Normalized to: Hieda, K.
[1]
oai:arXiv.org:1406.0502 [pdf] - 869600
Search for bosonic superweakly interacting massive dark matter particles
with the XMASS-I detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Ichimura, K.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-06-02, last modified: 2014-08-21
Bosonic superweakly interacting massive particles (super-WIMPs) are a
candidate for warm dark matter. With the absorption of such a boson by a xenon
atom these dark matter candidates would deposit an energy equivalent to their
rest mass in the detector. This is the first direct detection experiment
exploring the vector super-WIMPs in the mass range between 40 and 120 keV.
Using 165.9 days of data no significant excess above background was observed in
the fiducial mass of 41 kg. The present limit for the vector super-WIMPs
excludes the possibility that such particles constitute all of dark matter. The
absence of a signal also provides the most stringent direct constraint on the
coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented
sensitivity was achieved exploiting the low background at a level $10^{-4}$
kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
[2]
oai:arXiv.org:1401.4737 [pdf] - 1425198
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from
the XMASS-I experiment
Uchida, H.;
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-01-19, last modified: 2014-04-29
A search for inelastic scattering of Weakly Interacting Massive Particles
(WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase
liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted
volume containing 41 kg of LXe at the very center of our detector we observed
no significant excess of events in 165.9 days of data. Our background reduction
allowed us to derive our limits without explicitly subtracting the remaining
events which are compatible with background expectations and derive for e.g. a
50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei
of 3.2 pb at the 90% confidence level.
[3]
oai:arXiv.org:1212.6153 [pdf] - 753387
Search for solar axions in XMASS, a large liquid-xenon detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Suzuki, A. Shinozaki Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2012-12-26, last modified: 2013-05-29
XMASS, a low-background, large liquid-xenon detector, was used to search for
solar axions that would be produced by bremsstrahlung and Compton effects in
the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent
limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$
(90% C.L.), which is a factor of two stronger than the existing experimental
limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are
1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced
the most stringent limit, which is better than that previously derived from
astrophysical arguments regarding the Sun to date.
[4]
oai:arXiv.org:1211.5404 [pdf] - 620998
Light WIMP search in XMASS
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Suzuki, A. Shinozaki Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2012-11-22, last modified: 2013-01-16
A search for light dark matter using low-threshold data from the single phase
liquid xenon scintillation detector XMASS, has been conducted. Using the entire
835 kg inner volume as target, the analysis threshold can be lowered to 0.3
keVee (electron-equivalent) to search for light dark matter. With low-threshold
data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and
without discriminating between nuclear-recoil and electronic events, XMASS
excludes part of the parameter space favored by other experiments.
[5]
oai:arXiv.org:1301.2815 [pdf] - 831840
XMASS detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Nishiie, H.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Nishitani, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2013-01-13
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar
neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon.
The first phase of the XMASS experiment searches for dark matter. In this
paper, we describe the XMASS detector in detail, including its configuration,
data acquisition equipment and calibration system.