Hollingworth, R.
Normalized to: Hollingworth, R.
2 article(s) in total. 63 co-authors, from 1 to 3 common article(s). Median position in authors list is 18,0.
[1]
oai:arXiv.org:astro-ph/0605500 [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and
commissioning
Akimov, D. Yu.;
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Burenkov, A. A.;
Carson, M. J.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Chag, C.;
Hollingworth, R. J.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Kuznetsov, I. S.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G. G.;
Paling, S. M.;
Muna, D.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F.
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.
[2]
oai:arXiv.org:astro-ph/0603243 [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an
end-to-end simulation tool
Araujo, H. M.;
Akimov, D. Yu.;
Alner, G. J.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Chepel, V.;
Chagani, H.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Ghag, C.;
Hollingworth, R.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Lebedenko, V. N.;
Lawson, T.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K.;
McMillan, J.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G.;
Paling, S.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Tovey, D. R.;
Thorne, C.;
Tziaferi, E.;
Walker, R. J.
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.