-07
We explore the possibility to develop a new axion helioscope type, sensitive
to the higher axion mass region favored by axion models. We propose to use a
low background large volume TPC immersed in an intense magnetic field. Contrary
to traditional tracking helioscopes, this detection technique takes advantage
of the capability to directly detect the photons converted on the buffer gas
which defines the axion mass sensitivity region, and does not require pointing
the magnet to the Sun. The operation flexibility of a TPC to be used with
different gas mixtures (He, Ne, Xe, etc) and pressures (from 10 mbar to 10 bar)
will allow to enhance sensitivity for axion masses from few meV to several eV.
We present different helioscope data taking scenarios, considering detection
efficiency and axion absorption probability, and show the sensitivities
reachable with this technique to be few $\times$ 10$^{-11}\,$GeV$^{-1}$ for a
5$\,$T$\,$m$^3$ scale TPC. We show that a few years program taking data with
such setup would allow to probe the KSVZ axion model for axion masses above 100
meV.
[15]
oai:arXiv.org:1501.01466 [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas
x-ray detectors for axion searches
Iguaz, F. J.;
Aune, S.;
Aznar, F.;
Castel, J. F.;
Dafni, T.;
Davenport, M.;
Ferrer-Ribas, E.;
Galan, J.;
Garcia, J. A.;
Garza, J. G.;
Giomataris, I.;
Irastorza, I. G.;
Papaevangelou, T.;
Rodriguez, A.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in
the presence of high magnetic fields. The use of low background x-ray detectors
is an essential component contributing to the sensitivity of these searches. In
this work, we review the recent advances on Micromegas detectors used in the
CERN Axion Solar Telescope (CAST) and proposed for the future International
Axion Observatory (IAXO). The actual setup in CAST has achieved background
levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than
the first generation of Micromegas detectors. This reduction is based on active
and passive shielding techniques, the selection of radiopure materials, offline
discrimination techniques and the high granularity of the readout. We describe
in detail the background model of the detector, based on its operation at CAST
site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4
simulations. The best levels currently achieved at LSC are low than 10$^{-7}$
keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of
this technology in IAXO. Finally, we present some ideas and results for
reducing the energy threshold of these detectors below 1 keV, using
high-transparent windows, autotrigger electronics and studying the cluster
shape at different energies. As a high flux of axion-like-particles is expected
in this energy range, a sub-keV threshold detector could enlarge the physics
case of axion helioscopes.
[16]
oai:arXiv.org:1501.01626 [pdf] - 918886
Characterization of a Spherical Proportional Counter in argon-based
mixtures
Submitted: 2015-01-07
The Spherical Proportional Counter is a novel type of radiation detector,
with a low energy threshold (typically below 100 eV) and good energy
resolution. This detector is being developed by the network NEWS, which
includes several applications. We can name between many others Dark Matter
searches, low level radon and neutron counting or low energy neutrino detection
from supernovas or nuclear reactors via neutrino-nucleus elastic scattering. In
this context, this works will present the characterization of a spherical
detector of 1 meter diameter using two argon-based mixtures (with methane and
isobutane) and for gas pressures between 50 and 1250 mbar. In each case, the
energy resolution shows its best value in a wide range of gains, limited by the
ballistic effect at low gains and by ion-backflow at high gains. Moreover, the
best energy resolution shows a degradation with pressure. These effects will be
discussed in terms of gas avalanche properties. Finally, the effect of an
electrical field corrector in the homogenity of the gain and the energy
threshold measured in our setup will be also discussed.
[17]
oai:arXiv.org:1307.1985 [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark
matter gap
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Brauninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Da Riva, E.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Georgiopoulou, E.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Marzoa, M. Gomez;
Gruber, E.;
Guthorl, T.;
Hartmann, R.;
Hauf, S.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Karuza, M.;
Konigsmann, K.;
Kotthaus, R.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Lang, P. M.;
Laurent, J. M.;
Liolios, A.;
Ljubicic, A.;
Lozza, V.;
Luzon, G.;
Neff, S.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Riege, H.;
Rodriguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Shilon, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomas, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar
axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV.
This closes the gap to the cosmological hot dark matter limit and actually
overlaps with it. From the absence of excess X-rays when the magnet was
pointing to the Sun we set a typical upper limit on the axion-photon coupling
of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on
the pressure setting. Future direct solar axion searches will focus on
increasing the sensitivity to smaller values of g_a, for example by the
currently discussed next generation helioscope IAXO.
[18]
oai:arXiv.org:1311.0029 [pdf] - 741002
Dark Sectors and New, Light, Weakly-Coupled Particles
Essig, R.;
Jaros, J. A.;
Wester, W.;
Adrian, P. Hansson;
Andreas, S.;
Averett, T.;
Baker, O.;
Batell, B.;
Battaglieri, M.;
Beacham, J.;
Beranek, T.;
Bjorken, J. D.;
Bossi, F.;
Boyce, J. R.;
Cates, G. D.;
Celentano, A.;
Chou, A. S.;
Cowan, R.;
Curciarello, F.;
Davoudiasl, H.;
deNiverville, P.;
De Vita, R.;
Denig, A.;
Dharmapalan, R.;
Dongwi, B.;
Döbrich, B.;
Echenard, B.;
Espriu, D.;
Fegan, S.;
Fisher, P.;
Franklin, G. B.;
Gasparian, A.;
Gershtein, Y.;
Graham, M.;
Graham, P. W.;
Haas, A.;
Hatzikoutelis, A.;
Holtrop, M.;
Irastorza, I.;
Izaguirre, E.;
Jaeckel, J.;
Kahn, Y.;
Kalantarians, N.;
Kohl, M.;
Krnjaic, G.;
Kubarovsky, V.;
Lee, H-S.;
Lindner, A.;
Lobanov, A.;
Marciano, W. J.;
Marsh, D. J. E.;
Maruyama, T.;
McKeen, D.;
Merkel, H.;
Moffeit, K.;
Monaghan, P.;
Mueller, G.;
Nelson, T. K.;
Neil, G. R.;
Oriunno, M.;
Pavlovic, Z.;
Phillips, S. K.;
Pivovaroff, M. J.;
Poltis, R.;
Pospelov, M.;
Rajendran, S.;
Redondo, J.;
Ringwald, A.;
Ritz, A.;
Ruz, J.;
Saenboonruang, K.;
Schuster, P.;
Shinn, M.;
Slatyer, T. R.;
Steffen, J. H.;
Stepanyan, S.;
Tanner, D. B.;
Thaler, J.;
Tobar, M. E.;
Toro, N.;
Upadye, A.;
Van de Water, R.;
Vlahovic, B.;
Vogel, J. K.;
Walker, D.;
Weltman, A.;
Wojtsekhowski, B.;
Zhang, S.;
Zioutas, K.
Submitted: 2013-10-31
Dark sectors, consisting of new, light, weakly-coupled particles that do not
interact with the known strong, weak, or electromagnetic forces, are a
particularly compelling possibility for new physics. Nature may contain
numerous dark sectors, each with their own beautiful structure, distinct
particles, and forces. This review summarizes the physics motivation for dark
sectors and the exciting opportunities for experimental exploration. It is the
summary of the Intensity Frontier subgroup "New, Light, Weakly-coupled
Particles" of the Community Summer Study 2013 (Snowmass). We discuss axions,
which solve the strong CP problem and are an excellent dark matter candidate,
and their generalization to axion-like particles. We also review dark photons
and other dark-sector particles, including sub-GeV dark matter, which are
theoretically natural, provide for dark matter candidates or new dark matter
interactions, and could resolve outstanding puzzles in particle and
astro-particle physics. In many cases, the exploration of dark sectors can
proceed with existing facilities and comparatively modest experiments. A rich,
diverse, and low-cost experimental program has been identified that has the
potential for one or more game-changing discoveries. These physics
opportunities should be vigorously pursued in the US and elsewhere.
[19]
oai:arXiv.org:1211.4508 [pdf] - 1157898
Ionization and scintillation response of high-pressure xenon gas to
alpha particles
NEXT Collaboration;
Álvarez, V.;
Borges, F. I. G. M.;
Cárcel, S.;
Cebrián, S.;
Cervera, A.;
Conde, C. A. N.;
Dafni, T.;
Díaz, J.;
Egorov, M.;
Esteve, R.;
Evtoukhovitch, P.;
Fernandes, L. M. P.;
Ferrario, P.;
Ferreira, A. L.;
Freitas, E. D. C.;
Gehman, V. M.;
Gil, A.;
Goldschmidt, A.;
Gómez, H.;
Gómez-Cadenas, J. J.;
González-Díaz, D.;
Gutiérrez, R. M.;
Hauptman, J.;
Morata, J. A. Hernando;
Herrera, D. C.;
Irastorza, I. G.;
Jinete, M. A.;
Labarga, L.;
Laing, A.;
Liubarsky, I.;
Lopes, J. A. M.;
Lorca, D.;
Losada, M.;
Luzón, G.;
Marí, A.;
Martín-Albo, J.;
Miller, T.;
Moiseenko, A.;
Monrabal, F.;
Monteiro, C. M. B.;
Mora, F. J.;
Moutinho, L. M.;
Vidal, J. Muñoz;
da Luz, H. Natal;
Navarro, G.;
Nebot-Guinot, M.;
Nygren, D.;
Oliveira, C. A. B.;
Palma, R.;
Pérez, J.;
Aparicio, J. L. Pérez;
Renner, J.;
Ripoll, L.;
Rodríguez, A.;
Rodríguez, J.;
Santos, F. P.;
Santos, J. M. F. dos;
Segui, L.;
Serra, L.;
Shuman, D.;
Simón, A.;
Sofka, C.;
Sorel, M.;
Toledo, J. F.;
Tomás, A.;
Torrent, J.;
Tsamalaidze, Z.;
Vázquez, D.;
Veloso, J. F. C. A.;
Webb, R.;
White, J. T;
Yahlali, N.
Submitted: 2012-11-19, last modified: 2013-05-21
High-pressure xenon gas is an attractive detection medium for a variety of
applications in fundamental and applied physics. In this paper we study the
ionization and scintillation detection properties of xenon gas at 10 bar
pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO
time projection chamber, the large scale prototype of the NEXT-100 neutrinoless
double beta decay experiment, in three different drift electric field
configurations. We measure the ionization electron drift velocity and
longitudinal diffusion, and compare our results to expectations based on
available electron scattering cross sections on pure xenon. In addition, two
types of measurements addressing the connection between the ionization and
scintillation yields are performed. On the one hand we observe, for the first
time in xenon gas, large event-by-event correlated fluctuations between the
ionization and scintillation signals, similar to that already observed in
liquid xenon. On the other hand, we study the field dependence of the average
scintillation and ionization yields. Both types of measurements may shed light
on the mechanism of electron-ion recombination in xenon gas for highly-ionizing
particles. Finally, by comparing the response of alpha particles and electrons
in NEXT-DEMO, we find no evidence for quenching of the primary scintillation
light produced by alpha particles in the xenon gas.
[20]
oai:arXiv.org:1302.6283 [pdf] - 928601
CAST constraints on the axion-electron coupling
Barth, K.;
Belov, A.;
Beltran, B.;
Brauninger, H.;
Carmona, J. M.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Di Lella, L.;
Eleftheriadis, C.;
Englhauser, J.;
Fanourakis, G.;
Ribas, E. Ferrer;
Fischer, H.;
Franz, J.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Hassinoff, M. D.;
Heinsius, F. H.;
Hoffmann, D. H. H.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Kang, D.;
Konigsmann, K.;
Kotthaus, R.;
Kousouris, K.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Liolios, A.;
Ljubicic, A.;
Lutz, G.;
Luzon, G.;
Miller, D. W.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Redondo, J.;
Riege, H.;
Rodriguez, A.;
Ruz, J.;
Savvidis, I.;
Semertzidis, Y.;
Stewart, L.;
Van Bibber, K.;
Vieira, J. D.;
Villar, J. A.;
Vogel, J. K.;
Walckiers, L.;
Zioutas, K.
Submitted: 2013-02-25, last modified: 2013-04-19
In non-hadronic axion models, which have a tree-level axion-electron
interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton
scattering, and axio-recombination, the "BCA processes." Based on a new
calculation of this flux, including for the first time axio-recombination, we
derive limits on the axion-electron Yukawa coupling g_ae and axion-photon
interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a <
10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a
next-generation axion helioscope such as the proposed IAXO could push this
sensitivity into a range beyond stellar energy-loss limits and test the
hypothesis that white-dwarf cooling is dominated by axion emission.
[21]
oai:arXiv.org:1210.3287 [pdf] - 1152052
Micromegas-TPC operation at high pressure in xenon-trimethylamine
mixtures
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Gonzalez-Diaz, D.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Rodríguez, A.;
Segui, L.;
Tomás, A.
Submitted: 2012-10-11, last modified: 2012-11-23
In this work we present a systematic study of Micromegas detectors in high
pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains
and energy resolutions for 22.1 keV X-rays are measured for pressures between 1
and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We
observe stable operation at all pressures, and a strongly enhanced gas gain,
suggestive of Penning-like energy-transfer processes. The effect is present at
all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3
%. Operating in this concentration range, the maximum gain reached values as
high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable
for 22.1 keV X-rays is substantially better than the one previously obtained in
pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of
interest for calorimetric applications of high pressure gas Xe TPCs, in
particular for the search of the neutrinoless double beta decay of Xe-136. The
resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value
of Xe-136 for 1 (10) bar.
[22]
oai:arXiv.org:1209.6347 [pdf] - 1453905
Results and perspectives of the solar axion search with the CAST
experiment
Ferrer-Ribas, E.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Ezer, C.;
Fanourakis, G.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gómez, H.;
Gruber, E.;
Guthörl, T.;
Hartmann, R.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovčić, K.;
Karuza, M.;
Königsmann, K.;
Kotthaus, R.;
Krčmar, M.;
Kuster, M.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Lozza, V.;
Lutz, G.;
Luzón, G.;
Morales, J.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Rashba, T.;
Riege, H.;
Rodríguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomás, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2012-09-27, last modified: 2012-10-30
The status of the solar axion search with the CERN Axion Solar Telescope
(CAST) will be presented. Recent results obtained by the use of $^3$He as a
buffer gas has allowed us to extend our sensitivity to higher axion masses than
our previous measurements with $^4$He. With about 1 h of data taking at each of
252 different pressure settings we have scanned the axion mass range 0.39 eV$
\le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the
magnet was pointing to the Sun we set a typical upper limit on the axion-photon
coupling of g$_{a\gamma} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the
exact value depending on the pressure setting. CAST published results represent
the best experimental limit on the photon couplings to axions and other similar
exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the
considered mass range and for the first time the limit enters the region
favored by QCD axion models. Preliminary sensitivities for axion masses up to
1.16 eV will also be shown reaching mean upper limits on the axion-photon
coupling of g$_{a\gamma} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L.
Expected sensibilities for the extension of the CAST program up to 2014 will be
presented. Moreover long term options for a new helioscope experiment will be
evoked.
[23]
oai:arXiv.org:1207.6129 [pdf] - 953574
Direct detection of dark matter axions with directional sensitivity
Submitted: 2012-07-25, last modified: 2012-08-28
We study the directional effect of the expected axion dark matter signal in a
resonant cavity of an axion haloscope detector, for cavity geometries not
satisfying the condition that the axion de Broglie wavelength $\lambda_a$ is
sufficiently larger than the cavity dimensions $L$ for a fully coherent
conversion, i.e. $\lambda_a \gtrsim 2\pi L$. We focus on long thin cavities
immersed in dipole magnets and find, for appropriately chosen cavity lengths,
an O(1) modulation of the signal with the cavity orientation with respect the
momentum distribution of the relic axion background predicted by the isothermal
sphere model for the galactic dark matter halo. This effect can be exploited to
design directional axion dark matter detectors, providing an unmistakable
signature of the extraterrestrial origin of a possible positive detection.
Moreover, the precise shape of the modulation may give information of the
galactic halo distribution and, for specific halo models, give extra
sensitivity for higher axion masses.
[24]
oai:arXiv.org:1208.5690 [pdf] - 771411
CAST microbulk micromegas in the Canfranc Underground Laboratory
Tomás, A.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gómez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Papaevangelou, T.;
Rodríguez, A.;
Ruz, J.;
Seguí, L.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2012-08-28
During the last taking data campaigns of the CAST experiment, the micromegas
detectors have achieved background levels of $\approx 5 \times
10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has
been possible thanks to the introduction of the microbulk technology, the
implementation of a shielding and the development of discrimination algorithms.
It has motivated new studies towards a deeper understanding of CAST detectors
background. One of the working lines includes the construction of a replica of
the set-up used in CAST by micromegas detectors and its installation in the
Canfranc Underground Laboratory. Thanks to the comparison between the
performance of the detectors underground and at surface, shielding upgrades,
etc, different contributions to the detectors background have been evaluated.
In particular, an upper limit $< 2 \times 10^{-7}$keV$^{-1}$cm$^{-2}$s$^{-1}$
for the intrinsic background of the detector has been obtained. This work means
a first evaluation of the potential of the newest micromegas technology in an
underground laboratory, the most suitable environment for Rare Event Searches.
[25]
oai:arXiv.org:1110.2608 [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Galan, J.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gomez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Papaevangelou, T.;
Rodriguez, A.;
Ruz, J.;
Segui, L.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination
capabilities, are good candidates for rare event search experiments. Recent
X-ray background levels achieved by these detectors in the CAST experiment have
motivated further studies in the nature of the background levels measured. In
particular, different shielding configurations have been tested at the Canfranc
Underground Laboratory, using a microbulk type detector which was previously
running at the CAST experiment. The first results underground show that this
technology, which is made of low radiative materials, is able to reach
background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a
proper shielding. Moreover, the experimental background measurements are
complemented with Geant4 simulations which allow to understand the origin of
the background, and to optimize future shielding set-ups.
[26]
oai:arXiv.org:1009.1827 [pdf] - 261761
Micromegas readouts for double beta decay searches
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Giomataris, I.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Rodríguez, A.;
Seguí, L.;
Tomás, A.
Submitted: 2010-09-09
Double beta $\beta\beta$ decay experiments are one of the most active
research topics in Neutrino Physics. The measurement of the neutrinoless mode
$0\nu\beta\beta$ could give unique information on the neutrino mass scale and
nature. The current generation of experiments aims at detector target masses at
the 100 kg scale, while the next generation will need to go to the ton scale in
order to completely explore the inverse hierarchy models of neutrino mass. Very
good energy resolutions and ultra-low background levels are the two main
experimental requirements for a successful experiment. The topological
information of the $\beta\beta$ events offered by gaseous detectors like gas
Time Projection Chambers (TPC) could provide a very powerful tool of signal
identification and background rejection. However only recent advances in TPC
readouts may assure the competitiveness of a high pressure gas TPCs for
$\beta\beta$ searches, especially regarding the required energy resolution. In
this paper we present first results on energy resolution with state-of-the-art
microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV
alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have
been achieved for pressures up to 5 bar. These results, together with their
recently measured radiopurity , prove that Micromegas readouts are not only a
viable option but a very competitive one for $\beta\beta$ searches.
[27]
oai:arXiv.org:0911.2855 [pdf] - 30672
Physics at Underground Laboratories: Direct Detection of Dark Matter
Submitted: 2009-11-15
Underground laboratories host two kind of experiments at the frontier of our
knowledge in Particle Physics, Astrophysics and Cosmology: the direct detection
of the Dark Matter of the Universe and the search for the Neutrinoless Double
Beta Decay of the nuclei. Both experimental quests pose great technical
challenges which are being addressed in different ways by an important number
of groups. Here a updated review of the efforts being done to detect Dark
Matter particles is presented, emphasizing latest achievements.
[28]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[29]
oai:arXiv.org:0706.1636 [pdf] - 2119
Background studies and shielding effects for the TPC detector of the
CAST experiment
Luzón, G.;
Beltrán, B.;
Carmona, J. M.;
Cebrián, S.;
Gómez, H.;
Irastorza, I. G.;
Morales, J.;
Ortíz, A.;
Rodríguez, A.;
Ruz, J.;
Villar, J. A.
Submitted: 2007-06-12
Sunset solar axions traversing the intense magnetic field of the CERN Axion
Solar Telescope (CAST) experiment may be detected in a Time Projection Chamber
(TPC) detector, as X-rays signals. These signals could be masked, however, by
the inhomogeneous background of materials in the experimental site. A detailed
analysis, based on the detector characteristics, the background radiation at
the CAST site, simulations and experimental results, has allowed us to design a
shielding which reduces the background level by a factor of ~4 compared to the
detector without shielding, depending on its position, in the energy range
between 1 and 10 keV. Moreover, this shielding has improved the homogeneity of
background measured by the TPC.
[30]
oai:arXiv.org:0704.2946 [pdf] - 653
Background study for the pn-CCD detector of CERN Axion Solar Telescope
Cebrián, S.;
Rodríguez, A.;
Kuster, M.;
Beltrán, B.;
Carmona, J. M.;
Gómez, H.;
Hartmann, R.;
Irastorza, I. G.;
Kotthaus, R.;
Luzón, G.;
Morales, J.;
de Solórzano, A. Ortiz;
Ruz, J.;
Strüder, L.;
Villar, J. A.
Submitted: 2007-04-23
The CERN Axion Solar Telescope (CAST) experiment searches for axions from the
Sun converted into photons with energies up to around 10 keV via the inverse
Primakoff effect in the high magnetic field of a superconducting Large Hadron
Collider (LHC) prototype magnet. A backside illuminated pn-CCD detector in
conjunction with an X-ray mirror optics is one of the three detectors used in
CAST to register the expected photon signal. Since this signal is very rare and
different background components (environmental gamma radiation, cosmic rays,
intrinsic radioactive impurities in the set-up, ...) entangle it, a detailed
study of the detector background has been undertaken with the aim to understand
and further reduce the background level of the detector. The analysis is based
on measured data taken during the Phase I of CAST and on Monte Carlo
simulations of different background components. This study will show that the
observed background level (at a rate of (8.00+-0.07)10^-5 counts/cm^2/s/keV
between 1 and 7 keV) seems to be dominated by the external gamma background due
to usual activities at the experimental site, while radioactive impurities in
the detector itself and cosmic neutrons could make just smaller contribution.
[31]
oai:arXiv.org:astro-ph/0211535 [pdf] - 1591945
Status of IGEX dark matter search at Canfranc Underground Laboratory
Irastorza, I. G.;
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Carmona, J. M.;
Cebrian, S.;
Garcia, E.;
Kirpichnikov, I. V.;
Klimenko, A. A.;
Luzon, G.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Osetrov, S. B.;
Pogosov, V. S.;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Smolnikov, A. A.;
Tamanyan, A. G.;
Vasenko, A. A.;
Vasiliev, S. I.;
Villar, J. A.
Submitted: 2002-11-25
One IGEX 76Ge double-beta decay detector is currently operating in the
Canfranc Underground Laboratory in a search for dark matter WIMPs, through the
Ge nuclear recoil produced by the WIMP elastic scattering. In this talk we
report on the on-going efforts to understand and eventually reject the
background at low energy. These efforts have led to the improvement of the
neutron shielding and to partial reduction of the background, but still the
remaining events are not totally identified. A tritium contamination or
muon-induced neutrons are considered as possible sources, simulations and
experimental test being still under progress. According to the success of this
study we comment the prospects of the experiment as well as those of its future
extension, the GEDEON dark matter experiment.
[32]
oai:arXiv.org:hep-ph/0108146 [pdf] - 113901
Physics Potential and Prospects for CUORE and CUORICINO experiments
Submitted: 2001-08-17, last modified: 2002-06-17
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment
projects to construct and operate an array of 1000 cryogenic thermal detectors
of a mass of 760 g each to investigate rare events physics, in particular,
double beta decay and non baryonic particle dark matter. A first step towards
CUORE is CUORICINO, an array of 56 of such bolometers, currently being
installed in the Gran Sasso. In this paper we report the physics potential of
both stages of the experiment regarding neutrinoless double beta decay of
130Te, WIMP searches and solar axions.
[33]
oai:arXiv.org:astro-ph/0112272 [pdf] - 1232796
The ROSEBUD experiment at Canfranc: 2001 report
Cebrian, S.;
Coron, N.;
Dambier, G.;
Garcia, E.;
Irastorza, I. G.;
Leblanc, J.;
de Marcillac, P.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 2001-12-12, last modified: 2002-01-03
The ROSEBUD experiment for Direct Dark Matter detection settled in 1999 in
the Canfranc Underground Laboratory. The first phase of the experiment was
dedicated to the understanding and reduction of the radioactive background
following successive removals of the radioimpure materials. Sapphire (25g, 50g)
and germanium (67g) absorbers were used. Thresholds respectively lower than
1keV and 450 eV were achieved on these detectors. The second phase of the
experiment plans to use scintillating bolometers to discriminate between
recoiling nuclei and electrons. Prototypes using commercial CaWO4 (54g) and BGO
(46g) were designed for this purpose. While internal contamination was found
and identified in both targets, neutron calibrations revealed their high
discrimination power. A 6 keV threshold on the heat channel of the BGO
bolometer points out the interest of such a novel material, for Dark Matter
research on neutralinos having spin-dependent or spin-independent interactions.
[34]
oai:arXiv.org:hep-ex/0101037 [pdf] - 113338
Particle Dark Matter and Solar Axion Searches with a small germanium
detector at the Canfranc Underground Laboratory
Morales, A.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2001-01-22
A small, natural abundance, germanium detector (COSME) has been operating
recently at the Canfranc Underground Laboratory (Spanish Pyrenees) in improved
conditions of shielding and overburden with respect to a previous operation of
the same detector. An exposure of 72.7 kg day in these conditions has at
present a background improvement of about one order of magnitude compared to
the former operation of the detector. These new data have been applied to a
direct search for WIMPs and solar axions. New WIMP exclusion plots improving
the current bounds for low masses are reported. The paper also presents a limit
on the axion-photon coupling obtained from the analysis of the data looking for
a Primakoff axion-to-photon conversion and Bragg scattering inside the crystal.
[35]
oai:arXiv.org:hep-ph/0011318 [pdf] - 1507915
Recent results from the canfranc dark matter search with germanium
detectors
Irastorza, I. G.;
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Hensley, W. K.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2000-11-27
Two germanium detectors are currently operating in the Canfranc Underground
Laboratory at 2450 m.w.e looking for WIMP dark matter. One is a 2 kg 76Ge IGEX
detector (RG-2) which has an energy threshold of 4 keV and a low-energy
background rate of about 0.3 c/keV/kg/day. The other is a small (234 g) natural
abundance Ge detector (COSME), of low energy threshold (2.5 keV) and an energy
resolution of 0.4 keV at 10 keV which is looking for WIMPs and for solar
axions. The analysis of 73 kg-days of data taken by COSME in a search for solar
axions via their photon Primakoff conversion and Bragg scattering in the Ge
crystal yields a 95% C.L. limit for the axion-photon coupling g < 2.8 10^-9
GeV^-1. These data, analyzed for WIMP searches provide an exclusion plot for
WIMP-nucleon spin-independent interaction which improves previous plots in the
low mass region. On the other hand, the exclusion plot derived from the 60
kg-days of data from the RG-2 IGEX detector improves the exclusion limits
derived from other ionization (non thermal) germanium detector experiments in
the region of WIMP masses from 30 to 100 GeV recently singled out by the
reported DAMA annual modulation effect.
[36]
oai:arXiv.org:astro-ph/0004292 [pdf] - 362880
First results of the ROSEBUD Dark Matter experiment
Cebrian, S.;
Coron, N.;
Dambier, G.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Leblanc, J.;
de Marcillac, P.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2000-04-20
Rare Objects SEarch with Bolometers UndergrounD) is an experiment which
attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through
their elastic scattering off Al and O nuclei. It consists of three small
sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a
dilution refrigerator operating at 20 mK in the Canfranc Underground
Laboratory. We report in this paper the results of several runs (of about 10
days each) with successively improved energy thresholds, and the progressive
background reduction obtained by improvement of the radiopurity of the
components and subsequent modifications in the experimental assembly, including
the addition of old lead shields. Mid-term plans and perspectives of the
experiment are also presented.
[37]
oai:arXiv.org:hep-ex/0002053 [pdf] - 113328
New constraints on WIMPs from the Canfranc IGEX dark matter search
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Hensley, W. K.;
Irastorza, I. G.;
Kirpichnikov, I. V.;
Klimenko, A. A.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Osetrov, S. B.;
Pogosov, V. S.;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Smolnikov, A. A.;
Tamanyan, A. G.;
Vasenko, A. A.;
Vasiliev, S. I.;
Villar, J. A.
Submitted: 2000-02-21
The IGEX Collaboration enriched 76Ge double-beta decay detectors are
currently operating in the Canfranc Underground Laboratory with an overburden
of 2450 m.w.e. A recent upgrade has made it possible to use them in a search
for WIMPs. A new exclusion plot has been derived for WIMP-nucleon
spin-independent interaction. To obtain this result, 30 days of data from one
IGEX detector, which has an energy threshold of ~4 keV, have been considered.
These data improve the exclusion limits derived from other germanium diode
experiments in the ~50 GeV DAMA region, and show that with a moderate
improvement of the background below 10 keV, the DAMA region may be tested with
an additional 1 kg-year of exposure.
[38]
oai:arXiv.org:hep-ph/9912522 [pdf] - 116658
Sensitivity plots for WIMP modulation searches
Scopel, S.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 1999-12-28
Prospects of WIMP searches using the annual modulation signature are
discussed on statistical grounds, introducing sensitivity plots for the
WIMP-nucleon scalar cross section.
[39]
oai:arXiv.org:astro-ph/9912491 [pdf] - 110154
Prospects for solar axions searches with crystals via Bragg scattering
Irastorza, I. G.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 1999-12-23
A calculation of the expected signal due to Primakov coherent conversion of
solar axions into photons via Bragg scattering in several solid-state detectors
is presented and compared with present and future experimental sensitivities.
The axion window m_a > 0.03 eV (not accessible at present by other techniques)
could be explored in the foreseeable future with crystal detectors to constrain
the axion-photon coupling constant below the latest bounds coming from
helioseismology. On the contrary a positive signal in the sensitivity region of
such devices would imply revisiting other more stringent astrophysical limits
derived for the same range of the axion mass. The application of this technique
to the COSME germanium detector which is taking data at the Canfranc
Underground Laboratory leads to a 95% C.L. limit g_a < 2.8 10^-9 GeV^-1.
[40]
oai:arXiv.org:hep-ph/9912394 [pdf] - 899146
Sensitivity plots for WIMP direct detection using the annual modulation
signature
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 1999-12-17
Annual modulation due to the Earth's motion around the Sun is a well known
signature of the expected WIMP signal induced in a solid state underground
detector. In the present letter we discuss the prospects of this technique on
statistical grounds, introducing annual-modulation sensitivity plots for the
WIMP-nucleon scalar cross section for different materials and experimental
conditions. The highest sensitivity to modulation is found in the WIMP mass
interval 10 GeV< m_W < 130 GeV, the actual upper limit depending from the
choice of the astrophysical parameters, while the lowest values of the
explorable WIMP-nucleon elastic cross-sections fall in most cases within one
order of magnitude of the sensitivities of present direct detection WIMP
searches.
[41]
oai:arXiv.org:astro-ph/9811359 [pdf] - 103985
Prospects of solar axion searches with crystal detectors
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Salinas, A.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 1998-11-23
A calculation of the expected signal due to Primakoff coherent conversion of
solar axions into photons via Bragg scattering in several crystal detectors is
presented. The results are confronted with the experimental sensitivities of
present and future experiments concluding that the sensitivity of crystal
detectors does not challenge the globular cluster limit on the axion-photon
coupling g_a. In particular, in the axion mass window m_a ~> 0.03 eV explored
with this technique (not accessible at present by other methods) g_a might be
constrained down to 10^-9 GeV^-1 (the recent helioseismological bound) provided
that significant improvements in the parameters and performances of these
detectors be achieved and large statistics accumulated. This bound should be
considered as a minimal goal for the sensitivity of future crystal experiments.
Consequently, finding a positive signal at this level of sensitivity would
necessarily imply revisiting other more stringent astrophysical limits derived
for the same range of m_a values.
[42]
oai:arXiv.org:astro-ph/9810308 [pdf] - 103424
Theoretical expectations and experimental prospects for solar axions
searches with crystal detectors
Scopel, S.;
Irastorza, I. G.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Salinas, A.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 1998-10-20
A calculation of the expected signal due to Primakov coherent conversion of
solar axions into photons via Bragg scattering in several solid--state
detectors is presented and compared with present and future experimental
sensitivities. The axion window m_a>~0.03 eV (not accessible at present by
other techniques) could be explored in the foreseeable future with crystal
detectors to constrain the axion--photon coupling constant below the latest
bounds coming from helioseismology. On the contrary a positive signal in the
sensitivity region of such devices would imply revisiting other more stringent
astrophysical limits derived for the same range of the axion mass.