Normalized to: Hosokawa, K.
[1]
oai:arXiv.org:2006.04289 [pdf] - 2109337
Plasma sheet thinning due to loss of near-Earth magnetotail plasma
Submitted: 2020-06-07
A one-dimensional model for thinning of the Earth's plasma sheet [J. K. Chao
et al., Planet. Space Sci. 25, 703 (1977)] according to the Current Disruption
(CD) model of auroral breakup is extended to two dimensions. A rarefaction
wave, which is a signature component of the CD model, is generated with an
initial disturbance. In the 1D gas model, the rarefaction wave propagates
tailward at sound velocity and is assumed to cause thinning. Extending to a 2D
gas model of a simplified plasma sheet configuration, the rarefaction wave is
weakened, and the thinning ceases to propagate. Extending further to a 2D
plasma model by adding magnetic field into the lobes, the rarefaction wave is
quickly lost in the plasma sheet recompression, but the plasma sheet thinning
is still present and propagates independently at a slower velocity than a 1D
model suggests. This shows that the dynamics of plasma sheet thinning may be
dominated by sheet-lobe interactions that are absent from the 1D model and may
not support the behaviour assumed by the CD model.
[2]
oai:arXiv.org:1808.03617 [pdf] - 1822844
Development of low radioactivity photomultiplier tubes for the XMASS-I
detector
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-08-10, last modified: 2019-01-29
XMASS-I is a single-phase liquid xenon detector whose purpose is direct
detection of dark matter. To achieve the low background requirements necessary
in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a
hexagonal window was developed based on the R8778 PMT used in the XMASS
prototype detector. We screened the numerous component materials for their
radioactivity. During development, the largest contributions to the reduction
of radioactivity came from the stem and the dynode support. The glass stem was
exchanged to the Kovar alloy one and the ceramic support were changed to the
quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted
these materials for low background purposes and provided a groundbreaking step
for further reductions of radioactivity in PMTs. Measurements with germanium
detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of
$^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of
$^{60}$Co. In this paper, the radioactive details of the developed R10789 are
described together with our screening methods and the components of the PMT.
[3]
oai:arXiv.org:1804.02180 [pdf] - 1806000
A direct dark matter search in XMASS-I
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-04-06, last modified: 2018-12-25
A search for dark matter using an underground single-phase liquid xenon
detector was conducted at the Kamioka Observatory in Japan, particularly for
Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of
data in a fiducial volume containing 97 kg of liquid xenon at the center of the
detector. The event rate in the fiducial volume after the data reduction was
${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm
5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining
events are consistent with our background evaluation, mostly of the
"mis-reconstructed events" originated from $^{210}$Pb in the copper plates
lining the detector's inner surface. The obtained upper limit on a
spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \,
cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence
level, which was the most stringent limit among results from single-phase
liquid xenon detectors.
[4]
oai:arXiv.org:1801.10096 [pdf] - 1690355
Direct dark matter search by annual modulation with 2.7 years of XMASS-I
data
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-01-30, last modified: 2018-05-25
An annual modulation signal due to the Earth orbiting around the Sun would be
one of the strongest indications of the direct detection of dark matter. In
2016, we reported a search for dark matter by looking for this annual
modulation with our single-phase liquid xenon XMASS-I detector. That analysis
resulted in a slightly negative modulation amplitude at low energy. In this
work, we included more than one year of additional data, which more than
doubles the exposure to 800 live days with the same 832 kg target mass. When we
assume weakly interacting massive particle (WIMP) dark matter elastically
scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon
cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8
GeV/c$^2$ at 90\% confidence level with our newly implemented data selection
through a likelihood method. For the model-independent case, without assuming
any specific dark matter model, we obtained more consistency with the null
hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy
region. This search probed this region with an exposure that was larger than
that of DAMA/LIBRA. We also did not find any significant amplitude in the data
for periodicity with periods between 50 and 600 days in the energy region
between 1 to 6 keV.
[5]
oai:arXiv.org:1712.07762 [pdf] - 1607081
Developing post-coronagraphic, high-resolution spectroscopy for
terrestrial planet characterization on ELTs
Jovanovic, N.;
Guyon, O.;
Kotani, T.;
Kawahara, H.;
Hosokawa, K.;
Lozi, J.;
Males, J.;
Ireland, M.;
Tamura, M.;
Mawet, D.;
Schwab, C.;
Norris, B.;
Leon-Saval, S.;
Betters, C.;
Tuthill, P.
Submitted: 2017-12-20, last modified: 2017-12-22
Spectroscopic observations are extremely important for determining the
composition, structure, and surface gravity of exoplanetary atmospheres. High
resolution spectroscopy of the planet itself has only been demonstrated a
handful of times. By using advanced high contrast imagers, it is possible to
conduct high resolution spectroscopy on imageable exoplanets, after the star
light is first suppressed with an advanced coronagraph. Because the planet is
spatially separated in the focal plane, a single mode fiber could be used to
collect the light from the planet alone, reducing the photon noise by orders of
magnitude. In addition, speckle control applied to the location where an
exoplanet is known to exist, can be used to preferentially reject the stellar
flux from the fiber further.
In this paper we will present the plans for conducting high resolution
spectroscopic studies of this nature with the combination of SCExAO and IRD in
the H-band on the Subaru Telescope. This technique will be critical to the
characterization of terrestrial planets on ELTs and future space missions.
[6]
oai:arXiv.org:1707.08995 [pdf] - 1586478
Search for solar Kaluza-Klein axion by annual modulation with the
XMASS-I detector
XMASS Collaboration;
Oka, N.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2017-07-19, last modified: 2017-11-15
In theories with the large extra dimensions beyond the standard 4-dimensional
spacetime, axions could propagate in such extra dimensions, and acquire
Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and
could solve unexplained heating of the solar corona. While most of the solar KK
axions escape from the solar system, a small fraction is gravitationally
trapped in orbits around the Sun. They would decay into two photons inside a
terrestrial detector. The event rate is expected to modulate annually depending
on the distance from the Sun. We have searched for the annual modulation
signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant
event rate modulation is found, and hence we set the first experimental
constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\,
\mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of
$\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number
of extra dimensions $n = 2$, and the number of extra dimensions $\delta = 2$
that axions can propagate in.
[7]
oai:arXiv.org:1604.01503 [pdf] - 1458949
A measurement of the time profile of scintillation induced by low energy
gamma-rays in liquid xenon with the XMASS-I detector
XMASS Collaboration;
Takiya, H.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kegasa, R.;
Kobayashi, K.;
Masuda, K.;
Fushimi, K.;
Martens, K.;
Suzuki, Y.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Onishi, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, J. S.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Nishijima, K.;
Nakamura, S.
Submitted: 2016-04-06, last modified: 2016-08-18
We report the measurement of the emission time profile of scintillation from
gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation
detector. Decay time constant was derived from a comparison of scintillation
photon timing distributions between the observed data and simulated samples in
order to take into account optical processes such as absorption and scattering
in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe,
$^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming
two decay components, $\tau_1$ and $\tau_2$, the decay time constant $\tau_2$
increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9
keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all
energy levels. A fast decay component with $\tau_1 \sim 2$ ns was necessary to
reproduce data. Energy dependencies of $\tau_2$ and the fraction of the fast
decay component were studied as a function of the kinetic energy of electrons
induced by gamma-rays. The obtained data almost reproduced previously reported
results and extended them to the lower energy region relevant to direct dark
matter searches.
[8]
oai:arXiv.org:1511.04807 [pdf] - 1413079
Direct dark matter search by annual modulation in XMASS-I
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Tasaka, S.;
Fushimi, K.;
Liu, J.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Onishi, Y.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, J. S.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Itow, Y.;
Kegasa, R.;
Kobayashi, K.;
Masada, K.;
Takiya, H.;
Nishijima, K.;
Nakamura, S.
Submitted: 2015-11-15, last modified: 2016-05-25
A search for dark matter was conducted by looking for an annual modulation
signal due to the Earth's rotation around the Sun using XMASS, a single phase
liquid xenon detector. The data used for this analysis was 359.2 live days
times 832 kg of exposure accumulated between November 2013 and March 2015. When
we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically
scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon
cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we
exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range
at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without
assuming any specific dark matter model but including electron/$\gamma$ events,
showed a slight negative amplitude. The $p$-values obtained with two
independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we
obtained 90\% C.L. upper bounds that can be used to test various models. This
is the first extensive annual modulation search probing this region with an
exposure comparable to DAMA/LIBRA.
[9]
oai:arXiv.org:1406.0502 [pdf] - 869600
Search for bosonic superweakly interacting massive dark matter particles
with the XMASS-I detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Ichimura, K.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-06-02, last modified: 2014-08-21
Bosonic superweakly interacting massive particles (super-WIMPs) are a
candidate for warm dark matter. With the absorption of such a boson by a xenon
atom these dark matter candidates would deposit an energy equivalent to their
rest mass in the detector. This is the first direct detection experiment
exploring the vector super-WIMPs in the mass range between 40 and 120 keV.
Using 165.9 days of data no significant excess above background was observed in
the fiducial mass of 41 kg. The present limit for the vector super-WIMPs
excludes the possibility that such particles constitute all of dark matter. The
absence of a signal also provides the most stringent direct constraint on the
coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented
sensitivity was achieved exploiting the low background at a level $10^{-4}$
kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
[10]
oai:arXiv.org:1401.4737 [pdf] - 1425198
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from
the XMASS-I experiment
Uchida, H.;
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-01-19, last modified: 2014-04-29
A search for inelastic scattering of Weakly Interacting Massive Particles
(WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase
liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted
volume containing 41 kg of LXe at the very center of our detector we observed
no significant excess of events in 165.9 days of data. Our background reduction
allowed us to derive our limits without explicitly subtracting the remaining
events which are compatible with background expectations and derive for e.g. a
50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei
of 3.2 pb at the 90% confidence level.
[11]
oai:arXiv.org:1212.6153 [pdf] - 753387
Search for solar axions in XMASS, a large liquid-xenon detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Suzuki, A. Shinozaki Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2012-12-26, last modified: 2013-05-29
XMASS, a low-background, large liquid-xenon detector, was used to search for
solar axions that would be produced by bremsstrahlung and Compton effects in
the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent
limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$
(90% C.L.), which is a factor of two stronger than the existing experimental
limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are
1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced
the most stringent limit, which is better than that previously derived from
astrophysical arguments regarding the Sun to date.
[12]
oai:arXiv.org:1211.5404 [pdf] - 620998
Light WIMP search in XMASS
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Suzuki, A. Shinozaki Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2012-11-22, last modified: 2013-01-16
A search for light dark matter using low-threshold data from the single phase
liquid xenon scintillation detector XMASS, has been conducted. Using the entire
835 kg inner volume as target, the analysis threshold can be lowered to 0.3
keVee (electron-equivalent) to search for light dark matter. With low-threshold
data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and
without discriminating between nuclear-recoil and electronic events, XMASS
excludes part of the parameter space favored by other experiments.
[13]
oai:arXiv.org:1301.2815 [pdf] - 831840
XMASS detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Nishiie, H.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Nishitani, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2013-01-13
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar
neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon.
The first phase of the XMASS experiment searches for dark matter. In this
paper, we describe the XMASS detector in detail, including its configuration,
data acquisition equipment and calibration system.