Hirakuri, S.
Normalized to: Hirakuri, S.
2 article(s) in total. 86 co-authors, from 1 to 3 common article(s). Median position in authors list is 22,0.
[1]
oai:arXiv.org:astro-ph/0611232 [pdf] - 1233970
Hard X-ray Detector (HXD) on Board Suzaku
Takahashi, T.;
Abe, K.;
Endo, M.;
Endo, Y.;
Ezoe, Y.;
Fukazawa, Y.;
Hamaya, M.;
Hirakuri, S.;
Hong, S.;
Horii, M.;
Inoue, H.;
Isobe, N.;
Itoh, T.;
Iyomoto, N.;
Kamae, T.;
Kasama, D.;
Kataoka, J.;
Kato, H.;
Kawaharada, M.;
Kawano, N.;
Kawashima, K.;
Kawasoe, S.;
Kishishita, T.;
Kitaguchi, T.;
Kobayashi, Y.;
Kokubun, M.;
Kotoku, J.;
Kouda, M.;
Kubota, A.;
Kuroda, Y.;
Madejski, G.;
Makishima, K.;
Masukawa, K.;
Matsumoto, Y.;
Mitani, T.;
Miyawaki, R.;
Mizuno, T.;
Mori, K.;
Mori, M.;
Murashima, M.;
Murakami, T.;
Nakazawa, K.;
Niko, H.;
Nomachi, M.;
Okada, Y.;
Ohno, M.;
Oonuki, K.;
Ota, N.;
Ozawa, H.;
Sato, G.;
Shinoda, S.;
Sugiho, M.;
Suzuki, M.;
Taguchi, K.;
Takahashi, H.;
Takahashi, I.;
Takeda, S.;
Tamura, K.;
Tamura, T.;
Tanaka, T.;
Tanihata, C.;
Tashiro, M.;
Terada, Y.;
Tominaga, S.;
Uchiyama, Y.;
Watanabe, S.;
Yamaoka, K.;
Yanagida, T.;
Yonetoku, D.
Submitted: 2006-11-07
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from
10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators.
The HXD is designed to achieve an extremely low in-orbit back ground based on a
combination of new techniques, including the concept of well-type active shield
counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV,
the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2}
keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2}
keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for
the phoswich counter. Tight active shielding of the HXD results in a large
array of guard counters surrounding the main detector parts. These
anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large
effective area for sub-MeV to MeV gamma-rays. They work as an excellent
gamma-ray burst monitor with limited angular resolution (~5 degree). The
on-board signal-processing system and the data transmitted to the ground are
also described.
[2]
oai:arXiv.org:astro-ph/0611233 [pdf] - 1233971
In-Orbit Performance of the Hard X-ray Detector on board Suzaku
Kokubun, M.;
Makishima, K.;
Takahashi, T.;
Murakami, T.;
Tashiro, M.;
Fukazawa, Y.;
Kamae, T.;
Madejski, G. M.;
Nakazawa, K.;
Yamaoka, K.;
Terada, Y.;
Yonetoku, D.;
Watanabe, S.;
Tamagawa, T.;
Mizuno, T.;
Kubota, A.;
Isobe, N.;
Takahashi, I.;
Sato, G.;
Takahashi, H.;
Hong, S.;
Kawaharada, M.;
Kawano, N.;
Mitani, T.;
Murashima, M.;
Suzuki, M.;
Abe, K.;
Miyawaki, R.;
Ohno, M.;
Tanaka, T.;
Yanagida, T.;
Itoh, T.;
Ohnuki, K.;
Tamura, K.;
Endo, Y.;
Hirakuri, S.;
Hiruta, T.;
Kitaguchi, T.;
Kishishita, T.;
Sugita, S.;
Takahashi, T.;
Takeda, S.;
Enoto, T.;
Hirasawa, A.;
Katsuta, J.;
Matsumura, S.;
Onda, K.;
Sato, M.;
Ushio, M.;
Ishikawa, S.;
Murase, K.;
Odaka, H.;
Suzuki, M.;
Yaji, Y.;
Yamada, S.;
Yamasaki, T.;
Yuasa, T.
Submitted: 2006-11-07
The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on
board the X-ray astronomy satellite Suzaku are described. Its basic
performances, including a wide energy bandpass of 10-600 keV, energy
resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high
background rejection efficiency, have been confirmed by extensive in-orbit
calibrations. The long-term gains of PIN-Si diodes have been stable within 1%
for half a year, and those of scintillators have decreased by 5-20%. The
residual non-X-ray background of the HXD is the lowest among past non-imaging
hard X-ray instruments in energy ranges of 15-70 and 150-500 keV. We provide
accurate calibrations of energy responses, angular responses, timing accuracy
of the HXD, and relative normalizations to the X-ray CCD cameras using multiple
observations of the Crab Nebula.