Normalized to: Herve, S.
[1]
oai:arXiv.org:1006.3098 [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark
Matter searches
Kozlov, V. Yu.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X. -F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number
of low count rate experiments, namely direct searches for Dark Matter. In this
work we describe a neutron detector to measure this background in an
underground laboratory, the Laboratoire Souterrain de Modane. The system is
based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of
the EDELWEISS-II experiment for coincident muon detection. The system was
installed in autumn 2008 and passed since then a number of commissioning tests
proving its full functionality. The data-taking is continuously ongoing and a
count rate of the order of 1 muon-induced neutron per day has been achieved.
[2]
oai:arXiv.org:0912.0805 [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic
detectors with interleaved electrodes
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X-F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.;
Collaboration, the EDELWEISS
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark
matter with an array of ten 400 g heat-and-ionization cryogenic detectors
equipped with interleaved electrodes for the rejection of near-surface events.
Six months of continuous operation at the Laboratoire Souterrain de Modane have
been achieved. The observation of one nuclear recoil candidate above 20 keV in
an effective exposure of 144 kgd is interpreted in terms of limits on the
cross-section of spin-independent interactions of WIMPs and nucleons. A
cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80
GeV/c2. This result demonstrates for the first time the very high background
rejection capabilities of these simple and robust detectors in an actual WIMP
search experiment.
[3]
oai:arXiv.org:0905.0753 [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Broniatowski, A.;
Defay, X.;
Armengaud, E.;
Berge, L.;
Benoit, A.;
Besida, O.;
Blumer, J.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrache, C.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M. -A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is
presented, taking advantage of the coplanar grid technique of event
localisation for improved background discrimination. Experiments performed with
prototype devices in the EDELWEISS II setup at the Modane underground facility
demonstrate the remarkably high efficiency of these devices for the rejection
of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate
the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as
proposed in the EURECA project of a one-ton cryogenic detector mass.
[4]
oai:arXiv.org:astro-ph/0503265 [pdf] - 71647
Final results of the EDELWEISS-I dark matter search with cryogenic
heat-and-ionization Ge detectors
Sanglard, V.;
Benoit, A.;
Berge, L.;
Blumer, J.;
Broniatowski, A.;
Censier, B.;
Chabert, L.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
Collin, S.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Drain, D.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Fiorucci, S.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Herve, S.;
Horn, M.;
Juillard, A.;
Karolak, M.;
Kikuchi, C.;
de Lesquen, A.;
Luca, M.;
Mallet, J.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Schoeffel, L.;
Stern, M.;
Vagneron, L.;
Villar, V.
Submitted: 2005-03-11, last modified: 2005-05-26
The final results of the EDELWEISS-I dark matter search using cryogenic
heat-and-ionization Ge detectors are presented. The final data sample
corresponds to an increase by a factor five in exposure relative to the
previously published results. A recoil energy threshold of 13 keV or better was
achieved with three 320g detectors working simultaneously over four months of
stable operation. Limits on the spin-independent cross-section for the
scattering of a WIMP on a nucleon are derived from an accumulated fiducial
exposure of 62 kg.d.
[5]
oai:arXiv.org:astro-ph/0310657 [pdf] - 60320
Calibration of the EDELWEISS Cryogenic Heat-and-ionisation Germanium
Detectors for Dark Matter Search
The EDELWEISS Collaboration;
Martineau, O.;
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chabert, L.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Mirabolfathi, N.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Riccio, C.;
Sanglard, V.;
Schoeffel, L.;
Stern, M.;
Vagneron, L.
Submitted: 2003-10-22
Several aspects of the analysis of the data obtained with the cryogenic
heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search
experiment are presented. Their calibration, the determination of their energy
threshold, fiducial volume and nuclear recoil acceptance are detailed.
[6]
oai:arXiv.org:astro-ph/0206271 [pdf] - 49902
Improved Exclusion Limits from the EDELWEISS WIMP Search
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chabert, L.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Riccio, C.;
Sanglard, V.;
Stern, M.;
Vagneron, L.
Submitted: 2002-06-17
The EDELWEISS experiment has improved its sensitivity for the direct search
for WIMP dark matter. In the recoil energy range relevant for WIMP masses below
10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a
heat-and-ionization cryogenic Ge detector operated in the low-background
environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel,
during an effective exposure of 7.4 kg.days. This result is combined with the
previous EDELWEISS data to derive a limit on the cross-section for
spin-independent interaction of WIMPs and nucleons as a function of WIMP mass,
using standard nuclear physics and astrophysical assumptions. This limit
excludes at more than 99.8%CL a WIMP candidate with a mass of 44 GeV/c2 and a
cross-section of 5.4 x 10-6 pb, as reported by the DAMA collaboration. A first
sample of supersymmetric models are also excluded at 90%CL.
[7]
oai:arXiv.org:astro-ph/0205023 [pdf] - 49097
320g Ionization-Heat Cryogenic Detector for Dark Matter Search in the
EDELWEISS Experiment
Martineau, O.;
Chapellier, M.;
Chardin, G.;
De Jesus, M.;
Gascon, J.;
Herve, S.;
Juillard, A.;
Loidl, M.;
Navick, X-F.;
Nollez, G.
Submitted: 2002-05-02
The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge
detector operated in a low-background environment in the Laboratoire Souterrain
de Modane for direct WIMP detection. This detector presents an increase of more
than 4 times the mass of previous detectors. Calibrations of this detector are
used to determine its energy resolution and fiducial volume, and to optimize
the detector design for the 1kg phase of the EDELWEISS-I experiment. Analysis
of the calibrations and characteristics of a first series of 320g-detectors are
presented.
[8]
oai:arXiv.org:astro-ph/0101204 [pdf] - 1507854
Dark Matter Search in the Edelweiss Experiment
Chapellier, M.;
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Simon, E.;
Stern, M.;
Vagneron, L.
Submitted: 2001-01-12, last modified: 2001-02-23
Preliminary results obtained with 320g bolometers with simultaneous
ionization and heat measurements are described. After a few weeks of data
taking, data accumulated with one of these detectors are beginning to exclude
the upper part of the DAMA region. Prospects for the present run and the second
stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat
allowing data taking with 100 detectors, are briefly described.