Normalized to: Herriot, G.
[1]
oai:arXiv.org:1908.04504 [pdf] - 1938632
Geometric Distortion Calibration with Photo-lithographic Pinhole Masks
for High-Precision Astrometry
Submitted: 2019-08-13
Adaptive optics (AO) systems deliver high-resolution images that may be ideal
for precisely measuring positions of stars (i.e. astrometry) if the system has
stable and well-calibrated geometric optical distortions. A calibration unit,
equipped with back-illuminated pinhole mask, can be utilized to measure
instrumental optical distortions. AO systems on the largest ground-based
telescopes, such as the W. M. Keck Observatory and the Thirty Meter Telescope
require pinhole positions known to 20 nm to achieve an astrometric precision of
0.001 of a resolution element. We characterize a photo-lithographic pinhole
mask and explore the systematic errors that result from different experimental
setups. We characterized the nonlinear geometric distortion of a simple imaging
system using the mask; and we measured 857 nm RMS of optical distortion with a
final residual of 39 nm (equivalent to 20 {\mu}as for TMT). We use a sixth
order bivariate Legendre polynomial to model the optical distortion and allow
the reference positions of the individual pinholes to vary. The nonlinear
deviations in the pinhole pattern with respect to the manufacturing design of a
square pattern are 47.2 nm +/- 4.5 nm (random) +/- 10.8 nm (systematic) over an
area of 1788 mm$^2$. These deviations reflect the additional error induced when
assuming the pinhole mask is manufactured perfectly square. We also find that
ordered mask distortions are significantly more difficult to characterize than
random mask distortions as the ordered distortions can alias into optical
camera distortion. Future design simulations for astrometric calibration units
should include ordered mask distortions. We conclude that photo-lithographic
pinhole masks are >10 times better than the pinhole masks deployed in first
generation AO systems and are sufficient to meet the distortion calibration
requirements for the upcoming thirty meter class telescopes.
[2]
oai:arXiv.org:1809.05538 [pdf] - 1751086
Multi-Conjugate Adaptive Optics Simulator for the Thirty Meter
Telescope: Design, Implementation, and Results
Submitted: 2018-09-14
We present a multi-conjugate adaptive optics (MCAO) system simulator bench,
HeNOS (Herzberg NFIRAOS Optical Simulator). HeNOS is developed to validate the
performance of the MCAO system for the Thirty Meter Telescope, as well as to
demonstrate techniques critical for future AO developments. In this paper, we
focus on describing the derivations of parameters that scale the 30-m telescope
AO system down to a bench experiment and explain how these parameters are
practically implemented on an optical bench. While referring other papers for
details of AO technique developments using HeNOS, we introduce the
functionality of HeNOS, in particular, three different single-conjugate AO
modes that HeNOS currently offers: a laser guide star AO with a Shack-Hartmann
wavefront sensor, a natural guide star AO with a pyramid wavefront sensor, and
a laser guide star AO with a sodium spot elongation on the Shack-Hartmann
corrected by a truth wavefront sensing on a natural guide star. Laser
tomography AO and ultimate MCAO are being prepared to be implemented in the
near future.
[3]
oai:arXiv.org:1808.07504 [pdf] - 1737992
The Infrared Imaging Spectrograph (IRIS) for TMT: closed-loop adaptive
optics while dithering
Chapin, Edward L.;
Dunn, Jennifer;
Andersen, David;
Herriot, Glen;
Kerley, Dan;
Nakamoto, Takashi;
Johnson, Jimmy;
Wang, Lianqi;
Trancho, Gelys;
Chisholm, Eric;
Ellerbroek, Brent;
Gillies, Kim;
Hayano, Yutaka;
Larkin, James;
Simard, Luc;
Sirota, Mark;
Suzuki, Ryuji;
Weber, Bob;
Wright, Shelley;
Zhang, Kai
Submitted: 2018-08-22
The InfraRed Imaging Spectrograph (IRIS) is the first-light client instrument
for the Narrow Field Infrared Adaptive Optics System (NFIRAOS) on the Thirty
Meter Telescope (TMT). IRIS includes three natural guide star (NGS)
On-Instrument Wavefront Sensors (OIWFS) to measure tip/tilt and focus errors in
the instrument focal plane. NFIRAOS also has an internal natural guide star
wavefront sensor, and IRIS and NFIRAOS must precisely coordinate the motions of
their wavefront sensor positioners to track the locations of NGSs while the
telescope is dithering (offsetting the telescope to cover more area), to avoid
a costly re-acquisition time penalty. First, we present an overview of the
sequencing strategy for all of the involved subsystems. We then predict the
motion of the telescope during dithers based on finite-element models provided
by TMT, and finally analyze latency and jitter issues affecting the propagation
of position demands from the telescope control system to individual motor
controllers.
[4]
oai:arXiv.org:1608.01693 [pdf] - 1531195
Flowdown of the TMT astrometry error budget(s) to the IRIS design
Schoeck, Matthias;
Andersen, David;
Rogers, John;
Ellerbroek, Brent;
Chisholm, Eric;
Dunn, Jennifer;
Herriot, Glen;
Larkin, James;
Moore, Anna;
Suzuki, Ryuji;
Wincentsen, James;
Wright, Shelley
Submitted: 2016-08-04
TMT has defined the accuracy to be achieved for both absolute and
differential astrometry in its top-level requirements documents. Because of the
complexities of different types of astrometric observations, these requirements
cannot be used to specify system design parameters directly. The TMT astrometry
working group therefore developed detailed astrometry error budgets for a
variety of science cases. These error budgets detail how astrometric errors
propagate through the calibration, observing and data reduction processes. The
budgets need to be condensed into sets of specific requirements that can be
used by each subsystem team for design purposes. We show how this flowdown from
error budgets to design requirements is achieved for the case of TMT's
first-light Infrared Imaging Spectrometer (IRIS) instrument.
[5]
oai:arXiv.org:1608.01680 [pdf] - 1457560
The Infrared Imaging Spectrograph (IRIS) for TMT: Multi-tiered Wavefront
Measurements and Novel Mechanical Design
Dunn, Jennifer;
Andersen, David;
Chapin, Edward;
Reshetov, Vlad;
Wierzbicki, Ramunas;
Herriot, Glen;
Chalmers, Dean;
Isbrucker, Victor;
Larkin, James E.;
Moore, Anna M.;
Suzuki, Ryuji
Submitted: 2016-08-04
The InfraRed Imaging Spectrograph (IRIS) will be the first light adaptive
optics instrument on the Thirty Meter Telescope (TMT). IRIS is being built by a
collaboration between Caltech, the University of California, NAOJ and NRC
Herzberg. We present novel aspects of the Support Structure, Rotator and
On-Instrument Wavefront Sensor systems being developed at NRC Herzberg. IRIS is
suspended from the bottom port of the Narrow Field Infrared Adaptive Optics
System (NFIRAOS), and provides its own image de-rotation to compensate for
sidereal rotation of the focal plane. This arrangement is a challenge because
NFIRAOS is designed to host two other science instruments, which imposes strict
mass requirements on IRIS. We have been tasked with keeping the instrument mass
under seven tonnes which has resulted in a mass reduction of 30 percent for the
support structure and rotator compared to the most recent IRIS designs. To
accomplish this goal, while still being able to withstand earthquakes, we
developed a new design with composite materials. As IRIS is a client instrument
of NFIRAOS, it benefits from NFIRAOS's superior AO correction. IRIS assists
this correction by sensing low-order aberrations with an On-Instrument
Wavefront Sensor (OIWFS). The OIWFS consists of three independently positioned
natural guide star wavefront sensors that patrol a 2-arcminute field of view.
We expect tip-tilt measurements from faint stars within the IRIS imager focal
plane will further stabilize the delivered image quality. We describe how the
use of On-Detector Guide Windows (ODGWs) in the IRIS imager can be incorporated
into the AO correction. Finally, we present our strategies for acquiring and
tracking sources with this complex AO system, and for mitigating and measuring
the various potential sources of image blur and misalignment due to properties
of the mechanical structure and interfaces. (Abridged)
[6]
oai:arXiv.org:1408.4406 [pdf] - 1216393
NFIRAOS First Facility AO System for the Thirty Meter Telescope
Herriot, Glen;
Andersen, David;
Atwood, Jenny;
Boyer, Corinne;
Byrnes, Peter;
Caputa, Kris;
Ellerbroek, Brent;
Gilles, Luc;
Hill, Alexis;
Ljusic, Zoran;
Pazder, John;
Rosensteiner, Matthias;
Smith, Malcolm;
Spano, Paolo;
Szeto, Kei;
Véran, Jean-Pierre;
Wevers, Ivan;
Wang, Lianqi;
Wooff, Robert
Submitted: 2014-08-19
NFIRAOS, the Thirty Meter Telescope's first adaptive optics system is an
order 60x60 Multi-Conjugate AO system with two deformable mirrors. Although
most observing will use 6 laser guide stars, it also has an NGS-only mode.
Uniquely, NFIRAOS is cooled to -30 C to reduce thermal background. NFIRAOS
delivers a 2-arcminute beam to three client instruments, and relies on up to
three IR WFSs in each instrument. We present recent work including: robust
automated acquisition on these IR WFSs; trade-off studies for a common-size of
deformable mirror; real-time computing architectures; simplified designs for
high-order NGS-mode wavefront sensing; modest upgrade concepts for
high-contrast imaging.
[7]
oai:arXiv.org:1407.2995 [pdf] - 1215601
The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview
Moore, Anna M.;
Larkin, James E.;
Wright, Shelley A.;
Bauman, Brian;
Dunn, Jennifer;
Ellerbroek, Brent;
Phillips, Andrew C.;
Simard, Luc;
Suzuki, Ryuji;
Zhang, Kai;
Aliado, Ted;
Brims, George;
Canfield, John;
Chen, Shaojie;
Dekany, Richard;
Delacroix, Alex;
Do, Tuan;
Herriot, Glen;
Ikenoue, Bungo;
Johnson, Chris;
Meyer, Elliot;
Obuchi, Yoshiyuki;
Pazder, John;
Reshetov, Vladimir;
Riddle, Reed;
Saito, Sakae;
Smith, Roger;
Sohn, Ji Man;
Uraguchi, Fumihiro;
Usuda, Tomonori;
Wang, Eric;
Wang, Lianqi;
Weiss, Jason;
Wooff, Robert
Submitted: 2014-07-10
We present an overview of the design of IRIS, an infrared (0.84 - 2.4 micron)
integral field spectrograph and imaging camera for the Thirty Meter Telescope
(TMT). With extremely low wavefront error (<30 nm) and on-board wavefront
sensors, IRIS will take advantage of the high angular resolution of the narrow
field infrared adaptive optics system (NFIRAOS) to dissect the sky at the
diffraction limit of the 30-meter aperture. With a primary spectral resolution
of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will
create an unparalleled ability to explore high redshift galaxies, the Galactic
center, star forming regions and virtually any astrophysical object. This paper
summarizes the entire design and basic capabilities. Among the design
innovations is the combination of lenslet and slicer integral field units, new
4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared
wavefront sensors, and a very large vacuum cryogenic system.
[8]
oai:arXiv.org:1101.2353 [pdf] - 290277
Using Site Testing Data for Adaptive Optics Simulations
Herriot, Glen;
Andersen, David;
Conan, Rod;
Ellerbroek, Brent;
Gilles, Luc;
Hickson, Paul;
Jackson, Kate;
Lardière, Olivier;
Pfrommer, Thomas;
Véran, Jean-Pierre;
Wang, Lianqi
Submitted: 2011-01-12
Astronomical Site testing data plays a vital role in the simulation, design,
evaluation and operation of adaptive optics systems for large telescope. We
present the example of TMT and its first light facilitiy adaptive optics system
NFIRAOS, and illustrate the many simulations done based on site testing data.
[9]
oai:arXiv.org:astro-ph/0609307 [pdf] - 84899
Temporal variability of the telluric sodium layer
Submitted: 2006-09-11
The temporal variability of the telluric sodium layer is investigated by
analyzing 28 nights of data obtained with the Colorado State University LIDAR
experiment. The mean height power spectrum of the sodium layer was found to be
well fit by a power law over the observed range of frequencies, 10 microhertz
to 4 millhertz. The best fitting power law was found to be 10^\beta \nu^\alpha,
with \alpha = -1.79 +/- 0.02 and \beta = 1.12 +/- 0.40. Applications to
wavefront sensing require knowledge of the behavior of the sodium layer at kHz
frequencies. Direct measurements at these frequencies do not exist.
Extrapolation from low-frequency behavior to high frequencies suggests that
this variability may be a significant source of error for laser-guide-star
adaptive optics on large-aperture telescopes.
[10]
oai:arXiv.org:astro-ph/0312278 [pdf] - 61491
Deep Near-Infrared Imaging of a Field in the Outer Disk of M82 with the
ALTAIR Adaptive Optics System on Gemini North
Submitted: 2003-12-10
Deep H and K' images, recorded with the ALTAIR adaptive optics system and
NIRI imager on Gemini North, are used to probe the red stellar content in a
field with a projected distance of 1 kpc above the disk plane of the starburst
galaxy M82. The data have an angular resolution of 0.08 arcsec FWHM, and
individual AGB and RGB stars are resolved. The AGB extends to at least 1.7 mag
in K above the RGB-tip, which occurs at K = 21.7. The relative numbers of
bright AGB stars and RGB stars are consistent with stellar evolution models,
and one of the brightest AGB stars has an H-K color and K brightness that is
consistent with it being a C star. The brightnesses of the AGB stars suggest
that they formed during intermediate epochs, possibily after the last major
interaction with M81. Therefore, star formation in M82 during intermediate
epochs may not have been restricted to the plane of the disk.