Normalized to: Huber, H.
[1]
oai:arXiv.org:1807.05089 [pdf] - 1715413
ERIS: revitalising an adaptive optics instrument for the VLT
Davies, Richard;
Esposito, Simone;
Schmid, Hans Martin;
Taylor, William;
Agapito, Guido;
Berbel, Alexander Agudo;
Baruffolo, Andrea;
Biliotti, Valdemaro;
Biller, Beth;
Black, Martin;
Boehle, Anna;
Briguglio, Runa;
Buron, Alexander;
Carbonaro, Luca;
Cortes, Angela;
Cresci, Giovanni;
Deysenroth, Matthias;
Di Cianno, Amico;
Di Rico, Gianluca;
Doelman, David;
Dolci, Mauro;
Dorn, Reinhold;
Eisenhauer, Frank;
Fantinel, Daniela;
Ferruzzi, Debora;
Feuchtgruber, Helmut;
Schreiber, Natascha Förster;
Gao, Xiaofeng;
Gemperlein, Hans;
Genzel, Reinhard;
George, Elizabeth;
Gillessen, Stefan;
Giordano, Christophe;
Glauser, Adrian;
Glindemann, Andreas;
Grani, Paolo;
Hartl, Michael;
Heijmans, Jeroen;
Henry, David;
Huber, Heinrich;
Kasper, Markus;
Keller, Christoph;
Kenworthy, Matthew;
Kuehn, Jonas;
Kuntschner, Harald;
Lightfood, John;
Lunney, David;
MacIntosh, Mike;
Mannucci, Filippo;
March, Stephen;
Neeser, Mark;
Patapis, Polychronis;
Pearson, David;
Plattner, Markus;
Puglisi, Alfio;
Quanz, Sascha;
Rau, Christian;
Riccardi, Armando;
Salasnich, Bernardo;
Schubert, Josef;
Snik, Frans;
Sturm, Eckhard;
Valentini, Angelo;
Waring, Christopher;
Wiezorrek, Erich;
Xompero, Marco
Submitted: 2018-07-13
ERIS is an instrument that will both extend and enhance the fundamental
diffraction limited imaging and spectroscopy capability for the VLT. It will
replace two instruments that are now being maintained beyond their operational
lifetimes, combine their functionality on a single focus, provide a new
wavefront sensing module that makes use of the facility Adaptive Optics System,
and considerably improve their performance. The instrument will be competitive
with respect to JWST in several regimes, and has outstanding potential for
studies of the Galactic Center, exoplanets, and high redshift galaxies. ERIS
had its final design review in 2017, and is expected to be on sky in 2020. This
contribution describes the instrument concept, outlines its expected
performance, and highlights where it will most excel.
[2]
oai:arXiv.org:1707.08923 [pdf] - 1586466
Complex spectral line profiles resulting from cryogenic deformation of
the SINFONI/SPIFFI diffraction gratings
Submitted: 2017-07-27
The integral field spectrograph, SPIFFI, has complex line profile shapes that
vary with wavelength and pixel scale, the origins of which have been sought
since the instrument construction. SPIFFI is currently operational as part of
SINFONI at the VLT, and will be upgraded and incorporated into the new VLT
instrument ERIS. We conducted an investigation of the line profiles based on
measurements we could take with the instrument calibration unit, as well as
laboratory measurements of spare SPIFFI optical components. Cryogenic
measurements of a spare SPIFFI diffraction grating showed significant periodic
deformation. These measurements match the cryogenic deformation expected from
bimetallic bending stress based on a finite element analysis of the
lightweighted grating blank. The periodic deformation of the grating surface
gives rise to satellite peaks in the diffraction pattern of the grating. An
optical simulation including the cryogenic grating deformation reproduces the
behavior of the SPIFFI line profiles with both wavelength and pixel scale as
measured with the instrument calibration unit. The conclusion is that cryogenic
deformation of the diffraction gratings is responsible for the non-ideal line
profiles, and that the diffraction gratings should be replaced during the
upgrade for optimal instrument performance.
[3]
oai:arXiv.org:1608.02457 [pdf] - 1507611
Making SPIFFI SPIFFIER: Upgrade of the SPIFFI instrument for use in ERIS
and performance analysis from re-commissioning
George, E. M.;
Gräff, D.;
Feuchtgruber, H.;
Hartl, M.;
Eisenhauer, F.;
Buron, A.;
Davies, R.;
Genzel, R.;
Huber, H.;
Rau, C.;
Plattner, M.;
Wiezorrek, E.;
Weisz, H.;
Amico, P.;
Glindeman, A.;
Hau, G.;
Kuntschner, H.;
Modigliani, A.
Submitted: 2016-08-08, last modified: 2016-11-02
SPIFFI is an AO-fed integral field spectrograph operating as part of SINFONI
on the VLT, which will be upgraded and reused as SPIFFIER in the new VLT
instrument ERIS. In January 2016, we used new technology developments to
perform an early upgrade to optical subsystems in the SPIFFI instrument so
ongoing scientific programs can make use of enhanced performance before ERIS
arrives in 2020. We report on the upgraded components and the performance of
SPIFFI after the upgrade, including gains in throughput and spatial and
spectral resolution. We show results from re-commissioning, highlighting the
potential for scientific programs to use the capabilities of the upgraded
SPIFFI. Finally, we discuss the additional upgrades for SPIFFIER which will be
implemented before it is integrated into ERIS.
[4]
oai:arXiv.org:1609.01507 [pdf] - 1475588
Extreme Scale-out SuperMUC Phase 2 - lessons learned
Hammer, Nicolay;
Jamitzky, Ferdinand;
Satzger, Helmut;
Allalen, Momme;
Block, Alexander;
Karmakar, Anupam;
Brehm, Matthias;
Bader, Reinhold;
Iapichino, Luigi;
Ragagnin, Antonio;
Karakasis, Vasilios;
Kranzlmüller, Dieter;
Bode, Arndt;
Huber, Herbert;
Kühn, Martin;
Machado, Rui;
Grünewald, Daniel;
Edelmann, Philipp V. F.;
Röpke, Friedrich K.;
Wittmann, Markus;
Zeiser, Thomas;
Wellein, Gerhard;
Mathias, Gerald;
Schwörer, Magnus;
Lorenzen, Konstantin;
Federrath, Christoph;
Klessen, Ralf;
Bamberg, Karl-Ulrich;
Ruhl, Hartmut;
Schornbaum, Florian;
Bauer, Martin;
Nikhil, Anand;
Qi, Jiaxing;
Klimach, Harald;
Stüben, Hinnerk;
Deshmukh, Abhishek;
Falkenstein, Tobias;
Dolag, Klaus;
Petkova, Margarita
Submitted: 2016-09-06
In spring 2015, the Leibniz Supercomputing Centre (Leibniz-Rechenzentrum,
LRZ), installed their new Peta-Scale System SuperMUC Phase2. Selected users
were invited for a 28 day extreme scale-out block operation during which they
were allowed to use the full system for their applications. The following
projects participated in the extreme scale-out workshop: BQCD (Quantum
Physics), SeisSol (Geophysics, Seismics), GPI-2/GASPI (Toolkit for HPC),
Seven-League Hydro (Astrophysics), ILBDC (Lattice Boltzmann CFD), Iphigenie
(Molecular Dynamic), FLASH (Astrophysics), GADGET (Cosmological Dynamics), PSC
(Plasma Physics), waLBerla (Lattice Boltzmann CFD), Musubi (Lattice Boltzmann
CFD), Vertex3D (Stellar Astrophysics), CIAO (Combustion CFD), and LS1-Mardyn
(Material Science). The projects were allowed to use the machine exclusively
during the 28 day period, which corresponds to a total of 63.4 million
core-hours, of which 43.8 million core-hours were used by the applications,
resulting in a utilization of 69%. The top 3 users were using 15.2, 6.4, and
4.7 million core-hours, respectively.
[5]
oai:arXiv.org:1407.6669 [pdf] - 861906
The GRAVITY metrology system: modeling a metrology in optical fibers
Blind, N.;
Huber, H.;
Eisenhauer, F.;
Weber, J.;
Gillessen, S.;
Lippa, M.;
Burtscher, L.;
Hans, O.;
Haug, M.;
Haussmann, F.;
Huber, S.;
Janssen, A.;
Kellner, S.;
Kok, Y.;
Ott, T.;
Pfuhl, O.;
Sturm, E.;
Wieprecht, E.;
Amorim, A.;
Brandner, W.;
Perrin, G.;
Perraut, K.;
Straubmeier, C.
Submitted: 2014-07-24
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for
high-precision narrow-angle astrometry and phase-referenced interferometric
imaging. The laser metrology system of GRAVITY is at the heart of its
astrometric mode, which must measure the distance of 2 stars with a precision
of 10 micro-arcseconds. This means the metrology has to measure the optical
path difference between the two beam combiners of GRAVITY to a level of 5 nm.
The metrology design presents some non-common paths that have consequently to
be stable at a level of 1 nm. Otherwise they would impact the performance of
GRAVITY. The various tests we made in the past on the prototype give us hints
on the components responsible for this error, and on their respective
contribution to the total error. It is however difficult to assess their exact
origin from only OPD measurements, and therefore, to propose a solution to this
problem. In this paper, we present the results of a semi-empirical modeling of
the fibered metrology system, relying on theoretical basis, as well as on
characterisations of key components. The modeling of the metrology system
regarding various effects, e.g., temperature, waveguide heating or mechanical
stress, will help us to understand how the metrology behave. The goals of this
modeling are to 1) model the test set-ups and reproduce the measurements (as a
validation of the modeling), 2) determine the origin of the non-common path
errors, and 3) propose modifications to the current metrology design to reach
the required 1nm stability.
[6]
oai:arXiv.org:0801.4801 [pdf] - 9596
GROND - a 7-channel imager
Greiner, J.;
Bornemann, W.;
Clemens, C.;
Deuter, M.;
Hasinger, G.;
Honsberg, M.;
Huber, H.;
Huber, S.;
Krauss, M.;
Krühler, T.;
Yoldaş, A. Küpcü;
Mayer-Hasselwander, H.;
Mican, B.;
Primak, N.;
Schrey, F.;
Steiner, I.;
Szokoly, G.;
Thöne, C. C.;
Yoldaş, A.;
Klose, S.;
Laux, U.;
Winkler, J.
Submitted: 2008-01-30
We describe the construction of GROND, a 7-channel imager, primarily designed
for rapid observations of gamma-ray burst afterglows. It allows simultaneous
imaging in the Sloan g'r'i'z' and near-infrared $JHK$ bands. GROND was
commissioned at the MPI/ESO 2.2m telescope at La Silla (Chile) in April 2007,
and first results of its performance and calibration are presented.
[7]
oai:arXiv.org:astro-ph/9811463 [pdf] - 1235285
Compatibility of neutron star masses and hyperon coupling constants
Submitted: 1998-11-30
It is shown that the modern equations of state for neutron star matter based
on microscopic calculations of symmetric and asymmetric nuclear matter are
compatible with the lower bound on the maximum neutron-star mass for a certain
range of hyperon coupling constants, which are constrained by the binding
energies of hyperons in symmetric nuclear matter. The hyperons are included by
means of the relativistic Hartree-- or Hartree--Fock approximation. The
obtained couplings are also in satisfactory agreement with hypernuclei data in
the relativistic Hartree scheme. Within the relativistic Hartree--Fock
approximation hypernuclei have not been investigated so far.
[8]
oai:arXiv.org:nucl-th/9803026 [pdf] - 118905
Symmetric and asymmetric nuclear matter in the relativistic approach at
finite temperatures
Submitted: 1998-03-09
The properties of hot matter are studied in the frame of the relativistic
Brueckner-Hartree-Fock theory. The equations are solved self-consistently in
the full Dirac space. For the interaction we used the potentials given by
Brockmann and Machleidt. The obtained critical temperatures are smaller than in
most of the nonrelativistic investigations. We also calculated the
thermodynamic properties of hot matter in the relativistic Hartree--Fock
approximation, where the force parameters were adjusted to the outcome of the
relativistic Brueckner--Hartree--Fock calculations at zero temperature. Here,
one obtains higher critical temperatures, which are comparable with other
relativistic calculations in the Hartree scheme.
[9]
oai:arXiv.org:nucl-th/9711025 [pdf] - 118887
Neutron star properties with relativistic equations of state
Submitted: 1997-11-12
We study the properties of neutron stars adopting relativistic equations of
state of neutron star matter, calculated in the framework of the relativistic
Brueckner-Hartree-Fock approximation for electrically charge neutral neutron
star matter in beta-equilibrium. For higher densities more baryons (hyperons
etc.) are included by means of the relativistic Hartree- or Hartree-Fock
approximation. The special features of the different approximations and
compositions are discussed in detail. Besides standard neutron star properties
special emphasis is put on the limiting periods of neutron stars, for which the
Kepler criterion and gravitation-reaction instabilities are considered.
Furthermore the cooling behaviour of neutron stars is investigated, too. For
comparison we give also the outcome for some nonrelativistic equations of
state.