Normalized to: Holdaway, M.
[1]
oai:arXiv.org:1504.04877 [pdf] - 1488850
An Overview of the 2014 ALMA Long Baseline Campaign
Partnership, ALMA;
Fomalont, E. B.;
Vlahakis, C.;
Corder, S.;
Remijan, A.;
Barkats, D.;
Lucas, R.;
Hunter, T. R.;
Brogan, C. L.;
Asaki, Y.;
Matsushita, S.;
Dent, W. R. F.;
Hills, R. E.;
Phillips, N.;
Richards, A. M. S.;
Cox, P.;
Amestica, R.;
Broguiere, D.;
Cotton, W.;
Hales, A. S.;
Hiriart, R.;
Hirota, A.;
Hodge, J. A.;
Impellizzeri, C. M. V.;
Kern, J.;
Kneissl, R.;
Liuzzo, E.;
Marcelino, N.;
Marson, R.;
Mignano, A.;
Nakanishi, K.;
Nikolic, B.;
Perez, J. E.;
Pérez, L. M.;
Toledo, I.;
Aladro, R.;
Butler, B.;
Cortes, J.;
Cortes, P.;
Dhawan, V.;
Di Francesco, J.;
Espada, D.;
Galarza, F.;
Garcia-Appadoo, D.;
Guzman-Ramirez, L.;
Humphreys, E. M.;
Jung, T.;
Kameno, S.;
Laing, R. A.;
Leon, S.;
Mangum, J.;
Marconi, G.;
Nagai, H.;
Nyman, L. -A.;
Radiszcz, M.;
Rodón, J. A.;
Sawada, T.;
Takahashi, S.;
Tilanus, R. P. J.;
van Kempen, T.;
Vilaro, B. Vila;
Watson, L. C.;
Wiklind, T.;
Gueth, F.;
Tatematsu, K.;
Wootten, A.;
Castro-Carrizo, A.;
Chapillon, E.;
Dumas, G.;
de Gregorio-Monsalvo, I.;
Francke, H.;
Gallardo, J.;
Garcia, J.;
Gonzalez, S.;
Hibbard, J. E.;
Hill, T.;
Kaminski, T.;
Karim, A.;
Krips, M.;
Kurono, Y.;
Lopez, C.;
Martin, S.;
Maud, L.;
Morales, F.;
Pietu, V.;
Plarre, K.;
Schieven, G.;
Testi, L.;
Videla, L.;
Villard, E.;
Whyborn, N.;
Zwaan, M. A.;
Alves, F.;
Andreani, P.;
Avison, A.;
Barta, M.;
Bedosti, F.;
Bendo, G. J.;
Bertoldi, F.;
Bethermin, M.;
Biggs, A.;
Boissier, J.;
Brand, J.;
Burkutean, S.;
Casasola, V.;
Conway, J.;
Cortese, L.;
Dabrowski, B.;
Davis, T. A.;
Trigo, M. Diaz;
Fontani, F.;
Franco-Hernandez, R.;
Fuller, G.;
Madrid, R. Galvan;
Giannetti, A.;
Ginsburg, A.;
Graves, S. F.;
Hatziminaoglou, E.;
Hogerheijde, M.;
Jachym, P.;
Serra, I. Jimenez;
Karlicky, M.;
Klaasen, P.;
Kraus, M.;
Kunneriath, D.;
Lagos, C.;
Longmore, S.;
Leurini, S.;
Maercker, M.;
Magnelli, B.;
Vidal, I. Marti;
Massardi, M.;
Maury, A.;
Muehle, S.;
Muller, S.;
Muxlow, T.;
O'Gorman, E.;
Paladino, R.;
Petry, D.;
Pineda, J.;
Randall, S.;
Richer, J. S.;
Rossetti, A.;
Rushton, A.;
Rygl, K.;
Monge, A. Sanchez;
Schaaf, R.;
Schilke, P.;
Stanke, T.;
Schmalzl, M.;
Stoehr, F.;
Urban, S.;
van Kampen, E.;
Vlemmings, W.;
Wang, K.;
Wild, W.;
Yang, Y.;
Iguchi, S.;
Hasegawa, T.;
Saito, M.;
Inatani, J.;
Mizuno, N.;
Asayama, S.;
Kosugi, G.;
Morita, K. -I.;
Chiba, K.;
Kawashima, S.;
Okumura, S. K.;
Ohashi, N.;
Ogasawara, R.;
Sakamoto, S.;
Noguchi, T.;
Huang, Y. -D.;
Liu, S. -Y.;
Kemper, F.;
Koch, P. M.;
Chen, M. -T.;
Chikada, Y.;
Hiramatsu, M.;
Iono, D.;
Shimojo, M.;
Komugi, S.;
Kim, J.;
Lyo, A. -R.;
Muller, E.;
Herrera, C.;
Miura, R. E.;
Ueda, J.;
Chibueze, J.;
Su, Y. -N.;
Trejo-Cruz, A.;
Wang, K. -S.;
Kiuchi, H.;
Ukita, N.;
Sugimoto, M.;
Kawabe, R.;
Hayashi, M.;
Miyama, S.;
Ho, P. T. P.;
Kaifu, N.;
Ishiguro, M.;
Beasley, A. J.;
Bhatnagar, S.;
Braatz, J. A.;
Brisbin, D. G.;
Brunetti, N.;
Carilli, C.;
Crossley, J. H.;
D'Addario, L.;
Meyer, J. L. Donovan;
Emerson, D. T.;
Evans, A. S.;
Fisher, P.;
Golap, K.;
Griffith, D. M.;
Hale, A. E.;
Halstead, D.;
Hardy, E. J.;
Hatz, M. C.;
Holdaway, M.;
Indebetouw, R.;
Jewell, P. R.;
Kepley, A. A.;
Kim, D. -C.;
Lacy, M. D.;
Leroy, A. K.;
Liszt, H. S.;
Lonsdale, C. J.;
Matthews, B.;
McKinnon, M.;
Mason, B. S.;
Moellenbrock, G.;
Moullet, A.;
Myers, S. T.;
Ott, J.;
Peck, A. B.;
Pisano, J.;
Radford, S. J. E.;
Randolph, W. T.;
Venkata, U. Rao;
Rawlings, M. G.;
Rosen, R.;
Schnee, S. L.;
Scott, K. S.;
Sharp, N. K.;
Sheth, K.;
Simon, R. S.;
Tsutsumi, T.;
Wood, S. J.
Submitted: 2015-04-19, last modified: 2015-04-24
A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to
make accurate images with resolutions of tens of milliarcseconds, which at
submillimeter (submm) wavelengths requires baselines up to ~15 km. To develop
and test this capability, a Long Baseline Campaign (LBC) was carried out from
September to late November 2014, culminating in end-to-end observations,
calibrations, and imaging of selected Science Verification (SV) targets. This
paper presents an overview of the campaign and its main results, including an
investigation of the short-term coherence properties and systematic phase
errors over the long baselines at the ALMA site, a summary of the SV targets
and observations, and recommendations for science observing strategies at long
baselines. Deep ALMA images of the quasar 3C138 at 97 and 241 GHz are also
compared to VLA 43 GHz results, demonstrating an agreement at a level of a few
percent. As a result of the extensive program of LBC testing, the highly
successful SV imaging at long baselines achieved angular resolutions as fine as
19 mas at ~350 GHz. Observing with ALMA on baselines of up to 15 km is now
possible, and opens up new parameter space for submm astronomy.
[2]
oai:arXiv.org:astro-ph/0609329 [pdf] - 84921
Evaluation of the ALMA Prototype Antennas
Submitted: 2006-09-12
The ALMA North American and European prototype antennas have been evaluated
by a variety of measurement systems to quantify the major performance
specifications. Nearfield holography was used to set the reflector surfaces to
17 microns RMS. Pointing and fast switching performance was determined with an
optical telescope and by millimeter wavelength radiometry, yielding 2 arcsec
absolute and 0.6 arcsec offset pointing accuracies. Path length stability was
measured to be less than or approximately equal to 20 microns over 10 minute
time periods using optical measurement devices. Dynamical performance was
studied with a set of accelerometers, providing data on wind induced tracking
errors and structural deformation. Considering all measurements made during
this evaluation, both prototype antennas meet the major ALMA antenna
performance specifications.
[3]
oai:arXiv.org:astro-ph/0511117 [pdf] - 77475
Quasars in the MAMBO blank field survey
Submitted: 2005-11-03
Our MAMBO 1.2 mm blank field imaging survey of ~0.75 sqd has uncovered four
unusually bright sources, with flux densities between 10 and 90 mJy, all
located in the Abell 2125 field. The three brightest are flat spectrum radio
sources with bright optical and X-ray counterparts. Their mm and radio flux
densities are variable on timescales of months. Their X-ray luminosities
classify them as quasars. The faintest of the four mm bright sources appears to
be a bright, radio-quiet starburst at z~3, similar to the sources seen at lower
flux densities in the MAMBO and SCUBA surveys. It may also host a mildly
obscured AGN of quasar-like X-ray luminosity. The three non-thermal mm sources
imply an areal density of flat spectrum radio sources higher by at least 7
compared with that expected from an extrapolation of the lower frequency radio
number counts.
[4]
oai:arXiv.org:astro-ph/0310655 [pdf] - 1233254
New high-resolution radio observations of the SNR CTB 80
Submitted: 2003-10-22
We report new high resolution and high sensitivity radio observations of the
extended supernova remnant (SNR) CTB 80 (G69.0+2.7) at 240 MHz, 324 MHz, 618
MHz, and 1380 MHz. The imaging of CTB 80 at 240 MHz and 618 MHz was performed
using the Giant Metrewave Radio Telescope (GMRT) in India. The observations at
324 MHz and 1380 MHz were obtained using the Very Large Array (VLA, NRAO) in
its C and D configurations. The new radio images reveal faint extensions for
the asymmetric arms of CTB 80. The arms are irregular with filaments and clumps
of size 1' (or 0.6 pc at a distance of 2 kpc). The radio image at 1380 MHz is
compared with IR and optical emission. The correspondence IR/radio is excellent
along the N arm of CTB 80. Ionized gas observed in the [SII] line perfectly
matches the W and N edges of CTB 80. The central nebula associated with the
pulsar PSR B1951+32 was investigated with an angular resolution of 10" x 6".
The new radio image obtained at 618 MHz shows with superb detail structures in
the 8' x 4' E-W ``plateau'' nebula that hosts the pulsar on its western
extreme. A twisted filament, about 6' in extent (~3.5 pc), trails behind the
pulsar in an approximate W-E direction. In the bright ``core'' nebula (size
\~45"), located to the W of the plateau, the images show a distortion in the
morphology towards the W; this feature corresponds to the direction in which
the pulsar escapes from the SNR with a velocity of ~240 km/s. Based on the new
observations, the energetics of the SNR and of the PWN are investigated.
[5]
oai:arXiv.org:astro-ph/9904248 [pdf] - 1235328
Tropospheric Phase Calibration in Millimeter Interferometry
Submitted: 1999-04-19
We review millimeter interferometric phase variations caused by variations in
the precipitable water vapor content of the troposphere, and we discuss
techniques proposed to correct for these variations. We present observations
with the Very Large Array at 22 GHz and 43 GHz designed to test these
techniques. We find that both the Fast Switching and Paired Array calibration
techniques are effective at reducing tropospheric phase noise for radio
interferometers. In both cases, the residual rms phase fluctuations after
correction are independent of baseline length for b > b_{eff}. These techniques
allow for diffraction limited imaging of faint sources on arbitrarily long
baselines at mm wavelengths. We consider the technique of tropospheric phase
correction using a measurement of the precipitable water vapor content of the
troposphere via a radiometric measurement of the brightness temperature of the
atmosphere. Required sensitivities range from 20 mK at 90 GHz to 1 K at 185 GHz
for the MMA, and 120 mK for the VLA at 22 GHz. The minimum gain stability
requirement is 200 at 185 GHz at the MMA assuming that the astronomical
receivers are used for radiometry. This increases to 2000 for an uncooled
system. The stability requirement is 450 for the cooled system at the VLA at 22
GHz. To perform absolute radiometric phase corrections also requires knowledge
of the tropospheric parameters and models to an accuracy of a few percent. It
may be possible to perform an `empirically calibrated' radiometric phase
correction, in which the relationship between fluctuations in brightness
temperature differences with fluctuations in interferometric phases is
calibrated by observing a celestial calibrator at regular intervals.