Normalized to: Ichimura, K.
[1]
oai:arXiv.org:2006.09664 [pdf] - 2117112
Improved method for measuring low concentration radium and its
application to the Super-Kamiokande Gadolinium project
Ito, S.;
Ichimura, K.;
Takaku, Y.;
Abe, K.;
Harada, M.;
Ikeda, M.;
Ito, H.;
Kishimoto, Y.;
Nakajima, Y.;
Okada, T.;
Sekiya, H.
Submitted: 2020-06-17
Chemical extraction using a molecular recognition resin named "Empore Radium
Rad Disk" was developed to improve sensitivity for the low concentration of
radium (Ra). Compared with the previous method, the extraction process speed
was improved by a factor of three and the recovery rate for $^{226}$Ra was also
improved from 81$\pm$4% to $>$99.9%. The sensitivity on the 10$^{-1}$ mBq level
was achieved using a high purity germanium detector. This improved method was
applied to determine $^{226}$Ra in Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O which will
be used in the Super-Kamiokande Gadolinium project. The improvement and
measurement results are reported in this paper.
[2]
oai:arXiv.org:2005.11891 [pdf] - 2112667
Search for exotic neutrino-electron interactions using solar neutrinos
in XMASS-I
XMASS collaboration;
Abe, K.;
Chen, Y.;
Hiraide, K.;
Ichimura, K.;
Imaizumi, S.;
Kato, N.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Kim, Y. H.;
Ishii, R.;
Itow, Y.;
Kanzawa, K.;
Martens, K.;
Mason, A.;
Suzuki, Y.;
Miuchi, K.;
Takeuchi, Y.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Ogawa, H.;
Kishimoto, Y.;
Nishijima, K.;
Fushimi, K.;
Xu, B. D.;
Nakamura, S.
Submitted: 2020-05-24
We have searched for exotic neutrino-electron interactions that could be
produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark
photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed
no significant signals in 711 days of data. We obtain an upper limit for
neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level
assuming all three species of neutrino have common millicharge. We also set
flavor dependent limits assuming the respective neutrino flavor is the only one
carrying a millicharge, $7.3 \times 10^{-12} e$ for $\nu_e$, $1.1 \times
10^{-11} e$ for $\nu_{\mu}$, and $1.1 \times 10^{-11} e$ for $\nu_{\tau}$.
These limits are the most stringent yet obtained from direct measurements. We
also obtain an upper limit for the neutrino magnetic moment of
1.8$\times$10$^{-10}$ Bohr magnetons. In addition, we obtain upper limits for
the coupling constant of dark photons in the $U(1)_{B-L}$ model of
1.3$\times$10$^{-6}$ if the dark photon mass is 1$\times 10^{-3}$ MeV$/c^{2}$,
and 8.8$\times$10$^{-5}$ if it is 10 MeV$/c^{2}$.
[3]
oai:arXiv.org:1912.09683 [pdf] - 2026579
Anisotropic Response Measurements of ZnWO$_4$ Scintillators to Neutrons
for Developing the Direction-Sensitive Dark Matter Detector
Submitted: 2019-12-20, last modified: 2020-01-07
The scintillation yields of ZnWO$_4$ crystals change depending on the
incident direction of particles. This property can be used as a
direction-sensitive dark matter detector. So, we investigated the ZnWO$_4$
light yields ratio of neutron-induced nuclear recoils to gamma-ray induced
electron recoils(quenching factor). Two surfaces almost perpendicular to the
crystal axis of ZnWO$_4$ were irradiated with a quasi-monochromatic neutron
beam of 0.885MeV, and the quenching factors of both surfaces for the
oxygen-nucleus recoil in the ZnWO$_4$ crystal were measured. The obtained
quenching factors of the two surfaces were 0.235 $\pm$ 0.026 and 0.199 $\pm$
0.020, respectively confirming 15.3$\%$ of anisotropy.
[4]
oai:arXiv.org:1809.05358 [pdf] - 1851548
Search for WIMP-$^{129}$Xe inelastic scattering with particle
identification in XMASS-I
XMASS Collaboration;
Suzuki, T.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-09-14, last modified: 2019-03-19
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with
the single-phase liquid-xenon detector XMASS through inelastic scattering in
which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times
800.0 \; days$) 48 times larger than that of our previous study. The inelastic
excitation sensitivity was improved by detailed evaluation of background, event
classification based on scintillation timing that distinguished $\gamma$-rays
and $\beta$-rays, and simultaneous fitting of the energy spectra of
$\gamma$-like and $\beta$-like samples. No evidence of a WIMP signal was found.
Thus, we set the upper limits of the inelastic channel cross section at 90\%
confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\;
{\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD
WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm
GeV}/c^2$ than the existing experimental limit.
[5]
oai:arXiv.org:1808.03617 [pdf] - 1822844
Development of low radioactivity photomultiplier tubes for the XMASS-I
detector
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-08-10, last modified: 2019-01-29
XMASS-I is a single-phase liquid xenon detector whose purpose is direct
detection of dark matter. To achieve the low background requirements necessary
in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a
hexagonal window was developed based on the R8778 PMT used in the XMASS
prototype detector. We screened the numerous component materials for their
radioactivity. During development, the largest contributions to the reduction
of radioactivity came from the stem and the dynode support. The glass stem was
exchanged to the Kovar alloy one and the ceramic support were changed to the
quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted
these materials for low background purposes and provided a groundbreaking step
for further reductions of radioactivity in PMTs. Measurements with germanium
detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of
$^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of
$^{60}$Co. In this paper, the radioactive details of the developed R10789 are
described together with our screening methods and the components of the PMT.
[6]
oai:arXiv.org:1804.02180 [pdf] - 1806000
A direct dark matter search in XMASS-I
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-04-06, last modified: 2018-12-25
A search for dark matter using an underground single-phase liquid xenon
detector was conducted at the Kamioka Observatory in Japan, particularly for
Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of
data in a fiducial volume containing 97 kg of liquid xenon at the center of the
detector. The event rate in the fiducial volume after the data reduction was
${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm
5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining
events are consistent with our background evaluation, mostly of the
"mis-reconstructed events" originated from $^{210}$Pb in the copper plates
lining the detector's inner surface. The obtained upper limit on a
spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \,
cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence
level, which was the most stringent limit among results from single-phase
liquid xenon detectors.
[7]
oai:arXiv.org:1808.06177 [pdf] - 1901740
Search for sub-GeV dark matter by annual modulation using XMASS-I
detector
Kobayashi, M.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-08-19, last modified: 2018-12-22
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV)
was conducted by looking for an annual modulation signal in XMASS, a
single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by
bremsstrahlung emission was used to search down to an electron equivalent
energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in
calendar time), resulting in a total exposure of 2.38 ton-years. No significant
modulation signal was observed and 90% confidence level upper limits of $1.6
\times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section.
This is the first experimental result of a search for DM mediated by the
bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV
region (4-20 GeV) was conducted with a lower energy threshold than previous
analysis of XMASS. Elastic nuclear scattering was used to search down to a
nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9
$\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
[8]
oai:arXiv.org:1807.08516 [pdf] - 1786927
Search for dark matter in the form of hidden photons and axion-like
particles in the XMASS detector
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-07-23, last modified: 2018-11-18
Hidden photons and axion-like particles are candidates for cold dark matter
if they were produced non-thermally in the early universe. We conducted a
search for both of these bosons using 800 live-days of data from the XMASS
detector with 327 kg of liquid xenon in the fiducial volume. No significant
signal was observed, and thus we set constraints on the $\alpha' / \alpha$
parameter related to kinetic mixing of hidden photons and the coupling constant
$g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$,
resulting in $\alpha' / \alpha < 6 \times 10^{-26}$ and $g_{Ae} < 4 \times
10^{-13}$. These limits are the most stringent derived from both direct and
indirect searches to date.
[9]
oai:arXiv.org:1801.10096 [pdf] - 1690355
Direct dark matter search by annual modulation with 2.7 years of XMASS-I
data
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-01-30, last modified: 2018-05-25
An annual modulation signal due to the Earth orbiting around the Sun would be
one of the strongest indications of the direct detection of dark matter. In
2016, we reported a search for dark matter by looking for this annual
modulation with our single-phase liquid xenon XMASS-I detector. That analysis
resulted in a slightly negative modulation amplitude at low energy. In this
work, we included more than one year of additional data, which more than
doubles the exposure to 800 live days with the same 832 kg target mass. When we
assume weakly interacting massive particle (WIMP) dark matter elastically
scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon
cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8
GeV/c$^2$ at 90\% confidence level with our newly implemented data selection
through a likelihood method. For the model-independent case, without assuming
any specific dark matter model, we obtained more consistency with the null
hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy
region. This search probed this region with an exposure that was larger than
that of DAMA/LIBRA. We also did not find any significant amplitude in the data
for periodicity with periods between 50 and 600 days in the energy region
between 1 to 6 keV.
[10]
oai:arXiv.org:1707.08995 [pdf] - 1586478
Search for solar Kaluza-Klein axion by annual modulation with the
XMASS-I detector
XMASS Collaboration;
Oka, N.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2017-07-19, last modified: 2017-11-15
In theories with the large extra dimensions beyond the standard 4-dimensional
spacetime, axions could propagate in such extra dimensions, and acquire
Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and
could solve unexplained heating of the solar corona. While most of the solar KK
axions escape from the solar system, a small fraction is gravitationally
trapped in orbits around the Sun. They would decay into two photons inside a
terrestrial detector. The event rate is expected to modulate annually depending
on the distance from the Sun. We have searched for the annual modulation
signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant
event rate modulation is found, and hence we set the first experimental
constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\,
\mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of
$\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number
of extra dimensions $n = 2$, and the number of extra dimensions $\delta = 2$
that axions can propagate in.
[11]
oai:arXiv.org:1604.01503 [pdf] - 1458949
A measurement of the time profile of scintillation induced by low energy
gamma-rays in liquid xenon with the XMASS-I detector
XMASS Collaboration;
Takiya, H.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kegasa, R.;
Kobayashi, K.;
Masuda, K.;
Fushimi, K.;
Martens, K.;
Suzuki, Y.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Onishi, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, J. S.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Nishijima, K.;
Nakamura, S.
Submitted: 2016-04-06, last modified: 2016-08-18
We report the measurement of the emission time profile of scintillation from
gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation
detector. Decay time constant was derived from a comparison of scintillation
photon timing distributions between the observed data and simulated samples in
order to take into account optical processes such as absorption and scattering
in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe,
$^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming
two decay components, $\tau_1$ and $\tau_2$, the decay time constant $\tau_2$
increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9
keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all
energy levels. A fast decay component with $\tau_1 \sim 2$ ns was necessary to
reproduce data. Energy dependencies of $\tau_2$ and the fraction of the fast
decay component were studied as a function of the kinetic energy of electrons
induced by gamma-rays. The obtained data almost reproduced previously reported
results and extended them to the lower energy region relevant to direct dark
matter searches.
[12]
oai:arXiv.org:1511.04807 [pdf] - 1413079
Direct dark matter search by annual modulation in XMASS-I
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Tasaka, S.;
Fushimi, K.;
Liu, J.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Onishi, Y.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, J. S.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Itow, Y.;
Kegasa, R.;
Kobayashi, K.;
Masada, K.;
Takiya, H.;
Nishijima, K.;
Nakamura, S.
Submitted: 2015-11-15, last modified: 2016-05-25
A search for dark matter was conducted by looking for an annual modulation
signal due to the Earth's rotation around the Sun using XMASS, a single phase
liquid xenon detector. The data used for this analysis was 359.2 live days
times 832 kg of exposure accumulated between November 2013 and March 2015. When
we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically
scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon
cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we
exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range
at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without
assuming any specific dark matter model but including electron/$\gamma$ events,
showed a slight negative amplitude. The $p$-values obtained with two
independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we
obtained 90\% C.L. upper bounds that can be used to test various models. This
is the first extensive annual modulation search probing this region with an
exposure comparable to DAMA/LIBRA.
[13]
oai:arXiv.org:1405.6190 [pdf] - 1323331
7Be Solar Neutrino Measurement with KamLAND
Gando, A.;
Gando, Y.;
Hanakago, H.;
Ikeda, H.;
Inoue, K.;
Ishidoshiro, K.;
Ishikawa, H.;
Kishimoto, Y.;
Koga, M.;
Matsuda, R.;
Matsuda, S.;
Mitsui, T.;
Motoki, D.;
Nakajima, K.;
Nakamura, K.;
Obata, A.;
Oki, A.;
Oki, Y.;
Otani, M.;
Shimizu, I.;
Shirai, J.;
Suzuki, A.;
Tamae, K.;
Ueshima, K.;
Watanabe, H.;
Xu, B. D.;
Yamada, S.;
Yamauchi, Y.;
Yoshida, H.;
Kozlov, A.;
Takemoto, Y.;
Yoshida, S.;
Grant, C.;
Keefer, G.;
McKee, D. W.;
Piepke, A.;
Banks, T. I.;
Bloxham, T.;
Freedman, S. J.;
Fujikawa, B. K.;
Han, K.;
Hsu, L.;
Ichimura, K.;
Murayama, H.;
O'Donnell, T.;
Steiner, H. M.;
Winslow, L. A.;
Dwyer, D.;
Mauger, C.;
McKeown, R. D.;
Zhang, C.;
Berger, B. E.;
Lane, C. E.;
Maricic, J.;
Miletic, T.;
Learned, J. G.;
Sakai, M.;
Horton-Smith, G. A.;
Tang, A.;
Downum, K. E.;
Tolich, K.;
Efremenko, Y.;
Kamyshkov, Y.;
Perevozchikov, O.;
Karwowski, H. J.;
Markoff, D. M.;
Tornow, W.;
Detwiler, J. A.;
Enomoto, S.;
Heeger, K.;
Decowski, M. P.
Submitted: 2014-05-23, last modified: 2015-09-30
We report a measurement of the neutrino-electron elastic scattering rate of
862 keV 7Be solar neutrinos based on a 165.4 kton-day exposure of KamLAND. The
observed rate is 582 +/- 90 (kton-day)^-1, which corresponds to a 862 keV 7Be
solar neutrino flux of (3.26 +/- 0.50) x 10^9 cm^-2s^-1, assuming a pure
electron flavor flux. Comparing this flux with the standard solar model
prediction and further assuming three flavor mixing, a nu_e survival
probability of 0.66 +/- 0.14 is determined from the KamLAND data. Utilizing a
global three flavor oscillation analysis, we obtain a total 7Be solar neutrino
flux of (5.82 +/- 0.98) x 10^9 cm^-2s^-1, which is consistent with the standard
solar model predictions.
[14]
oai:arXiv.org:1406.0502 [pdf] - 869600
Search for bosonic superweakly interacting massive dark matter particles
with the XMASS-I detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Ichimura, K.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-06-02, last modified: 2014-08-21
Bosonic superweakly interacting massive particles (super-WIMPs) are a
candidate for warm dark matter. With the absorption of such a boson by a xenon
atom these dark matter candidates would deposit an energy equivalent to their
rest mass in the detector. This is the first direct detection experiment
exploring the vector super-WIMPs in the mass range between 40 and 120 keV.
Using 165.9 days of data no significant excess above background was observed in
the fiducial mass of 41 kg. The present limit for the vector super-WIMPs
excludes the possibility that such particles constitute all of dark matter. The
absence of a signal also provides the most stringent direct constraint on the
coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented
sensitivity was achieved exploiting the low background at a level $10^{-4}$
kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
[15]
oai:arXiv.org:1401.4737 [pdf] - 1425198
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from
the XMASS-I experiment
Uchida, H.;
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-01-19, last modified: 2014-04-29
A search for inelastic scattering of Weakly Interacting Massive Particles
(WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase
liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted
volume containing 41 kg of LXe at the very center of our detector we observed
no significant excess of events in 165.9 days of data. Our background reduction
allowed us to derive our limits without explicitly subtracting the remaining
events which are compatible with background expectations and derive for e.g. a
50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei
of 3.2 pb at the 90% confidence level.
[16]
oai:arXiv.org:1106.0861 [pdf] - 669553
Measurement of the 8B Solar Neutrino Flux with the KamLAND Liquid
Scintillator Detector
KamLAND Collaboration;
Abe, S.;
Furuno, K.;
Gando, A.;
Gando, Y.;
Ichimura, K.;
Ikeda, H.;
Inoue, K.;
Kibe, Y.;
Kimura, W.;
Kishimoto, Y.;
Koga, M.;
Minekawa, Y.;
Mitsui, T.;
Morikawa, T.;
Nagai, N.;
Nakajima, K.;
Nakamura, K.;
Nakamura, M.;
Narita, K.;
Shimizu, I.;
Shimizu, Y.;
Shirai, J.;
Suekane, F.;
Suzuki, A.;
Takahashi, H.;
Takahashi, N.;
Takemoto, Y.;
Tamae, K.;
Watanabe, H.;
Xu, B. D.;
Yabumoto, H.;
Yonezawa, E.;
Yoshida, H.;
Yoshida, S.;
Enomoto, S.;
Kozlov, A.;
Murayama, H.;
Grant, C.;
Keefer, G.;
McKee, D.;
Piepke, A.;
Banks, T. I.;
Bloxham, T.;
Detwiler, J. A.;
Freedman, S. J.;
Fujikawa, B. K.;
Han, K.;
Kadel, R.;
O'Donnell, T.;
Steiner, H. M.;
Winslow, L. A.;
Dwyer, D. A.;
Mauger, C.;
McKeown, R. D.;
Zhang, C.;
Berger, B. E.;
Lane, C. E.;
Maricic, J.;
Miletic, T.;
Batygov, M.;
Learned, J. G.;
Matsuno, S.;
Pakvasa, S.;
Sakai, M.;
Horton-Smith, G. A.;
Tang, A.;
Downum, K. E.;
Gratta, G.;
Tolich, K.;
Efremenko, Y.;
Kamyshkov, Y.;
Perevozchikov, O.;
Karwowski, H. J.;
Markoff, D. M.;
Tornow, W.;
Heeger, K. M.;
Piquemal, F.;
Ricol, J. -S.;
Decowski, M. P.
Submitted: 2011-06-04, last modified: 2011-08-25
We report a measurement of the neutrino-electron elastic scattering rate from
8B solar neutrinos based on a 123 kton-day exposure of KamLAND. The
background-subtracted electron recoil rate, above a 5.5 MeV analysis threshold
is 1.49+/-0.14(stat)+/-0.17(syst) events per kton-day. Interpreted as due to a
pure electron flavor flux with a 8B neutrino spectrum, this corresponds to a
spectrum integrated flux of 2.77+/-0.26(stat)+/-0.32(syst) x 10^6 cm^-2s^-1.
The analysis threshold is driven by 208Tl present in the liquid scintillator,
and the main source of systematic uncertainty is due to background from
cosmogenic 11Be. The measured rate is consistent with existing measurements and
with Standard Solar Model predictions which include matter enhanced neutrino
oscillation.