Normalized to: Illa, J.
[1]
oai:arXiv.org:1902.03623 [pdf] - 1916810
The Physics of the Accelerating Universe Camera
Padilla, Cristobal;
Castander, Francisco J.;
Alarcon, Alex;
Aleksic, Jelena;
Ballester, Otger;
Cabayol, Laura;
Cardiel-Sas, Laia;
Carretero, Jorge;
Casas, Ricard;
Castilla, Javier;
Crocce, Martin;
Delfino, Manuel;
Diaz, Carlos;
Eriksen, Martin;
Fernandez, Enrique;
Fosalba, Pablo;
Garcia-Bellido, Juan;
Gaztanaga, Enrique;
Gaweda, Javier;
Granena, Ferran;
Illa, Jose Maria;
Jimenez, Jorge;
Lopez, Luis;
Marti, Pol;
Miquel, Ramon;
Neissner, Christian;
Pio, Cristobal;
Sanchez, Eusebio;
Serrano, Santiago;
Sevilla-Noarbe, Ignacio;
Tallada, Pau;
Tonello, Nadia;
de Vicente, Juan
Submitted: 2019-02-10, last modified: 2019-03-28
The PAU (Physics of the Accelerating Universe) Survey goal is to obtain
photometric redshifts (photo-z) and Spectral Energy Distribution (SED) of
astronomical objects with a resolution roughly one order of magnitude better
than current broad band photometric surveys. To accomplish this, a new large
field of view camera (PAUCam) has been designed, built, commissioned and is now
operated at the William Herschel Telescope (WHT). With the current WHT Prime
Focus corrector, the camera covers ~1-degree diameter Field of View (FoV), of
which, only the inner ~40 arcmin diameter are unvignetted. The focal plane
consists of a mosaic of 18 2k$x4k Hamamatsu fully depleted CCDs, with high
quantum efficiency up to 1 micrometers in wavelength. To maximize the detector
coverage within the FoV, filters are placed in front of the CCDs inside the
camera cryostat (made out of carbon fiber) using a challenging movable tray
system. The camera uses a set of 40 narrow band filters ranging from ~4500 to
~8500 Angstroms complemented with six standard broad-band filters, ugrizY. The
PAU Survey aims to cover roughly 100 square degrees over fields with existing
deep photometry and galaxy shapes to obtain accurate photometric redshifts for
galaxies down to i_AB~22.5, detecting also galaxies down to i_AB~24 with less
precision in redshift. With this data set we will be able to measure intrinsic
alignments, galaxy clustering and perform galaxy evolution studies in a new
range of densities and redshifts. Here, we describe the PAU camera, its first
commissioning results and performance.
[2]
oai:arXiv.org:1710.08875 [pdf] - 1676747
ProtoDESI: First On-Sky Technology Demonstration for the Dark Energy
Spectroscopic Instrument
Fagrelius, Parker;
Abareshi, Behzad;
Allen, Lori;
Ballester, Otger;
Baltay, Charles;
Besuner, Robert;
Buckley-Geer, Elizabeth;
Butler, Karen;
Cardiel, Laia;
Dey, Arjun;
Elliott, Ann;
Emmet, William;
Gershkovich, Irena;
Honscheid, Klaus;
Illa, Jose M.;
Jimenez, Jorge;
Levi, Michael;
Manser, Christopher;
Marshall, Robert;
Martini, Paul;
Paat, Anthony;
Probst, Ronald;
Rabinowitz, David;
Reil, Kevin;
Robertson, Amy;
Rockosi, Connie;
Schlegel, David;
Schubnell, Michael;
Serrano, Santiago;
Silber, Joseph;
Soto, Christian;
Sprayberry, David;
Summers, David;
Tarle, Greg;
Weaver, Benjamin A.;
Duan, Y. T.
Submitted: 2017-10-24, last modified: 2018-05-02
The Dark Energy Spectroscopic Instrument (DESI) is under construction to
measure the expansion history of the universe using the baryon acoustic
oscillations technique. The spectra of 35 million galaxies and quasars over
14,000 square degrees will be measured during a 5-year survey. A new prime
focus corrector for the Mayall telescope at Kitt Peak National Observatory will
deliver light to 5,000 individually targeted fiber-fed robotic positioners. The
fibers in turn feed ten broadband multi-object spectrographs. We describe the
ProtoDESI experiment, that was installed and commissioned on the 4-m Mayall
telescope from August 14 to September 30, 2016. ProtoDESI was an on-sky
technology demonstration with the goal to reduce technical risks associated
with aligning optical fibers with targets using robotic fiber positioners and
maintaining the stability required to operate DESI. The ProtoDESI prime focus
instrument, consisting of three fiber positioners, illuminated fiducials, and a
guide camera, was installed behind the existing Mosaic corrector on the Mayall
telescope. A Fiber View Camera was mounted in the Cassegrain cage of the
telescope and provided feedback metrology for positioning the fibers. ProtoDESI
also provided a platform for early integration of hardware with the DESI
Instrument Control System that controls the subsystems, provides communication
with the Telescope Control System, and collects instrument telemetry data.
Lacking a spectrograph, ProtoDESI monitored the output of the fibers using a
Fiber Photometry Camera mounted on the prime focus instrument. ProtoDESI was
successful in acquiring targets with the robotically positioned fibers and
demonstrated that the DESI guiding requirements can be met.
[4]
oai:arXiv.org:1709.00239 [pdf] - 1587792
Light-Trap: A SiPM Upgrade for Very High Energy Astronomy and Beyond
Guberman, D.;
Cortina, J.;
Ward, J. E.;
Hahn, A.;
Mazin, D.;
Boix, J.;
Dettlaff, A.;
Fink, D.;
Gaweda, J.;
Haberer, W.;
Illa, J.;
Mundet, J.;
Vera, Y.;
Wetteskind, H.
Submitted: 2017-09-01
With the development of the Imaging Atmospheric Cherenkov Technique (IACT),
Gamma-ray astronomy has become one of the most interesting and productive
fields of astrophysics. Current IACT telescope arrays (MAGIC, H.E.S.S, VERITAS)
use photomultiplier tubes (PMTs) to detect the optical/near-UV Cherenkov
radiation emitted due to the interaction of gamma rays with the atmosphere. For
the next generation of IACT experiments, the possibility of replacing the PMTs
with Silicon photomultipliers (SiPMs) is being studied. Among the main
drawbacks of SiPMs are their limited active area (leading to an increase in the
cost and complexity of the camera readout) and their sensitivity to unwanted
wavelengths. Here we propose a novel method to build a relatively low-cost
pixel consisting of a SiPM attached to a PMMA disc doped with a wavelength
shifter. This pixel collects light over a much larger area than a single
standard SiPM and improves sensitivity to near-UV light while simultaneously
rejecting background. We describe the design of a detector that could also have
applications in other fields where detection area and cost are crucial. We
present results of simulations and laboratory measurements of a pixel prototype
and from field tests performed with a 7-pixel cluster installed in a MAGIC
telescope camera.
[7]
oai:arXiv.org:1409.6073 [pdf] - 986943
The major upgrade of the MAGIC telescopes, Part I: The hardware
improvements and the commissioning of the system
MAGIC Collaboration;
Aleksic, J.;
Ansoldi, S.;
Antonelli, L. A.;
Antoranz, P.;
Babic, A.;
Bangale, P.;
Barcelo, M.;
Barrio, J. A.;
Gonzalez, J. Becerra;
Bednarek, W.;
Bernardini, E.;
Biasuzzi, B.;
Biland, A.;
Bitossi, M.;
Blanch, O.;
Bonnefoy, S.;
Bonnoli, G.;
Borracci, F.;
Bretz, T.;
Carmona, E.;
Carosi, A.;
Cecchi, R.;
Colin, P.;
Colombo, E.;
Contreras, J. L.;
Corti, D.;
Cortina, J.;
Covino, S.;
Da Vela, P.;
Dazzi, F.;
De Angelis, A.;
De Caneva, G.;
De Lotto, B.;
Wilhelmi, E. de Ona;
Mendez, C. Delgado;
Dettlaff, A.;
Prester, D. Dominis;
Dorner, D.;
Doro, M.;
Einecke, S.;
Eisenacher, D.;
Elsaesser, D.;
Fidalgo, D.;
Fink, D.;
Fonseca, M. V.;
Font, L.;
Frantzen, K.;
Fruck, C.;
Galindo, D.;
Lopez, R. J. Garcia;
Garczarczyk, M.;
Terrats, D. Garrido;
Gaug, M.;
Giavitto, G.;
Godinovic, N.;
Munoz, A. Gonzalez;
Gozzini, S. R.;
Haberer, W.;
Hadasch, D.;
Hanabata, Y.;
Hayashida, M.;
Herrera, J.;
Hildebrand, D.;
Hose, J.;
Hrupec, D.;
Idec, W.;
Illa, J. M.;
Kadenius, V.;
Kellermann, H.;
Knoetig, M. L.;
Kodani, K.;
Konno, Y.;
Krause, J.;
Kubo, H.;
Kushida, J.;
La Barbera, A.;
Lelas, D.;
Lemus, J. L.;
Lewandowska, N.;
Lindfors, E.;
Lombardi, S.;
Longo, F.;
Lopez, M.;
Lopez-Coto, R.;
Lopez-Oramas, A.;
Lorca, A.;
Lorenz, E.;
Lozano, I.;
Makariev, M.;
Mallot, K.;
Maneva, G.;
Mankuzhiyil, N.;
Mannheim, K.;
Maraschi, L.;
Marcote, B.;
Mariotti, M.;
Martinez, M.;
Mazin, D.;
Menzel, U.;
Miranda, J. M.;
Mirzoyan, R.;
Moralejo, A.;
Munar-Adrover, P.;
Nakajima, D.;
Negrello, M.;
Neustroev, V.;
Niedzwiecki, A.;
Nilsson, K.;
Nishijima, K.;
Noda, K.;
Orito, R.;
Overkemping, A.;
Paiano, S.;
Palatiello, M.;
Paneque, D.;
Paoletti, R.;
Paredes, J. M.;
Paredes-Fortuny, X.;
Persic, M.;
Poutanen, J.;
Moroni, P. G. Prada;
Prandini, E.;
Puljak, I.;
Reinthal, R.;
Rhode, W.;
Ribo, M.;
Rico, J.;
Garcia, J. Rodriguez;
Rugamer, S.;
Saito, T.;
Saito, K.;
Satalecka, K.;
Scalzotto, V.;
Scapin, V.;
Schultz, C.;
Schlammer, J.;
Schmidl, S.;
Schweizer, T.;
Sillanpaa, A.;
Sitarek, J.;
Snidaric, I.;
Sobczynska, D.;
Spanier, F.;
Stamerra, A.;
Steinbring, T.;
Storz, J.;
Strzys, M.;
Takalo, L.;
Takami, H.;
Tavecchio, F.;
Tejedor, L. A.;
Temnikov, P.;
Terzic, T.;
Tescaro, D.;
Teshima, M.;
Thaele, J.;
Tibolla, O.;
Torres, D. F.;
Toyama, T.;
Treves, A.;
Vogler, P.;
Wetteskind, H.;
Will, M.;
Zanin, R.
Submitted: 2014-09-21, last modified: 2015-04-30
The MAGIC telescopes are two Imaging Atmospheric Cherenkov Telescopes (IACTs)
located on the Canary island of La Palma. The telescopes are designed to
measure Cherenkov light from air showers initiated by gamma rays in the energy
regime from around 50 GeV to more than 50 TeV. The two telescopes were built in
2004 and 2009, respectively, with different cameras, triggers and readout
systems. In the years 2011-2012 the MAGIC collaboration undertook a major
upgrade to make the stereoscopic system uniform, improving its overall
performance and easing its maintenance. In particular, the camera, the
receivers and the trigger of the first telescope were replaced and the readout
of the two telescopes was upgraded. This paper (Part I) describes the details
of the upgrade as well as the basic performance parameters of MAGIC such as raw
data treatment, dead time of the system, linearity in the electronic chain and
sources of noise. In Part II, we describe the physics performance of the
upgraded system.
[8]
oai:arXiv.org:1409.5594 [pdf] - 938161
The major upgrade of the MAGIC telescopes, Part II: A performance study
using observations of the Crab Nebula
MAGIC Collaboration;
Aleksic, J.;
Ansoldi, S.;
Antonelli, L. A.;
Antoranz, P.;
Babic, A.;
Bangale, P.;
Barcelo, M.;
Barrio, J. A.;
Gonzalez, J. Becerra;
Bednarek, W.;
Bernardini, E.;
Biasuzzi, B.;
Biland, A.;
Bitossi, M.;
Blanch, O.;
Bonnefoy, S.;
Bonnoli, G.;
Borracci, F.;
Bretz, T.;
Carmona, E.;
Carosi, A.;
Cecchi, R.;
Colin, P.;
Colombo, E.;
Contreras, J. L.;
Corti, D.;
Cortina, J.;
Covino, S.;
Da Vela, P.;
Dazzi, F.;
De Angelis, A.;
De Caneva, G.;
De Lotto, B.;
Wilhelmi, E. de Ona;
Mendez, C. Delgado;
Dettlaff, A.;
Prester, D. Dominis;
Dorner, D.;
Doro, M.;
Einecke, S.;
Eisenacher, D.;
Elsaesser, D.;
Fidalgo, D.;
Fink, D.;
Fonseca, M. V.;
Font, L.;
Frantzen, K.;
Fruck, C.;
Galindo, D.;
Lopez, R. J. Garcia;
Garczarczyk, M.;
Terrats, D. Garrido;
Gaug, M.;
Giavitto, G.;
Godinovic, N.;
Munoz, A. Gonzalez;
Gozzini, S. R.;
Haberer, W.;
Hadasch, D.;
Hanabata, Y.;
Hayashida, M.;
Herrera, J.;
Hildebrand, D.;
Hose, J.;
Hrupec, D.;
Idec, W.;
Illa, J. M.;
Kadenius, V.;
Kellermann, H.;
Knoetig, M. L.;
Kodani, K.;
Konno, Y.;
Krause, J.;
Kubo, H.;
Kushida, J.;
La Barbera, A.;
Lelas, D.;
Lemus, J. L.;
Lewandowska, N.;
Lindfors, E.;
Lombardi, S.;
Longo, F.;
Lopez, M.;
Lopez-Coto, R.;
Lopez-Oramas, A.;
Lorca, A.;
Lorenz, E.;
Lozano, I.;
Makariev, M.;
Mallot, K.;
Maneva, G.;
Mankuzhiyil, N.;
Mannheim, K.;
Maraschi, L.;
Marcote, B.;
Mariotti, M.;
Martinez, M.;
Mazin, D.;
Menzel, U.;
Miranda, J. M.;
Mirzoyan, R.;
Moralejo, A.;
Munar-Adrover, P.;
Nakajima, D.;
Negrello, M.;
Neustroev, V.;
Niedzwiecki, A.;
Nilsson, K.;
Nishijima, K.;
Noda, K.;
Orito, R.;
Overkemping, A.;
Paiano, S.;
Palatiello, M.;
Paneque, D.;
Paoletti, R.;
Paredes, J. M.;
Paredes-Fortuny, X.;
Persic, M.;
Poutanen, J.;
Moroni, P. G. Prada;
Prandini, E.;
Puljak, I.;
Reinthal, R.;
Rhode, W.;
Ribo, M.;
Rico, J.;
Garcia, J. Rodriguez;
Rugamer, S.;
Saito, T.;
Saito, K.;
Satalecka, K.;
Scalzotto, V.;
Scapin, V.;
Schultz, C.;
Schlammer, J.;
Schmidl, S.;
Schweizer, T.;
Shore, S. N.;
Sillanpaa, A.;
Sitarek, J.;
Snidaric, I.;
Sobczynska, D.;
Spanier, F.;
Stamerra, A.;
Steinbring, T.;
Storz, J.;
Strzys, M.;
Takalo, L.;
Takami, H.;
Tavecchio, F.;
Tejedor, L. A.;
Temnikov, P.;
Terzic, T.;
Tescaro, D.;
Teshima, M.;
Thaele, J.;
Tibolla, O.;
Torres, D. F.;
Toyama, T.;
Treves, A.;
Vogler, P.;
Wetteskind, H.;
Will, M.;
Zanin, R.
Submitted: 2014-09-19, last modified: 2015-02-20
MAGIC is a system of two Imaging Atmospheric Cherenkov Telescopes located in
the Canary island of La Palma, Spain. During summer 2011 and 2012 it underwent
a series of upgrades, involving the exchange of the MAGIC-I camera and its
trigger system, as well as the upgrade of the readout system of both
telescopes. We use observations of the Crab Nebula taken at low and medium
zenith angles to assess the key performance parameters of the MAGIC stereo
system. For low zenith angle observations, the standard trigger threshold of
the MAGIC telescopes is ~50GeV. The integral sensitivity for point-like sources
with Crab Nebula-like spectrum above 220GeV is (0.66+/-0.03)% of Crab Nebula
flux in 50 h of observations. The angular resolution, defined as the sigma of a
2-dimensional Gaussian distribution, at those energies is < 0.07 degree, while
the energy resolution is 16%. We also re-evaluate the effect of the systematic
uncertainty on the data taken with the MAGIC telescopes after the upgrade. We
estimate that the systematic uncertainties can be divided in the following
components: < 15% in energy scale, 11-18% in flux normalization and +/-0.15 for
the energy spectrum power-law slope.
[9]
oai:arXiv.org:1410.5070 [pdf] - 884642
Towards SiPM camera for current and future generations of Cherenkov
telescopes
Mazin, Daniel;
Bangale, Priyadarshini;
Sitarek, Julian;
Cortina, Juan;
Fink, David;
Hose, Jürgen;
Illa, Jose Maria;
Lorenz, Eckart;
Martínez, Manel;
Menzel, Uta;
Mirzoyan, Razmik;
Teshima, Masahiro
Submitted: 2014-10-19
So far the current ground-based Imaging Atmospheric Cherenkov Telescopes
(IACTs) have energy thresholds in the best case in the range of ~30 to 50 GeV
(H.E.S.S. II and MAGIC telescopes). Lowest energy gamma-ray showers produce low
light intensity images and cannot be efficiently separated from dominating
images from hadronic background. A cost effective way of improving the
telescope performance at lower energies is to use novel photosensors with
superior photon detection efficiency (PDE). Currently the best commercially
available superbialkali photomultipliers (PMTs) have a PDE of about 30-33%,
whereas the silicon photomultipliers (SiPMs, also known as MPPC, GAPD) from
some manufacturers show a photon detection efficiency of about 40-45%. Using
these devices can lower the energy threshold of the instrument and may improve
the background rejection due to intrinsic properties of SiPMs such as a superb
single photoelectron resolution. Compared to PMTs, SiPMs are more compact, fast
in response, operate at low voltage, and are insensitive to magnetic fields.
SiPMs can be operated at high background illumination, which would allow to
operate the IACT also during partial moonlight, dusk and dawn, hence increasing
the instrument duty cycle. We are testing the SiPMs for Cherenkov telescopes
such as MAGIC and CTA. Here we present an overview of our setup and first
measurements, which we perform in two independent laboratories, in Munich,
Germany and in Barcelona, Spain.
[11]
oai:arXiv.org:0907.0466 [pdf] - 1934367
The readout system of the MAGIC-II Cherenkov Telescope
Tescaro, D.;
Aleksic, J.;
Barcelo, M.;
Bitossi, M.;
Cortina, J.;
Fras, M.;
Hadasch, D.;
Illa, J. M.;
Martinez, M.;
Mazin, D.;
Paoletti, R.;
Pegna, R.
Submitted: 2009-07-02
In this contribution we describe the hardware, firmware and software
components of the readout system of the MAGIC-II Cherenkov telescope on the
Canary island La Palma. The PMT analog signals are transmitted by means of
optical fibers from the MAGIC-II camera to the 80 m away counting house where
they are routed to the new high bandwidth and fully programmable receiver
boards (MONSTER), which convert back the signals from optical to electrical
ones. Then the signals are split, one half provide the input signals for the
level ONE trigger system while the other half is sent to the digitizing units.
The fast Cherenkov pulses are sampled by low-power Domino Ring Sampler chips
(DRS2) and temporarily stored in an array of 1024 capacitors. Signals are
sampled at the ultra-fast speed of 2 GSample/s, which allows a very precise
measurement of the signal arrival times in all pixels. They are then digitized
with 12-bit resolution by an external ADC readout at 40 MHz speed. The Domino
samplers are integrated in the newly designed mezzanines which equip a set of
fourteen multi-purpose PULSAR boards. Finally, the data are sent through an
S-LINK optical interface to a single computer. The entire DAQ hardware is
controlled through a VME interface and steered by the slow control software
program (MIR). The Data AcQuisition software program (DAQ) proceeds finally to
the event building and data storage.