Normalized to: Ida, C.
[1]
oai:arXiv.org:1002.1794 [pdf] - 1025066
First underground results with NEWAGE-0.3a direction-sensitive dark
matter detector
Miuchi, Kentaro;
Nishimura, Hironobu;
Hattori, Kaori;
Higashi, Naoki;
Ida, Chihiro;
Iwaki, Satoshi;
Kabuki, Shigeto;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Nakamura, Kiseki;
Parker, Joseph;
Sawano, Tatsuya;
Takahashi, Michiaki;
Tanimori, Toru;
Taniue, Kojiro;
Ueno, Kazuki;
Sekiya, Hiroyuki;
Takeda, Atsushi;
Tsuchiya, Ken'ichi;
Takada, Atsushi
Submitted: 2010-02-09
A direction-sensitive dark matter search experiment at Kamioka underground
laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a
detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152
Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg,
respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly
interacting massive particle (WIMP)-proton cross section limits by a
direction-sensitive method were achieved including a new record of 5400 pb for
150 GeV/c2 WIMPs. We studied the remaining background and found that ambient
gamma-rays contributed about one-fifth of the remaining background and
radioactive contaminants inside the gas chamber contributed the rest.
[2]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.