Himpsl, A.
Normalized to: Himpsl, A.
4 article(s) in total. 11 co-authors, from 1 to 4 common article(s). Median position in authors list is 3,5.
[1]
oai:arXiv.org:1511.07722 [pdf] - 1317178
Intense Infrared Scintillation of Liquid Ar-Xe Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Hagn, H.;
Hofmann, M.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Intense infrared (IR) light emission from liquid Ar-Xe mixtures has been
observed using 12 keV electron-beam excitation. The emission peaks at a
wavelength of 1.18 $\mu$m and the half-width of the emission band is 0.1
$\mu$m. Maximum intensity has been found for a 10 ppm xenon admixture in liquid
argon. The conversion efficiency of electron beam-power to IR-light is about 1%
(10000 photons per MeV electron energy deposited). A possible application of
this intense IR emission for a new particle discrimination concept in liquid
noble gas detectors is discussed. No light emission was found for perfectly
purified liquid argon in the wavelength range from 0.5 to 3.5 $\mu$m on the
current level of sensitivity.
[2]
oai:arXiv.org:1511.07723 [pdf] - 1317179
Intense Vacuum-Ultraviolet and Infrared Scintillation of Liquid Ar-Xe
Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Vacuum ultraviolet light emission from xenon-doped liquid argon is described
in the context of liquid noble gas particle detectors. Xenon concentrations in
liquid argon from 0.1 ppm to 1000 ppm were studied. The energy transfer from
the second excimer continuum of argon ($\sim$127 nm) to the second excimer
continuum of xenon ($\sim$174 nm) is observed by recording optical emission
spectra. The transfer almost saturates at a xenon concentration of $\sim$10 ppm
for which, in addition, an intense emission in the infrared at a peak
wavelength of 1.17 $\mu$m with (13000$\pm$4000) photons per MeV deposited by
electrons had been found. The corresponding value for the VUV emission at a
peak wavelength of 174 nm (second excimer continuum of xenon) is determined to
be (20000$\pm$6000) photons per MeV electron energy deposited. Under these
excitation conditions pure liquid argon emits (22000$\pm$3000) photons per MeV
electron energy deposited at a peak wavelength of 127nm. An electron-beam
induced emission spectrum for the 10 ppm Ar-Xe liquid mixture ranging from 115
nm to 3.5 $\mu$m is presented. VUV emission spectra from xenon-doped liquid
argon with exponentially varied xenon concentrations from 0.1 ppm to 1000 ppm
are also shown. Time structure measurements of the light emissions at
well-defined wavelength positions in the vacuum ultraviolet as well as in the
near-infrared are presented.
[3]
oai:arXiv.org:1511.07725 [pdf] - 1317181
Attenuation of vacuum ultraviolet light in pure and xenon-doped liquid
argon - an approach to an assignment of the near-infrared emission from the
mixture
Submitted: 2015-11-24
Results of transmission experiments of vacuum ultraviolet light through a
11.6 cm long cell filled with pure and xenon-doped liquid argon are described.
Pure liquid argon shows no attenuation down to the experimental
short-wavelength cut-off at 118nm. Based on a conservative approach, a lower
limit of 1.10 m for the attenuation length of its own scintillation light could
be derived. Adding xenon to liquid argon at concentrations on the order of
parts per million leads to strong xenon-related absorption features which are
used for a tentative assignment of the recently found near-infrared emission
observed in electron-beam excited liquid argon-xenon mixtures. Two of the three
absorption features can be explained by perturbed xenon transitions and the
third one by a trapped exciton (Wannier-Mott) impurity state. A calibration
curve connecting the equivalent width of the absorption line at 140 nm with
xenon concentration is provided.
[4]
oai:arXiv.org:1511.07726 [pdf] - 1317182
Attenuation measurements of vacuum ultraviolet light in liquid argon
revisited
Submitted: 2015-11-24
The attenuation of vacuum ultraviolet light in liquid argon in the context of
its application in large liquid noble gas detectors has been studied. Compared
to a previous publication several technical issues concerning transmission
measurements in general are addressed and several systematic effects were
quantitatively measured. Wavelength-resolved transmission measurements have
been performed from the vacuum ultraviolet to the near-infrared region. On the
current level of sensitivity with a length of the optical path of 11.6 cm, no
xenon-related absorption effects could be observed, and pure liquid argon is
fully transparent down to the short wavelength cut-off of the experimental
setup at 118 nm. A lower limit for the attenuation length of pure liquid argon
for its own scintillation light has been estimated to be 1.10 m based on a very
conservative approach.