Normalized to: Hope, S.
[1]
oai:arXiv.org:1902.00928 [pdf] - 1859992
The Apache Point Observatory Galactic Evolution Experiment (APOGEE)
Spectrographs
Wilson, J. C.;
Hearty, F. R.;
Skrutskie, M. F.;
Majewski, S. R.;
Holtzman, J. A.;
Eisenstein, D.;
Gunn, J.;
Blank, B.;
Henderson, C.;
Smee, S.;
Nelson, M.;
Nidever, D.;
Arns, J.;
Barkhouser, R.;
Barr, J.;
Beland, S.;
Bershady, M. A.;
Blanton, M. R.;
Brunner, S.;
Burton, A.;
Carey, L.;
Carr, M.;
Colque, J. P.;
Crane, J.;
Damke, G. J.;
Davidson, J. W.;
Dean, J.;
Di Mille, F.;
Don, K. W.;
Ebelke, G.;
Evans, M.;
Fitzgerald, G.;
Gillespie, B.;
Hall, M.;
Harding, A.;
Harding, P.;
Hammond, R.;
Hancock, D.;
Harrison, C.;
Hope, S.;
Horne, T.;
Karakla, J.;
Lam, C.;
Leger, F.;
MacDonald, N.;
Maseman, P.;
Matsunari, J.;
Melton, S.;
Mitcheltree, T.;
O'Brien, T.;
O'Connell, R. W.;
Patten, A.;
Richardson, W.;
Rieke, G.;
Rieke, M.;
Roman-Lopes, A.;
Schiavon, R. P.;
Sobeck, J. S.;
Stolberg, T.;
Stoll, R.;
Tembe, M.;
Trujillo, J. D.;
Uomoto, A.;
Vernieri, M.;
Walker, E.;
Weinberg, D. H.;
Young, E.;
Anthony-Brumfield, B.;
Bizyaev, D.;
Breslauer, B.;
De Lee, N.;
Downey, J.;
Halverson, S.;
Huehnerhoff, J.;
Klaene, M.;
Leon, E.;
Long, D.;
Mahadevan, S.;
Malanushenko, E.;
Nguyen, D. C.;
Owen, R.;
Sanchez-Gallego, J. R.;
Sayres, C.;
Shane, N.;
Shectman, S. A.;
Shetrone, M.;
Skinner, D.;
Stauffer, F.;
Zhao, B.
Submitted: 2019-02-03
We describe the design and performance of the near-infrared (1.51--1.70
micron), fiber-fed, multi-object (300 fibers), high resolution (R =
lambda/delta lambda ~ 22,500) spectrograph built for the Apache Point
Observatory Galactic Evolution Experiment (APOGEE). APOGEE is a survey of ~
10^5 red giant stars that systematically sampled all Milky Way populations
(bulge, disk, and halo) to study the Galaxy's chemical and kinematical history.
It was part of the Sloan Digital Sky Survey III (SDSS-III) from 2011 -- 2014
using the 2.5 m Sloan Foundation Telescope at Apache Point Observatory, New
Mexico. The APOGEE-2 survey is now using the spectrograph as part of SDSS-IV,
as well as a second spectrograph, a close copy of the first, operating at the
2.5 m du Pont Telescope at Las Campanas Observatory in Chile. Although several
fiber-fed, multi-object, high resolution spectrographs have been built for
visual wavelength spectroscopy, the APOGEE spectrograph is one of the first
such instruments built for observations in the near-infrared. The instrument's
successful development was enabled by several key innovations, including a
"gang connector" to allow simultaneous connections of 300 fibers; hermetically
sealed feedthroughs to allow fibers to pass through the cryostat wall
continuously; the first cryogenically deployed mosaic volume phase holographic
grating; and a large refractive camera that includes mono-crystalline silicon
and fused silica elements with diameters as large as ~ 400 mm. This paper
contains a comprehensive description of all aspects of the instrument including
the fiber system, optics and opto-mechanics, detector arrays, mechanics and
cryogenics, instrument control, calibration system, optical performance and
stability, lessons learned, and design changes for the second instrument.
[2]
oai:arXiv.org:1608.01196 [pdf] - 1531178
Visible camera cryostat design and performance for the SuMIRe Prime
Focus Spectrograph (PFS)
Smee, Stephen A.;
Gunn, James E.;
Golebiowski, Mirek;
Hope, Stephen C.;
Madec, Fabrice;
Gabriel, Jean-Francois;
Loomis, Craig;
Fur, Arnaud Le;
Dohlen, Kjetil;
Mignant, David Le;
Barkhouser, Robert;
Carr, Michael;
Hart, Murdock;
Tamura, Naoyuki;
Shimono, Atsushi;
Takato, Naruhisa
Submitted: 2016-08-03
We describe the design and performance of the SuMIRe Prime Focus Spectrograph
(PFS) visible camera cryostats. SuMIRe PFS is a massively multi-plexed
ground-based spectrograph consisting of four identical spectrograph modules,
each receiving roughly 600 fibers from a 2394 fiber robotic positioner at the
prime focus. Each spectrograph module has three channels covering wavelength
ranges 380~nm -- 640~nm, 640~nm -- 955~nm, and 955~nm -- 1.26~um, with the
dispersed light being imaged in each channel by a f/1.07 vacuum Schmidt camera.
The cameras are very large, having a clear aperture of 300~mm at the entrance
window, and a mass of $\sim$280~kg. In this paper we describe the design of the
visible camera cryostats and discuss various aspects of cryostat performance.
[3]
oai:arXiv.org:1608.01075 [pdf] - 1531175
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview,
recent progress, and future perspectives
Tamura, Naoyuki;
Takato, Naruhisa;
Shimono, Atsushi;
Moritani, Yuki;
Yabe, Kiyoto;
Ishizuka, Yuki;
Ueda, Akitoshi;
Kamata, Yukiko;
Aghazarian, Hrand;
Arnouts, Stephane;
Barban, Gabriel;
Barkhouser, Robert H.;
Borges, Renato C.;
Braun, David F.;
Carr, Michael A.;
Chabaud, Pierre-Yves;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chiba, Masashi;
Chou, Richard C. Y.;
Chu, You-Hua;
Cohen, Judith G.;
de Almeida, Rodrigo P.;
de Oliveira, Antonio C.;
de Oliveira, Ligia S.;
Dekany, Richard G.;
Dohlen, Kjetil;
Santos, Jesulino B. dos;
Santos, Leandro H. dos;
Ellis, Richard S.;
Fabricius, Maximilian;
Ferrand, Didier;
Ferreira, Decio;
Golebiowski, Mirek;
Greene, Jenny E.;
Gross, Johannes;
Gunn, James E.;
Hammond, Randolph;
Harding, Albert;
Hart, Murdock;
Heckman, Timothy M.;
Hirata, Christopher M.;
Ho, Paul;
Hope, Stephen C.;
Hovland, Larry;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Ping-Jie;
Jaquet, Marc;
Jing, Yipeng;
Karr, Jennifer;
Kimura, Masahiko;
King, Matthew E.;
Komatsu, Eiichiro;
Brun, Vincent Le;
Fevre, Olivier Le;
Fur, Arnaud Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig P.;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas S.;
de Oliveira, Claudia Mendes;
Minowa, Yosuke;
Morantz, Chaz N.;
Murayama, Hitoshi;
Murray, Graham J.;
Ohyama, Youichi;
Orndorff, Joseph;
Pascal, Sandrine;
Pereira, Jefferson M.;
Reiley, Daniel J.;
Reinecke, Martin;
Ritter, Andreas;
Roberts, Mitsuko;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Sodre, Laerte;
Spergel, David N.;
Steinkraus, Aaron J.;
Strauss, Michael A.;
Surace, Christian;
Suto, Yasushi;
Suzuki, Nao;
Swinbank, John;
Tait, Philip J.;
Takada, Masahiro;
Tamura, Tomonori;
Tanaka, Yoko;
Tresse, Laurence;
Verducci, Orlando;
Vibert, Didier;
Vidal, Clement;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Yan, Chi-Hung;
Yasuda, Naoki
Submitted: 2016-08-03
PFS (Prime Focus Spectrograph), a next generation facility instrument on the
8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed,
optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394
reconfigurable fibers will be distributed over the 1.3 deg field of view. The
spectrograph has been designed with 3 arms of blue, red, and near-infrared
cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure
at a resolution of ~1.6-2.7A. An international collaboration is developing this
instrument under the initiative of Kavli IPMU. The project is now going into
the construction phase aiming at undertaking system integration in 2017-2018
and subsequently carrying out engineering operations in 2018-2019. This article
gives an overview of the instrument, current project status and future paths
forward.
[4]
oai:arXiv.org:1507.00725 [pdf] - 1241387
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed
optical and near-infrared fiber spectrograph
Sugai, Hajime;
Tamura, Naoyuki;
Karoji, Hiroshi;
Shimono, Atsushi;
Takato, Naruhisa;
Kimura, Masahiko;
Ohyama, Youichi;
Ueda, Akitoshi;
Aghazarian, Hrand;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Bozier, Alexandre;
Braun, David F.;
Bui, Khanh;
Capocasale, Christopher M.;
Carr, Michael A.;
Castilho, Bruno;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chou, Richard C. Y.;
Dawson, Olivia R.;
Dekany, Richard G.;
Ek, Eric M.;
Ellis, Richard S.;
English, Robin J.;
Ferrand, Didier;
Ferreira, Décio;
Fisher, Charles D.;
Golebiowski, Mirek;
Gunn, James E.;
Hart, Murdock;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hope, Stephen;
Hovland, Larry E.;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Pin Jie;
Jaquet, Marc;
Karr, Jennifer E.;
Kempenaar, Jason G.;
King, Matthew E.;
Fèvre, Olivier Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas Souza;
Ménard, Brice;
Morantz, Chaz;
Murayama, Hitoshi;
Murray, Graham J.;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Partos, Eamon J.;
Pascal, Sandrine;
Pegot-Ogier, Thomas;
Reiley, Daniel J.;
Riddle, Reed;
Santos, Leandro;
Santos, Jesulino Bispo dos;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Steinkraus, Ronald E.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Tresse, Laurence;
Vidal, Clément;
Vives, Sebastien;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Wu, Amy C.;
Wyse, Rosie;
Yan, Chi-Hung
Submitted: 2015-07-02
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber
spectrograph with 2394 science fibers distributed across a 1.3-deg diameter
field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from
0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously
strengthens its ability to target three main survey programs: cosmology,
galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a
resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available
by simply exchanging dispersers. We highlight some of the technological aspects
of the design. To transform the telescope focal ratio, a broad-band coated
microlens is glued to each fiber tip. A higher transmission fiber is selected
for the longest part of the cable system, optimizing overall throughput; a
fiber with low focal ratio degradation is selected for the fiber-positioner and
fiber-slit components, minimizing the effects of fiber movements and fiber
bending. Fiber positioning will be performed by a positioner consisting of two
stages of piezo-electric rotary motors. The positions of these motors are
measured by taking an image of artificially back-illuminated fibers with the
metrology camera located in the Cassegrain container; the fibers are placed in
the proper location by iteratively measuring and then adjusting the positions
of the motors. Target light reaches one of the four identical fast-Schmidt
spectrograph modules, each with three arms. The PFS project has passed several
project-wide design reviews and is now in the construction phase.
[5]
oai:arXiv.org:1408.3401 [pdf] - 1216308
CCD Readout Electronics for the Subaru Prime Focus Spectrograph
Submitted: 2014-08-14
We present details of the design for the CCD readout electronics for the
Subaru Telescope Prime Focus Spectrograph (PFS). The spectrograph is comprised
of four identical spectrograph modules, each collecting roughly 600 spectra.
The spectrograph modules provide simultaneous wavelength coverage over the
entire band from 380 nm to 1260 nm through the use of three separate optical
channels: blue, red, and near infrared (NIR). A camera in each channel images
the multi-object spectra onto a 4k x 4k, 15 um pixel, detector format. The two
visible cameras use a pair of Hamamatsu 2k x 4k CCDs with readout provided by
custom electronics, while the NIR camera uses a single Teledyne HgCdTe 4k x 4k
detector and ASIC Sidecar to read the device.
The CCD readout system is a custom design comprised of three electrical
subsystems: the Back End Electronics (BEE), the Front End Electronics (FEE),
and a Pre-amplifier. The BEE is an off-the-shelf PC104 computer, with an
auxiliary Xilinx FPGA module. The computer serves as the main interface to the
Subaru messaging hub and controls other peripheral devices associated with the
camera, while the FPGA is used to generate the necessary clocks and transfer
image data from the CCDs. The FEE board sets clock biases, substrate bias, and
CDS offsets. It also monitors bias voltages, offset voltages, power rail
voltage, substrate voltage and CCD temperature. The board translates LVDS clock
signals to biased clocks and returns digitized analog data via LVDS. Monitoring
and control messages are sent from the BEE to the FEE using a standard serial
interface. The Pre-amplifier board resides behind the detectors and acts as an
interface to the two Hamamatsu CCDs. The Pre-amplifier passes clocks and biases
to the CCDs, and analog CCD data is buffered and amplified prior to being
returned to the FEE.
[6]
oai:arXiv.org:1408.2822 [pdf] - 1216259
Focal Plane Alignment and Detector Characterization for the Subaru Prime
Focus Spectrograph
Submitted: 2014-08-12
We describe the infrastructure being developed to align and characterize the
detectors for the Subaru Measurement of Images and Redshifts (SuMIRe) Prime
Focus Spectrograph (PFS). PFS will employ four three-channel spectrographs with
an operating wavelength range of 3800 $\AA$ to 12600 $\AA$. Each spectrograph
will be comprised of two visible channels and one near infrared (NIR) channel,
where each channel will use a separate Schmidt camera to image the captured
spectra onto their respective detectors. In the visible channels, Hamamatsu 2k
x 4k CCDs will be mounted in pairs to create a single 4k x 4k detector, while
the NIR channel will use a single Teledyne 4k x 4k H4RG HgCdTe device.
[7]
oai:arXiv.org:1408.3284 [pdf] - 1216305
The near infrared camera for the Subaru Prime Focus Spectrograph
Smee, Stephen A.;
Gunn, James E.;
Golebiowski, Mirek;
Barkhouser, Robert;
Vives, Sebastien;
Pascal, Sandrine;
Carr, Michael;
Hope, Stephen C.;
Loomis, Craig;
Hart, Murdock;
Sugai, Hajime;
Tamura, Naoyuki;
Shimono, Atsushi
Submitted: 2014-08-12
We present the detailed design of the near infrared camera for the SuMIRe
(Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS)
being developed for the Subaru Telescope. The PFS spectrograph is designed to
collect spectra from 2394 objects simultaneously, covering wavelengths that
extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical
spectrograph modules, with each module collecting roughly 600 spectra from a
robotic fiber positioner at the telescope prime focus. Each spectrograph module
will have two visible channels covering wavelength ranges 380 nm - 640 nm and
640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range
955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal
length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector
format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff
device is used. In the visible channels, CCDs from Hamamatsu are used. These
cameras are large, having a clear aperture of 300 mm at the entrance window,
and a mass of ~ 250 kg.
Like the two visible channel cameras, the NIR camera contains just four
optical elements: a two-element refractive corrector, a Mangin mirror, and a
field flattening lens. This simple design produces very good imaging
performance considering the wide field and wavelength range, and it does so in
large part due to the use of a Mangin mirror (a lens with a reflecting rear
surface) for the Schmidt primary. In the case of the NIR camera, the rear
reflecting surface is a dichroic, which reflects in-band wavelengths and
transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection
filter coating on the rear surface of the second corrector element, greatly
reduces the out-of-band thermal radiation that reaches the detector.
[8]
oai:arXiv.org:1408.2827 [pdf] - 1216261
Current status of the Spectrograph System for the SuMIRe/PFS
Vives, S.;
Mignant, D. Le;
Gunn, J. E.;
Smee, S.;
de Oliveira, L. Souza;
Tamura, N.;
Sugai, H.;
Barkhouser, R.;
Bozier, A.;
Carr, M. A.;
de Oliveira, A. Cesar;
Ferrand, D.;
Golebiowski, M.;
Hart, M.;
Hope, S.;
Jaquet, M.;
Madec, F.;
Pascal, S.;
Pegot-Ogier, T.;
de Arruda, M. Vittal
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is a new facility instrument for Subaru
Telescope which will be installed in around 2017. It is a multi-object
spectrograph fed by about 2400 fibers placed at the prime focus covering a
hexagonal field-of-view with 1.35 deg diagonals and capable of simultaneously
obtaining data of spectra with wavelengths ranging from 0.38 um to 1.26 um. The
spectrograph system is composed of four identical modules each receiving the
light from 600 fibers. Each module incorporates three channels covering the
wavelength ranges 0.38-0.65 mu ("Blue"), 0.63-0.97 mu ("Red"), and 0.94-1.26 mu
("NIR") respectively; with resolving power which progresses fairly smoothly
from about 2000 in the blue to about 4000 in the infrared. An additional
spectral mode allows reaching a spectral resolution of 5000 at 0.8mu (red). The
proposed optical design is based on a Schmidt collimator facing three Schmidt
cameras (one per spectral channel). This architecture is very robust, well
known and documented. It allows for high image quality with only few simple
elements (high throughput) at the expense of the central obscuration, which
leads to larger optics. Each module has to be modular in its design to allow
for integration and tests and for its safe transport up to the telescope: this
is the main driver for the mechanical design. In particular, each module will
be firstly fully integrated and validated at LAM (France) before it is shipped
to Hawaii. All sub-assemblies will be indexed on the bench to allow for their
accurate repositioning. This paper will give an overview of the spectrograph
system which has successfully passed the Critical Design Review (CDR) in 2014
March and which is now in the construction phase.
[9]
oai:arXiv.org:1408.2825 [pdf] - 1216260
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a
massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime;
Tamura, Naoyuki;
Karoji, Hiroshi;
Shimono, Atsushi;
Takato, Naruhisa;
Kimura, Masahiko;
Ohyama, Youichi;
Ueda, Akitoshi;
Aghazarian, Hrand;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Bozier, Alexandre;
Braun, David F.;
Bui, Khanh;
Capocasale, Christopher M.;
Carr, Michael A.;
Castilho, Bruno;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chou, Richard C. Y.;
Dawson, Olivia R.;
Dekany, Richard G.;
Ek, Eric M.;
Ellis, Richard S.;
English, Robin J.;
Ferrand, Didier;
Ferreira, Décio;
Fisher, Charles D.;
Golebiowski, Mirek;
Gunn, James E.;
Hart, Murdock;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hope, Stephen;
Hovland, Larry E.;
Hsuc, Shu-Fu;
Hu, Yen-Shan;
Huang, Pin Jie;
Jaquet, Marc;
Karr, Jennifer E.;
Kempenaar, Jason G.;
King, Matthew E.;
Fèvre, Olivier Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas Souza;
Ménard, Brice;
Morantz, Chaz;
Murayama, Hitoshi;
Murray, Graham J.;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Partos, Eamon J.;
Pascal, Sandrine;
Pegot-Ogier, Thomas;
Reiley, Daniel J.;
Riddle, Reed;
Santos, Leandro;
Santos, Jesulino Bispo dos;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Steinkraus, Ronald E.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Tresse, Laurence;
Vidal, Clément;
Vives, Sebastien;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Wu, Amy C.;
Wyse, Rosie;
Yan, Chi-Hung
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber
spectrograph with 2394 science fibers, which are distributed in 1.3 degree
diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide
wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000,
strengthens its ability to target three main survey programs: cosmology,
Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with
resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply
exchanging dispersers. PFS takes the role for the spectroscopic part of the
Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam
works on the imaging part. To transform the telescope plus WFC focal ratio, a
3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip.
A higher transmission fiber is selected for the longest part of cable system,
while one with a better FRD performance is selected for the fiber-positioner
and fiber-slit components, given the more frequent fiber movements and tightly
curved structure. Each Fiber positioner consists of two stages of
piezo-electric rotary motors. Its engineering model has been produced and
tested. Fiber positioning will be performed iteratively by taking an image of
artificially back-illuminated fibers with the Metrology camera located in the
Cassegrain container. The camera is carefully designed so that fiber position
measurements are unaffected by small amounts of high special-frequency
inaccuracies in WFC lens surface shapes. Target light carried through the fiber
system reaches one of four identical fast-Schmidt spectrograph modules, each
with three arms. Prototype VPH gratings have been optically tested. CCD
production is complete, with standard fully-depleted CCDs for red arms and
more-challenging thinner fully-depleted CCDs with blue-optimized coating for
blue arms.