Normalized to: Holdenried, E.
[1]
oai:arXiv.org:1605.09780 [pdf] - 1415310
W1J00 and W2J00: Results of the Observations made with the Six-inch
Transit Circle 1977-1982 AND Results of Pole-to-Pole Observations made with
the Six-inch and Seven-inch Transit Circles 1985-1996
Submitted: 2016-05-31
The astronomical results contained in this publication represent a
continuation of previous work of the United States Naval Observatory Six-inch
and Seven-inch transit circles. The results are also the last from United
States Naval Observatory transit circles, since those instruments are no longer
in service.
For the W1J00, we present the results of observations made with the Six-inch
Transit Circle in Washington, D.C., between September 1977 and July 1982. The
catalog, called W1J00, contains mean positions of 7267 stars, all but five are
north of -30 degrees declination, and 4383 observations of solar system
objects. Positions of stars are for mean epoch of observation, on equator and
equinox J2000.0. Positions of solar system objects are apparent places. Error
estimates are about 100 mas per coordinate for the majority of stars.
For the W2J00, we present the results of observations made with the Six-inch
Transit Circle in Washington, D.C. and the Seven-inch Transit Circle at the
Black Birch station near Blenheim, New Zealand between April 1985 and February
1996. The catalog, called W2J00, contains mean positions of 44,395 globally
distributed stars, 5048 observations of the planets, and 6518 observations of
the brighter minor planets. Positions of stars are for mean epoch of
observation, on equator and equinox J2000.0. Positions of solar system objects
are apparent places. Error estimates are about 75 mas per coordinate for the
majority of stars.
[2]
oai:arXiv.org:1003.2136 [pdf] - 1025634
The Third US Naval Observatory CCD Astrograph Catalog (UCAC3)
Zacharias, N.;
Finch, C.;
Girard, T.;
Hambly, N.;
Wycoff, G.;
Zacharias, M.;
Castillo, D.;
Corbin, T.;
DiVittorio, M.;
Dutta, S.;
Gaume, R.;
Gauss, S.;
Germain, M.;
Hall, D.;
Hartkopf, W.;
Hsu, D.;
Holdenried, E.;
Makarov, V.;
Martines, M.;
Mason, B.;
Monet, D.;
Rafferty, T.;
Rhodes, A.;
Siemers, T.;
Smith, D.;
Tilleman, T.;
Urban, S.;
Wieder, G.;
Winter, L.;
Young, A.
Submitted: 2010-03-09
The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3 was
released at the IAU General Assembly on 2009 August 10. It is the first all-sky
release in this series and contains just over 100 million objects, about 95
million of them with proper motions, covering about R = 8 to 16 magnitudes.
Current epoch positions are obtained from the observations with the 20 cm
aperture USNO Astrograph's "red lens", equipped with a 4k by 4k CCD. Proper
motions are derived by combining these observations with over 140 ground- and
space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as
unpublished measures of over 5000 plates from other astrographs. For most of
the faint stars in the Southern Hemisphere the Yale/San Juan first epoch plates
from the SPM program (YSJ1) form the basis for proper motions. These data are
supplemented by all-sky Schmidt plate survey astrometry and photometry obtained
from the SuperCOSMOS project, as well as 2MASS near-IR photometry. Major
differences of UCAC3 data as compared to UCAC2 include a completely new raw
data reduction with improved control over systematic errors in positions,
significantly improved photometry, slightly deeper limiting magnitude, coverage
of the north pole region, greater completeness by inclusion of double stars and
weak detections. This of course leads to a catalog which is not as "clean" as
UCAC2 and problem areas are outlined for the user in this paper. The positional
accuracy of stars in UCAC3 is about 15 to 100 mas per coordinate, depending on
magnitude, while the errors in proper motions range from 1 to 10 mas/yr
depending on magnitude and observing history, with a significant improvement
over UCAC2 achieved due to the re-reduced SPM data and inclusion of more
astrograph plate data unavailable at the time of UCAC2.
[3]
oai:arXiv.org:0806.0256 [pdf] - 13141
The StarScan plate measuring machine: overview and calibrations
Submitted: 2008-06-02
The StarScan machine at the U.S. Naval Observatory (USNO) completed measuring
photographic astrograph plates to allow determination of proper motions for the
USNO CCD Astrograph Catalog (UCAC) program. All applicable 1940 AGK2 plates,
about 2200 Hamburg Zone Astrograph plates, 900 Black Birch (USNO Twin
Astrograph) plates, and 300 Lick Astrograph plates have been measured. StarScan
comprises of a CCD camera, telecentric lens, air-bearing granite table, stepper
motor screws, and Heidenhain scales to operate in a step-stare mode. The
repeatability of StarScan measures is about 0.2 micrometer. The CCD mapping as
well as the global table coordinate system has been calibrated using a special
dot calibration plate and the overall accuracy of StarScan x,y data is derived
to be 0.5 micrometer. Application to real photographic plate data shows that
position information of at least 0.65 micrometer accuracy can be extracted from
course grain 103a-type emulsion astrometric plates. Transformations between
"direct" and "reverse" measures of fine grain emulsion plate measures are
obtained on the 0.3 micrometer level per well exposed stellar image and
coordinate, which is at the limit of the StarScan machine.