Normalized to: Humbert, V.
[1]
oai:arXiv.org:1706.01070 [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter
searches
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Maisonobe, R.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.;
Zolotarova, A.
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the
EDELWEISS-III array of cryogenic germanium detectors for direct dark matter
searches. The experimental setup and the FID (Fully Inter-Digitized) detector
array is described, as well as the efficiency of the double measurement of heat
and ionization signals in background rejection. For the whole set of 24 FID
detectors used for coincidence studies, the baseline resolutions for the
fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the
baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM).
The response to nuclear recoils as well as the very good discrimination
capability of the FID design has been measured with an AmBe source. The surface
$\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times
10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source,
the rejection of bulk $\gamma$-ray events has been demonstrated using
$\gamma$-calibrations with $^{133}$Ba sources leading to a value of
$R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels
of natural radioactivity measured in the detector array are shown as the rate
of single $\gamma$ background. The fiducial volume fraction of the FID
detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$
using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The
stability and uniformity of the detector response is also discussed. The
achieved resolutions, thresholds and background levels of the upgraded
EDELWEISS-III detectors in their setup are thus well suited to the direct
search of WIMP dark matter over a large mass range.
[2]
oai:arXiv.org:1603.05120 [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
De Jésus, M.;
Jin, Y.;
Jokisch, S.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D. V.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark
matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30
GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an
array of 800 g Germanium bolometers equipped with a set of interleaved
electrodes with full surface coverage. We searched specifically for $\sim
2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an
illustration the number of observed events in the search for 5 (resp. 20)
GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1
(resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times
10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering
cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a
41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP
search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints
of WIMP signals from some recent experiments, thus confirming results obtained
with different detection techniques.
[3]
oai:arXiv.org:1307.1488 [pdf] - 844079
Axion searches with the EDELWEISS-II experiment
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoit, A.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
de Boissière, T.;
De Jesus, M.;
Dolgorouky, Y.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Holtzer, N.;
Humbert, V.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Mancuso, M.;
Marrache-Kikuchi, C.;
Marnieros, S.;
Menshikov, A.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. C.;
Rigaut, O.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Tenconi, M.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-07-04
We present new constraints on the couplings of axions and more generic
axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS
experiment, located at the Underground Laboratory of Modane, primarily aims at
the direct detection of WIMPs using germanium bolometers. It is also sensitive
to the low-energy electron recoils that would be induced by solar or dark
matter axions. Using a total exposure of up to 448 kg.d, we searched for
axion-induced electron recoils down to 2.5 keV within four scenarios involving
different hypotheses on the origin and couplings of axions. We set a 95% CL
limit on the coupling to photons $g_{A\gamma}<2.13\times 10^{-9}$ GeV$^{-1}$ in
a mass range not fully covered by axion helioscopes. We also constrain the
coupling to electrons, $g_{Ae} < 2.56\times 10^{-11}$, similar to the more
indirect solar neutrino bound. Finally we place a limit on $g_{Ae}\times
g_{AN}^{\rm eff}<4.70 \times 10^{-17}$, where $g_{AN}^{\rm eff}$ is the
effective axion-nucleon coupling for $^{57}$Fe. Combining these results we
fully exclude the mass range $0.91\,{\rm eV}<m_A<80$ keV for DFSZ axions and
$5.73\,{\rm eV}<m_A<40$ keV for KSVZ axions.