sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Icdem, Burcin

Normalized to: Icdem, B.

4 article(s) in total. 3 co-authors, from 1 to 4 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1105.1630  [pdf] - 422097
\emph{RXTE} Timing Analysis of the AXP 1E 2259+586
Comments: 13 pages, 1 figure, accepted to be published in MNRAS
Submitted: 2011-05-09, last modified: 2011-10-05
We report the pulse timing analysis of \emph{Rossi X-ray Timing Explorer} (\emph{RXTE}) observations of the anomalous X-ray pulsar 1E 2259+586 from its 2002 outburst to October, 2010. Our objectives are to extend the work on the recovery stage after the 2002 glitch, investigate the variations caused by the second glitch which occurred in 2007 and look for other unusual events, if any, that arise in the regular spin-down trend of the source. The recovery of the 2002 glitch gives good fit when the two-exponential glitch model of the Crab pulsar is used, rather than the standard glitch model, in the 1360-day interval after the first glitch. The sampling of the following 260-day is not frequent enough to be phase-connected. After that interval, our timing analysis yields that there is a fractional frequency change of $\frac{\Delta\nu}{\nu}\sim8.20(2)\times10^{-7}$. Moreover, we report two frequency shifts of fractional changes, $\frac{\Delta\nu}{\nu}\sim3\times10^{-8},-1\times10^{-8}$: The first one at MJD $\sim53750$ had a positive fractional frequency change in contrast to the second one at MJD $\sim54880$ for which the pulse frequency decreased. These frequency shifts both resemble the microglitches observed in radio pulsars.
[2]  oai:arXiv.org:1104.4437  [pdf] - 348186
Re-analysis of Timing Parameters of OAO 1657-415
Comments: 5 pages, 1 figure, Conference proceeding of Fast X-ray timing and spectroscopy at extreme count rates: Science with the HTRS on the International X-ray Observatory - HTRS2011, February 7-11, 2011, Champ\'ery, Switzerland
Submitted: 2011-04-22
In this paper, we present the re-analysis of a set of RXTE-PCA observations of OAO 1657-415 during 1997 August 20-27. We found a revised timing solution which was found to fit better to the data and updated pulse frequency values accordingly. We also verified that there is a marginal correlation between the gradual spin-up (or decrease in spin-down rate) and increase in X-ray luminosity as suggested by Baykal (2000).
[3]  oai:arXiv.org:1101.5168  [pdf] - 1051720
Timing and X-ray Spectral Features of Swift J1626.6-5156
Comments: Revised version; 12 pages, 4 figures, accepted for publication in MNRAS
Submitted: 2011-01-26, last modified: 2011-04-22
In this paper, we extend timing analysis of Baykal et al. (2010) of \src using RXTE-PCA observations between MJD 53724 and MJD 55113 together with a Chandra-ACIS observation on MJD 54897 with a 20 ks exposure. We also present X-ray spectral analysis of these RXTE and Chandra observations. We find that the spin-up rate of the source is correlated with the X-ray flux. Using this correlation, we estimate the distance and surface magnetic field of the source as $\sim 15$kpc and $\sim 9\times 10^{11}$Gauss respectively. From the spectral analysis, we found that power law index increases and Hydrogen column density decreases with decreasing flux.
[4]  oai:arXiv.org:1104.4432  [pdf] - 1053522
Pulse Profiles of Swift J1626.6+5156
Comments: 4 pages, 2 figures, Conference proceeding of "Astrophysics of Neutron Stars 2010 -- a conference in honor of M. Ali Alpar", 2-6 August 2010, Cesme, Izmir, Turkey
Submitted: 2011-04-22
In this paper, we analyzed pulse profiles of Swift J1626.6+5156 using the lightcurves from RXTE-PCA observations between MJD 53724 (just after the outburst) and MJD 55113 and a Chandra-ACIS dataset on MJD 54897 with a 20 ks exposure. We found that pulse profiles show morphological variations and pulsations do not cease even $\sim 1200$ days after the outburst. Despite these variations, we did not find any significant variation in the pulsed fraction with decreasing X-ray flux.