Normalized to: Honda, D.
[1]
oai:arXiv.org:1709.08829 [pdf] - 1670475
In-orbit performance of the soft X-ray imaging system aboard Hitomi
(ASTRO-H)
Nakajima, H.;
Maeda, Y.;
Uchida, H.;
Tanaka, T.;
Tsunemi, H.;
Hayashida, K.;
Tsuru, T. G.;
Dotani, T.;
Nagino, R.;
Inoue, S.;
Ozaki, M.;
Tomida, H.;
Natsukari, C.;
Ueda, S.;
Mori, K.;
Yamauchi, M.;
Hatsukade, I.;
Nishioka, Y.;
Sakata, M.;
Beppu, T.;
Honda, D.;
Nobukawa, M.;
Hiraga, J. S.;
Kohmura, T.;
Murakami, H.;
Nobukawa, K. K.;
Bamba, A.;
Doty, J. P.;
Iizuka, R.;
Sato, T.;
Kurashima, S.;
Nakaniwa, N.;
Asai, R.;
Ishida, M.;
Mori, H.;
Soong, Y.;
Okajima, T.;
Serlemitsos, P.;
Tawara, Y.;
Mitsuishi, I.;
Ishibashi, K.;
Tamura, K.;
Hayashi, T.;
Furuzawa, A.;
Sugita, S.;
Miyazawa, T.;
Awaki, H.;
Miller, E. D.;
Yamaguchi, H.
Submitted: 2017-09-26
We describe the in-orbit performance of the soft X-ray imaging system
consisting of the Soft X-ray Telescope and the Soft X-ray Imager aboard Hitomi.
Verification and calibration of imaging and spectroscopic performance are
carried out making the best use of the limited data of less than three weeks.
Basic performance including a large field of view of 38'x38' is verified with
the first light image of the Perseus cluster of galaxies. Amongst the small
number of observed targets, the on-minus-off pulse image for the out-of-time
events of the Crab pulsar enables us to measure a half power diameter of the
telescope as about 1.3'. The average energy resolution measured with the
onboard calibration source events at 5.89 keV is 179 pm 3 eV in full width at
half maximum. Light leak and cross talk issues affected the effective exposure
time and the effective area, respectively, because all the observations were
performed before optimizing an observation schedule and parameters for the dark
level calculation. Screening the data affected by these two issues, we measure
the background level to be 5.6x10^{-6} counts s^{-1} arcmin^{-2} cm^{-2} in the
energy band of 5-12 keV, which is seven times lower than that of the Suzaku
XIS-BI.