Normalized to: Horville, D.
[1]
oai:arXiv.org:1909.11450 [pdf] - 1968540
Assessment of the GCT prototype's optical system implementation and
other key performances for the Cherenkov Telescope Array
Dmytriiev, A.;
Dangeon, L.;
Fasola, G.;
Sol, H.;
Zech, A.;
Gironnet, J.;
Blanc, O. Le;
Amans, J. P.;
Buchholtz, G.;
Dournaux, J. L.;
de Frondat, F.;
Horville, D.;
Huet, J. M.;
Jégouzo, I.;
Laporte, P.
Submitted: 2019-09-25
The Cherenkov Telescope Array (CTA) project, led by an international
collaboration of institutes, aims to create the world's largest next generation
observatory for Very High Energy (VHE) gamma-ray astronomy. It will be devoted
to observations in a wide band of energy, from a few tens of GeV to a few
hundreds of TeV with Large, Medium and Small-sized telescopes. The Small-Size
Telescopes (SSTs) are dedicated to the highest energy range above a few TeV and
up to 300 TeV. GCT is an imaging atmospheric Cherenkov telescope (IACT)
proposed for the subarray of about 70 SSTs to be installed on the Southern site
of CTA in Chile. The Observatory of Paris and the National Institute for Earth
Sciences and Astronomy (INSU/CNRS) have developed the mechanical structure,
mirrors (aspherical lightweight aluminium segments) and control system of the
GCT. The GCT is based on a Schwarzschild- Couder (S-C) dual-mirror optical
design which has the advantages, compared to the current IACTs, to offer a wide
field of view (~ 9{\deg}) while decreasing the cost and volume (~ 9 m x 4 m x 6
m for ~ 11 tons) of the telescope structure, as well as the camera. The
prototype (pGCT) has been installed at the Meudon's site of the Observatory of
Paris and was the first S-C telescope and the first CTA prototype to record VHE
events on-sky in November 2015. After three years of intensive testing, pGCT
has now been commissioned. This paper is a status report on the complete GCT
telescope optical system and the performance it can provide for CTA.
[2]
oai:arXiv.org:1810.08695 [pdf] - 1773582
The Maunakea Spectroscopic Explorer Book 2018
Hill, Alexis;
Flagey, Nicolas;
McConnachie, Alan;
Szeto, Kei;
Anthony, Andre;
Ariño, Javier;
Babas, Ferdinand;
Bagnoud, Gregoire;
Baker, Gabriella;
Barrick, Gregory;
Bauman, Steve;
Benedict, Tom;
Berthod, Christophe;
Bilbao, Armando;
Bizkarguenaga, Alberto;
Blin, Alexandre;
Bradley, Colin;
Brousseau, Denis;
Brown, Rebecca;
Brzeski, Jurek;
Brzezik, Walter;
Caillier, Patrick;
Campo, Ramón;
Carton, Pierre-Henri;
Chu, Jiaru;
Churilov, Vladimir;
Crampton, David;
Crofoot, Lisa;
Dale, Laurie;
de Bilbao, Lander;
de la Maza, Markel Sainz;
Devost, Daniel;
Edgar, Michael;
Erickson, Darren;
Farrell, Tony;
Fouque, Pascal;
Fournier, Paul;
Garrido, Javier;
Gedig, Mike;
Geyskens, Nicolas;
Gilbert, James;
Gillingham, Peter;
de Rivera, Guillermo González;
Green, Greg;
Grigel, Eric;
Hall, Patrick;
Ho, Kevin;
Horville, David;
Hu, Hongzhuan;
Irusta, David;
Isani, Sidik;
Jahandar, Farbod;
Kaplinghat, Manoj;
Kielty, Collin;
Kulkarni, Neelesh;
Lahidalga, Leire;
Laurent, Florence;
Lawrence, Jon;
Laychak, Mary Beth;
Lee, Jooyoung;
Liu, Zhigang;
Loewen, Nathan;
López, Fernando;
Lorentz, Thomas;
Lorgeoux, Guillaume;
Mahoney, Billy;
Mali, Slavko;
Manuel, Eric;
Martínez, Sofía;
Mazoukh, Celine;
Messaddeq, Younès;
Migniau, Jean-Emmanuel;
Mignot, Shan;
Monty, Stephanie;
Morency, Steeve;
Mouser, Yves;
Muller, Ronny;
Muller, Rolf;
Murga, Gaizka;
Murowinski, Rick;
Nicolov, Victor;
Pai, Naveen;
Pawluczyk, Rafal;
Pazder, John;
Pécontal, Arlette;
Petric, Andreea;
Prada, Francisco;
Rai, Corinne;
Ricard, Coba;
Roberts, Jennifer;
Rodgers, J. Michael;
Rodgers, Jane;
Ruan, Federico;
Russelo, Tamatea;
Salmom, Derrick;
Sánchez, Justo;
Saunders, Will;
Scott, Case;
Sheinis, Andy;
Simons, Douglas;
Smedley, Scott;
Tang, Zhen;
Teran, Jose;
Thibault, Simon;
Thirupathi, Sivarani;
Tresse, Laurence;
Troy, Mitchell;
Urrutia, Rafael;
van Vuuren, Emile;
Venkatesan, Sudharshan;
Venn, Kim;
Vermeulen, Tom;
Villaver, Eva;
Waller, Lew;
Wang, Lei;
Wang, Jianping;
Williams, Eric;
Wilson, Matt;
Withington, Kanoa;
Yèche, Christophe;
Yong, David;
Zhai, Chao;
Zhang, Kai;
Zhelem, Ross;
Zhou, Zengxiang
Submitted: 2018-10-19, last modified: 2018-10-24
(Abridged) This is the Maunakea Spectroscopic Explorer 2018 book. It is
intended as a concise reference guide to all aspects of the scientific and
technical design of MSE, for the international astronomy and engineering
communities, and related agencies. The current version is a status report of
MSE's science goals and their practical implementation, following the System
Conceptual Design Review, held in January 2018. MSE is a planned 10-m class,
wide-field, optical and near-infrared facility, designed to enable
transformative science, while filling a critical missing gap in the emerging
international network of large-scale astronomical facilities. MSE is completely
dedicated to multi-object spectroscopy of samples of between thousands and
millions of astrophysical objects. It will lead the world in this arena, due to
its unique design capabilities: it will boast a large (11.25 m) aperture and
wide (1.52 sq. degree) field of view; it will have the capabilities to observe
at a wide range of spectral resolutions, from R2500 to R40,000, with massive
multiplexing (4332 spectra per exposure, with all spectral resolutions
available at all times), and an on-target observing efficiency of more than
80%. MSE will unveil the composition and dynamics of the faint Universe and is
designed to excel at precision studies of faint astrophysical phenomena. It
will also provide critical follow-up for multi-wavelength imaging surveys, such
as those of the Large Synoptic Survey Telescope, Gaia, Euclid, the Wide Field
Infrared Survey Telescope, the Square Kilometre Array, and the Next Generation
Very Large Array.
[3]
oai:arXiv.org:1807.09180 [pdf] - 1721278
Maunakea Spectroscopic Explorer (MSE) - The Prime Focus Subsystems:
Requirements and Interfaces
Submitted: 2018-07-20
MSE will be a massively multiplexed survey telescope, including a segmented
primary mirror which feeds fibers at the prime focus, including an array of
approximately four thousand fibers, positioned precisely to feed banks of
spectrographs several tens of meters away. We describe the process of mapping
top-level requirements on MSE to technical specifications for subsystems
located at the MSE prime focus. This includes the overall top-level
requirements based on knowledge of similar systems at other telescopes and how
those requirements were converted into specifications so that the subsystems
could begin working on their Conceptual Design Phases. We then discuss the
verification of the engineering specifications and the compiling of lower-level
requirements and specifications into higher level performance budgets (e.g.
Image Quality). We also briefly discuss the interface specifications, their
effect on the performance of the system and the plan to manage them going
forward. We also discuss the opto-mechanical design of the telescope top end
assembly and refer readers to more details for instrumentation located at the
top end.
[5]
oai:arXiv.org:1207.0768 [pdf] - 1124573
Multi-Object Spectroscopy with the European ELT: Scientific synergies
between EAGLE & EVE
Evans, C. J.;
Barbuy, B.;
Bonifacio, P.;
Chemla, F.;
Cuby, J. -G.;
Dalton, G. B.;
Davies, B.;
Disseau, K.;
Dohlen, K.;
Flores, H.;
Gendron, E.;
Guinouard, I.;
Hammer, F.;
Hastings, P.;
Horville, D.;
Jagourel, P.;
Kaper, L.;
Laporte, P.;
Lee, D.;
Morris, S. L.;
Morris, T.;
Myers, R.;
Navarro, R.;
Parr-Burman, P.;
Petitjean, P.;
Puech, M.;
Rollinde, E.;
Rousset, G.;
Schnetler, H.;
Welikala, N.;
Wells, M.;
Yang, Y.
Submitted: 2012-07-03
The EAGLE and EVE Phase A studies for instruments for the European Extremely
Large Telescope (E-ELT) originated from related top-level scientific questions,
but employed different (yet complementary) methods to deliver the required
observations. We re-examine the motivations for a multi-object spectrograph
(MOS) on the E-ELT and present a unified set of requirements for a versatile
instrument. Such a MOS would exploit the excellent spatial resolution in the
near-infrared envisaged for EAGLE, combined with aspects of the spectral
coverage and large multiplex of EVE. We briefly discuss the top-level systems
which could satisfy these requirements in a single instrument at one of the
Nasmyth foci of the E-ELT.
[6]
oai:arXiv.org:1110.1944 [pdf] - 1084747
X-shooter, the new wide band intermediate resolution spectrograph at the
ESO Very Large Telescope
Vernet, Joel;
Dekker, H.;
D'Odorico, S.;
Kaper, L.;
Kjaergaard, P.;
Hammer, F.;
Randich, S.;
Zerbi, F.;
Groot, P. M.;
Hjorth, J.;
Guinouard, I.;
Navarro, R.;
Adolfse, T.;
Albers, P. W.;
Amans, J. -P.;
Andersen, J. J.;
Andersen, M. I.;
Binetruy, P.;
Bristow, P.;
Castillo, R.;
Chemla, F.;
Christensen, L.;
Conconi, P.;
Conzelmann, R.;
Dam, J.;
De Caprio, V.;
Postigo, A. De Ugarte;
Delabre, B.;
Di Marcantonio, P.;
Downing, M.;
Elswijk, E.;
Finger, G.;
Fischer, G.;
Flores, H.;
Francois, P.;
Goldoni, P.;
Guglielmi, L.;
Haigron, R.;
Hanenburg, H.;
Hendriks, I.;
Horrobin, M.;
Horville, D.;
Jessen, N. C.;
Kerber, F.;
Kern, L.;
Kiekebusch, M.;
Kleszcz, P.;
Klougart, J.;
Kragt, J.;
Larsen, H. H.;
Lizon, J. -L.;
Lucuix, C.;
Mainieri, V.;
Manuputy, R.;
Martayan, C.;
Mason, E.;
Mazzoleni, R.;
Michaelsen, N.;
Modigliani, A.;
Moehler, S.;
Møller, P.;
Sørensen, A. Norup;
Nørregaard, P.;
Peroux, C.;
Patat, F.;
Pena, E.;
Pragt, J.;
Reinero, C.;
Riga, F.;
Riva, M.;
Roelfsema, R.;
Royer, F.;
Sacco, G.;
Santin, P.;
Schoenmaker, T.;
Spano, P.;
Sweers, E.;
Ter Horst, R.;
Tintori, M.;
Tromp, N.;
van Dael, P.;
van der Vliet, H.;
Venema, L.;
Vidali, M.;
Vinther, J.;
Vola, P.;
Winters, R.;
Wistisen, D.;
Wulterkens, G.;
Zacchei, A.
Submitted: 2011-10-10
X-shooter is the first 2nd generation instrument of the ESO Very Large
Telescope(VLT). It is a very efficient, single-target, intermediate-resolution
spectrograph that was installed at the Cassegrain focus of UT2 in 2009. The
instrument covers, in a single exposure, the spectral range from 300 to 2500
nm. It is designed to maximize the sensitivity in this spectral range through
dichroic splitting in three arms with optimized optics, coatings, dispersive
elements and detectors. It operates at intermediate spectral resolution
(R~4,000 - 17,000, depending on wavelength and slit width) with fixed echelle
spectral format (prism cross-dispersers) in the three arms. It includes a
1.8"x4" Integral Field Unit as an alternative to the 11" long slits. A
dedicated data reduction package delivers fully calibrated two-dimensional and
extracted spectra over the full wavelength range. We describe the main
characteristics of the instrument and present its performance as measured
during commissioning, science verification and the first months of science
operations.
[7]
oai:arXiv.org:1009.3644 [pdf] - 1040690
GYES, a multifibre spectrograph for the CFHT
Bonifacio, P.;
Mignot, S.;
Dournaux, J. -L.;
François, P.;
Caffau, E.;
Royer, F.;
Babusiaux, C.;
Arenou, F.;
Balkowski, C.;
Bienaymé, O.;
Briot, D.;
Carlberg, R.;
Cohen, M.;
Dalton, G. B.;
Famaey, B.;
Fasola, G.;
Frémat, Y.;
Gómez, A.;
Haywood, M.;
Hill, V.;
Huet, J. -M.;
Katz, D.;
Horville, D.;
Kudritzky, R.;
Lallement, R.;
Laporte, Ph.;
de Laverny, P.;
Lemasle, B.;
Lewis, I. J.;
Martayan, C.;
Monier, R.;
Mourard, D.;
Nardetto, N.;
Blanco, . A. Recio;
Robichon, N.;
Robin, A. C.;
Rodrigues, M.;
Soubiran, C.;
Turon, C.;
Venn, K.;
Viala, Y.
Submitted: 2010-09-19
We have chosen the name of GYES, one of the mythological giants with one
hundred arms, offspring of Gaia and Uranus, for our instrument study of a
multifibre spectrograph for the prime focus of the Canada-France-Hawaii
Telescope. Such an instrument could provide an excellent ground-based
complement for the Gaia mission and a northern complement to the HERMES project
on the AAT. The CFHT is well known for providing a stable prime focus
environment, with a large field of view, which has hosted several imaging
instruments, but has never hosted a multifibre spectrograph. Building upon the
experience gained at GEPI with FLAMES-Giraffe and X-Shooter, we are
investigating the feasibility of a high multiplex spectrograph (about 500
fibres) over a field of view 1 degree in diameter. We are investigating an
instrument with resolution in the range 15000 to 30000, which should provide
accurate chemical abundances for stars down to 16th magnitude and radial
velocities, accurate to 1 km/s for fainter stars. The study is led by
GEPI-Observatoire de Paris with a contribution from Oxford for the study of the
positioner. The financing for the study comes from INSU CSAA and Observatoire
de Paris. The conceptual study will be delivered to CFHT for review by October
1st 2010.