Normalized to: Hijmering, R.
[1]
oai:arXiv.org:1807.06423 [pdf] - 1718603
The SAFARI Detector System
Audley, Michael D.;
de Lange, Gert;
Gao, Jian-Rong;
Jackson, Brian D.;
Hijmering, Richard A.;
Ridder, Marcel L.;
Bruijn, Marcel P.;
Roelfsema, Peter R.;
Ade, Peter A. R.;
Withington, Stafford;
Bradford, Charles M.;
Trappe, Neal A.
Submitted: 2018-07-17, last modified: 2018-07-18
We give an overview of the baseline detector system for SAFARI, the prime
focal-plane instrument on board the proposed space infrared observatory, SPICA.
SAFARI's detectors are based on superconducting Transition Edge Sensors (TES)
to provide the extreme sensitivity (dark NEP$\le2\times10^{-19}\rm\ W/\sqrt
Hz$) needed to take advantage of SPICA's cold (<8 K) telescope. In order to
read out the total of ~3500 detectors we use frequency domain multiplexing
(FDM) with baseband feedback. In each multiplexing channel, a two-stage SQUID
preamplifier reads out 160 detectors. We describe the detector system and
discuss some of the considerations that informed its design.
[2]
oai:arXiv.org:1803.10438 [pdf] - 1747876
SPICA - a large cryogenic infrared space telescope Unveiling the
obscured Universe
Roelfsema, P. R.;
Shibai, H.;
Armus, L.;
Arrazola, D.;
Audard, M.;
Audley, M. D.;
Bradford, C. M.;
Charles, I.;
Dieleman, P.;
Doi, Y.;
Duband, L.;
Eggens, M.;
Evers, J.;
Funaki, I.;
Gao, J. R.;
Giard, M.;
Fernández, A. di Giorgio L. M. González;
Griffin, M.;
Helmich, F. P.;
Hijmering, R.;
Huisman, R.;
Ishihara, D.;
Isobe, N.;
Jackson, B.;
Jacobs, H.;
Jellema, W.;
Kamp, I.;
Kaneda, H.;
Kawada, M.;
Kemper, F.;
Kerschbaum, F.;
Khosropanah, P.;
Kohno, K.;
Kooijman, P. P.;
Krause, O.;
van der Kuur, J.;
Kwon, J.;
Laauwen, W. M.;
de Lange, G.;
Larsson, B.;
van Loon, D.;
Madden, S. C.;
Matsuhara, H.;
Najarro, F.;
Nakagawa, T.;
Naylor, D.;
Ogawa, H.;
Onaka, T.;
Oyabu, S.;
Poglitsch, A.;
Reveret, V.;
Rodriguez, L.;
Spinoglio, L.;
Sakon, I.;
Sato, Y.;
Shinozaki, K.;
Shipman, R.;
Sugita, H.;
Suzuki, T.;
van der Tak, F. F. S.;
Redondo, J. Torres;
Wada, T.;
Wang, S. Y.;
Wafelbakker, C. K.;
van Weers, H.;
Withington, S.;
Vandenbussche, B.;
Yamada, T.;
Yamamura, I.
Submitted: 2018-03-28
Measurements in the infrared wavelength domain allow us to assess directly
the physical state and energy balance of cool matter in space, thus enabling
the detailed study of the various processes that govern the formation and early
evolution of stars and planetary systems in galaxies over cosmic time. Previous
infrared missions, from IRAS to Herschel, have revealed a great deal about the
obscured Universe, but sensitivity has been limited because up to now it has
not been possible to fly a telescope that is both large and cold.
SPICA is a mission concept aimed at taking the next step in mid- and
far-infrared observational capability by combining a large and cold telescope
with instruments employing state-of-the-art ultra-sensitive detectors. The
mission concept foresees a 2.5-meter diameter telescope cooled to below 8 K.
With cooling provided by mechanical coolers instead of depending on a limited
cryogen supply, the mission lifetime can extend significantly beyond the
required three years.
SPICA offers instrumentation with spectral resolving powers ranging from R
~50 through 11000 in the 17-230 $\mu$m domain as well as R~28.000 spectroscopy
between 12 and 18 $\mu$m. Additionally SPICA will provide efficient 30-37
$\mu$m broad band mapping, and polarimetric imaging in the 100-350 $\mu$m
range. SPICA will provide unprecedented spectroscopic sensitivity of ~5 x
$10^{-20}$ W/m$^2$ (5$\sigma$/1hr) - at least two orders of magnitude
improvement over what has been attained to date.
With this exceptional leap in performance, new domains in infrared astronomy
will become accessible, allowing us, for example, to unravel definitively
galaxy evolution and metal production over cosmic time, to study dust formation
and evolution from very early epochs onwards, and to trace the formation
history of planetary systems.
[3]
oai:arXiv.org:1608.06843 [pdf] - 1462591
Optical performance of prototype horn-coupled TES bolometer arrays for
SAFARI
Submitted: 2016-08-24
The SAFARI Detector Test Facility is an ultra-low background optical testbed
for characterizing ultra-sensitive prototype horn-coupled TES bolmeters for
SAFARI, the grating spectrometer on board the proposed SPICA satellite. The
testbed contains internal cold and hot black-body illuminators and a light-pipe
for illumination with an external source. We have added reimaging optics to
facilitate array optical measurements. The system is now being used for optical
testing of prototype detector arrays read out with frequency-domain
multiplexing. We present our latest optical measurements of prototype arrays
and discuss these in terms of the instrument performance.
[4]
oai:arXiv.org:1604.02593 [pdf] - 1388308
AC bias characterization of low noise bolometers for SAFARI using an
Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5
MHz
Gottardi, Luciano;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
de Korte, Piet;
van der Kuur, Jan;
Lindeman, Mark;
Ridder, Marcel
Submitted: 2016-04-09
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the
ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on
board of the Japanese space mission SPICA. The FDM prototype of the instrument
requires critical and complex optimizations. For single pixel characterization
under AC bias we are developing a simple FDM system working in the frequency
range from 1 to 5 MHz, based on the open loop read-out of a linearized
two-stage SQUID amplifier and high Q lithographic LC resonators. We describe
the details of the experimental set-up required to achieve low power loading (<
1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We
conclude the paper by comparing the performance of a $4 \cdot 10^{-19}
W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
[5]
oai:arXiv.org:1604.02600 [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and
microcalorimeters
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
van der Kuur, Jan;
van der Linden, Anoton;
Lindeman, Marcel;
Ridder, Marcel
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the
read-out of the TES-based detector array for the future infrared and X-ray
space mission. We describe the performances of a multiplexer designed to
increase the experimental throughput in the characterisation of ultra-low noise
equivalent power (NEP) TES bolometers and high energy resolving power X-ray
microcalorimeters arrays under ac and dc bias. We discuss the results obtained
using the TiAu TES bolometers array fabricated at SRON with measured dark NEP
below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[6]
oai:arXiv.org:1604.00680 [pdf] - 1384872
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
Kozorezov, Alex;
van der Kuur, Jan;
van der Linden, Anton;
Ridder, Marcel
Submitted: 2016-04-03
It has been recently demonstrated that superconducting transition edge
sensors (TESs) behave as weak-links due to longitudinally induced
superconductivity from the leads with higher Tc. In this work we study the
implication of this behaviour for TES-based bolometers and microcalorimeter
under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a
Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier
and high- Q lithographically made superconducting LC resonators. In particular,
we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent
Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short
wavelength band for the instrument SAFARI on the SPICA telescope.
[7]
oai:arXiv.org:1603.07944 [pdf] - 1388264
Optical performance of an ultra-sensitive horn-coupled
transition-edge-sensor bolometer with hemispherical backshort in the far
infrared
Audley, Michael D.;
de Lange, Gert;
Gao, Jian-Rong;
Khosropanah, Pourya;
Hijmering, Richard;
Ridder, Marcel;
Mauskopf, Philip D.;
Morozov, Dmitry;
Trappe, Neil A.;
Doherty, Stephen
Submitted: 2016-03-25
The next generation of far infrared space observatories will require
extremely sensitive detectors that can be realized only by combining extremely
low intrinsic noise with high optical efficiency. We have measured the
broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\
aW/\sqrt Hz$) in the 30--60-$\mu\rm m$ band where radiation is coupled to the
detectors with a few-moded conical feedhorn and a hemispherical backshort. We
show that these detectors have an optical efficiency of 60% (the ratio of the
power detected by the TES bolometer to the total power propagating through the
feedhorn). We find that the measured optical efficiency can be understood in
terms of the modes propagating through the feedhorn with the aid of a spatial
mode-filtering technique.
[8]
oai:arXiv.org:0911.0313 [pdf] - 1018177
First results of a cryogenic optical photon counting imaging
spectrometer using a DROID array
Submitted: 2009-11-02
Context. In this paper we present the first system test in which we
demonstrate the concept of using an array of Distributed Read Out Imaging
Devices (DROIDs) for optical photon detection. Aims. After the successful S-Cam
3 detector the next step in the development of a cryogenic optical photon
counting imaging spectrometer under the S-Cam project is to increase the field
of view using DROIDs. With this modification the field of view of the camera
has been increased by a factor of 5 in area, while keeping the number of
readout channels the same. Methods. The test has been performed using the
flexible S-Cam 3 system and exchanging the 10x12 Superconducting Tunnel
Junction array for a 3x20 DROID array. The extra data reduction needed with
DROIDs is performed offline. Results. We show that, although the responsivity
(number of tunnelled quasiparticles per unit of absorbed photon energy, e- /eV)
of the current array is too low for direct astronomical applications, the
imaging quality is already good enough for pattern detection, and will improve
further with increasing responsivity. Conclusions. The obtained knowledge can
be used to optimise the system for the use of DROIDs.