Normalized to: Hennings-Yeomans, R.
[1]
oai:arXiv.org:1908.07642 [pdf] - 2065232
Recent Advances in Frequency-Multiplexed TES Readout: Vastly Reduced
Parasitics and an Increase in Multiplexing Factor with sub-Kelvin SQUIDs
de Haan, T.;
Suzuki, A.;
Boyd, S. T. P.;
Cantor, R. H.;
Coerver, A.;
Dobbs, M. A.;
Hennings-Yeomans, R.;
Holzapfel, W. L.;
Lee, A. T.;
Noble, G. I.;
Smecher, G.;
Zhou, J.
Submitted: 2019-08-20
Cosmic microwave background (CMB) measurements are fundamentally limited by
photon statistics. Therefore, ground-based CMB observatories have been
increasing the number of detectors that are simultaneously observing the sky.
Thanks to the advent of monolithically fabricated transition edge sensor (TES)
arrays, the number of on-sky detectors has been increasing exponentially for
over a decade. The next-generation experiment CMB-S4 will increase this
detector count by more than an order of magnitude from the current
state-of-the-art to ~500,000. The readout of such a huge number of exquisitely
precise sub-Kelvin sensors is feasible using an existing technology:
frequency-domain multiplexing (fMux). To further optimize this system and
reduce complexity and cost, we have recently made significant advances
including the elimination of 4 K electronics, a massive decrease of parasitic
in-series impedances, and a significant increase in multiplexing factor.
[2]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[3]
oai:arXiv.org:1012.5078 [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Razeti, M.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set
acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the
Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis
window was extended to a recoil energy of 150 keV, and an improved
surface-event background-rejection cut was defined to increase the sensitivity
of the experiment to the inelastic dark matter (iDM) model. Three dark matter
candidates were found between 25 keV and 150 keV. The probability to observe
three or more background events in this energy range is 11%. Because of the
occurrence of these events the constraints on the iDM parameter space are
slightly less stringent than those from our previous analysis, which used an
energy window of 10-100 keV.
[4]
oai:arXiv.org:1011.2482 [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter
Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken
between October 2006 and September 2008 using eight germanium detectors are
reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased
sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs)
with masses below ~10 GeV/c^2. This analysis provides stronger constraints than
previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter
space associated with possible low-mass WIMP signals from the DAMA/LIBRA and
CoGeNT experiments.
[5]
oai:arXiv.org:0907.1438 [pdf] - 142195
Analysis of the low-energy electron-recoil spectrum of the CDMS
experiment
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Beaty, J.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Cushman, P.;
DeJongh, F.;
Dragowsky, M. R.;
Duong, L.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fritts, M.;
Golwala, S. R.;
Grant, D. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Mahapatra, R.;
Mandic, V.;
Moore, D.;
McCarthy, K. A.;
Mirabolfathi, N.;
Nelson, H.;
Ogburn, R. W.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Wang, G.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Collaboration, the CDMS
Submitted: 2009-07-09
We report on the analysis of the low-energy electron-recoil spectrum from the
CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis
provides details on the observed counting rate and possible background sources
in the energy range of 2 - 8.5 keV. We find no significant excess in the
counting rate above background, and compare this observation to the recent DAMA
results. In the framework of a conversion of a dark matter particle into
electromagnetic energy, our 90% confidence level upper limit of 0.246
events/kg/day at 3.15 keV is lower than the total rate above background
observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics
model to provide the scaling in cross section between NaI and Ge, we assume a
Z^2 scaling. With this assumption the observed rate in DAMA differs from the
upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the
modulation amplitude is 6% of the total rate we obtain upper limits on the
modulation amplitude a factor of ~2 less than observed by DAMA, constraining
some possible interpretations of this modulation.
[6]
oai:arXiv.org:astro-ph/0611371 [pdf] - 86757
A Neutron Multiplicity Meter for Deep Underground Muon-Induced High
Energy Neutron Measurements
Submitted: 2006-11-12, last modified: 2007-01-23
We present the design of an instrument capable of measuring the high energy
($>$60 MeV) muon-induced neutron flux deep underground. The instrument is based
on applying the Gd-loaded liquid-scintillator technique to measure the rate of
high-energy neutrons underground based on the neutron multiplicity induced in a
Pb target. We present design studies based on Monte Carlo simulations that show
that an apparatus consisting of a Pb target of 200 cm by 200 cm area by 60 cm
thickness covered by a 60 cm thick Gd-loaded liquid scintillator (0.5% Gd
content) detector could measure, at a depth of 2000 meters of water equivalent,
a rate of $70\pm8$ (stat) events/year. Based on these studies, we also discuss
the benefits of using a neutron multiplicity meter as a component of active
shielding in such experiments.
[7]
oai:arXiv.org:astro-ph/0503583 [pdf] - 880834
Beyond the CDMS-II Dark Matter Search: SuperCDMS
Brink, P. L.;
Cabrera, B.;
Chang, C. L.;
Cooley, J.;
Ogburn, R. W.;
Akerib, D. S.;
Bailey, C. N.;
Brusov, P. P.;
Dragowsky, M. R.;
Grant, D. R.;
Hennings-Yeomans, R.;
Schnee, R. W.;
Attisha, M. J.;
Gaitskell, R. J.;
Thompson, J-P. F.;
Baudis, L.;
Saab, T.;
Bauer, D. A.;
Crisler, M. B.;
Holmgren, D.;
Ramberg, E.;
Yoo, J.;
Bunker, R.;
Caldwell, D. O.;
Mahapatra, R.;
Nelson, H.;
Sander, J.;
Yellin, S.;
Cushman, P.;
Duong, L.;
Reisetter, A.;
Denes, P.;
Lu, A.;
Sadoulet, B.;
Filippini, J.;
Meunier, P.;
Mirabolfathi, N.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Golwala, S. R.;
Huber, M. E.;
Irwin, K. D.;
Young, B. A.
Submitted: 2005-03-27
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle
(WIMP) search at the Soudan Underground Laboratory sets the most stringent
exclusion limits of any WIMP cold dark matter direct-detection experiment. To
extend our reach further, to WIMP-nucleon cross sections in the range $10^{-46}
- 10^{-44}$cm$^2$, we propose SuperCDMS, which would take advantage of a very
deep site. One promising site is the recently approved SNOLab facility in
Canada. In this paper we will present our overall plan, identify primary
issues, and set the goals that need to be met prior to embarking upon each
phase of SuperCDMS.