Normalized to: Hillbrand, S.
[1]
oai:arXiv.org:1802.06039 [pdf] - 2061504
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Akerib, D. S.;
Akerlof, C. W.;
Alsum, S. K.;
Araújo, H. M.;
Arthurs, M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Bauer, D.;
Belle, J.;
Beltrame, P.;
Benson, T.;
Bernard, E. P.;
Biesiadzinski, T. P.;
Boast, K. E.;
Boxer, B.;
Brás, P.;
Buckley, J. H.;
Bugaev, V. V.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Chan, C.;
Cherwinka, J. J.;
Cole, A.;
Cottle, A.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
Dahl, C. E.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, W. R.;
Fan, A.;
Fayer, S.;
Fiorucci, S.;
Fruth, T.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
van der Grinten, M. G. D.;
Hall, C. R.;
Hans, S.;
Hanzel, K.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hillbrand, S.;
Hjemfelt, C.;
Hoff, M. D.;
Hor, J. Y-K.;
Huang, D. Q.;
Ignarra, C. M.;
Ji, W.;
Kaboth, A. C.;
Kamdin, K.;
Keefner, J.;
Khaitan, D.;
Khazov, A.;
Kim, Y. D.;
Kocher, C. D.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kreczko, L.;
Krikler, B.;
Kudryavtsev, V. A.;
Kyre, S.;
Lee, J.;
Lenardo, B. G.;
Leonard, D. S.;
Lesko, K. T.;
Levy, C.;
Li, J.;
Liao, J.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Linehan, R.;
Lippincott, W. H.;
Liu, X.;
Lopes, M. I.;
Paredes, B. López;
Lorenzon, W.;
Luitz, S.;
Lyle, J. M.;
Majewski, P.;
Manalaysay, A.;
Mannino, R. L.;
Maupin, C.;
McKinsey, D. N.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Morrison, E.;
Mount, B. J.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikoleyczik, J.;
O'Sullivan, K.;
Olcina, I.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Patton, S. J.;
Pease, E. K.;
Penning, B.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Rhyne, C. A.;
Richards, A.;
Rodrigues, J. P.;
Rosero, R.;
Rossiter, P.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silk, J. J.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stancu, I.;
Stark, M. R.;
Stiegler, T. M.;
Stifter, K.;
Szydagis, M.;
Taylor, W. C.;
Taylor, R.;
Taylor, D. J.;
Temples, D.;
Terman, P. A.;
Thomas, K. J.;
Timalsina, M.;
To, W. H.;
Tomás, A.;
Tope, T. E.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Utku, U.;
Va'vra, J.;
Vacheret, A.;
Verbus, J. R.;
Voirin, E.;
Waldron, W. L.;
Watson, J. R.;
Webb, R. C.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, I.
Submitted: 2018-02-16, last modified: 2019-12-02
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well
underway, LZ is on track for commissioning at SURF in 2020.
[3]
oai:arXiv.org:1803.01018 [pdf] - 1783724
The EBEX Balloon Borne Experiment - Detectors and Readout
The EBEX Collaboration;
Abitbol, Maximilian;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen M.;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Irwin, Kent;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2018-03-02, last modified: 2018-07-30
EBEX was a long-duration balloon-borne experiment to measure the polarization
of the cosmic microwave background. The experiment had three frequency bands
centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array
of transition edge sensor (TES) bolometers aboard a balloon platform; shortly
after reaching float we operated 504, 342, and 109 TESs at each of the bands,
respectively. We describe the design and characterization of the array and the
readout system. We give the distributions of measured thermal conductances,
normal resistances, and transition temperatures. With the exception of the
thermal conductance at 150 GHz. We measured median low-loop-gain time constants
$\tau_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements
of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz
and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively.
We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the
three bands, respectively. EBEX pioneered the use of the digital version of the
frequency domain multiplexing (FDM) system which multiplexed the bias and
readout of 16 bolometers onto two wires. We present accounting of the measured
noise equivalent power. The median per-detector noise equivalent temperatures
referred to a black body with a temperature of 2.725 K are 400, 920, and 14500
$\mu$K$\sqrt{s}$ for the three bands, respectively. We compare these values to
our pre-flight predictions and to a previous balloon payload, discuss the
sources of excess noise, and the path for a future payload to make full use of
the balloon environment.
[4]
oai:arXiv.org:1711.01314 [pdf] - 1877825
Intensity-Coupled-Polarization in Instruments with a Continuously
Rotating Half-Wave Plate
Didier, Joy;
Miller, Amber D.;
Araujo, Derek;
Aubin, François;
Geach, Christopher;
Johnson, Bradley;
Korotkov, Andrei;
Raach, Kate;
Westbrook, Benjamin;
Young, Karl;
Aboobaker, Asad M.;
Ade, Peter;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Jones, Terry;
Klein, Jeff;
Lee, Adrian;
Limon, Michele;
MacDermid, Kevin;
Milligan, Michael;
Pascale, Enzo;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Zilic, Kyle
Submitted: 2017-11-03, last modified: 2018-02-28
We discuss a systematic effect associated with measuring polarization with a
continuously rotating half-wave plate. The effect was identified with the data
from the E and B Experiment (EBEX), which was a balloon-borne instrument
designed to measure the polarization of the CMB as well as that from Galactic
dust. The data show polarization fraction larger than 10\% while less than 3\%
were expected from instrumental polarization. We give evidence that the excess
polarization is due to detector non-linearity in the presence of a continuously
rotating HWP. The non-linearity couples intensity signals into polarization. We
develop a map-based method to remove the excess polarization. Applying this
method for the 150 (250) GHz bands data we find that 81\% (92\%) of the excess
polarization was removed. Characterization and mitigation of this effect is
important for future experiments aiming to measure the CMB B-modes with a
continuously rotating HWP.
[5]
oai:arXiv.org:1703.03847 [pdf] - 1783689
The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
The EBEX Collaboration;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Savini, Giorgio;
Spencer, Locke;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2017-03-10, last modified: 2017-05-30
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic
microwave background polarimeter that flew over Antarctica in 2013. We describe
the experiment's optical system, receiver, and polarimetric approach, and
report on their in-flight performance. EBEX had three frequency bands centered
on 150, 250, and 410 GHz. To make efficient use of limited mass and space we
designed a 115 cm$^{2}$sr high throughput optical system that had two ambient
temperature mirrors and four anti-reflection coated polyethylene lenses per
focal plane. All frequency bands shared the same optical train. Polarimetry was
achieved with a continuously rotating achromatic half-wave plate (AHWP) that
was levitated with a superconducting magnetic bearing (SMB). Rotation stability
was 0.45 % over a period of 10 hours, and angular position accuracy was 0.01
degrees. This is the first use of a SMB in astrophysics. The measured
modulation efficiency was above 90 % for all bands. To our knowledge the 109 %
fractional bandwidth of the AHWP was the broadest implemented to date. The
receiver that contained one lens and the AHWP at a temperature of 4 K, the
polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K
performed according to specifications giving focal plane temperature stability
with fluctuation power spectrum that had $1/f$ knee at 2 mHz. EBEX was the
first balloon-borne instrument to implement technologies characteristic of
modern CMB polarimeters including high throughput optical systems, and large
arrays of transition edge sensor bolometric detectors with mutiplexed readouts.
[6]
oai:arXiv.org:1702.07020 [pdf] - 1783687
The EBEX Balloon-Borne Experiment - Gondola, Attitude Control, and
Control Software
The EBEX Collaboration;
Aboobaker, Asad;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Moncelsi, Lorenzo;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2017-02-22, last modified: 2017-04-11
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument
designed to measure the polarization of the cosmic microwave background (CMB)
radiation. EBEX was the first balloon-borne instrument to implement a
kilo-pixel array of transition edge sensor (TES) bolometric detectors and the
first CMB experiment to use the digital version of the frequency domain
multiplexing system for readout of the TES array. The scan strategy relied on
40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique
demands on the design and operation of the payload that resulted from these new
technologies and the scan strategy. We describe the solutions implemented
including the development of a power system designed to provide a total of at
least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors'
readout system, software to manage and handle the data of the kilo-pixel array,
and specialized attitude reconstruction software. We present flight performance
data showing faultless management of the TES array, adequate powering and
cooling of the readout electronics, and constraint of attitude reconstruction
errors such that the spurious B-modes they induced were less than 10% of CMB
B-mode power spectrum with $r=0.05$.
[8]
oai:arXiv.org:1608.05456 [pdf] - 1459468
Instrumental performance and results from testing of the BLAST-TNG
receiver, submillimeter optics, and MKID arrays
Galitzki, Nicholas;
Ade, Peter;
Angile, Francesco E.;
Ashton, Peter;
Austermann, Jason;
Billings, Tashalee;
Che, George;
Cho, Hsiao-Mei;
Davis, Kristina;
Devlin, Mark;
Dicker, Simon;
Dober, Bradley J.;
Fissel, Laura M.;
Fukui, Yasuo;
Gao, Jiansong;
Gordon, Samuel;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Lowe, Ian;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
McKenney, Christopher;
Nati, Federico;
Novak, Giles;
Pascale, Enzo;
Pisano, Giampaolo;
Santos, Fabio P.;
Scott, Douglas;
Sinclair, Adrian;
Soler, Juan D.;
Tucker, Carole;
Underhill, Matthew;
Vissers, Michael;
Williams, Paul
Submitted: 2016-08-18
Polarized thermal emission from interstellar dust grains can be used to map
magnetic fields in star forming molecular clouds and the diffuse interstellar
medium (ISM). The Balloon-borne Large Aperture Submillimeter Telescope for
Polarimetry (BLASTPol) flew from Antarctica in 2010 and 2012 and produced
degree-scale polarization maps of several nearby molecular clouds with
arcminute resolution. The success of BLASTPol has motivated a next-generation
instrument, BLAST-TNG, which will use more than 3000 linear polarization
sensitive microwave kinetic inductance detectors (MKIDs) combined with a 2.5m
diameter carbon fiber primary mirror to make diffraction-limited observations
at 250, 350, and 500 $\mu$m. With 16 times the mapping speed of BLASTPol,
sub-arcminute resolution, and a longer flight time, BLAST-TNG will be able to
examine nearby molecular clouds and the diffuse galactic dust polarization
spectrum in unprecedented detail. The 250 $\mu$m detector array has been
integrated into the new cryogenic receiver, and is undergoing testing to
establish the optical and polarization characteristics of the instrument.
BLAST-TNG will demonstrate the effectiveness of kilo-pixel MKID arrays for
applications in submillimeter astronomy. BLAST-TNG is scheduled to fly from
Antarctica in December 2017 for 28 days and will be the first balloon-borne
telescope to offer a quarter of the flight for "shared risk" observing by the
community.
[9]
oai:arXiv.org:1602.03249 [pdf] - 1356056
A high-resolution pointing system for fast scanning platforms: The EBEX
example
Didier, Joy;
Chapman, Daniel;
Aboobaker, Asad;
Araujo, Derek;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Korotkov, Andrei;
Limon, Michele;
Miller, Amber;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Greg;
Vinokurov, Yuri
Submitted: 2016-02-09
The E and B experiment (EBEX) is a balloon-borne telescope designed to
measure the polarization of the cosmic microwave background with 8' resolution
employing a gondola scanning with speeds of order degree per second. In January
2013, EBEX completed 11 days of observations in a flight over Antarctica
covering $\sim$ 6000 square degrees of the sky. The payload is equipped with
two redundant star cameras and two sets of three orthogonal gyroscopes to
reconstruct the telescope attitude. The EBEX science goals require the pointing
to be reconstructed to approximately 10" in the map domain, and in-flight
attitude control requires the real time pointing to be accurate to $\sim$
0.5$^{\circ}$ . The high velocity scan strategy of EBEX coupled to its float
altitude only permits the star cameras to take images at scan turnarounds,
every $\sim$ 40 seconds, and thus requires the development of a pointing system
with low noise gyroscopes and carefully controlled systematic errors. Here we
report on the design of the pointing system and on a simulation pipeline
developed to understand and minimize the effects of systematic errors. The
performance of the system is evaluated using the 2012/2013 flight data, and we
show that we achieve a pointing error with RMS=25" on 40 seconds azimuth
throws, corresponding to an error of $\sim$ 4.6" in the map domain.
[10]
oai:arXiv.org:1601.07923 [pdf] - 1350058
Temperature calibration of the E and B experiment
Aubin, Francois;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen;
Geach, Christopher;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Macdermid, Kevin;
Marchenko, Valerie;
Miller, Amber D.;
Milligan, Michael;
Pascale, Enzo;
Puglisi, Giuseppe;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2016-01-28
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to
measure the polarization of the cosmic microwave background radiation and to
characterize the polarization of galactic dust. EBEX was launched December 29,
2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky
during 11 days at three frequency bands centered around 150, 250 and 410 GHz.
EBEX was the first experiment to operate a kilo-pixel array of transition-edge
sensor bolometers and a continuously rotating achromatic half-wave plate aboard
a balloon platform. It also pioneered the use of detector readout based on
digital frequency domain multiplexing.
We describe the temperature calibration of the experiment. The gain response
of the experiment is calibrated using a two-step iterative process. We use
signals measured on passes across the Galactic plane to convert from
readout-system counts to power. The effective smoothing scale of the EBEX
optics and the star camera-to-detector offset angles are determined through
\c{hi}2 minimization using the compact HII region RCW 38. This two-step process
is initially performed with parameters measured before the EBEX 2013 flight and
then repeated until the calibration factor and parameters converge.
[11]
oai:arXiv.org:1509.05392 [pdf] - 1330249
BFORE: The B-mode Foreground Experiment
Niemack, Michael D.;
Ade, Peter;
de Bernardis, Francesco;
Boulanger, Francois;
Bryan, Sean;
Devlin, Mark;
Dunkley, Joanna;
Eales, Steve;
Gomez, Haley;
Groppi, Chris;
Henderson, Shawn;
Hillbrand, Seth;
Hubmayr, Johannes;
Mauskopf, Philip;
McMahon, Jeff;
Miville-Deschênes, Marc-Antoine;
Pascale, Enzo;
Pisano, Giampaolo;
Novak, Giles;
Scott, Douglas;
Soler, Juan;
Tucker, Carole
Submitted: 2015-09-17, last modified: 2015-12-20
The B-mode Foreground Experiment (BFORE) is a proposed NASA balloon project
designed to make optimal use of the sub-orbital platform by concentrating on
three dust foreground bands (270, 350, and 600 GHz) that complement
ground-based cosmic microwave background (CMB) programs. BFORE will survey ~1/4
of the sky with 1.7 - 3.7 arcminute resolution, enabling precise
characterization of the Galactic dust that now limits constraints on inflation
from CMB B-mode polarization measurements. In addition, BFORE's combination of
frequency coverage, large survey area, and angular resolution enables science
far beyond the critical goal of measuring foregrounds. BFORE will constrain the
velocities of thousands of galaxy clusters, provide a new window on the cosmic
infrared background, and probe magnetic fields in the interstellar medium. We
review the BFORE science case, timeline, and instrument design, which is based
on a compact off-axis telescope coupled to >10,000 superconducting detectors.
[12]
oai:arXiv.org:1510.01983 [pdf] - 1289916
Stratospheric Imaging of Polar Mesospheric Clouds: A New Window on
Small-Scale Atmospheric Dynamics
Miller, A. D.;
Fritts, D. C.;
Chapman, D.;
Jones, G.;
Limon, M.;
Araujo, D.;
Didier, J.;
Hillbrand, S.;
Kjellstrand, C. B.;
Korotkov, A.;
Tucker, G.;
Vinokurov, Y.;
Wan, K.;
Wang, L.
Submitted: 2015-10-07
Instabilities and turbulence extending to the smallest dynamical scales play
important roles in the deposition of energy and momentum by gravity waves
throughout the atmosphere. However, these dynamics and their effects have been
impossible to quantify to date due to lack of observational guidance.
Serendipitous optical images of polar mesospheric clouds at ~82 km obtained by
star cameras aboard a cosmology experiment deployed on a stratospheric balloon
provide a new observational tool, revealing instability and turbulence
structures extending to spatial scales < 20 m. At 82 km, this resolution
provides sensitivity extending to the smallest turbulence scale not strongly
influenced by viscosity: the "inner scale" of turbulence,
$l_0\sim$10($\nu^3$/$\epsilon$)$^{1/4}$. Such images represent a new window
into small-scale dynamics that occur throughout the atmosphere but are
impossible to observe in such detail at any other altitude. We present a sample
of images revealing a range of dynamics features, and employ numerical
simulations that resolve these dynamics to guide our interpretation of several
observed events.
[13]
oai:arXiv.org:1409.7084 [pdf] - 896558
The Next Generation BLAST Experiment
Galitzki, Nicholas;
Ade, Peter A. R.;
Angilè, Francesco E.;
Ashton, Peter;
Beall, James A.;
Becker, Dan;
Bradford, Kristi J.;
Che, George;
Cho, Hsiao-Mei;
Devlin, Mark J.;
Dober, Bradley J.;
Fissel, Laura M.;
Fukui, Yasuo;
Gao, Jiansong;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Van Lanen, Jeff;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
Nakamura, Fumitaka;
Novak, Giles;
Pappas, David P.;
Pascale, Enzo;
Pisano, Giampaolo;
Santos, Fabio P.;
Savini, Giorgio;
Scott, Douglas;
Stanchfield, Sara;
Tucker, Carole;
Ullom, Joel N.;
Underhill, Matthew;
Vissers, Michael R.;
Ward-Thompson, Derek
Submitted: 2014-09-24, last modified: 2014-11-12
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry
(BLASTPol) was a suborbital experiment designed to map magnetic fields in order
to study their role in star formation processes. BLASTPol made detailed
polarization maps of a number of molecular clouds during its successful flights
from Antarctica in 2010 and 2012. We present the next-generation BLASTPol
instrument (BLAST-TNG) that will build off the success of the previous
experiment and continue its role as a unique instrument and a test bed for new
technologies. With a 16-fold increase in mapping speed, BLAST-TNG will make
larger and deeper maps. Major improvements include a 2.5 m carbon fiber mirror
that is 40% wider than the BLASTPol mirror and ~3000 polarization sensitive
detectors. BLAST-TNG will observe in three bands at 250, 350, and 500 microns.
The telescope will serve as a pathfinder project for microwave kinetic
inductance detector (MKID) technology, as applied to feedhorn coupled
submillimeter detector arrays. The liquid helium cooled cryostat will have a
28-day hold time and will utilize a closed-cycle $^3$He refrigerator to cool
the detector arrays to 270 mK. This will enable a detailed mapping of more
targets with higher polarization resolution than any other submillimeter
experiment to date. BLAST-TNG will also be the first balloon-borne telescope to
offer shared risk observing time to the community. This paper outlines the
motivation for the project and the instrumental design.
[14]
oai:arXiv.org:1410.4892 [pdf] - 1222641
STARS: A software application for the EBEX autonomous daytime star
cameras
Submitted: 2014-10-17
The E and B Experiment (EBEX) is a balloon-borne telescope designed to probe
polarization signals in the CMB resulting from primordial gravitational waves,
gravitational lensing, and Galactic dust emission. EBEX completed an 11 day
flight over Antarctica in January 2013 and data analysis is underway. EBEX
employs two star cameras to achieve its real-time and post-flight pointing
requirements. We wrote a software application called STARS to operate, command,
and collect data from each of the star cameras, and to interface them with the
main flight computer. We paid special attention to make the software robust
against potential in-flight failures. We report on the implementation, testing,
and successful in flight performance of STARS.
[15]
oai:arXiv.org:1407.6249 [pdf] - 880220
A LEKID-based CMB instrument design for large-scale observations in
Greenland
Araujo, D. C.;
Ade, P. A. R.;
Bond, J. R.;
Bradford, K. J.;
Chapman, D.;
Che, G.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C. E.;
Hillbrand, S. N.;
Johnson, B. R.;
Jones, G.;
Limon, M.;
Miller, A. D.;
Mauskopf, P.;
McCarrick, H.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2014-07-10, last modified: 2014-10-10
We present the results of a feasibility study, which examined deployment of a
ground-based millimeter-wave polarimeter, tailored for observing the cosmic
microwave background (CMB), to Isi Station in Greenland. The instrument for
this study is based on lumped-element kinetic inductance detectors (LEKIDs) and
an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The
telescope is mounted inside the receiver and cooled to $<\,4$ K by a
closed-cycle $^4$He refrigerator to reduce background loading on the detectors.
Linearly polarized signals from the sky are modulated with a metal-mesh
half-wave plate that is rotated at the aperture stop of the telescope with a
hollow-shaft motor based on a superconducting magnetic bearing. The modular
detector array design includes at least 2300 LEKIDs, and it can be configured
for spectral bands centered on 150~GHz or greater. Our study considered
configurations for observing in spectral bands centered on 150, 210 and
267~GHz. The entire polarimeter is mounted on a commercial precision rotary air
bearing, which allows fast azimuth scan speeds with negligible vibration and
mechanical wear over time. A slip ring provides power to the instrument,
enabling circular scans (360 degrees of continuous rotation). This mount, when
combined with sky rotation and the latitude of the observation site, produces a
hypotrochoid scan pattern, which yields excellent cross-linking and enables
34\% of the sky to be observed using a range of constant elevation scans. This
scan pattern and sky coverage combined with the beam size (15~arcmin at
150~GHz) makes the instrument sensitive to $5 < \ell < 1000$ in the angular
power spectra.
[16]
oai:arXiv.org:1407.6894 [pdf] - 1215912
The performance of the bolometer array and readout system during the
2012/2013 flight of the E and B experiment (EBEX)
MacDermid, Kevin;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Francois;
Baccigalupi, Carlo;
Bandura, Kevin;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Hannes;
Irwin, Kent;
Johnson, Bradley;
Jaffe, Andrew;
Jones, Terry;
Kisner, Ted;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Greg;
Westbrook, Ben;
Zilic, Kyle
Submitted: 2014-07-22
EBEX is a balloon-borne telescope designed to measure the polarization of the
cosmic microwave background radiation. During its eleven day science flight in
the Austral Summer of 2012, it operated 955 spider-web transition edge sensor
(TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the
first time that an array of TES bolometers has been used on a balloon platform
to conduct science observations. Polarization sensitivity was provided by a
wire grid and continuously rotating half-wave plate. The balloon implementation
of the bolometer array and readout electronics presented unique development
requirements. Here we present an outline of the readout system, the remote
tuning of the bolometers and Superconducting QUantum Interference Device
(SQUID) amplifiers, and preliminary current noise of the bolometer array and
readout system.
[17]
oai:arXiv.org:1407.3756 [pdf] - 1215656
The next-generation BLASTPol experiment
Dober, Bradley;
Ade, Peter A. R.;
Ashton, Peter;
Angilè, Francesco E.;
Beall, James A.;
Becker, Dan;
Bradford, Kristi J.;
Che, George;
Cho, Hsiao-Mei;
Devlin, Mark J.;
Fissel, Laura M.;
Fukui, Yasuo;
Galitzki, Nicholas;
Gao, Jiansong;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Van Lanen, Jeff;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
Nakamura, Fumitaka;
Novak, Giles;
Pappas, David P.;
Pascale, Enzo;
Santos, Fabio P.;
Savini, Giorgio;
Scott, Douglas;
Stanchfield, Sara;
Ullom, Joel N.;
Underhill, Matthew;
Vissers, Michael R.;
Ward-Thompson, Derek
Submitted: 2014-07-14
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry
(BLASTPol) is a suborbital mapping experiment designed to study the role
magnetic fields play in star formation. BLASTPol has had two science flights
from McMurdo Station, Antarctica in 2010 and 2012. These flights have produced
thousands of polarization vectors at 250, 350 and 500 microns in several
molecular cloud targets. We present the design, specifications, and progress
towards the next-generation BLASTPol experiment (BLAST-TNG). BLAST-TNG will fly
a 40% larger diameter primary mirror, with almost 8 times the number of
polarization-sensitive detectors resulting in a factor of 16 increase in
mapping speed. With a spatial resolution of 22 arcseconds and four times the
field of view of BLASTPol, BLAST-TNG will bridge the angular scales between
Planck's low resolution all-sky maps and ALMA's ultra-high resolution narrow
fields. The new receiver has a larger cryogenics volume, allowing for a 28 day
hold time. BLAST-TNG employs three arrays of Microwave Kinetic Inductance
Detectors (MKIDs) with 30% fractional bandwidth at 250, 350 and 500 microns. In
this paper, we will present the new BLAST-TNG instrument and science
objectives.
[18]
oai:arXiv.org:1308.0235 [pdf] - 857218
The Detector System for the Stratospheric Kinetic Inductance Polarimeter
(SKIP)
Johnson, B. R.;
Ade, P. A. R.;
Araujo, D.;
Bradford, K. J.;
Chapman, D.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C.;
Hillbrand, S.;
Jones, G.;
Limon, M.;
Mauskopf, P.;
McCarrick, H.;
Miller, A.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2013-08-01, last modified: 2014-01-05
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed
balloon-borne experiment designed to study the cosmic microwave background, the
cosmic infrared background and Galactic dust emission by observing 1133 square
degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden.
The instrument contains 2317 single-polarization, horn-coupled, aluminum
lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be
maintained at 100 mK with an adiabatic demagnetization refrigerator. The
polarimeter operates in two configurations, one sensitive to a spectral band
centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The
detector readout system is based on the ROACH-1 board, and the detectors will
be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone
telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To
minimize detector loading and maximize sensitivity, the entire optical system
will be cooled to 1 K. Linearly polarized sky signals will be modulated with a
metal-mesh half-wave plate that is mounted at the telescope aperture and
rotated by a superconducting magnetic bearing. The observation program consists
of at least two, five-day flights beginning with the 150 GHz observations.
[19]
oai:arXiv.org:1007.3672 [pdf] - 1033814
EBEX: A balloon-borne CMB polarization experiment
Reichborn-Kjennerud, Britt;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Françcois;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Cantalupo, Christopher;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, William;
Hanany, Shaul;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Leach, Sam;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Meng, Xiaofan;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Polsgrove, Daniel;
Ponthieu, Nicolas;
Raach, Kate;
Sagiv, Ilan;
Smecher, Graeme;
Stivoli, Federico;
Stompor, Radek;
Tran, Huan;
Tristram, Matthieu;
Tucker, Gregory S.;
Vinokurov, Yury;
Yadav, Amit;
Zaldarriaga, Matias;
Zilic, Kyle
Submitted: 2010-07-21
EBEX is a NASA-funded balloon-borne experiment designed to measure the
polarization of the cosmic microwave background (CMB). Observations will be
made using 1432 transition edge sensor (TES) bolometric detectors read out with
frequency multiplexed SQuIDs. EBEX will observe in three frequency bands
centered at 150, 250, and 410 GHz, with 768, 384, and 280 detectors in each
band, respectively. This broad frequency coverage is designed to provide
valuable information about polarized foreground signals from dust. The
polarized sky signals will be modulated with an achromatic half wave plate
(AHWP) rotating on a superconducting magnetic bearing (SMB) and analyzed with a
fixed wire grid polarizer. EBEX will observe a patch covering ~1% of the sky
with 8' resolution, allowing for observation of the angular power spectrum from
\ell = 20 to 1000. This will allow EBEX to search for both the primordial
B-mode signal predicted by inflation and the anticipated lensing B-mode signal.
Calculations to predict EBEX constraints on r using expected noise levels show
that, for a likelihood centered around zero and with negligible foregrounds,
99% of the area falls below r = 0.035. This value increases by a factor of 1.6
after a process of foreground subtraction. This estimate does not include
systematic uncertainties. An engineering flight was launched in June, 2009,
from Ft. Sumner, NM, and the long duration science flight in Antarctica is
planned for 2011. These proceedings describe the EBEX instrument and the North
American engineering flight.
[20]
oai:arXiv.org:1006.5256 [pdf] - 229058
Software systems for operation, control, and monitoring of the EBEX
instrument
Milligan, Michael;
Ade, Peter;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Cantalupo, Christopher;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Leach, Sam;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber;
Pascale, Enzo;
Polsgrove, Daniel;
Ponthieu, Nicolas;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tran, Huan;
Tucker, Gregory S.;
Vinokurov, Yury;
Yadav, Amit;
Zaldarriaga, Matias;
Zilic, Kyle
Submitted: 2010-06-27, last modified: 2010-07-05
We present the hardware and software systems implementing autonomous
operation, distributed real-time monitoring, and control for the EBEX
instrument. EBEX is a NASA-funded balloon-borne microwave polarimeter designed
for a 14 day Antarctic flight that circumnavigates the pole. To meet its
science goals the EBEX instrument autonomously executes several tasks in
parallel: it collects attitude data and maintains pointing control in order to
adhere to an observing schedule; tunes and operates up to 1920 TES bolometers
and 120 SQUID amplifiers controlled by as many as 30 embedded computers;
coordinates and dispatches jobs across an onboard computer network to manage
this detector readout system; logs over 3~GiB/hour of science and housekeeping
data to an onboard disk storage array; responds to a variety of commands and
exogenous events; and downlinks multiple heterogeneous data streams
representing a selected subset of the total logged data. Most of the systems
implementing these functions have been tested during a recent engineering
flight of the payload, and have proven to meet the target requirements. The
EBEX ground segment couples uplink and downlink hardware to a client-server
software stack, enabling real-time monitoring and command responsibility to be
distributed across the public internet or other standard computer networks.
Using the emerging dirfile standard as a uniform intermediate data format, a
variety of front end programs provide access to different components and views
of the downlinked data products. This distributed architecture was demonstrated
operating across multiple widely dispersed sites prior to and during the EBEX
engineering flight.
[21]
oai:arXiv.org:1005.3339 [pdf] - 168465
The EBEX Cryostat and Supporting Electronics
Sagiv, Ilan;
Aboobaker, Asad M.;
Bao, Chaoyun;
Hanany, Shaul;
Jones, Terry;
Klein, Jeffrey;
Milligan, Michael;
Polsgrove, Daniel E.;
Raach, Kate;
Zilic, Kyle;
Korotkov, Andrei;
Tucker, Gregory S.;
Vinukurov, Yuri;
Matsumura, Tomotake;
Ade, Peter;
Grainger, Will;
Pascale, Enzo;
Chapman, Daniel;
Didier, Joy;
Hillbrand, Seth;
Reichborn-Kjennerud, Britt;
Limon, Michele;
Miller, Amber;
Jaffe, Andrew;
Yadav, Amit;
Zaldarriaga, Matias;
Ponthieu, Nicolas;
Tristram, Matthieu;
Borrill, Julian;
Cantalupo, Christopher;
Kisner, Ted;
Aubin, Francois;
Dobbs, Matt;
MacDermid, Kevin;
Hilton, Gene;
Hubmayr, Johhannes;
Irwin, Kent;
Reintsema, Carl;
Baccigalupi, Carlo;
Leach, Sam;
Johnson, Bradley;
Lee, Adrian;
Tran, Huan;
Levinson, Lorne
Submitted: 2010-05-18
We describe the cryostat and supporting electronics for the EBEX experiment.
EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization
of the cosmic microwave background radiation. The instrument includes a 1.5
meter Gregorian-type telescope and 1432 bolometric transition edge sensor
detectors operating at 0.3 K. Electronics for monitoring temperatures and
controlling cryostat refrigerators is read out over CANbus. A timing system
ensures the data from all subsystems is accurately synchronized. EBEX completed
an engineering test flight in June 2009 during which the cryogenics and
supporting electronics performed according to predictions. The temperatures of
the cryostat were stable, and an analysis of a subset of the data finds no scan
synchronous signal in the cryostat temperatures. Preparations are underway for
an Antarctic flight.