Normalized to: Hoarau, C.
[1]
oai:arXiv.org:1911.04917 [pdf] - 2046326
KISS: a spectrometric imager for millimetre cosmology
Fasano, A.;
Aguiar, M.;
Benoit, A.;
Bideaud, A.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
de Taoro, A. P.;
Garde, G.;
Gomez, A.;
Renasco, M. F. Gomez;
Goupy, J.;
Hoarau, C.;
Hoyland, R.;
Macías-Pérez, J. F.;
Marpaud, J.;
Monfardini, A.;
Pisano, G.;
Ponthieu, N.;
Martín, J. A. Rubiño;
Tourres, D.;
Tucker, C.;
Beelen, A.;
Bres, G.;
De Petris, M.;
de Bernardis, P.;
Lagache, G.;
Marton, M.;
Rebolo, R.;
Roudier, S.
Submitted: 2019-11-12, last modified: 2020-01-23
Clusters of galaxies are used to map the large-scale structures in the
universe and as probe of universe evolution. They can be observed through the
Sunyaev-Zel'dovich (SZ) effect. At this respect the spectro-imaging at low
resolution frequency is an important tool, today, for the study of cluster of
galaxies. We have developed KISS (KIDs-Interferometer-Spectrum-Survey), a
spectrometric imager dedicated to the secondary anisotropies of the Cosmic
Microwave Background (CMB). The multi-frequency approach permits to improve the
component separation with respect to predecessor experiments. In this paper,
firstly, we provide a description of the scientific context and the state of
the art of SZ observations. Secondly, we describe the KISS instrument. Finally,
we show preliminary results of the ongoing commissioning campaign.
[2]
oai:arXiv.org:1911.13148 [pdf] - 2026468
The KISS experiment
Fasano, A.;
Aguiar, M.;
Benoit, A.;
Bideaud, A.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
de Taoro, A. P.;
Garde, G.;
Gomez, A.;
Renasco, M. F. Gomez;
Goupy, J.;
Hoarau, C.;
Hoyland, R.;
Macías-Pérez, J. F.;
Marpaud, J.;
Monfardini, A.;
Pisano, G.;
Ponthieu, N.;
Martín, J. A. Rubiño;
Tourres, D.;
Tucker, C.;
Beelen, A.;
Bres, G.;
De Petris, M.;
de Bernardis, P.;
Lagache, G.;
Lamagna, L.;
Luzzi, G.;
Marton, M.;
Masi, S.;
Rebolo, R.;
Roudier, S.
Submitted: 2019-11-29
Mapping millimetre continuum emission has become a key issue in modern
multi-wavelength astrophysics. In particular, spectrum-imaging at low frequency
resolution is an asset for characterizing the clusters of galaxies via the
Sunyaev Zeldovich (SZ) effect. In this context, we have built a ground-based
spectrum-imager named KIDs Interferometer Spectrum Survey (KISS). This
instrument is based on two 316-pixel arrays of Kinetic Inductance Detectors
(KID) cooled to 150 mK by a custom dilution refrigerator-based cryostat. By
using Ti-Al and Al absorbers, we can cover a wide frequency range between 80
and 300 GHz. In order to preserve a large instantaneous Field of View (FoV) 1
degree the spectrometer is based on a Fourier Transform interferometer. This
represents a technological challenge due to the fast scanning speed that is
needed to overcome the effects of background atmospheric fluctuations. KISS is
installed at the QUIJOTE 2.25 m telescope in Tenerife since February 2019 and
is currently in its commissioning phase. In this proceeding we present an
overview of the instrument and the latest results.
[3]
oai:arXiv.org:1802.10379 [pdf] - 1642780
Tunable sub-gap radiation detection with superconducting resonators
Dupré, O.;
Calvo, A. Benoît M.;
Catalano, A.;
Goupy, J.;
Hoarau, C.;
Klein, T.;
Calvez, K. Le;
Sacépé, B.;
Monfardini, A.;
Levy-Bertrand, F.
Submitted: 2018-02-28
We have fabricated planar amorphous Indium Oxide superconducting resonators
($T_c\sim2.8$ K) that are sensitive to frequency-selective radiation in the
range of 7 to 10 GHz. Those values lay far below twice the superconducting gap
that worths about 200 GHz. The photons detection consists in a shift of the
fundamental resonance frequency. We show that the detected frequency can be
adjusted by modulating the total length of the superconducting resonator. We
attribute those observations to the excitation of higher-order resonance modes.
The coupling between the fundamental lumped and the higher order distributed
resonance is due to the kinetic inductance non-linearity with current. These
devices, that we have called Sub-gap Kinetic Inductance Detectors (SKIDs), are
to be distinguished from the standard Kinetic Inductance Detectors (KIDs) in
which quasi-particles are generated when incident light breaks down Cooper
pairs.
[4]
oai:arXiv.org:1712.04003 [pdf] - 1666796
The NIKA2 instrument at 30-m IRAM telescope: performance and results
Catalano, A.;
Adam, R.;
Ade, P. A. R.;
P.;
André;
Aussel, H.;
Beelen, A.;
Benoit, A.;
Bideaud, A.;
Billot, N.;
Bourrion, O.;
Calvo, M.;
Comis, B.;
De Petris, M.;
Désert, F. -X.;
Doyle, S.;
Driessen, E. F. C.;
Goupy, J.;
Kramer, C.;
Lagache, G.;
Leclercq, S.;
Lestrade, J. -F.;
Macìas-Pérez, J. F.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pascale, E.;
Perotto, L.;
Pisano, G.;
Ponthieu, N.;
Revéret, V.;
Ritacco, A.;
Romero, C.;
Roussel, H.;
Ruppin, F.;
Schuster, K.;
Sievers, A.;
Triqueneaux, S.;
Tucker, C.;
Zylka, R.;
Barria, E.;
Bres, G.;
Camus, P.;
Chanthib, P.;
Donnier-Valentin, G.;
Exshaw, O.;
Garde, G.;
Gerardin, A.;
Leggeri, J. -P.;
Levy-Bertrand, F.;
Guttin, C.;
Hoarau, C.;
Grollier, M.;
Mocellin, J. -L.;
Pont, G.;
Rodenas, H.;
Tissot, O.;
Galvez, G.;
John, D.;
Ungerechts, H.;
Sanchez, S.;
Mellado, P.;
Munoz, M.;
Pierfederici, F.;
Penalver, J.;
Navarro, S.;
Bosson, G.;
Bouly, J. -L.;
Bouvier, J.;
Geraci, C.;
Li, C.;
Menu, J.;
Ponchant, N.;
Roni, S.;
Roudier, S.;
Scordillis, J. P.;
Tourres, D.;
Vescovi, C.;
Barbier, A.;
Billon-Pierron, D.;
Adane, A.;
Andrianasolo, A .;
Bracco, A.;
Coiffard, G.;
Evans, R.;
Maury, A.;
Rigby, A.
Submitted: 2017-12-11, last modified: 2018-02-04
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and
commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band
camera operating with three frequency multiplexed kilo-pixels arrays of Lumped
Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to
observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and
2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy,
such as Intra Cluster Medium from intermediate to distant clusters and so for
the follow-up of Planck satellite detected clusters, high redshift sources and
quasars, early stages of star formation and nearby galaxies emission. We
present an overview of the instrument performance as it has been evaluated at
the end of the commissioning phase.
[5]
oai:arXiv.org:1601.03969 [pdf] - 1378812
Microfabrication technology for large LEKID arrays : from NIKA2 to
future applications
Goupy, J.;
Adane, A.;
Benoit, A.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
Coiffard, G.;
Hoarau, C.;
Leclercq, S.;
Sueur, H. Le;
Macias-Perez, J.;
Monfardini, A.;
Peck, I.;
Schuster, K.
Submitted: 2016-01-15
The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full
maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow
directly comparing LEKID performance with other competing technologies (TES,
doped silicon) in the mm and sub-mm range. A continuing effort is ongoing to
improve the microfabrication technologies and concepts in order to satisfy the
requirements of new instruments. More precisely, future satellites dedicated to
CMB (Cosmic Microwave Background) studies will require the same focal plane
technology to cover, at least, the frequency range of 60 to 600 GHz. Aluminium
LEKID developed for NIKA have so far demonstrated, under real telescope
conditions, performance approaching photon-noise limitation in the band 120-300
GHz. By implementing superconducting bi-layers we recently demonstrated LEKID
arrays working in the range 80-120 GHz and with sensitivities approaching the
goals for CMB missions. NIKA itself (350 pixels) is followed by a more
ambitious project requiring several thousands (3000-5000) pixels. NIKA2 has
been installed in October 2015 at the IRAM 30-m telescope. We will describe in
detail the technological improvements that allowed a relatively harmless
10-fold up-scaling in pixels count without degrading the initial sensitivity.
In particular we will briefly describe a solution to simplify the difficult
fabrication step linked to the slot-line propagation mode in coplanar
waveguide.