sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Hofmann, R.

Normalized to: Hofmann, R.

13 article(s) in total. 192 co-authors, from 1 to 8 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:1603.02587  [pdf] - 1379057
Ground-based near-UV observations of 15 transiting exoplanets: Constraints on their atmospheres and no evidence for asymmetrical transits
Comments: 35 pages, 16 tables, 10 figures. Accepted for publication in MNRAS (March 8, 2016). Light curves are available online. Updated EXOMOP (transit modeling software) and is also available online
Submitted: 2016-03-08
Transits of exoplanets observed in the near-UV have been used to study the scattering properties of their atmospheres and possible star-planet interactions. We observed the primary transits of 15 exoplanets (CoRoT-1b, GJ436b, HAT-P-1b, HAT-P-13b, HAT-P-16b, HAT-P-22b, TrES-2b, TrES-4b, WASP-1b, WASP-12b, WASP-33b, WASP-36b, WASP-44b, WASP-48b, and WASP-77Ab) in the near-UV and several optical photometric bands to update their planetary parameters, ephemerides, search for a wavelength dependence in their transit depths to constrain their atmospheres, and determine if asymmetries are visible in their light curves. Here we present the first ground-based near-UV light curves for 12 of the targets (CoRoT-1b, GJ436b, HAT-P-1b, HAT-P-13b, HAT-P-22b, TrES-2b, TrES-4b, WASP-1b, WASP-33b, WASP-36b, WASP-48b, and WASP-77Ab). We find that none of the near-UV transits exhibit any non-spherical asymmetries, this result is consistent with recent theoretical predictions by Ben-Jaffel et al. and Turner et al. The multi-wavelength photometry indicates a constant transit depth from near-UV to optical wavelengths in 10 targets (suggestive of clouds), and a varying transit depth with wavelength in 5 targets (hinting at Rayleigh or aerosol scattering in their atmospheres). We also present the first detection of a smaller near-UV transit depth than that measured in the optical in WASP-1b and a possible opacity source that can cause such radius variations is currently unknown. WASP-36b also exhibits a smaller near-UV transit depth at 2.6$\sigma$. Further observations are encouraged to confirm the transit depth variations seen in this study.
[2]  oai:arXiv.org:1501.04738  [pdf] - 923534
The GRAVITY metrology system: narrow-angle astrometry via phase-shifting interferometry
Comments: 11 pages, 7 figures
Submitted: 2015-01-20
The VLTI instrument GRAVITY will provide very powerful astrometry by combining the light from four telescopes for two objects simultaneously. It will measure the angular separation between the two astronomical objects to a precision of 10 microarcseconds. This corresponds to a differential optical path difference (dOPD) between the targets of few nanometers and the paths within the interferometer have to be maintained stable to that level. For this purpose, the novel metrology system of GRAVITY will monitor the internal dOPDs by means of phase-shifting interferometry. We present the four-step phase-shifting concept of the metrology with emphasis on the method used for calibrating the phase shifts. The latter is based on a phase-step insensitive algorithm which unambiguously extracts phases in contrast to other methods that are strongly limited by non-linearities of the phase-shifting device. The main constraint of this algorithm is to introduce a robust ellipse fitting routine. Via this approach we are able to measure phase shifts in the laboratory with a typical accuracy of lambda/2000 or 1 nanometer of the metrology wavelength.
[3]  oai:arXiv.org:1009.1145  [pdf] - 1034741
Black Hole Mass Estimates Based on CIV are Consistent with Those Based on the Balmer Lines
Comments: Accepted for publication in The Astrophysical Journal. 37 text pages + 8 tables + 23 figures. Updated with comments by the referee and with a expanded discussion on literature data including new observations
Submitted: 2010-09-06, last modified: 2011-08-30
Using a sample of high-redshift lensed quasars from the CASTLES project with observed-frame ultraviolet or optical and near-infrared spectra, we have searched for possible biases between supermassive black hole (BH) mass estimates based on the CIV, Halpha and Hbeta broad emission lines. Our sample is based upon that of Greene, Peng & Ludwig, expanded with new near-IR spectroscopic observations, consistently analyzed high S/N optical spectra, and consistent continuum luminosity estimates at 5100A. We find that BH mass estimates based on the FWHM of CIV show a systematic offset with respect to those obtained from the line dispersion, sigma_l, of the same emission line, but not with those obtained from the FWHM of Halpha and Hbeta. The magnitude of the offset depends on the treatment of the HeII and FeII emission blended with CIV, but there is little scatter for any fixed measurement prescription. While we otherwise find no systematic offsets between CIV and Balmer line mass estimates, we do find that the residuals between them are strongly correlated with the ratio of the UV and optical continuum luminosities. Removing this dependency reduces the scatter between the UV- and optical-based BH mass estimates by a factor of approximately 2, from roughly 0.35 to 0.18 dex. The dispersion is smallest when comparing the CIV sigma_l mass estimate, after removing the offset from the FWHM estimates, and either Balmer line mass estimate. The correlation with the continuum slope is likely due to a combination of reddening, host contamination and object-dependent SED shapes. When we add additional heterogeneous measurements from the literature, the results are unchanged.
[4]  oai:arXiv.org:1007.1612  [pdf] - 1033604
GRAVITY: a four-telescope beam combiner instrument for the VLTI
Comments: 20 pages, Proceedings SPIE Astronomical Telescopes and Instrumentation Conference 2010
Submitted: 2010-07-09
GRAVITY is an adaptive optics assisted Beam Combiner for the second generation VLTI instrumentation. The instrument will provide high-precision narrow-angle astrometry and phase-referenced interferometric imaging in the astronomical K-band for faint objects. We describe the wide range of science that will be tackled with this instrument, highlighting the unique capabilities of the VLTI in combination with GRAVITY. The most prominent goal is to observe highly relativistic motions of matter close to the event horizon of Sgr A*, the massive black hole at center of the Milky Way. We present the preliminary design that fulfils the requirements that follow from the key science drivers: It includes an integrated optics, 4-telescope, dual feed beam combiner operated in a cryogenic vessel; near-infrared wavefrontsensing adaptive optics; fringe-tracking on secondary sources within the field of view of the VLTI and a novel metrology concept. Simulations show that 10 {\mu}as astrometry within few minutes is feasible for a source with a magnitude of mK = 15 like Sgr A*, given the availability of suitable phase reference sources (mK = 10). Using the same setup, imaging of mK = 18 stellar sources in the interferometric field of view is possible, assuming a full night of observations and the corresponding UV coverage of the VLTI.
[5]  oai:arXiv.org:0808.0063  [pdf] - 15046
GRAVITY: getting to the event horizon of Sgr A*
Comments: 13 pages, 11 figures, to appear in the conference proceedings of SPIE Astronomical Instrumentation, 23-28 June 2008, Marseille, France
Submitted: 2008-08-01
We present the second-generation VLTI instrument GRAVITY, which currently is in the preliminary design phase. GRAVITY is specifically designed to observe highly relativistic motions of matter close to the event horizon of Sgr A*, the massive black hole at center of the Milky Way. We have identified the key design features needed to achieve this goal and present the resulting instrument concept. It includes an integrated optics, 4-telescope, dual feed beam combiner operated in a cryogenic vessel; near infrared wavefront sensing adaptive optics; fringe tracking on secondary sources within the field of view of the VLTI and a novel metrology concept. Simulations show that the planned design matches the scientific needs; in particular that 10 microarcsecond astrometry is feasible for a source with a magnitude of K=15 like Sgr A*, given the availability of suitable phase reference sources.
[6]  oai:arXiv.org:hep-ph/0305230  [pdf] - 114443
Supersymmetric Models For Gauge Inflation
Comments: LaTeX, 16 pages, typos corrected and refs. added
Submitted: 2003-05-21, last modified: 2003-07-28
We present possible realizations of gauge inflation arising from a 5D ${\cal N}=1$ supersymmetric U(1) model, where the extra dimension is compactified on a circle. A one-loop inflaton effective 4D potential is generated, with the inflaton being a 'Wilson-line field'. It relies on a SUSY breaking. We first consider SUSY breaking to occur spontaneously within a 'no-scale' model by a non zero $F$-term of the radion superfield which transmits SUSY breaking into the 'visible' sector. As an alternative, we study $D$-term SUSY breaking originating directly from the 5D gauge supermultiplet. Together with the usual KK resummation method, we present a calculation with the world-line formalism. The latter allows one to get the resulting effective potential directly as a sum over all winding modes. For both presented scenarios, the generated effective potentials have suitable forms for realizing successful inflation, i.e. are flat enough and give the needed number of ${\rm e}$-foldings. In addition, there is a natural way to get strongly suppressed values for the potentials, which then could be associated with dark energy/quintessence.
[7]  oai:arXiv.org:astro-ph/0305423  [pdf] - 56896
The Stellar Cusp Around the Supermassive Black Hole in the Galactic Center
Comments: 59 pages, 18 figures
Submitted: 2003-05-22
We analyze deep near-IR adaptive optics imaging as well as new proper motion data of the nuclear star cluster of the Milky Way. The surface density distribution of faint stars peaks within 0.2" of the black hole candidate SgrA*. The radial density distribution of this stellar 'cusp' follows a power law of exponent 1.3-1.4. The K-band luminosity function of the overall nuclear stellar cluster (within 9" of SgrA*) resembles that of the large scale, Galactic bulge, but shows an excess of stars at K<14. We find that most of the massive early type stars at distances 1-10" from SgrA* are located in two rotating and geometrically thin disks. These disks are inclined at large angles and counter-rotate with respect to each other. Their stellar content is essentially the same, indicating that they formed at the same time. The star closest to SgrA* in 2002, S2, exhibits a 3.8 micron excess. We propose that the mid-IR emission either comes from the accretion flow around the black hole itself, or from dust in the accretion flow that is heated by the ultra-violet emission of S2.
[8]  oai:arXiv.org:astro-ph/0303408  [pdf] - 55647
Inward Bound: Studying the Galactic Centre with NAOS/CONICA
Comments: 19 pages, 7 figures
Submitted: 2003-03-18
We report on the first results obtained using adaptive optics measurements of the Galactic Centre done with NAOS/CONICA.
[9]  oai:arXiv.org:astro-ph/0210426  [pdf] - 52464
Closest Star Seen Orbiting the Supermassive Black Hole at the Centre of the Milky Way
Comments: 13 pages, 3 figures, scheduled for publication in Nature on 17 Oct 2002
Submitted: 2002-10-18
Measurements of stellar velocities and variable X-ray emission near the centre of the Milky Way have provided the strongest evidence so far that the dark mass concentrations seen in many galactic nuclei are likely supermassive black holes, but have not yet excluded several alternative configurations. Here we report ten years of high resolution astrometric imaging that allow us to trace two thirds of the orbit of the star currently closest to the compact radio source and massive black hole candidate SgrA*. In particular, we have observed both peri- and apocentre passages. Our observations show that the star is on a bound, highly elliptical Keplerian orbit around SgrA*, with an orbital period of 15.2 years and a peri-centre distance of only 17 light hours. The orbital elements require an enclosed point mass of 3.7+-1.5x10^6 solar masses. The data exclude with high confidence that the central dark mass consists of a cluster of astrophysical objects or massive, degenerate fermions, and strongly constrain the central density structure.
[10]  oai:arXiv.org:hep-ph/0111076  [pdf] - 113959
Gauged Inflation
Comments: 23 pages, 4 figures, subsection added, revision of text, to app. in PRD
Submitted: 2001-11-07, last modified: 2002-05-28
We propose a model for cosmic inflation which is based on an effective description of strongly interacting, nonsupersymmetric matter within the framework of dynamical Abelian projection and centerization. The underlying gauge symmetry is assumed to be $SU(N+1)$ with $N \gg 1$. Appealing to a thermodynamical treatment, the ground-state structure of the model is classically determined by a potential for the inflaton field (dynamical monopole condensate) which allows for nontrivially BPS saturated and thereby stable solutions. For $T<M_P$ this leads to decoupling of gravity from the inflaton dynamics. The ground state dynamics implies a heat capacity for the vacuum leading to inflation for temperatures comparable to the mass scale $M$ of the potential. The dynamics has an attractor property. In contrast to the usual slow-roll paradigm we have $m\gg H$ during inflation. As a consequence, density perturbations generated from the inflaton are irrelevant for the formation of large-scale structure, and the model has to be supplemented with an inflaton independent mechanism for the generation of spatial curvature perturbations. Within a small fraction of the Hubble time inflation is terminated by a transition of the theory to its center symmetric phase. The spontaneously broken $Z_{N+1}$ symmetry stabilizes relic vector bosons in the epochs following inflation. These heavy relics contribute to the cold dark matter of the universe and potentially originate the UHECRs beyond the GZK bound.
[11]  oai:arXiv.org:hep-ph/0201073  [pdf] - 114024
A Model for the Effective Potential of Thermalized Pure SU(Large N) Gauge Theory
Comments: 9 pages, no figures
Submitted: 2002-01-10, last modified: 2002-05-27
Based on the (in part verified) ideas of a dynamical ``abelian-ization'' and subsequent ``center-ization'' of pure SU($N$) gauge theory an effective potential for relevant field variables is constructed in the limit of large N. To do this the theory is assumed to be thermalized and to be gravitationally deformed. BPS saturation in the dynamics of the monopole field is shown to lead to a suppression of the back reaction due to classical gravity. The classical, effective description of the gauge theory can be justified for both the regime of maximal abelian gauge symmetry and the center symmetric phase.
[12]  oai:arXiv.org:astro-ph/0108318  [pdf] - 44294
CROMOS: A cryogenic near-infrared, multi-object spectrometer for the VLT
Comments: 11 pages LaTeX, 7 postscript figures. To be published in the Proceedings of the ESO Workshop Scientific Drivers for ESO Future VLT/VLTI Instrumentation held in Garching, Germany, 11-15 June 2001
Submitted: 2001-08-20
We discuss a cryogenic, multi-object near-infrared spectrometer as a second generation instrument for the VLT. The spectrometer combines 20 to 40 independent integral eld units (IFUs), which can be positioned by a cryogenic robot over the entire unvignetted eld of the VLT (~7'). Each IFU consists of a contiguous cluster of 20 to 30 pixels (0.15 to 0.25" per pixel). The individual IFUs have cold fore-optics and couple into the spectrograph with integrated bers-microlenses. The spectrometer has lambda/d-lambda~4000 and simultaneously covers the J-, H-, and K-bands with three HAWAII 2 detectors. The system is designed for operation both in seeing limited and MCAO modes. Its speed is approximately 3500 times greater than that of ISAAC and 60 times greater than NIRMOS (in H-band). The proposed instrument aims at a wide range of science, ranging from studies of galaxies/clusters in the high-z Universe (dynamics and star formation in z>1 galaxies, evolution of ellipticals, properties of distant, obscured far-IR and X-ray sources), to investigations of nearby starbursts, star clusters and properties of young low mass stars and brown dwarfs.
[13]  oai:arXiv.org:astro-ph/0001454  [pdf] - 34251
Near-Infrared-Spectroscopy with Extremely Large Telescopes: Integral-Field- versus Multi-Object-Instruments
Comments: 8 pages, 4 figures (converted to bitmap), to appear in the proceedings of the Workshop on Extremely Large Telescopes, Sweden, June 1-2, 1999, uses spie.sty (V0.91) and spiebib.bst (V0.91)
Submitted: 2000-01-26
Integral-field-spectroscopy and multi-object-spectroscopy provide the high multiplex gain required for efficient use of the upcoming generation of extremely large telescopes. We present instrument developments and designs for both concepts, and how these designs can be applied to cryogenic near-infrared instrumentation. Specifically, the fiber-based concept stands out the possibility to expand it to any number of image points, and its modularity predestines it to become the new concept for multi-field-spectroscopy. Which of the three concepts --- integral-field-, multi-object-, or multi-field-spectroscopy --- is best suited for the largest telescopes is discussed considering the size of the objects and their density on the sky.