sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Holbrook, B.

Normalized to: Holbrook, B.

8 article(s) in total. 425 co-authors, from 1 to 8 common article(s). Median position in authors list is 26,5.

[1]  oai:arXiv.org:1910.09124  [pdf] - 1990394
The LUX-ZEPLIN (LZ) Experiment
The LZ Collaboration; Akerib, D. S.; Akerlof, C. W.; Akimov, D. Yu.; Alquahtani, A.; Alsum, S. K.; Anderson, T. J.; Angelides, N.; Araújo, H. M.; Arbuckle, A.; Armstrong, J. E.; Arthurs, M.; Auyeung, H.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Bang, J.; Barry, M. J.; Barthel, J.; Bauer, D.; Bauer, P.; Baxter, A.; Belle, J.; Beltrame, P.; Bensinger, J.; Benson, T.; Bernard, E. P.; Bernstein, A.; Bhatti, A.; Biekert, A.; Biesiadzinski, T. P.; Birrittella, B.; Boast, K. E.; Bolozdynya, A. I.; Boulton, E. M.; Boxer, B.; Bramante, R.; Branson, S.; Brás, P.; Breidenbach, M.; Buckley, J. H.; Bugaev, V. V.; Bunker, R.; Burdin, S.; Busenitz, J. K.; Campbell, J. S.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Cascella, M.; Chan, C.; Cherwinka, J. J.; Chiller, A. A.; Chiller, C.; Chott, N. I.; Cole, A.; Coleman, J.; Colling, D.; Conley, R. A.; Cottle, A.; Coughlen, R.; Craddock, W. W.; Curran, D.; Currie, A.; Cutter, J. E.; da Cunha, J. P.; Dahl, C. E.; Dardin, S.; Dasu, S.; Davis, J.; Davison, T. J. R.; de Viveiros, L.; Decheine, N.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Dushkin, A.; Edberg, T. K.; Edwards, W. R.; Edwards, B. N.; Edwards, J.; Elnimr, M. M.; Emmet, W. T.; Eriksen, S. R.; Faham, C. H.; Fan, A.; Fayer, S.; Fiorucci, S.; Flaecher, H.; Florang, I. M. Fogarty; Ford, P.; Francis, V. B.; Froborg, F.; Fruth, T.; Gaitskell, R. J.; Gantos, N. J.; Garcia, D.; Geffre, A.; Gehman, V. M.; Gelfand, R.; Genovesi, J.; Gerhard, R. M.; Ghag, C.; Gibson, E.; Gilchriese, M. G. D.; Gokhale, S.; Gomber, B.; Gonda, T. G.; Greenall, A.; Greenwood, S.; Gregerson, G.; van der Grinten, M. G. D.; Gwilliam, C. B.; Hall, C. R.; Hamilton, D.; Hans, S.; Hanzel, K.; Harrington, T.; Harrison, A.; Hasselkus, C.; Haselschwardt, S. J.; Hemer, D.; Hertel, S. A.; Heise, J.; Hillbrand, S.; Hitchcock, O.; Hjemfelt, C.; Hoff, M. D.; Holbrook, B.; Holtom, E.; Hor, J. Y-K.; Horn, M.; Huang, D. Q.; Hurteau, T. W.; Ignarra, C. M.; Irving, M. N.; Jacobsen, R. G.; Jahangir, O.; Jeffery, S. N.; Ji, W.; Johnson, M.; Johnson, J.; Johnson, P.; Jones, W. G.; Kaboth, A. C.; Kamaha, A.; Kamdin, K.; Kasey, V.; Kazkaz, K.; Keefner, J.; Khaitan, D.; Khaleeq, M.; Khazov, A.; Khromov, A. V.; Khurana, I.; Kim, Y. D.; Kim, W. T.; Kocher, C. D.; Konovalov, A. M.; Korley, L.; Korolkova, E. V.; Koyuncu, M.; Kras, J.; Kraus, H.; Kravitz, S. W.; Krebs, H. J.; Kreczko, L.; Krikler, B.; Kudryavtsev, V. A.; Kumpan, A. V.; Kyre, S.; Lambert, A. R.; Landerud, B.; Larsen, N. A.; Laundrie, A.; Leason, E. A.; Lee, H. S.; Lee, J.; Lee, C.; Lenardo, B. G.; Leonard, D. S.; Leonard, R.; Lesko, K. T.; Levy, C.; Li, J.; Liu, Y.; Liao, J.; Liao, F. -T.; Lin, J.; Lindote, A.; Linehan, R.; Lippincott, W. H.; Liu, R.; Liu, X.; Loniewski, C.; Lopes, M. I.; Paredes, B. López; Lorenzon, W.; Lucero, D.; Luitz, S.; Lyle, J. M.; Lynch, C.; Majewski, P. A.; Makkinje, J.; Malling, D. C.; Manalaysay, A.; Manenti, L.; Mannino, R. L.; Marangou, N.; Markley, D. J.; MarrLaundrie, P.; Martin, T. J.; Marzioni, M. F.; Maupin, C.; McConnell, C. T.; McKinsey, D. N.; McLaughlin, J.; Mei, D. -M.; Meng, Y.; Miller, E. H.; Minaker, Z. J.; Mizrachi, E.; Mock, J.; Molash, D.; Monte, A.; Monzani, M. E.; Morad, J. A.; Morrison, E.; Mount, B. J.; Murphy, A. St. J.; Naim, D.; Naylor, A.; Nedlik, C.; Nehrkorn, C.; Nelson, H. N.; Nesbit, J.; Neves, F.; Nikkel, J. A.; Nikoleyczik, J. A.; Nilima, A.; O'Dell, J.; Oh, H.; O'Neill, F. G.; O'Sullivan, K.; Olcina, I.; Olevitch, M. A.; Oliver-Mallory, K. C.; Oxborough, L.; Pagac, A.; Pagenkopf, D.; Pal, S.; Palladino, K. J.; Palmaccio, V. M.; Palmer, J.; Pangilinan, M.; Patton, S. J.; Pease, E. K.; Penning, B. P.; Pereira, G.; Pereira, C.; Peterson, I. B.; Piepke, A.; Pierson, S.; Powell, S.; Preece, R. M.; Pushkin, K.; Qie, Y.; Racine, M.; Ratcliff, B. N.; Reichenbacher, J.; Reichhart, L.; Rhyne, C. A.; Richards, A.; Riffard, Q.; Rischbieter, G. R. C.; Rodrigues, J. P.; Rose, H. J.; Rosero, R.; Rossiter, P.; Rucinski, R.; Rutherford, G.; Rynders, D.; Saba, J. S.; Sabarots, L.; Santone, D.; Sarychev, M.; Sazzad, A. B. M. R.; Schnee, R. W.; Schubnell, M.; Scovell, P. R.; Severson, M.; Seymour, D.; Shaw, S.; Shutt, G. W.; Shutt, T. A.; Silk, J. J.; Silva, C.; Skarpaas, K.; Skulski, W.; Smith, A. R.; Smith, R. J.; Smith, R. E.; So, J.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Sosnovtsev, V. V.; Stancu, I.; Stark, M. R.; Stephenson, S.; Stern, N.; Stevens, A.; Stiegler, T. M.; Stifter, K.; Studley, R.; Sumner, T. J.; Sundarnath, K.; Sutcliffe, P.; Swanson, N.; Szydagis, M.; Tan, M.; Taylor, W. C.; Taylor, R.; Taylor, D. J.; Temples, D.; Tennyson, B. P.; Terman, P. A.; Thomas, K. J.; Thomson, J. A.; Tiedt, D. R.; Timalsina, M.; To, W. H.; Tomás, A.; Tope, T. E.; Tripathi, M.; Tronstad, D. R.; Tull, C. E.; Turner, W.; Tvrznikova, L.; Utes, M.; Utku, U.; Uvarov, S.; Va'vra, J.; Vacheret, A.; Vaitkus, A.; Verbus, J. R.; Vietanen, T.; Voirin, E.; Vuosalo, C. O.; Walcott, S.; Waldron, W. L.; Walker, K.; Wang, J. J.; Wang, R.; Wang, L.; Wang, Y.; Watson, J. R.; Migneault, J.; Weatherly, S.; Webb, R. C.; Wei, W. -Z.; While, M.; White, R. G.; White, J. T.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Wilson, K.; Witherell, M. S.; Wolfs, F. L. H.; Wolfs, J. D.; Woodward, D.; Worm, S. D.; Xiang, X.; Xiao, Q.; Xu, J.; Yeh, M.; Yin, J.; Young, I.; Zhang, C.
Comments:
Submitted: 2019-10-20, last modified: 2019-11-03
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
[2]  oai:arXiv.org:1703.09144  [pdf] - 1554108
LUX-ZEPLIN (LZ) Technical Design Report
Mount, B. J.; Hans, S.; Rosero, R.; Yeh, M.; Chan, C.; Gaitskell, R. J.; Huang, D. Q.; Makkinje, J.; Malling, D. C.; Pangilinan, M.; Rhyne, C. A.; Taylor, W. C.; Verbus, J. R.; Kim, Y. D.; Lee, H. S.; Lee, J.; Leonard, D. S.; Li, J.; Belle, J.; Cottle, A.; Lippincott, W. H.; Markley, D. J.; Martin, T. J.; Sarychev, M.; Tope, T. E.; Utes, M.; Wang, R.; Young, I.; Araújo, H. M.; Bailey, A. J.; Bauer, D.; Colling, D.; Currie, A.; Fayer, S.; Froborg, F.; Greenwood, S.; Jones, W. G.; Kasey, V.; Khaleeq, M.; Olcina, I.; Paredes, B. López; Richards, A.; Sumner, T. J.; Tomás, A.; Vacheret, A.; Brás, P.; Lindote, A.; Lopes, M. I.; Neves, F.; Rodrigues, J. P.; Silva, C.; Solovov, V. N.; Barry, M. J.; Cole, A.; Dobi, A.; Edwards, W. R.; Faham, C. H.; Fiorucci, S.; Gantos, N. J.; Gehman, V. M.; Gilchriese, M. G. D.; Hanzel, K.; Hoff, M. D.; Kamdin, K.; Lesko, K. T.; McConnell, C. T.; O'Sullivan, K.; Oliver-Mallory, K. C.; Patton, S. J.; Saba, J. S.; Sorensen, P.; Thomas, K. J.; Tull, C. E.; Waldron, W. L.; Witherell, M. S.; Bernstein, A.; Kazkaz, K.; Xu, J.; Akimov, D. Yu.; Bolozdynya, A. I.; Khromov, A. V.; Konovalov, A. M.; Kumpan, A. V.; Sosnovtsev, V. V.; Dahl, C. E.; Temples, D.; Carmona-Benitez, M. C.; de Viveiros, L.; Akerib, D. S.; Auyeung, H.; Biesiadzinski, T. P.; Breidenbach, M.; Bramante, R.; Conley, R.; Craddock, W. W.; Fan, A.; Hau, A.; Ignarra, C. M.; Ji, W.; Krebs, H. J.; Linehan, R.; Lee, C.; Luitz, S.; Mizrachi, E.; Monzani, M. E.; O'Neill, F. G.; Pierson, S.; Racine, M.; Ratcliff, B. N.; Shutt, G. W.; Shutt, T. A.; Skarpaas, K.; Stifter, K.; To, W. H.; Va'vra, J.; Whitis, T. J.; Wisniewski, W. J.; Bai, X.; Bunker, R.; Coughlen, R.; Hjemfelt, C.; Leonard, R.; Miller, E. H.; Morrison, E.; Reichenbacher, J.; Schnee, R. W.; Stark, M. R.; Sundarnath, K.; Tiedt, D. R.; Timalsina, M.; Bauer, P.; Carlson, B.; Horn, M.; Johnson, M.; Keefner, J.; Maupin, C.; Taylor, D. J.; Balashov, S.; Ford, P.; Francis, V.; Holtom, E.; Khazov, A.; Kaboth, A.; Majewski, P.; Nikkel, J. A.; O'Dell, J.; Preece, R. M.; van der Grinten, M. G. D.; Worm, S. D.; Mannino, R. L.; Stiegler, T. M.; Terman, P. A.; Webb, R. C.; Levy, C.; Mock, J.; Szydagis, M.; Busenitz, J. K.; Elnimr, M.; Hor, J. Y-K.; Meng, Y.; Piepke, A.; Stancu, I.; Kreczko, L.; Krikler, B.; Penning, B.; Bernard, E. P.; Jacobsen, R. G.; McKinsey, D. N.; Watson, R.; Cutter, J. E.; El-Jurf, S.; Gerhard, R. M.; Hemer, D.; Hillbrand, S.; Holbrook, B.; Lenardo, B. G.; Manalaysay, A. G.; Morad, J. A.; Stephenson, S.; Thomson, J. A.; Tripathi, M.; Uvarov, S.; Haselschwardt, S. J.; Kyre, S.; Nehrkorn, C.; Nelson, H. N.; Solmaz, M.; White, D. T.; Cascella, M.; Dobson, J. E. Y.; Ghag, C.; Liu, X.; Manenti, L.; Reichhart, L.; Shaw, S.; Utku, U.; Beltrame, P.; Davison, T. J. R.; Marzioni, M. F.; Murphy, A. St. J.; Nilima, A.; Boxer, B.; Burdin, S.; Greenall, A.; Powell, S.; Rose, H. J.; Sutcliffe, P.; Balajthy, J.; Edberg, T. K.; Hall, C. R.; Silk, J. S.; Hertel, S.; Akerlof, C. W.; Arthurs, M.; Lorenzon, W.; Pushkin, K.; Schubnell, M.; Boast, K. E.; Carels, C.; Fruth, T.; Kraus, H.; Liao, F. -T.; Lin, J.; Scovell, P. R.; Druszkiewicz, E.; Khaitan, D.; Koyuncu, M.; Skulski, W.; Wolfs, F. L. H.; Yin, J.; Korolkova, E. V.; Kudryavtsev, V. A.; Rossiter, P.; Woodward, D.; Chiller, A. A.; Chiller, C.; Mei, D. -M.; Wang, L.; Wei, W. -Z.; While, M.; Zhang, C.; Alsum, S. K.; Benson, T.; Carlsmith, D. L.; Cherwinka, J. J.; Dasu, S.; Gregerson, G.; Gomber, B.; Pagac, A.; Palladino, K. J.; Vuosalo, C. O.; Xiao, Q.; Buckley, J. H.; Bugaev, V. V.; Olevitch, M. A.; Boulton, E. M.; Emmet, W. T.; Hurteau, T. W.; Larsen, N. A.; Pease, E. K.; Tennyson, B. P.; Tvrznikova, L.
Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>
Submitted: 2017-03-27
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
[3]  oai:arXiv.org:1509.02910  [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration; Akerib, D. S.; Akerlof, C. W.; Akimov, D. Yu.; Alsum, S. K.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Barry, M. J.; Bauer, P.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boast, K. E.; Bolozdynya, A. I.; Boulton, E. M.; Bramante, R.; Buckley, J. H.; Bugaev, V. V.; Bunker, R.; Burdin, S.; Busenitz, J. K.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Cascella, M.; Chan, C.; Cherwinka, J. J.; Chiller, A. A.; Chiller, C.; Craddock, W. W.; Currie, A.; Cutter, J. E.; da Cunha, J. P.; Dahl, C. E.; Dasu, S.; Davison, T. J. R.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edberg, T. K.; Edwards, B. N.; Edwards, W. R.; Elnimr, M. M.; Emmet, W. T.; Faham, C. H.; Fiorucci, S.; Ford, P.; Francis, V. B.; Fu, C.; Gaitskell, R. J.; Gantos, N. J.; Gehman, V. M.; Gerhard, R. M.; Ghag, C.; Gilchriese, M. G. D.; Gomber, B.; Hall, C. R.; Harris, A.; Haselschwardt, S. J.; Hertel, S. A.; Hoff, M. D.; Holbrook, B.; Holtom, E.; Huang, D. Q.; Hurteau, T. W.; Ignarra, C. M.; Jacobsen, R. G.; Ji, W.; Ji, X.; Johnson, M.; Ju, Y.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Khazov, A.; Khromov, A. V.; Konovalov, A. M.; Korolkova, E. V.; Kraus, H.; Krebs, H. J.; Kudryavtsev, V. A.; Kumpan, A. V.; Kyre, S.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Liao, F. -T.; Lin, J.; Lindote, A.; Lippincott, W. H.; Liu, J.; Liu, X.; Lopes, M. I.; Lorenzon, W.; Luitz, S.; Majewski, P.; Malling, D. C.; Manalaysay, A. G.; Manenti, L.; Mannino, R. L.; Markley, D. J.; Martin, T. J.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. -M.; Meng, Y.; Miller, E. H.; Mock, J.; Monzani, M. E.; Morad, J. A.; Murphy, A. St. J.; Nelson, H. N.; Neves, F.; Nikkel, J. A.; O'Neill, F. G.; O'Dell, J.; O'Sullivan, K.; Olevitch, M. A.; Oliver-Mallory, K. C.; Palladino, K. J.; Pangilinan, M.; Patton, S. J.; Pease, E. K.; Piepke, A.; Powell, S.; Preece, R. M.; Pushkin, K.; Ratcliff, B. N.; Reichenbacher, J.; Reichhart, L.; Rhyne, C.; Rodrigues, J. P.; Rose, H. J.; Rosero, R.; Saba, J. S.; Sarychev, M.; Schnee, R. W.; Schubnell, M. S. G.; Scovell, P. R.; Shaw, S.; Shutt, T. A.; Silva, C.; Skarpaas, K.; Skulski, W.; Solovov, V. N.; Sorensen, P.; Sosnovtsev, V. V.; Stancu, I.; Stark, M. R.; Stephenson, S.; Stiegler, T. M.; Sumner, T. J.; Sundarnath, K.; Szydagis, M.; Taylor, D. J.; Taylor, W.; Tennyson, B. P.; Terman, P. A.; Thomas, K. J.; Thomson, J. A.; Tiedt, D. R.; To, W. H.; Tomás, A.; Tripathi, M.; Tull, C. E.; Tvrznikova, L.; Uvarov, S.; Va'vra, J.; van der Grinten, M. G. D.; Verbus, J. R.; Vuosalo, C. O.; Waldron, W. L.; Wang, L.; Webb, R. C.; Wei, W. -Z.; While, M.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Witherell, M. S.; Wolfs, F. L. H.; Woods, E.; Woodward, D.; Worm, S. D.; Yeh, M.; Yin, J.; Young, S. K.; Zhang, C.
Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
[4]  oai:arXiv.org:1205.2272  [pdf] - 873784
An Ultra-Low Background PMT for Liquid Xenon Detectors
Comments: v2 updated to include content after reviewer comments (Sep 2012)
Submitted: 2012-05-10, last modified: 2013-06-24
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
[5]  oai:arXiv.org:1207.3665  [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Comments: 12 pages, 9 figures
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. In this paper we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 meter to be achieved in approximately two days and sustained for the duration of the testing period.
[6]  oai:arXiv.org:1110.0103  [pdf] - 967104
After LUX: The LZ Program
Comments: Conference proceedings from APS DPF 2011. 9 pages, 6 figures
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.
[7]  oai:arXiv.org:1108.1836  [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Comments:
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This paper describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.
[8]  oai:arXiv.org:0912.0482  [pdf] - 902613
Status of the LUX Dark Matter Search
Comments: 4 pages, in proceedings of the SUSY09 conference
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.