Normalized to: Ikagawa, T.
[1]
oai:arXiv.org:astro-ph/0604365 [pdf] - 81434
Design and Performance of the Soft Gamma-ray Detector for the NeXT
mission
Tajima, H.;
Kamae, T.;
Madejski, G.;
Mitani, T.;
Nakazawa, K.;
Tanaka, T.;
Takahashi, T.;
Watanabe, S.;
Fukazawa, Y.;
Ikagawa, T.;
Kataoka, J.;
Kokubun, M.;
Makishima, K.;
Terada, Y.;
Nomachi, M.;
Tashiro, M.
Submitted: 2006-04-17
The Soft Gamma-ray Detector (SGD) on board the NeXT (Japanese future high
energy astrophysics mission) is a Compton telescope with narrow field of view
(FOV), which utilizes Compton kinematics to enhance its background rejection
capabilities. It is realized as a hybrid semiconductor gamma-ray detector which
consists of silicon and CdTe (cadmium telluride) detectors. It can detect
photons in a wide energy band (0.05-1 MeV) at a background level of 5 x 10^-7
counts/cm^2/s; the silicon layers are required to improve the performance at a
lower energy band (<0.3 MeV). Excellent energy resolution is the key feature of
the SGD, allowing it to achieve both high angular resolution and good
background rejection capability. An additional capability of the SGD, its
ability to measure gamma-ray polarization, opens up a new window to study
properties of astronomical objects. We will present the development of key
technologies to realize the SGD: high quality CdTe, low noise front-end ASIC
and bump bonding technology. Energy resolutions of 1.7 keV (FWHM) for CdTe
pixel detectors and 1.1 keV for Si strip detectors have been measured. We also
present the validation of Monte Carlo simulation used to evaluate the
performance of the SGD.
[2]
oai:arXiv.org:astro-ph/0602391 [pdf] - 79967
Recent progress of avalanche photodiodes in high-resolution X-rays and
Gamma-rays detection
Kataoka, J.;
Saito, T.;
Kuramoto, Y.;
Ikagawa, T.;
Yatsu, Y.;
Kotoku, J.;
Arimoto, M.;
Kawai, N.;
Ishikawa, Y.;
Kawabata, N.
Submitted: 2006-02-17
We have studied the performance of large area avalanche photodiodes (APDs)
recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and
Gamma-rays detections. We show that reach-through APD can be an excellent soft
X-ray detector operating at room temperature or moderately cooled environment.
We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV
X-rays, and obtain the energy threshold as low as 0.5 keV measured at -20deg.
Thanks to its fast timing response, signal carriers in the APD device are
collected within a short time interval of 1.9 nsec (FWHM). This type of APDs
can therefore be used as a low-energy, high-counting particle monitor onboard
the forthcoming Pico-satellite Cute1.7. As a scintillation photon detector,
reverse-type APDs have a good advantage of reducing the dark noise
significantly. The best FWHM energy resolutions of 9.4+-0.3 % and 4.9+-0.2 %
were obtained for 59.5 keV and 662 keV Gamma-rays, respectively, as measured
with a CsI(Tl) crystal. Combination of APDs with various other scintillators
(BGO, GSO, and YAP) also showed better results than that obtained with a
photomultiplier tube (PMT). These results suggest that APD could be a promising
device for replacing traditional PMT usage in some applications. In particular
2-dim APD array, which we present in this paper, will be a promising device for
a wide-band X-ray and Gamma-ray imaging detector in future space research and
nuclear medicine.
[3]
oai:arXiv.org:astro-ph/0602392 [pdf] - 79968
An Active Gain-control System for Avalanche Photo-Diodes under Moderate
Temperature Variations
Kataoka, J.;
Sato, R.;
Ikagawa, T.;
Kotoku, J.;
Kuramoto, Y.;
Tsubuku, Y.;
Saito, T.;
Yatsu, Y.;
Kawai, N.;
Ishikawa, Y.;
Kawabata, N.
Submitted: 2006-02-17
Avalanche photodiodes (APDs) are promising light sensor for various fields of
experimental physics. It has been argued, however, that variation of APD gain
with temperature could be a serious problem preventing APDs from replacing
traditional photomultiplier tubes (PMTs) in some applications. Here we develop
an active gain-control system to keep the APD gain stable under moderate
temperature variations. As a performance demonstration of the proposed system,
we have tested the response of a scintillation photon detector consisting of a
5x5 mm^2 reverse-type APD optically coupled with a CsI(Tl) crystal. We show
that the APD gain was successfully controlled under a temperature variation of
DT = 20deg, within a time-cycle of 6000 sec. The best FWHM energy resolution of
6.1+-0.2 % was obtained for 662 keV gamma-rays, and the energy threshold was as
low as 6.5 keV, by integrating data from +20deg - 0deg cycles. The
corresponding values for -20deg - 0deg cycles were 6.9+-0.2 % and 5.2 keV,
respectively. These results are comparable, or only slightly worse than that
obtained at a fixed temperature. Our results suggest new potential uses for
APDs in various space researches and nuclear physics. As examples, we briefly
introduce the NeXT and Cute-1.7 satellite missions that will carry the APDs as
scientific instruments for the first time.