Normalized to: Huovelin, J.
[1]
oai:arXiv.org:1807.06092 [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Cappi, Massimo;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rozanska, Agata;
Wilms, Joern;
Bandler, Simon;
Barbera, Marco;
Barcons, Xavier;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Costantini, Elisa;
Decourchelle, Anne;
Hartog, Roland den;
Duband, Lionel;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Sato, Kosuke;
Schaye, Joop;
Shinozaki, Keisuke;
Thibert, Tanguy;
Valenziano, Luca;
Valette, Veronique;
Vink, Jacco;
Webb, Natalie;
Wise, Michael;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Mesnager, Jean-Michel;
Pontet, Bernard;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Bulbul, Esra;
Dadina, Mauro;
Ettori, Stefano;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Kaastra, Jelle;
Mazzotta, Pasquale;
Miller, Jon;
Miniutti, Giovanni;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Simionescu, Aurora;
Torrejon, Jose Miguel;
Frezouls, Benoît;
Geoffray, Hervé;
Peille, Philippe;
Aicardi, Corinne;
André, Jérôme;
Clénet, Antoine;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hervet, Gilles;
Jolly, Antoine;
Ledot, Aurélien;
Maussang, Irwin;
Paillet, Alexis;
Schmisser, Roseline;
Vella, Bruno;
Damery, Jean-Charles;
Boyce, Kevin;
DiPirro, Michael;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Clerc, Nicolas;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Kirsch, Christian;
Cucchetti, Edoardo;
Eckart, Megan;
Ferrando, Philippe;
Natalucci, Lorenzo
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray
spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5'
equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a
spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is
based on a large format array of super-conducting molybdenum-gold Transition
Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold
and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector
located underneath the prime TES array enables the non X-ray background to be
reduced. A bath temperature of about 50 mK is obtained by a series of
mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers
which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with
an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing
enables to read out 40 pixels in one single channel. A photon interacting with
an absorber leads to a current pulse, amplified by the readout electronics and
whose shape is reconstructed on board to recover its energy with high accuracy.
The defocusing capability offered by the Athena movable mirror assembly enables
the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like
intensities) by spreading the telescope point spread function over hundreds of
pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and
typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10
or more better than Silicon based X-ray detectors. In this paper, the current
X-IFU baseline is presented, together with an assessment of its anticipated
performance in terms of spectral resolution, background, and count rate
capability. The X-IFU baseline configuration will be subject to a preliminary
requirement review that is scheduled at the end of 2018.
[2]
oai:arXiv.org:1608.08105 [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Barcons, Xavier;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rożanska, Agata;
Wilms, Joern;
Barbera, Marco;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Decourchelle, Anne;
Hartog, Roland den;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Renotte, Etienne;
Schaye, Joop;
Shinozaki, Keisuke;
Valenziano, Luca;
Vink, Jacco;
Webb, Natalie;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Du, Michel Le;
Mesnager, Jean-Michel;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Dadina, Mauro;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Miller, Jon;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Torrejon, Jose Miguel;
Geoffray, Hervé;
Hernandez, Isabelle;
Luno, Laure;
Peille, Philippe;
André, Jérôme;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hassin, Jérémie;
Hervet, Gilles;
Maussang, Irwin;
Moueza, Jérôme;
Paillet, Alexis;
Vella, Bruno;
Garrido, Gonzalo Campos;
Damery, Jean-Charles;
Panem, Chantal;
Panh, Johan;
Bandler, Simon;
Biffi, Jean-Marc;
Boyce, Kevin;
Clénet, Antoine;
DiPirro, Michael;
Jamotton, Pierre;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Brand, Thorsten;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Cucchetti, Edoardo
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for
High-ENergy Astrophysics (Athena) will provide spatially resolved
high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels
over a field of view of 5 arc minute equivalent diameter and a spectral
resolution of 2.5 eV up to 7 keV. In this paper, we first review the core
scientific objectives of Athena, driving the main performance parameters of the
X-IFU, namely the spectral resolution, the field of view, the effective area,
the count rate capabilities, the instrumental background. We also illustrate
the breakthrough potential of the X-IFU for some observatory science goals.
Then we briefly describe the X-IFU design as defined at the time of the mission
consolidation review concluded in May 2016, and report on its predicted
performance. Finally, we discuss some options to improve the instrument
performance while not increasing its complexity and resource demands (e.g.
count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The
Netherlands and Italy, with further ESA member state contributions from
Belgium, Finland, Germany, Poland, Spain, Switzerland and two international
partners from the United States and Japan.
[4]
oai:arXiv.org:1501.03930 [pdf] - 1224056
A Multi-wavelength study of the M dwarf binary YY Geminorum
Butler, C. J.;
Erkan, N.;
Budding, E.;
Doyle, J. G.;
Foing, B.;
Bromage, G. E.;
Kellett, B. J.;
Frueh, M.;
Huovelin, J.;
Brown, A.;
Neff, J. E.
Submitted: 2015-01-16
We review the results of the 1988 multi-wavelength campaign on the late-type
eclipsing binary YY Geminorum. Observations include: broad-band optical and
near infra-red photometry, simultaneous optical and ultraviolet (IUE)
spectroscopy, X-ray (Ginga) and radio (VLA) data. From models fitted to the
optical light curves, fundamental physical parameters have been determined
together with evidence for transient maculations (spots) located near
quadrature longitudes and intermediate latitudes.
Eclipses were observed at optical, ultraviolet and radio wavelengths.
Significant drops in 6cm radio emission near the phases of both primary and
secondary eclipse indicate relatively compact radio emitting volumes that may
lie between the binary components. IUE observations during secondary eclipse
are indicative of a uniform chromosphere saturated with MgII plage-type
emission and an extended volume of Ly$\alpha$ emission.
Profile fitting of high-dispersion H alpha spectra confirms the chromospheric
saturation and indicates significant H$\alpha$ opacity to heights of a few
percent of the photospheric radius. There is evidence for an enhanced H alpha
emission region visible near phase 0.25-0.35 which may be associated with a
large spot on the primary and with two small optical flares which were also
observed at other wavelengths: one in microwave radiation and the other in
X-rays. For both flares, L_X/L_opt is consistent with energy release in closed
magnetic structures.
[5]
oai:arXiv.org:1408.6526 [pdf] - 864022
The Large Observatory For x-ray Timing
Feroci, M.;
Herder, J. W. den;
Bozzo, E.;
Barret, D.;
Brandt, S.;
Hernanz, M.;
van der Klis, M.;
Pohl, M.;
Santangelo, A.;
Stella, L.;
Watts, A.;
Wilms, J.;
Zane, S.;
Ahangarianabhari, M.;
Albertus, C.;
Alford, M.;
Alpar, A.;
Altamirano, D.;
Alvarez, L.;
Amati, L.;
Amoros, C.;
Andersson, N.;
Antonelli, A.;
Argan, A.;
Artigue, R.;
Artigues, B.;
Atteia, J. -L.;
Azzarello, P.;
Bakala, P.;
Baldazzi, G.;
Balman, S.;
Barbera, M.;
van Baren, C.;
Bhattacharyya, S.;
Baykal, A.;
Belloni, T.;
Bernardini, F.;
Bertuccio, G.;
Bianchi, S.;
Bianchini, A.;
Binko, P.;
Blay, P.;
Bocchino, F.;
Bodin, P.;
Bombaci, I.;
Bidaud, J. -M. Bonnet;
Boutloukos, S.;
Bradley, L.;
Braga, J.;
Brown, E.;
Bucciantini, N.;
Burderi, L.;
Burgay, M.;
Bursa, M.;
Budtz-Jørgensen, C.;
Cackett, E.;
Cadoux, F. R.;
Cais, P.;
Caliandro, G. A.;
Campana, R.;
Campana, S.;
Capitanio, F.;
Casares, J.;
Casella, P.;
Castro-Tirado, A. J.;
Cavazzuti, E.;
Cerda-Duran, P.;
Chakrabarty, D.;
Château, F.;
Chenevez, J.;
Coker, J.;
Cole, R.;
Collura, A.;
Cornelisse, R.;
Courvoisier, T.;
Cros, A.;
Cumming, A.;
Cusumano, G.;
D'Aì, A.;
D'Elia, V.;
Del Monte, E.;
De Luca, A.;
De Martino, D.;
Dercksen, J. P. C.;
De Pasquale, M.;
De Rosa, A.;
Del Santo, M.;
Di Cosimo, S.;
Diebold, S.;
Di Salvo, T.;
Donnarumma, I.;
Drago, A.;
Durant, M.;
Emmanoulopoulos, D.;
Erkut, M. H.;
Esposito, P.;
Evangelista, Y.;
Fabian, A.;
Falanga, M.;
Favre, Y.;
Feldman, C.;
Ferrari, V.;
Ferrigno, C.;
Finger, M.;
Finger, M. H.;
Fraser, G. W.;
Frericks, M.;
Fuschino, F.;
Gabler, M.;
Galloway, D. K.;
Sanchez, J. L. Galvez;
Garcia-Berro, E.;
Gendre, B.;
Gezari, S.;
Giles, A. B.;
Gilfanov, M.;
Giommi, P.;
Giovannini, G.;
Giroletti, M.;
Gogus, E.;
Goldwurm, A.;
Goluchová, K.;
Götz, D.;
Gouiffes, C.;
Grassi, M.;
Groot, P.;
Gschwender, M.;
Gualtieri, L.;
Guidorzi, C.;
Guy, L.;
Haas, D.;
Haensel, P.;
Hailey, M.;
Hansen, F.;
Hartmann, D. H.;
Haswell, C. A.;
Hebeler, K.;
Heger, A.;
Hermsen, W.;
Homan, J.;
Hornstrup, A.;
Hudec, R.;
Huovelin, J.;
Ingram, A.;
Zand, J. J. M. in't;
Israel, G.;
Iwasawa, K.;
Izzo, L.;
Jacobs, H. M.;
Jetter, F.;
Johannsen, T.;
Jacobs, H. M.;
Jonker, P.;
Josè, J.;
Kaaret, P.;
Kanbach, G.;
Karas, V.;
Karelin, D.;
Kataria, D.;
Keek, L.;
Kennedy, T.;
Klochkov, D.;
Kluzniak, W.;
Kokkotas, K.;
Korpela, S.;
Kouveliotou, C.;
Kreykenbohm, I.;
Kuiper, L. M.;
Kuvvetli, I.;
Labanti, C.;
Lai, D.;
Lamb, F. K.;
Laubert, P. P.;
Lebrun, F.;
Lin, D.;
Linder, D.;
Lodato, G.;
Longo, F.;
Lund, N.;
Maccarone, T. J.;
Macera, D.;
Maestre, S.;
Mahmoodifar, S.;
Maier, D.;
Malcovati, P.;
Mandel, I.;
Mangano, V.;
Manousakis, A.;
Marisaldi, M.;
Markowitz, A.;
Martindale, A.;
Matt, G.;
McHardy, I. M.;
Melatos, A.;
Mendez, M.;
Mereghetti, S.;
Michalska, M.;
Migliari, S.;
Mignani, R.;
Miller, M. C.;
Miller, J. M.;
Mineo, T.;
Miniutti, G.;
Morsink, S.;
Motch, C.;
Motta, S.;
Mouchet, M.;
Mouret, G.;
Mulačová, J.;
Muleri, F.;
Muñoz-Darias, T.;
Negueruela, I.;
Neilsen, J.;
Norton, A. J.;
Nowak, M.;
O'Brien, P.;
Olsen, P. E. H.;
Orienti, M.;
Orio, M.;
Orlandini, M.;
Orleanski, P.;
Osborne, J. P.;
Osten, R.;
Ozel, F.;
Pacciani, L.;
Paolillo, M.;
Papitto, A.;
Paredes, J. M.;
Patruno, A.;
Paul, B.;
Perinati, E.;
Pellizzoni, A.;
Penacchioni, A. V.;
Perez, M. A.;
Petracek, V.;
Pittori, C.;
Pons, J.;
Portell, J.;
Possenti, A.;
Poutanen, J.;
Prakash, M.;
Provost, P. Le;
Psaltis, D.;
Rambaud, D.;
Ramon, P.;
Ramsay, G.;
Rapisarda, M.;
Rachevski, A.;
Rashevskaya, I.;
Ray, P. S.;
Rea, N.;
Reddy, S.;
Reig, P.;
Aranda, M. Reina;
Remillard, R.;
Reynolds, C.;
Rezzolla, L.;
Ribo, M.;
de la Rie, R.;
Riggio, A.;
Rios, A.;
Gil, P. Rodríguez-;
Rodriguez, J.;
Rohlfs, R.;
Romano, P.;
Rossi, E. M. R.;
Rozanska, A.;
Rousseau, A.;
Ryde, F.;
Sabau-Graziati, L.;
Sala, G.;
Salvaterra, R.;
Sanna, A.;
Sandberg, J.;
Scaringi, S.;
Schanne, S.;
Schee, J.;
Schmid, C.;
Shore, S.;
Schneider, R.;
Schwenk, A.;
Schwope, A. D.;
Seyler, J. -Y.;
Shearer, A.;
Smith, A.;
Smith, D. M.;
Smith, P. J.;
Sochora, V.;
Soffitta, P.;
Soleri, P.;
Spencer, A.;
Stappers, B.;
Steiner, A. W.;
Stergioulas, N.;
Stratta, G.;
Strohmayer, T. E.;
Stuchlik, Z.;
Suchy, S.;
Sulemainov, V.;
Takahashi, T.;
Tamburini, F.;
Tauris, T.;
Tenzer, C.;
Tolos, L.;
Tombesi, F.;
Tomsick, J.;
Torok, G.;
Torrejon, J. M.;
Torres, D. F.;
Tramacere, A.;
Trois, A.;
Turolla, R.;
Turriziani, S.;
Uter, P.;
Uttley, P.;
Vacchi, A.;
Varniere, P.;
Vaughan, S.;
Vercellone, S.;
Vrba, V.;
Walton, D.;
Watanabe, S.;
Wawrzaszek, R.;
Webb, N.;
Weinberg, N.;
Wende, H.;
Wheatley, P.;
Wijers, R.;
Wijnands, R.;
Wille, M.;
Wilson-Hodge, C. A.;
Winter, B.;
Wood, K.;
Zampa, G.;
Zampa, N.;
Zampieri, L.;
Zdunik, L.;
Zdziarski, A.;
Zhang, B.;
Zwart, F.;
Ayre, M.;
Boenke, T.;
van Damme, C. Corral;
Kuulkers, E.;
Lumb, D.
Submitted: 2014-08-27, last modified: 2014-08-29
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3
Cosmic Vision framework and participated in the final down-selection for a
launch slot in 2022-2024. Thanks to the unprecedented combination of effective
area and spectral resolution of its main instrument, LOFT will study the
behaviour of matter under extreme conditions, such as the strong gravitational
field in the innermost regions of accretion flows close to black holes and
neutron stars, and the supra-nuclear densities in the interior of neutron
stars. The science payload is based on a Large Area Detector (LAD, 10 m 2
effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of
view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1
arcmin source location accuracy, 300 eV spectral resolution). The WFM is
equipped with an on-board system for bright events (e.g. GRB) localization. The
trigger time and position of these events are broadcast to the ground within 30
s from discovery. In this paper we present the status of the mission at the end
of its Phase A study.
[6]
oai:arXiv.org:1408.6540 [pdf] - 864032
The design of the wide field monitor for LOFT
Brandt, S.;
Hernanz, M.;
Alvarez, L.;
Argan, A.;
Artigues, B.;
Azzarello, P.;
Barret, D.;
Bozzo, E.;
Budtz-Jørgensen;
Campana, R.;
Cros, A.;
del Monte, E.;
Donnarumma, I.;
Evangelista, Y.;
Feroci, M.;
Sanchez, J. L. Galvez;
Götz, D.;
Hansen, F.;
Herder, J. W. den;
Hudec, R.;
Huovelin, J.;
Karelin, D.;
Korpela, S.;
Lund, N.;
Michalska, M.;
Olsen, P.;
Orleanski, P.;
Pedersen, S.;
Pohl, M.;
Rachevski, A.;
Santangelo, A.;
Schanne, S.;
Schmid, C.;
Suchy, S.;
Tenzer, C.;
Vacchi, A.;
Walton, D.;
Wilms, J.;
Zampa, G.;
Zampa, N.;
Zand, J. int;
Zane, S.;
Zdziarski, A.;
Zwart, F.
Submitted: 2014-08-27
LOFT (Large Observatory For x-ray Timing) is one of the ESA M3 missions
selected within the Cosmic Vision program in 2011 to carry out an assessment
phase study and compete for a launch opportunity in 2022-2024. The phase-A
studies of all M3 missions were completed at the end of 2013. LOFT is designed
to carry on-board two instruments with sensitivity in the 2-50 keV range: a 10
m 2 class Large Area Detector (LAD) with a <1{\deg} collimated FoV and a wide
field monitor (WFM) making use of coded masks and providing an instantaneous
coverage of more than 1/3 of the sky. The prime goal of the WFM will be to
detect transient sources to be observed by the LAD. However, thanks to its
unique combination of a wide field of view (FoV) and energy resolution (better
than 500 eV), the WFM will be also an excellent monitoring instrument to study
the long term variability of many classes of X-ray sources. The WFM consists of
10 independent and identical coded mask cameras arranged in 5 pairs to provide
the desired sky coverage. We provide here an overview of the instrument design,
configuration, and capabilities of the LOFT WFM. The compact and modular design
of the WFM could easily make the instrument concept adaptable for other
missions.
[7]
oai:arXiv.org:1309.6995 [pdf] - 1453148
XIPE: the X-ray Imaging Polarimetry Explorer
Soffitta, Paolo;
Barcons, Xavier;
Bellazzini, Ronaldo;
Braga, João;
Costa, Enrico;
Fraser, George W.;
Gburek, Szymon;
Huovelin, Juhani;
Matt, Giorgio;
Pearce, Mark;
Poutanen, Juri;
Reglero, Victor;
Santangelo, Andrea;
Sunyaev, Rashid A.;
Tagliaferri, Gianpiero;
Weisskopf, Martin;
Aloisio, Roberto;
Amato, Elena;
Attiná, Primo;
Axelsson, Magnus;
Baldini, Luca;
Basso, Stefano;
Bianchi, Stefano;
Blasi, Pasquale;
Bregeon, Johan;
Brez, Alessandro;
Bucciantini, Niccoló;
Burderi, Luciano;
Burwitz, Vadim;
Casella, Piergiorgio;
Churazov, Eugene;
Civitani, Marta;
Covino, Stefano;
da Silva, Rui Miguel Curado;
Cusumano, Giancarlo;
Dadina, Mauro;
D'Amico, Flavio;
De Rosa, Alessandra;
Di Cosimo, Sergio;
Di Persio, Giuseppe;
Di Salvo, Tiziana;
Dovciak, Michal;
Elsner, Ronald;
Eyles, Chris J.;
Fabian, Andrew C.;
Fabiani, Sergio;
Feng, Hua;
Giarrusso, Salvatore;
Goosmann, René W.;
Grandi, Paola;
Grosso, Nicolas;
Israel, Gianluca;
Jackson, Miranda;
Kaaret, Philip;
Karas, Vladimir;
Kuss, Michael;
Lai, Dong;
La Rosa, Giovanni;
Larsson, Josefin;
Larsson, Stefan;
Latronico, Luca;
Maggio, Antonio;
Maia, Jorge;
Marin, Frédéric;
Massai, Marco Maria;
Mineo, Teresa;
Minuti, Massimo;
Moretti, Elena;
Muleri, Fabio;
O'Dell, Stephen L.;
Pareschi, Giovanni;
Peres, Giovanni;
Pesce, Melissa;
Petrucci, Pierre-Olivier;
Pinchera, Michele;
Porquet, Delphine;
Ramsey, Brian;
Rea, Nanda;
Reale, Fabio;
Rodrigo, Juana Maria;
Różańska, Agata;
Rubini, Alda;
Rudawy, Pawel;
Ryde, Felix;
Salvati, Marco;
Júnior, Valdivino Alexandre de Santiago;
Sazonov, Sergey;
Sgró, Carmelo;
Silver, Eric;
Spandre, Gloria;
Spiga, Daniele;
Stella, Luigi;
Tamagawa, Toru;
Tamborra, Francesco;
Tavecchio, Fabrizio;
Dias, Teresa Teixeira;
van Adelsberg, Matthew;
Wu, Kinwah;
Zane, Silvia
Submitted: 2013-09-26
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and
temporal variability measurements and to imaging, allows a wealth of physical
phenomena in astrophysics to be studied. X-ray polarimetry investigates the
acceleration process, for example, including those typical of magnetic
reconnection in solar flares, but also emission in the strong magnetic fields
of neutron stars and white dwarfs. It detects scattering in asymmetric
structures such as accretion disks and columns, and in the so-called molecular
torus and ionization cones. In addition, it allows fundamental physics in
regimes of gravity and of magnetic field intensity not accessible to
experiments on the Earth to be probed. Finally, models that describe
fundamental interactions (e.g. quantum gravity and the extension of the
Standard Model) can be tested. We describe in this paper the X-ray Imaging
Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a
small mission with a launch in 2017 but not selected. XIPE is composed of two
out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD)
filled with a He-DME mixture at their focus and two additional GPDs filled with
pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 %
at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half
Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X
optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with
Malindi as down-link station and of a Mission Operation Center (MOC) at INPE
(Brazil).
[9]
oai:arXiv.org:1209.1499 [pdf] - 1151208
The LOFT Wide Field Monitor
Brandt, S.;
Hernanz, M.;
Alvarez, L.;
Azzarello, P.;
Barret, D.;
Bozzo, E.;
Budtz-Jørgensen;
Campana, R.;
del Monte, E.;
Donnarumma, I.;
Evangelista, Y.;
Feroci, M.;
Sanchez, J. L. Galvez;
Götz, D.;
Hansen, F.;
Herder, J. W. den;
Hudec, R.;
Huovelin, J.;
Karelin, D.;
Korpela, S.;
Lund, N.;
Orleanski, P.;
Pohl, M.;
Rachevski, A.;
Santangelo, A.;
Schanne, S.;
Schmid, C.;
Suchy, S.;
Tenzer, C.;
Vacchi, A.;
Wilms, J.;
Zampa, G.;
Zampa, N.;
Zand, J. in't;
Zdziarski, A.
Submitted: 2012-09-07
LOFT (Large Observatory For x-ray Timing) is one of the four missions
selected in 2011 for assessment study for the ESA M3 mission in the Cosmic
Vision program, expected to be launched in 2024. The LOFT mission will carry
two instruments with their prime sensitivity in the 2-30 keV range: a 10 m^2
class large area detector (LAD) with a <1{\deg} collimated field of view and a
wide field monitor (WFM) instrument based on the coded mask principle,
providing coverage of more than 1/3 of the sky. The LAD will provide an
effective area ~20 times larger than any previous mission and will by timing
studies be able to address fundamental questions about strong gravity in the
vicinity of black holes and the equation of state of nuclear matter in neutron
stars. The prime goal of the WFM will be to detect transient sources to be
observed by the LAD. However, with its wide field of view and good energy
resolution of <300 eV, the WFM will be an excellent monitoring instrument to
study long term variability of many classes of X-ray sources. The sensitivity
of the WFM will be 2.1 mCrab in a one day observation, and 270 mCrab in 3s in
observations of in the crowded field of the Galactic Center. The high duty
cycle of the instrument will make it an ideal detector of fast transient
phenomena, like X-ray bursters, soft gamma repeaters, terrestrial gamma
flashes, and not least provide unique capabilities in the study of gamma ray
bursts. A dedicated burst alert system will enable the distribution to the
community of ~100 gamma ray burst positions per year with a ~1 arcmin location
accuracy within 30 s of the burst. This paper provides an overview of the
design, configuration, and capabilities of the LOFT WFM instrument.
[10]
oai:arXiv.org:1209.1497 [pdf] - 1151206
LOFT: the Large Observatory For X-ray Timing
Feroci, M.;
Herder, J. W. den;
Bozzo, E.;
Barret, D.;
Brandt, S.;
Hernanz, M.;
van der Klis, M.;
Pohl, M.;
Santangelo, A.;
Stella, L.;
Watts, A.;
Wilms, J.;
Zane, S.;
Ahangarianabhari, M.;
Alpar, A.;
Altamirano, D.;
Alvarez, L.;
Amati, L.;
Amoros, C.;
Andersson, N.;
Antonelli, A.;
Argan, A.;
Artigue, R.;
Azzarello, P.;
Baldazzi, G.;
Balman, S.;
Barbera, M.;
Belloni, T.;
Bertuccio, G.;
Bianchi, S.;
Bianchini, A.;
Bodin, P.;
Bidaud, J. -M. Bonnet;
Boutloukos, S.;
Braga, J.;
Brown, E.;
Bucciantini, N.;
Burderi, L.;
Bursa, M.;
Budtz-Jørgensen, C.;
Cackett, E.;
Cadoux, F. R.;
Cais, P.;
Caliandro, G. A.;
Campana, R.;
Campana, S.;
Casella, P.;
Chakrabarty, D.;
Chenevez, J.;
Coker, J.;
Cole, R.;
Collura, A.;
Courvoisier, T.;
Cros, A.;
Cumming, A.;
Cusumano, G.;
D'Aì, A.;
D'Elia, V.;
Del Monte, E.;
De Martino, D.;
De Rosa, A.;
Di Cosimo, S.;
Diebold, S.;
Di Salvo, T.;
Donnarumma, I.;
Drago, A.;
Durant, M.;
Emmanoulopoulos, D.;
Evangelista, Y.;
Fabian, A.;
Falanga, M.;
Favre, Y.;
Feldman, C.;
Ferrigno, C.;
Finger, M. H.;
Fraser, G. W.;
Fuschino, F.;
Galloway, D. K.;
Sanchez, J. L. Galvez;
Garcia-Berro, E.;
Gendre, B.;
Gezari, S.;
Giles, A. B.;
Gilfanov, M.;
Giommi, P.;
Giovannini, G.;
Giroletti, M.;
Goldwurm, A.;
Götz, D.;
Gouiffes, C.;
Grassi, M.;
Guidorzi, P. Groot C.;
Haas, D.;
Hansen, F.;
Hartmann, D. H.;
Haswe, C. A.;
Heger, A.;
Homan, J.;
Hornstrup, A.;
Hudec, R.;
Huovelin, J.;
Ingram, A.;
Zand, J. J. M. in't;
Isern, J.;
Israe, G.;
Izzo, L.;
Jonker, P.;
Kaaret, P.;
Karas, V.;
Karelin, D.;
Kataria, D.;
Keek, L.;
Kennedy, T.;
Klochkov, D.;
Kluzniak, W.;
Kokkotas, K.;
Korpela, S.;
Kouveliotou, C.;
Kreykenbohm, I.;
Kuiper, L. M.;
Kuvvetli, I.;
Labanti, C.;
Lai, D.;
Lamb, F. K.;
Lebrun, F.;
Lin, D.;
Linder, D.;
Lodato, G.;
Longo, F.;
Lund, N.;
Maccarone, T. J.;
Macera, D.;
Maier, D.;
Malcovati, P.;
Mangano, V.;
Manousakis, A.;
Marisaldi, M.;
Markowitz, A.;
Martindale, A.;
Matt, G.;
McHardy, I. M.;
Melatos, A.;
Mendez, M.;
Migliari, S.;
Mignani, R.;
Miller, M. C.;
Miller, J. M.;
Mineo, T.;
Miniutti, G.;
Morsink, S.;
Motch, C.;
Motta, S.;
Mouchet, M.;
Muleri, F.;
Norton, A. J.;
Nowak, M.;
O'Brien, P.;
Orienti, M.;
Orio, M.;
Orlandini, M.;
Orleanski, P.;
Osborne, J. P.;
Osten, R.;
Ozel, F.;
Pacciani, L.;
Papitto, A.;
Paul, B.;
Perinati, E.;
Petracek, V.;
Portell, J.;
Poutanen, J.;
Psaltis, D.;
Rambaud, D.;
Ramsay, G.;
Rapisarda, M.;
Rachevski, A.;
Ray, P. S.;
Rea, N.;
Reddy, S.;
Reig, P.;
Aranda, M. Reina;
Remillard, R.;
Reynolds, C.;
Rodríguez-Gil, P.;
Rodriguez, J.;
Romano, P.;
Rossi, E. M. R.;
Ryde, F.;
Sabau-Graziati, L.;
Sala, G.;
Salvaterra, R.;
Sanna, A.;
Schanne, S.;
Schee, J.;
Schmid, C.;
Schwenk, A.;
Schwope, A. D.;
Seyler, J. -Y.;
Shearer, A.;
Smith, A.;
Smith, D. M.;
Smith, P. J.;
Sochora, V.;
Soffitta, P.;
Soleri, P.;
Stappers, B.;
Stelzer, B.;
Stergioulas, N.;
Stratta, G.;
Strohmayer, T. E.;
Stuchlik, Z.;
Suchy, S.;
Sulemainov, V.;
Takahashi, T.;
Tamburini, F.;
Tenzer, C.;
Tolos, L.;
Torok, G.;
Torrejon, J. M.;
Torres, D. F.;
Tramacere, A.;
Trois, A.;
Turriziani, S.;
Uter, P.;
Uttley, P.;
Vacchi, A.;
Varniere, P.;
Vaughan, S.;
Vercellone, S.;
Vrba, V.;
Walton, D.;
Watanabe, S.;
Wawrzaszek, R.;
Webb, N.;
Weinberg, N.;
Wende, H.;
Wheatley, P.;
Wijers, R.;
Wijnands, R.;
Wille, M.;
Wilson-Hodge, C. A.;
Winter, B.;
Wood, K.;
Zampa, G.;
Zampa, N.;
Zampieri, L.;
Zdziarski, A.;
Zhang, B.
Submitted: 2012-09-07
The LOFT mission concept is one of four candidates selected by ESA for the M3
launch opportunity as Medium Size missions of the Cosmic Vision programme. The
launch window is currently planned for between 2022 and 2024. LOFT is designed
to exploit the diagnostics of rapid X-ray flux and spectral variability that
directly probe the motion of matter down to distances very close to black holes
and neutron stars, as well as the physical state of ultra-dense matter. These
primary science goals will be addressed by a payload composed of a Large Area
Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a collimated (<1
degree field of view) experiment operating in the energy range 2-50 keV, with a
10 m^2 peak effective area and an energy resolution of 260 eV at 6 keV. The WFM
will operate in the same energy range as the LAD, enabling simultaneous
monitoring of a few-steradian wide field of view, with an angular resolution of
<5 arcmin. The LAD and WFM experiments will allow us to investigate variability
from submillisecond QPO's to year-long transient outbursts. In this paper we
report the current status of the project.
[11]
oai:arXiv.org:1111.6072 [pdf] - 443797
Simulated performance of a single pixel PIN spectrometer SCXM equipped
with concentrator optics in Solar coronal X-ray observations
Submitted: 2011-11-25, last modified: 2011-11-28
In this paper we present simulated solar coronal X-ray observations to verify
the sensitivity of a new hypothetical instrument design. These simulations are
folded through this X-ray spectrometer having a moderate size circular field of
view of 1.6 degrees. This SCXM (Solar Coronal X-ray Mapper) is designed to
compose of a single pixel silicon PIN detector equipped with a single
reflection double frustum X-ray optics. A moderate FoV would enable a
morphological study of the expanded X-ray emission from the solar corona during
a high activity of the Sun. The main scientific task of SCXM would be the
mapping of the coronal X-ray emission, i.e. to resolve the radial distribution
of the X-ray surface brightness around the Sun. These kind of off-limb
observations would help to interpret the coronal plasma diagnostics as a
function of the elongation angle. Direct solar full disc observations could be
also performed with SCXM. In this work we have applied real solar coronal X-ray
data obtained by the SMART-1 XSM (X-ray Solar Monitor) to simulate on-solar
observations at different flux levels to derive full disc sensitivity and
performance of SCXM. A challenging attempt for SCXM would also be to
distinguish the X-ray spectrum of the decaying axions around the Sun. These
axions are assumed to be created as side products of fusion reactions in the
core of the Sun. These axions are predicted to be gravitationally trapped to
orbit the Sun forming a halo-like X-ray emitting object. No signature of an
axion X-ray emission around the Sun has been observed to this day. This simple
X-ray spectrometer with an optical concentrator would be an inexpensive
instrument with low mass and telemetry budgets compared with more accurate
X-ray instruments of imaging capability. Hence SCXM would be an advanced choice
as an auxiliary instrument for solar coronal X-ray observations.
[12]
oai:arXiv.org:0909.5538 [pdf] - 28959
Cross-Calibration of SMART-1 XSM with GOES and RHESSI
Submitted: 2009-09-30
A number of X-ray instruments have been active in observing the solar coronal
X-ray radiation this decade. We have compared XSM observations with
simultaneous GOES and RHESSI observations. We present flux calibrations for all
instruments, and compare XSM and GOES total emission measures (TEM) and
temperatures (T). The model-independent flux comparison with XSM and GOES data
at the 1 - 8 angstrom band shows that the fluxes agree with a ratio of 0.94 +/-
0.09 for the data up to April 2005. The Mewe model-dependent Ts and TEMs differ
as XSM observes 1.47 +/- 0.03 times higher Ts than GOES and 1.23 +/- 0.08 times
higher TEMs and 0.92 +/- 0.05 times lower fluxes. The comparison with RHESSI
data at the 6 - 8 keV band shows that the average XSM/RHESSI flux ratio is 2.63
+/- 0.23. The discrepancies revealed in this study were similar to
discrepancies observed in a number of other spaceborne cross-calibration
studies.
[13]
oai:arXiv.org:astro-ph/0603507 [pdf] - 80716
Indirect signatures for axion(-like) particles
Zioutas, K.;
Dennerl, K.;
Grande, M.;
Hoffmann, D. H. H.;
Huovelin, J.;
Lakic, B.;
Orlando, S.;
Ortiz, A.;
Papaevangelou, Th.;
Semertzidis, Y.;
Tzamarias, Sp.;
Vilhu, O.
Submitted: 2006-03-18
Magnetic field dependent transient solar observations are suggestive for
axion-photon oscillations with light axion(-like) particle involvement. Novel
dark-moon measurements with the SMART X-ray detectors can be conclusive for
radiatively decaying massive exotica like the generic solar Kaluza-Klein
axions. Furthermore, the predicted intrinsic strong solar magnetic fields could
be the reason of enhanced low energy axion production. Such an axion component
could be the as yet unknown origin of the strong quiet Sun X-ray luminosity at
energies below 1 keV. Solar axion telescopes should lower their threshold,
aiming to copy processes that might occur near the solar surface, be it due to
spontaneous or magnetically induced radiative decay of axion(-like) particles.
This is motivated also by the recent claim of an axion-like particle detection
by the laser experiment PVLAS.
[14]
oai:arXiv.org:astro-ph/0406399 [pdf] - 65556
INTEGRAL monitoring of the Black Hole candidate 1E 1740.7-2942
Del Santo, M.;
Bazzano, A.;
Smith, D. M.;
Bassani, L.;
Bird, A. J.;
Bouchet, L.;
Cadolle-Bel, M.;
Capitanio, F.;
De Cesare, G.;
Falanga, M.;
Frontera, F.;
Goldoni, P.;
Goldwurm, A.;
Huovelin, J.;
Kuulkers, E.;
Lund, N.;
Malaguti, G.;
Malizia, A.;
Mirabel, I. F.;
Natalucci, L.;
Paizis, A.;
Paul, J.;
Reglero, V.;
Ubertini, P.;
Vilhu, O.;
Winkler, C.;
Zdziarski, A.
Submitted: 2004-06-17
The brightest persistent Galactic black hole candidate close to the Galactic
Centre, 1E 1740.7-2942, has long been observed with INTEGRAL. In this paper, we
report on the long-term hard X-ray monitoring obtained during the first year of
observations as part of the Galactic Centre Deep Exposure. We discuss the
temporal and spectral behaviours in different energy bands up to 250 keV, as
well as the hardness-flux correlations.
[15]
oai:arXiv.org:astro-ph/0309287 [pdf] - 59114
JEM-X background models
Submitted: 2003-09-10
Background and determination of its components for the JEM-X X-ray telescope
on INTEGRAL are discussed. A part of the first background observations by JEM-X
are analysed and results are compared to predictions. The observations are
based on extensive imaging of background near the Crab Nebula on revolution 41
of INTEGRAL. Total observing time used for the analysis was 216502 s, with the
average of 25 cps of background for each of the two JEM-X telescopes. JEM-X1
showed slightly higher average background intensity than JEM-X2. The detectors
were stable during the long exposures, and weak orbital phase dependence in the
background outside radiation belts was observed. The analysis yielded an
average of 5 cps for the diffuse background, and 20 cps for the instrument
background. The instrument background was found highly dependent on position,
both for spectral shape and intensity. Diffuse background was enhanced in the
central area of a detector, and it decreased radially towards the edge, with a
clear vignetting effect for both JEM-X units. The instrument background was
weakest in the central area of a detector and showed a steep increase at the
very edges of both JEM-X detectors, with significant difference in spatial
signatures between JEM-X units. According to our modelling, instrument
background dominates over diffuse background in all positions and for all
energies of JEM-X.
[16]
oai:arXiv.org:astro-ph/0208179 [pdf] - 50995
BeppoSAX observations of the EXS 1737.9-2952 region II: Analysis of
sources
Submitted: 2002-08-08
(Abridged) Spectral and time variability analysis of the region of the hard
X-ray transient EXS 1737.9-2952 near the Galactic Centre (GC), using data from
the Narrow Field Instruments of BeppoSAX is reported. The main results are the
MECS spectra of the 10 identified sources. Fluxes obtained with spectral fits
are 1.7-4.8E-12 erg / cm2 s. The absorption is in the range N_H=0.5-6.7E22 /
cm2, indicating that the sources are at least at the distance of the GC, and
thus have L_x > 2-5E34 erg/s (2-10 keV). A powerlaw with photon index 1.1-1.8
generally gives a fair fit, but a strong iron line (at 6-7 keV) is evident for
5 sources and exists at lower confidence in the others. The fits indicate
differences in line position in the range 6.1-7.0 keV suggesting that the
ionisation state and/or emission mechanism may not be the same in all sources.
The time-binned data indicates that two sources are variable on a time scale of
hours at confidence > 99.99%, and one at 99.67%. These sources could be
low-mass X-ray binaries. The other sources are most probably X-ray binaries or
SNRs. A MECS spectrum from a subfield including 8 of the new sources and a
major contribution of diffuse emission yielded a fairly good fit to a power-law
spectrum with photon index 1.3 and a strong iron line at 6.8 keV. Another field
with only residual emission and no point sources yielded spectral parameters
close to the diffuse emission near GC observed by other investigators, except
for the high interstellar absorption. The PDS spectrum of the same region is
more difficult to interpret due to lack of spatial resolution and a larger FOV
that contains the bright hard X-ray source 1E1740.7-2942. The source for the
hard X-ray transient EXS 17137.9-2952 cannot be identified from the present
observations.
[17]
oai:arXiv.org:astro-ph/0207274 [pdf] - 50417
Microflaring of a solar Bright point
Submitted: 2002-07-12
A solar X-ray Bright point (BP) was observed with the SUMER-spectrograph of
the SOHO-observatory. The data consist of four far-UV spectral lines formed
between 2 10^4 - 6 10^5 K, with 2 arcsec spatial, 2.8 min temporal and 4 km/s
spectral resolution. A striking feature is the strong microflaring and
appearance of several short lived transients. Using simultaneous magnetic field
measurements the region observed seemed to lie above a cancelling flux region.
With respect to the filling factor and emission measure this particular BP was
similar to the average surface of a moderately active solar type star.
[18]
oai:arXiv.org:astro-ph/9712292 [pdf] - 99781
UV Spectroscopy of AB Doradus with the Hubble Space Telescope. Impulsive
flares and bimodal profiles of the CIV 1549 line in a young star
Submitted: 1997-12-22
We observed AB Doradus, a young and active late type star (K0 - K2 IV-V, P=
0.514 d) with the Goddard High Resolution Spectrograph of the post-COSTAR
Hubble Space Telescope with the time and spectral resolutions of 27 s and 15
km, respectively. The wavelength band (1531 - 1565 A) included the strong CIV
doublet (1548.202 and 1550.774, formed in the transition region at 100 000 K).
The mean quiescent CIV flux state was close to the saturated value and 100
times the solar one. The line profile (after removing the rotational and
instrumental profiles) is bimodal consisting of two Gaussians, narrow (FWHM =
70 km/s) and broad (FWHM =330km/s). This bimodality is probably due to two
separate broadening mechanisms and velocity fields at the coronal base. It is
possible that TR transient events (random multiple velocities), with a large
surface coverage, give rise to the broadening of the narrow component,while
true microflaring is responsible for the broad one.
The transition region was observed to flare frequently on different time
scales and magnitudes. The largest impulsive flare seen in the CIV 1549
emission reached in less than one minute the peak differential emission measure
(10**51.2 cm-3) and returned exponentially in 5 minutes to the 7 times lower
quiescent level.The 3 min average line profile of the flare was blue-shifted
(-190 km/s) and broadened (FWHM = 800 km/s). This impulsive flare could have
been due to a chromospheric heating and subsequent evaporation by an electron
beam, accelerated (by reconnection) at the apex of a coronal loop.
[19]
oai:arXiv.org:physics/9703001 [pdf] - 119220
Transmission properties of the X-ray window for the SIXA spectrometer
Submitted: 1997-02-28
The ultrathin X-ray entrance window for the spaceborne spectrometer SIXA was
characterised using synchrotron radiation. X-ray absorption fine structure near
the absorption edges of the constituting elements (aluminium, carbon, oxygen
and nitrogen) was measured. Large scale positional variations were also
studied. In addition, the opacity of the window was tested by observing the
effect of photocurrent in the detector generated by light leaked through the
window.
[20]
oai:arXiv.org:astro-ph/9612194 [pdf] - 96222
The Great Annihilator 1E1740.7-2942: Molecular cloud connection and
coronal structure
Submitted: 1996-12-19
Using 12CO and 13CO observations we present column density maps of the
molecular cloud (V = -135 km/s) in the direction of 1E1740.7-2942. Hydrogen
column densities of the cloud scatter between (3.5 - 11) 10**22 cm-2, depending
on the method used. From this we conclude, deriving first a simple analytic
formula, that despite of the weakness of the iron fluorescent 6.4 keV line
(Churazov et al. 1996), the source may lie inside the cloud, or at least close
to its edge. The combined ASCA/BATSE spectrum from September 1993 and 1994 can
be modelled with a two-phase accretion disc corona model, where the hot region
is detached from the cold disc. Geometrically, the hot phase can be interpreted
e.g. as a number of active regions (magnetic loops) above the disc, or as a
spherical hot cloud around the central object.