sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Hollingworth, R.

Normalized to: Hollingworth, R.

2 article(s) in total. 63 co-authors, from 1 to 3 common article(s). Median position in authors list is 18,0.

[1]  oai:arXiv.org:astro-ph/0605500  [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
Comments: 25 pages, 19 figures. Submitted to Astropart. Phys. Some figures down sampled to reduce size
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.
[2]  oai:arXiv.org:astro-ph/0603243  [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
Comments: Submitted to Astroparticle Physics
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.