Normalized to: Iguaz, F.
[1]
oai:arXiv.org:1812.04519 [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Dafni, T.;
Galan, J.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Mirallas, H.;
de Solorzano, A. Ortiz;
Ruiz-Choliz, E.
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive
Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas
readout planes at the Canfranc Underground Laboratory. The detector can hold in
the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30
kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered
acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low
background level in the lowest energy region is another essential requirement.
To assess the expected background, all the relevant sources have been
considered, including the measured fluxes of gamma radiation, muons and
neutrons at the Canfranc Laboratory, together with the activity of most of the
components used in the detector and ancillary systems, obtained in a complete
assay program. The background contributions have been simulated by means of a
dedicated application based on Geant4 and a custom-made code for the detector
response. The background model developed for the detector presently installed
in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region
of interest, making TREX-DM competitive in the search for low-mass WIMPs. A
roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[2]
oai:arXiv.org:1906.01084 [pdf] - 1894436
First Results on the Search for Chameleons with the KWISP Detector at
CAST
Cuendis, S. Arguedas;
Baier, J.;
Barth, K.;
Baum, S.;
Bayirli, A.;
Belov, A.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Castel, J. F.;
Cetin, S. A.;
Dafni, T.;
Davenport, M.;
Dermenev, A.;
Desch, K.;
Döbrich, B.;
Fischer, H.;
Funk, W.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gninenko, S.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakovčić, K.;
Kaminski, J.;
Karuza, M.;
Krieger, C.;
Lakić, B.;
Laurent, J. M.;
Luzón, G.;
Maroudas, M.;
Miceli, L.;
Neff, S.;
Ortega, I.;
Ozbey, A.;
Pivovaroff, M. J.;
Rosu, M.;
Ruz, J.;
Chóliz, E. Ruiz;
Schmidt, S.;
Schumann, M.;
Semertzidis, Y. K.;
Solanki, S. K.;
Stewart, L.;
Tsagris, I.;
Vafeiadis, T.;
Vogel, J. K.;
Vretenar, M.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2019-06-03
We report on a first measurement with a sensitive opto-mechanical force
sensor designed for the direct detection of coupling of real chameleons to
matter. These dark energy candidates could be produced in the Sun and stream
unimpeded to Earth. The KWISP detector installed on the CAST axion search
experiment at CERN looks for tiny displacements of a thin membrane caused by
the mechanical effect of solar chameleons. The displacements are detected by a
Michelson interferometer with a homodyne readout scheme. The sensor benefits
from the focusing action of the ABRIXAS X-ray telescope installed at CAST,
which increases the chameleon flux on the membrane. A mechanical chopper placed
between the telescope output and the detector modulates the incoming chameleon
stream. We present the results of the solar chameleon measurements taken at
CAST in July 2017, setting an upper bound on the force acting on the membrane
of $80$~pN at 95\% confidence level. The detector is sensitive for direct
coupling to matter $10^4 \leq\beta_m \leq 10^8$, where the coupling to photons
is locally bound to $\beta_\gamma \leq 10^{11}$.
[3]
oai:arXiv.org:1811.09290 [pdf] - 1842424
Weighing the Solar Axion
Dafni, Theopisti;
O'Hare, Ciaran A. J.;
Lakić, Biljana;
Galán, Javier;
Iguaz, Francisco J.;
Irastorza, Igor G.;
Jakovčić, Krešimir;
Luzón, Gloria;
Redondo, Javier;
Chóliz, Elisa Ruiz
Submitted: 2018-11-22, last modified: 2019-02-20
Axion helioscopes search for solar axions and axion-like particles via
inverse Primakoff conversion in strong laboratory magnets pointed at the Sun.
While helioscopes can always measure the axion coupling to photons, the
conversion signal is independent of the mass for axions lighter than around
0.02 eV. Masses above this value on the other hand have suppressed signals due
to axion-photon oscillations which destroy the coherence of the conversion
along the magnet. However, the spectral oscillations present in the axion
conversion signal between these two regimes are highly dependent on the axion
mass. We show that these oscillations are observable given realistic energy
resolutions and can be used to determine the axion mass to within percent level
accuracies. Using projections for the upcoming helioscope IAXO, we demonstrate
that $>3\sigma$ sensitivity to a non-zero axion mass is possible between $3
\times 10^{-3}$ and $10^{-1}$ eV for both the Primakoff and axion-electron
solar fluxes.
[4]
oai:arXiv.org:1706.05818 [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Amare, J.;
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Cuesta, C.;
Dafni, T.;
Galan, J.;
Garcia, E.;
Garza, J. G.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Martinez, M.;
Mirallas, H.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Ruiz-Choliz, E.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background
conditions at energies below a few tens of keV. Radioactive isotopes are
produced via cosmogenic activation in detectors and other materials and those
isotopes constitute a background source which has to be under control. In
particular, tritium is specially relevant due to its decay properties (very low
endpoint energy and long half-life) when induced in the detector medium, and
because it can be generated in any material as a spallation product.
Quantification of cosmogenic production of tritium is not straightforward,
neither experimentally nor by calculations. In this work, a method for the
calculation of production rates at sea level has been developed and applied to
some of the materials typically used as targets in dark matter detectors
(germanium, sodium iodide, argon and neon); it is based on a selected
description of tritium production cross sections over the entire energy range
of cosmic nucleons. Results have been compared to available data in the
literature, either based on other calculations or from measurements. The
obtained tritium production rates, ranging from a few tens to a few hundreds of
nuclei per kg and per day at sea level, point to a significant contribution to
the background in dark matter experiments, requiring the application of
specific protocols for target material purification, material storing
underground and limiting the time the detector is on surface during the
building process in order to minimize the exposure to the most dangerous cosmic
ray components.
[5]
oai:arXiv.org:1709.10062 [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Aznar, F;
Castel, J;
Cebrian, S;
Coarasa, I;
Dafni, T;
Galan, J;
Garza, JG;
Iguaz, FJ;
Irastorza, IG;
Luzon, G;
Mirallas, H;
de Solorzano, A Ortiz;
Ruiz-Choliz, E;
Villar, JA
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a
gas time projection chamber equipped with novel micromegas readout planes at
the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized
gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg
of Ne. The micromegas will be read with a self-triggered acquisition, allowing
for effective thresholds below 0.4 keV (electron equivalent). The preliminary
background model, following a complete material screening program, points to
levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest,
making TREX-DM competitive. The status of the commissioning, description of the
background model and the corresponding WIMP sensitivity will be presented here.
[6]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[7]
oai:arXiv.org:1503.04561 [pdf] - 1376478
Search for chameleons with CAST
Anastassopoulos, V.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Christensen, F.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Desch, K.;
Dermenev, A.;
Eleftheriadis, C.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Hailey, C.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakobsen, A.;
Jakovčić, K.;
Kaminski, J.;
Karuza, M.;
Kavuk, M.;
Krčmar, M.;
Krieger, C.;
Krüger, A.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Luzón, G.;
Neff, S.;
Ortega, I.;
Papaevangelou, T.;
Pivovarov, M. J.;
Raffelt, G.;
Riege, H.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Solanki, S. K.;
Vafeiadis, T.;
Villar, J. A.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.;
Brax, P.;
Lavrentyev, I.;
Upadhye, A.
Submitted: 2015-03-16, last modified: 2016-03-18
In this work we present a search for (solar) chameleons with the CERN Axion
Solar Telescope (CAST). This novel experimental technique, in the field of dark
energy research, exploits both the chameleon coupling to matter ($\beta_{\rm
m}$) and to photons ($\beta_{\gamma}$) via the Primakoff effect. By reducing
the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV
CAST became sensitive to the converted solar chameleon spectrum which peaks
around 600$\,$eV. Even though we have not observed any excess above background,
we can provide a 95% C.L. limit for the coupling strength of chameleons to
photons of $\beta_{\gamma}\!\lesssim\!10^{11}$ for $1<\beta_{\rm m}<10^6$.
[8]
oai:arXiv.org:1509.06190 [pdf] - 1323484
A Micromegas-based low-background x-ray detector coupled to a
slumped-glass telescope for axion research
Aznar, F.;
Castel, J.;
Christensen, F. E.;
Dafni, T.;
Decker, T. A.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Giomataris, I.;
Gracia, J. G.;
Hailey, C. J.;
Hill, R. M.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakobsen, A. C.;
Luzon, G.;
Mirallas, H.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Ruz, J.;
Vafeiadis, T.;
Vogel, J. K.
Submitted: 2015-09-21
We report on the design, construction and operation of a low background x-ray
detection line composed of a shielded Micromegas (micromesh gaseous structure)
detector of the microbulk technique. The detector is made from radiopure
materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m
focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of
thermally-formed (or "slumped") glass substrates deposited with multilayer
coatings. The system has been conceived as a technological pathfinder for the
future International Axion Observatory (IAXO), as it combines two of the
techniques (optic and detector) proposed in the conceptual design of the
project. It is innovative for two reasons: it is the first time an x-ray optic
has been designed and fabricated specifically for axion research, and the first
time a Micromegas detector has been operated with an x-ray optic. The line has
been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and
is currently looking for solar axions. The combination of the XRT and
Micromegas detector provides the best signal-to-noise ratio obtained so far by
any detection system of the CAST experiment with a background rate of
5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and
signal spot area.
[9]
oai:arXiv.org:1508.03006 [pdf] - 1330987
Exploring 0.1-10$\,$eV axions with a new helioscope concept
Galán, J.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Iguaz, F. J.;
Irastorza, I. G.;
García, J. A.;
Gracia, J.;
Luzón, G.;
Papaevangelou, T.;
Redondo, J.;
Tomás, A.
Submitted: 2015-08-12, last modified: 2015-09-07
We explore the possibility to develop a new axion helioscope type, sensitive
to the higher axion mass region favored by axion models. We propose to use a
low background large volume TPC immersed in an intense magnetic field. Contrary
to traditional tracking helioscopes, this detection technique takes advantage
of the capability to directly detect the photons converted on the buffer gas
which defines the axion mass sensitivity region, and does not require pointing
the magnet to the Sun. The operation flexibility of a TPC to be used with
different gas mixtures (He, Ne, Xe, etc) and pressures (from 10 mbar to 10 bar)
will allow to enhance sensitivity for axion masses from few meV to several eV.
We present different helioscope data taking scenarios, considering detection
efficiency and axion absorption probability, and show the sensitivities
reachable with this technique to be few $\times$ 10$^{-11}\,$GeV$^{-1}$ for a
5$\,$T$\,$m$^3$ scale TPC. We show that a few years program taking data with
such setup would allow to probe the KSVZ axion model for axion masses above 100
meV.
[10]
oai:arXiv.org:1501.01626 [pdf] - 918886
Characterization of a Spherical Proportional Counter in argon-based
mixtures
Submitted: 2015-01-07
The Spherical Proportional Counter is a novel type of radiation detector,
with a low energy threshold (typically below 100 eV) and good energy
resolution. This detector is being developed by the network NEWS, which
includes several applications. We can name between many others Dark Matter
searches, low level radon and neutron counting or low energy neutrino detection
from supernovas or nuclear reactors via neutrino-nucleus elastic scattering. In
this context, this works will present the characterization of a spherical
detector of 1 meter diameter using two argon-based mixtures (with methane and
isobutane) and for gas pressures between 50 and 1250 mbar. In each case, the
energy resolution shows its best value in a wide range of gains, limited by the
ballistic effect at low gains and by ion-backflow at high gains. Moreover, the
best energy resolution shows a degradation with pressure. These effects will be
discussed in terms of gas avalanche properties. Finally, the effect of an
electrical field corrector in the homogenity of the gain and the energy
threshold measured in our setup will be also discussed.
[11]
oai:arXiv.org:1501.01456 [pdf] - 1937998
Axion helioscopes update: the status of CAST and IAXO
Submitted: 2015-01-07
Almost 35 years since their suggestion as a good solution to the strong
CP-problem, axions remain one of the few viable candidates for the Dark Matter,
although still eluding detection. Most of the methods for their detection are
based on their coupling to photons, one of the most sensitive ones being the
helioscope technique. We report on the current status of the CERN Axion Solar
Telescope and the future International Axion Observatory (IAXO). Recent results
from the second part of CAST phase II, where the magnet bores were filled with
3He gas at variable pressure achieving sensibilities on the axion mass up to
1.2 eV, are presented. Currently, CAST is expecting to improve its sensitivity
to solar axions with rest mass below 0.02 eV/c^2 after the upgrade of the X-ray
detectors and with the implementation of a second X-ray optic. At the same
time, it is exploring other possibilities at the low energy physics frontier.
On the other hand IAXO, the fourth generation axion helioscope, aims to improve
CAST's performance in terms of axion-photon coupling by 1-1.5 orders of
magnitude. The details of the project building a dedicated magnet, optics and
X-ray detectors are given.
[12]
oai:arXiv.org:1501.01466 [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas
x-ray detectors for axion searches
Iguaz, F. J.;
Aune, S.;
Aznar, F.;
Castel, J. F.;
Dafni, T.;
Davenport, M.;
Ferrer-Ribas, E.;
Galan, J.;
Garcia, J. A.;
Garza, J. G.;
Giomataris, I.;
Irastorza, I. G.;
Papaevangelou, T.;
Rodriguez, A.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in
the presence of high magnetic fields. The use of low background x-ray detectors
is an essential component contributing to the sensitivity of these searches. In
this work, we review the recent advances on Micromegas detectors used in the
CERN Axion Solar Telescope (CAST) and proposed for the future International
Axion Observatory (IAXO). The actual setup in CAST has achieved background
levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than
the first generation of Micromegas detectors. This reduction is based on active
and passive shielding techniques, the selection of radiopure materials, offline
discrimination techniques and the high granularity of the readout. We describe
in detail the background model of the detector, based on its operation at CAST
site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4
simulations. The best levels currently achieved at LSC are low than 10$^{-7}$
keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of
this technology in IAXO. Finally, we present some ideas and results for
reducing the energy threshold of these detectors below 1 keV, using
high-transparent windows, autotrigger electronics and studying the cluster
shape at different energies. As a high flux of axion-like-particles is expected
in this energy range, a sub-keV threshold detector could enlarge the physics
case of axion helioscopes.
[13]
oai:arXiv.org:1307.1985 [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark
matter gap
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Brauninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Da Riva, E.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Georgiopoulou, E.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Marzoa, M. Gomez;
Gruber, E.;
Guthorl, T.;
Hartmann, R.;
Hauf, S.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Karuza, M.;
Konigsmann, K.;
Kotthaus, R.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Lang, P. M.;
Laurent, J. M.;
Liolios, A.;
Ljubicic, A.;
Lozza, V.;
Luzon, G.;
Neff, S.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Riege, H.;
Rodriguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Shilon, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomas, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar
axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV.
This closes the gap to the cosmological hot dark matter limit and actually
overlaps with it. From the absence of excess X-rays when the magnet was
pointing to the Sun we set a typical upper limit on the axion-photon coupling
of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on
the pressure setting. Future direct solar axion searches will focus on
increasing the sensitivity to smaller values of g_a, for example by the
currently discussed next generation helioscope IAXO.
[14]
oai:arXiv.org:1305.2360 [pdf] - 776422
In situ measurement of the electron drift velocity for upcoming
directional Dark Matter detectors
Billard, J.;
Mayet, F.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Richer, J. P.;
Riffard, Q.;
Santos, D.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-05-10, last modified: 2014-01-28
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection and it requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence needed as it is a way to avoid bias in the 3D track reconstruction. We
present a dedicated method for the measurement of the electron drift velocity
with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3.
The latter has been chosen for the MIMAC detector as we expect that adding CHF3
to pure CF4 will lower the electron drift velocity. This is a key point for
directional Dark Matter as the track sampling along the drift field will be
improved while keeping almost the same Fluorine content of the gas mixture. We
show that the drift velocity at 50 mbar is reduced by a factor of about 5 when
adding 30% of CHF3.
[15]
oai:arXiv.org:1401.1009 [pdf] - 766735
Measurement of the electron drift velocity for directional dark matter
detectors
Mayet, F.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Richer, J. P.;
Riffard, Q.;
Santos, D.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2014-01-06
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection. It requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence a way to avoid bias in the 3D track reconstruction. We present a
dedicated method for the measurement of the electron drift velocity with the
MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm
CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the
electron drift velocity while keeping almost the same Fluorine content of the
gas mixture.
[16]
oai:arXiv.org:1304.2255 [pdf] - 1165808
MIMAC: A micro-tpc matrix for dark matter directional detection
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, C.;
Guillaudin, O.;
Lamblin, J.;
Muraz, J. F.;
Mayet, F.;
Richer, J. P.;
Riffard, Q.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-04-08
The dark matter directional detection opens a new field in cosmology bringing
the possibility to build a map of nuclear recoils that would be able to explore
the galactic dark matter halo giving access to a particle characterization of
such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers)
collaboration has developed in the last years an original prototype detector
based on the direct coupling of large pixelized micromegas with a devoted fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The discovery potential of this search strategy is
discussed and illustrated. In June 2012, the first bi-chamber prototype has
been installed at Modane Underground Laboratory (LSM) and the first underground
background events, the gain stability and calibration are shown.
[17]
oai:arXiv.org:1210.3287 [pdf] - 1152052
Micromegas-TPC operation at high pressure in xenon-trimethylamine
mixtures
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Gonzalez-Diaz, D.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Rodríguez, A.;
Segui, L.;
Tomás, A.
Submitted: 2012-10-11, last modified: 2012-11-23
In this work we present a systematic study of Micromegas detectors in high
pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains
and energy resolutions for 22.1 keV X-rays are measured for pressures between 1
and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We
observe stable operation at all pressures, and a strongly enhanced gas gain,
suggestive of Penning-like energy-transfer processes. The effect is present at
all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3
%. Operating in this concentration range, the maximum gain reached values as
high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable
for 22.1 keV X-rays is substantially better than the one previously obtained in
pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of
interest for calorimetric applications of high pressure gas Xe TPCs, in
particular for the search of the neutrinoless double beta decay of Xe-136. The
resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value
of Xe-136 for 1 (10) bar.
[18]
oai:arXiv.org:1209.6347 [pdf] - 1453905
Results and perspectives of the solar axion search with the CAST
experiment
Ferrer-Ribas, E.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Ezer, C.;
Fanourakis, G.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gómez, H.;
Gruber, E.;
Guthörl, T.;
Hartmann, R.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovčić, K.;
Karuza, M.;
Königsmann, K.;
Kotthaus, R.;
Krčmar, M.;
Kuster, M.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Lozza, V.;
Lutz, G.;
Luzón, G.;
Morales, J.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Rashba, T.;
Riege, H.;
Rodríguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomás, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2012-09-27, last modified: 2012-10-30
The status of the solar axion search with the CERN Axion Solar Telescope
(CAST) will be presented. Recent results obtained by the use of $^3$He as a
buffer gas has allowed us to extend our sensitivity to higher axion masses than
our previous measurements with $^4$He. With about 1 h of data taking at each of
252 different pressure settings we have scanned the axion mass range 0.39 eV$
\le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the
magnet was pointing to the Sun we set a typical upper limit on the axion-photon
coupling of g$_{a\gamma} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the
exact value depending on the pressure setting. CAST published results represent
the best experimental limit on the photon couplings to axions and other similar
exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the
considered mass range and for the first time the limit enters the region
favored by QCD axion models. Preliminary sensitivities for axion masses up to
1.16 eV will also be shown reaching mean upper limits on the axion-photon
coupling of g$_{a\gamma} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L.
Expected sensibilities for the extension of the CAST program up to 2014 will be
presented. Moreover long term options for a new helioscope experiment will be
evoked.
[19]
oai:arXiv.org:1208.5690 [pdf] - 771411
CAST microbulk micromegas in the Canfranc Underground Laboratory
Tomás, A.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gómez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Papaevangelou, T.;
Rodríguez, A.;
Ruz, J.;
Seguí, L.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2012-08-28
During the last taking data campaigns of the CAST experiment, the micromegas
detectors have achieved background levels of $\approx 5 \times
10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has
been possible thanks to the introduction of the microbulk technology, the
implementation of a shielding and the development of discrimination algorithms.
It has motivated new studies towards a deeper understanding of CAST detectors
background. One of the working lines includes the construction of a replica of
the set-up used in CAST by micromegas detectors and its installation in the
Canfranc Underground Laboratory. Thanks to the comparison between the
performance of the detectors underground and at surface, shielding upgrades,
etc, different contributions to the detectors background have been evaluated.
In particular, an upper limit $< 2 \times 10^{-7}$keV$^{-1}$cm$^{-2}$s$^{-1}$
for the intrinsic background of the detector has been obtained. This work means
a first evaluation of the potential of the newest micromegas technology in an
underground laboratory, the most suitable environment for Rare Event Searches.
[20]
oai:arXiv.org:1201.3012 [pdf] - 1092971
Characterization of microbulk detectors in argon- and neon-based
mixtures
Submitted: 2012-01-14
A recent Micromegas manufacturing technique, so called Microbulk, has been
developed, improving the uniformity and stability of this kind of detectors.
Excellent energy resolutions have been obtained, reaching values as low as 11%
FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its
flexible structure, low material budget and high radio-purity. Two microbulk
detectors with gaps of 50 and 25 um have been characterized in argon- and
neon-based mixtures with ethane, isobutane and cyclohexane. The results will be
presented and discussed. The gain curves have been fitted to the Rose-Korff
gain model and dependences of the electron mean free path and the threshold
energy for ionization have been obtained. The possible relation between these
two parameters and the energy resolution will be also discussed.
[21]
oai:arXiv.org:1111.1566 [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark
matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search
strategy for discriminating WIMP events from background ones. This strategy
requires both a measurement of the recoil energy down to a few keV and 3D
reconstruction of tracks down to a few mm. The MIMAC project, based on a
micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first
results of a chamber prototype of this matrix, on low energy nuclear recoils
(1H and 19F) obtained with mono-energetic neutron fields are presented. The
discovery potential of this search strategy is illustrated by a realistic case
accessible to MIMAC.
[22]
oai:arXiv.org:1110.2608 [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Galan, J.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gomez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Papaevangelou, T.;
Rodriguez, A.;
Ruz, J.;
Segui, L.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination
capabilities, are good candidates for rare event search experiments. Recent
X-ray background levels achieved by these detectors in the CAST experiment have
motivated further studies in the nature of the background levels measured. In
particular, different shielding configurations have been tested at the Canfranc
Underground Laboratory, using a microbulk type detector which was previously
running at the CAST experiment. The first results underground show that this
technology, which is made of low radiative materials, is able to reach
background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a
proper shielding. Moreover, the experimental background measurements are
complemented with Geant4 simulations which allow to understand the origin of
the background, and to optimize future shielding set-ups.
[23]
oai:arXiv.org:1109.1675 [pdf] - 1083919
Micromegas detector developments for MIMAC
Ferrer-Ribas, E.;
Attié, D.;
Calvet, D.;
Colas, P.;
Druillole, F.;
Giomataris, Y.;
Iguaz, F. J.;
Mols, J. P.;
Pancin, J.;
Papaevangelou, T.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
[24]
oai:arXiv.org:1102.3265 [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with CF4 and CHF3. The first results on low energy nuclear recoils (H, F)
obtained with a low mono-energetic neutron field are presented. The discovery
potential of this search strategy is discussed and illustrated by a realistic
case accessible to MIMAC.
[25]
oai:arXiv.org:1012.1166 [pdf] - 955699
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Allaoua, A.;
Golabek, C.;
Lebreton, L.
Submitted: 2010-12-06
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H
and 19F) obtained with a low mono-energetic neutron field are presented. The
discovery potential of this search strategy is discussed and illustrated by a
realistic case accessible to MIMAC.
[26]
oai:arXiv.org:1009.1827 [pdf] - 261761
Micromegas readouts for double beta decay searches
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Giomataris, I.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Rodríguez, A.;
Seguí, L.;
Tomás, A.
Submitted: 2010-09-09
Double beta $\beta\beta$ decay experiments are one of the most active
research topics in Neutrino Physics. The measurement of the neutrinoless mode
$0\nu\beta\beta$ could give unique information on the neutrino mass scale and
nature. The current generation of experiments aims at detector target masses at
the 100 kg scale, while the next generation will need to go to the ton scale in
order to completely explore the inverse hierarchy models of neutrino mass. Very
good energy resolutions and ultra-low background levels are the two main
experimental requirements for a successful experiment. The topological
information of the $\beta\beta$ events offered by gaseous detectors like gas
Time Projection Chambers (TPC) could provide a very powerful tool of signal
identification and background rejection. However only recent advances in TPC
readouts may assure the competitiveness of a high pressure gas TPCs for
$\beta\beta$ searches, especially regarding the required energy resolution. In
this paper we present first results on energy resolution with state-of-the-art
microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV
alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have
been achieved for pressures up to 5 bar. These results, together with their
recently measured radiopurity , prove that Micromegas readouts are not only a
viable option but a very competitive one for $\beta\beta$ searches.
[27]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.