sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Hotz, M.

Normalized to: Hotz, M.

6 article(s) in total. 31 co-authors, from 1 to 6 common article(s). Median position in authors list is 6,5.

[1]  oai:arXiv.org:1804.08770  [pdf] - 1670744
Modulation Sensitive Search for Non-Virialized Dark-Matter Axions
Comments: 12 pages, 12 figures
Submitted: 2018-04-23
Non-virialized dark-matter axions may be present in the Milky Way halo in the form of low-velocity-dispersion flows. The Axion Dark Matter eXperiment performed a search for the conversion of these axions into microwave photons using a resonant cavity immersed in a strong, static magnetic field. The spread of photon energy in these measurements was measured at spectral resolutions of the order of 1 Hz and below. If the energy variation were this small, the frequency modulation of any real axion signal due to the orbital and rotational motion of the Earth would become non-negligible. Conservative estimates of the expected signal modulation were made and used as a guide for the search procedure. The photon frequencies covered by this search are 812$-$852 and 858$-$892 MHz, which correspond to an axion mass of 3.36$-$3.52 and 3.55$-$3.69 {\mu}eV. No axion signal was found, and limits were placed on the maximum local density of non-virialized axions of these masses.
[2]  oai:arXiv.org:1109.4128  [pdf] - 1084216
A search for non-virialized axionic dark matter
Comments: 4 pages, 4 figures, Accepted to be published in PRD Rapid Communications
Submitted: 2011-09-19, last modified: 2011-11-17
Cold dark matter in the Milky Way halo may have structure defined by flows with low velocity dispersion. The Axion Dark Matter eXperiment high resolution channel is especially sensitive to axions in such low velocity dispersion flows. Results from a combined power spectra analysis of the high resolution channel axion search are presented along with a discussion of the assumptions underlying such an analysis. We exclude KSVZ axion dark matter densities of {\rho} > 0.2 GeV/cm^3 and DFSZ densities of {\rho} > 1.4 GeV/cm^3 over a mass range of m_a = 3.3{\mu}eV to 3.69{\mu}eV for models having velocity dispersions of {\Delta}{\beta} < 3x10^-6.
[3]  oai:arXiv.org:1105.4203  [pdf] - 966847
Design and performance of the ADMX SQUID-based microwave receiver
Comments: 8 pages, 12 figures, Submitted to Nuclear Inst. and Methods in Physics Research, A
Submitted: 2011-05-20
The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly interacting relic axion particles by searching for their conversion to microwave photons in a resonant cavity positioned in a strong magnetic field. Given the extremely low expected axion-photon conversion power we have designed, built and operated a microwave receiver based on a Superconducting QUantum Interference Device (SQUID). We describe the ADMX receiver in detail as well as the analysis of narrow band microwave signals. We demonstrate the sustained use of a SQUID amplifier operating between 812 and 860 MHz with a noise temperature of 1 K. The receiver has a noise equivalent power of 1.1x10^-24 W/sqrt(Hz) in the band of operation for an integration time of 1.8x10^3 s.
[4]  oai:arXiv.org:1007.3766  [pdf] - 250071
A Search for Hidden Sector Photons with ADMX
Comments: 4 pages, 4 figures, published in PRL
Submitted: 2010-07-21, last modified: 2010-10-28
Hidden U(1) gauge symmetries are common to many extensions of the Standard Model proposed to explain dark matter. The hidden gauge vector bosons of such extensions may mix kinetically with Standard Model photons, providing a means for electromagnetic power to pass through conducting barriers. The ADMX detector was used to search for hidden vector bosons originating in an emitter cavity driven with microwave power. We exclude hidden vector bosons with kinetic couplings {\chi} > 3.48x10-8 for masses less than 3 {\mu}eV. This limit represents an improvement of more than two orders of magnitude in sensitivity relative to previous cavity experiments.
[5]  oai:arXiv.org:1004.5160  [pdf] - 903114
A Search for Scalar Chameleons with ADMX
Comments: 4 pages, 3 figures
Submitted: 2010-04-28
Scalar fields with a "chameleon" property, in which the effective particle mass is a function of its local environment, are common to many theories beyond the standard model and could be responsible for dark energy. If these fields couple weakly to the photon, they could be detectable through the "afterglow" effect of photon-chameleon-photon transitions. The ADMX experiment was used in the first chameleon search with a microwave cavity to set a new limit on scalar chameleon-photon coupling excluding values between 2*10^9 and 5*10^14 for effective chameleon masses between 1.9510 and 1.9525 micro-eV.
[6]  oai:arXiv.org:0910.5914  [pdf] - 142256
A SQUID-based microwave cavity search for dark-matter axions
Comments: 4 pages, 5 figures, submitted to PRL
Submitted: 2009-10-30
Axions in the micro eV mass range are a plausible cold dark matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. The first result from such an axion search using a superconducting first-stage amplifier (SQUID) is reported. The SQUID amplifier, replacing a conventional GaAs field-effect transistor amplifier, successfully reached axion-photon coupling sensitivity in the band set by present axion models and sets the stage for a definitive axion search utilizing near quantum-limited SQUID amplifiers.