Normalized to: Helson, K.
[1]
oai:arXiv.org:1908.00480 [pdf] - 2032814
The CLASS 150/220 GHz Polarimeter Array: Design, Assembly, and
Characterization
Dahal, Sumit;
Amiri, Mandana;
Appel, John W.;
Bennett, Charles L.;
Corbett, Lance;
Datta, Rahul;
Denis, Kevin;
Essinger-Hileman, Thomas;
Halpern, Mark;
Helson, Kyle;
Hilton, Gene;
Hubmayr, Johannes;
Keller, Benjamin;
Marriage, Tobias;
Nunez, Carolina;
Petroff, Matthew;
Reintsema, Carl;
Rostem, Karwan;
U-Yen, Kongpop;
Wollack, Edward
Submitted: 2019-08-01, last modified: 2020-01-16
We report on the development of a polarization-sensitive dichroic (150/220
GHz) detector array for the Cosmology Large Angular Scale Surveyor (CLASS)
delivered to the telescope site in June 2019. In concert with existing 40 and
90 GHz telescopes, the 150/220 GHz telescope will make observations of the
cosmic microwave background over large angular scales aimed at measuring the
primordial B-mode signal, the optical depth to reionization, and other
fundamental physics and cosmology. The 150/220 GHz focal plane array consists
of three detector modules with 1020 transition edge sensor (TES) bolometers in
total. Each dual-polarization pixel on the focal plane contains four bolometers
to measure the two linear polarization states at 150 and 220 GHz. Light is
coupled through a planar orthomode transducer (OMT) fed by a smooth-walled
feedhorn array made from an aluminum-silicon alloy (CE7). In this work, we
discuss the design, assembly, and in-lab characterization of the 150/220 GHz
detector array. The detectors are photon-noise limited, and we estimate the
total array noise-equivalent power (NEP) to be 2.5 and 4 aW$\sqrt{\mathrm{s}}$
for 150 and 220 GHz arrays, respectively.
[2]
oai:arXiv.org:1810.01962 [pdf] - 1775714
Dielectric Properties of Conductively Loaded Polyimides in the Far
Infrared
Submitted: 2018-08-30, last modified: 2018-10-11
The dielectric properties of selected conductively-loaded polyimide samples
are characterized in microwave through far infrared wavebands. These materials,
belonging to the Vespel\textsuperscript{\textregistered} family, are more
readily formed by direct machining than their ceramic loaded epoxy counterparts
and present an interesting solution for realizing absorptive optical control
structures. Measurements spanning a spectral range from 1 to 600\,${\rm
cm^{-1}}$ (0.03 to 18\,THz) were preformed and used in parametrization of the
media's dielectric function at frequencies below $\approx3\,$THz.
[3]
oai:arXiv.org:1803.01018 [pdf] - 1783724
The EBEX Balloon Borne Experiment - Detectors and Readout
The EBEX Collaboration;
Abitbol, Maximilian;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen M.;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Irwin, Kent;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2018-03-02, last modified: 2018-07-30
EBEX was a long-duration balloon-borne experiment to measure the polarization
of the cosmic microwave background. The experiment had three frequency bands
centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array
of transition edge sensor (TES) bolometers aboard a balloon platform; shortly
after reaching float we operated 504, 342, and 109 TESs at each of the bands,
respectively. We describe the design and characterization of the array and the
readout system. We give the distributions of measured thermal conductances,
normal resistances, and transition temperatures. With the exception of the
thermal conductance at 150 GHz. We measured median low-loop-gain time constants
$\tau_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements
of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz
and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively.
We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the
three bands, respectively. EBEX pioneered the use of the digital version of the
frequency domain multiplexing (FDM) system which multiplexed the bias and
readout of 16 bolometers onto two wires. We present accounting of the measured
noise equivalent power. The median per-detector noise equivalent temperatures
referred to a black body with a temperature of 2.725 K are 400, 920, and 14500
$\mu$K$\sqrt{s}$ for the three bands, respectively. We compare these values to
our pre-flight predictions and to a previous balloon payload, discuss the
sources of excess noise, and the path for a future payload to make full use of
the balloon environment.
[4]
oai:arXiv.org:1807.04167 [pdf] - 1721214
The Cosmology Large Angular Scale Surveyor Receiver Design
Iuliano, Jeffrey;
Eimer, Joseph;
Parker, Lucas;
Rhoades, Gary;
Ali, Aamir;
Appel, John W.;
Bennett, Charles;
Brewer, Michael;
Bustos, Ricardo;
Chuss, David;
Cleary, Joseph;
Couto, Jullianna;
Dahal, Sumit;
Denis, Kevin;
Dünner, Rolando;
Essinger-Hileman, Thomas;
Fluxa, Pedro;
Halpern, Mark;
Harrington, Kathleen;
Helson, Kyle;
Hilton, Gene;
Hinshaw, Gary;
Hubmayr, Johannes;
Karakla, John;
Marriage, Tobias;
Miller, Nathan;
McMahon, Jeffrey John;
Nuñez, Carolina;
Padilla, Ivan;
Palma, Gonzalo;
Petroff, Matthew;
Márquez, Bastian Pradenas;
Reeves, Rodrigo;
Reintsema, Carl;
Rostem, Karwan;
Valle, Deniz Augusto Nunes;
Van Engelhoven, Trevor;
Wang, Bingjie;
Wang, Qinan;
Watts, Duncan;
Weiland, Jenet;
Wollack, Edward J.;
Xu, Zhilei;
Yan, Ziang;
Zeng, Lingzhen
Submitted: 2018-07-11, last modified: 2018-07-23
The Cosmology Large Angular Scale Surveyor consists of four instruments
performing a CMB polarization survey. Currently, the 40 GHz and first 90 GHz
instruments are deployed and observing, with the second 90 GHz and a
multichroic 150/220 GHz instrument to follow. The receiver is a central
component of each instrument's design and functionality. This paper describes
the CLASS receiver design, using the first 90 GHz receiver as a primary
reference. Cryogenic cooling and filters maintain a cold, low-noise environment
for the detectors. We have achieved receiver detector temperatures below 50 mK
in the 40 GHz instrument for 85% of the initial 1.5 years of operation, and
observed in-band efficiency that is consistent with pre-deployment estimates.
At 90 GHz, less than 26% of in-band power is lost to the filters and lenses in
the receiver, allowing for high optical efficiency. We discuss the mounting
scheme for the filters and lenses, the alignment of the cold optics and
detectors, stray light control, and magnetic shielding.
[5]
oai:arXiv.org:1807.03927 [pdf] - 1714397
Design and characterization of the Cosmology Large Angular Scale
Surveyor (CLASS) 93 GHz focal plane
Dahal, Sumit;
Ali, Aamir;
Appel, John W.;
Essinger-Hileman, Thomas;
Bennett, Charles;
Brewer, Michael;
Bustos, Ricardo;
Chan, Manwei;
Chuss, David T.;
Cleary, Joseph;
Colazo, Felipe;
Couto, Jullianna;
Denis, Kevin;
Dünner, Rolando;
Eimer, Joseph;
Engelhoven, Trevor;
Fluxa, Pedro;
Halpern, Mark;
Harrington, Kathleen;
Helson, Kyle;
Hilton, Gene;
Hinshaw, Gary;
Hubmayr, Johannes;
Iuliano, Jeffrey;
Marriage, Tobias;
McMahon, Jeffrey;
Miller, Nathan;
Nuñez, Carolina;
Padilla, Ivan;
Palma, Gonzalo;
Parker, Lucas;
Petroff, Matthew;
Pradenas, Bastian;
Reeves, Rodrigo;
Reintsema, Carl;
Rostem, Karwan;
Sagliocca, Marco;
U-Yen, Kongpop;
Valle, Deniz;
Wang, Bingjie;
Wang, Qinan;
Watts, Duncan;
Weiland, Janet;
Wollack, Edward;
Xu, Zhilei;
Yan, Ziang;
Zen, Lingzhen
Submitted: 2018-07-10
The Cosmology Large Angular Scale Surveyor (CLASS) aims to detect and
characterize the primordial B-mode signal and make a sample-variance-limited
measurement of the optical depth to reionization. CLASS is a ground-based,
multi-frequency microwave polarimeter that surveys 70% of the microwave sky
every day from the Atacama Desert. The focal plane detector arrays of all CLASS
telescopes contain smooth-walled feedhorns that couple to transition-edge
sensor (TES) bolometers through symmetric planar orthomode transducer (OMT)
antennas. These low noise polarization-sensitive detector arrays are fabricated
on mono-crystalline silicon wafers to maintain TES uniformity and optimize
optical efficiency throughout the wafer. In this paper, we discuss the design
and characterization of the first CLASS 93 GHz detector array. We measure the
dark parameters, bandpass, and noise spectra of the detectors and report that
the detectors are photon-noise limited. With current array yield of 82%, we
estimate the total array noise-equivalent power (NEP) to be 2.1
aW$\sqrt[]{\mathrm{s}}$.
[6]
oai:arXiv.org:1711.01314 [pdf] - 1877825
Intensity-Coupled-Polarization in Instruments with a Continuously
Rotating Half-Wave Plate
Didier, Joy;
Miller, Amber D.;
Araujo, Derek;
Aubin, François;
Geach, Christopher;
Johnson, Bradley;
Korotkov, Andrei;
Raach, Kate;
Westbrook, Benjamin;
Young, Karl;
Aboobaker, Asad M.;
Ade, Peter;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Jones, Terry;
Klein, Jeff;
Lee, Adrian;
Limon, Michele;
MacDermid, Kevin;
Milligan, Michael;
Pascale, Enzo;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Zilic, Kyle
Submitted: 2017-11-03, last modified: 2018-02-28
We discuss a systematic effect associated with measuring polarization with a
continuously rotating half-wave plate. The effect was identified with the data
from the E and B Experiment (EBEX), which was a balloon-borne instrument
designed to measure the polarization of the CMB as well as that from Galactic
dust. The data show polarization fraction larger than 10\% while less than 3\%
were expected from instrumental polarization. We give evidence that the excess
polarization is due to detector non-linearity in the presence of a continuously
rotating HWP. The non-linearity couples intensity signals into polarization. We
develop a map-based method to remove the excess polarization. Applying this
method for the 150 (250) GHz bands data we find that 81\% (92\%) of the excess
polarization was removed. Characterization and mitigation of this effect is
important for future experiments aiming to measure the CMB B-modes with a
continuously rotating HWP.
[7]
oai:arXiv.org:1707.05879 [pdf] - 1586095
A Compact Cryogenic Thermal Source for Detector Array Characterization
Submitted: 2017-07-18
We describe the design, fabrication, and validation of a
cryogenically-compatible quasioptical thermal source designed to be used for
characterization of detector arrays. The source is constructed using a
graphite-loaded epoxy mixture that is molded into a tiled pyramidal structure.
The mold is fabricated using a hardened steel template produced via a wire EDM
process. The absorptive mixture is bonded to a copper backplate enabling
thermalization of the entire structure. The source reflectance is measured from
30-300 GHz and compared to models.
[8]
oai:arXiv.org:1703.03847 [pdf] - 1783689
The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
The EBEX Collaboration;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Savini, Giorgio;
Spencer, Locke;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2017-03-10, last modified: 2017-05-30
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic
microwave background polarimeter that flew over Antarctica in 2013. We describe
the experiment's optical system, receiver, and polarimetric approach, and
report on their in-flight performance. EBEX had three frequency bands centered
on 150, 250, and 410 GHz. To make efficient use of limited mass and space we
designed a 115 cm$^{2}$sr high throughput optical system that had two ambient
temperature mirrors and four anti-reflection coated polyethylene lenses per
focal plane. All frequency bands shared the same optical train. Polarimetry was
achieved with a continuously rotating achromatic half-wave plate (AHWP) that
was levitated with a superconducting magnetic bearing (SMB). Rotation stability
was 0.45 % over a period of 10 hours, and angular position accuracy was 0.01
degrees. This is the first use of a SMB in astrophysics. The measured
modulation efficiency was above 90 % for all bands. To our knowledge the 109 %
fractional bandwidth of the AHWP was the broadest implemented to date. The
receiver that contained one lens and the AHWP at a temperature of 4 K, the
polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K
performed according to specifications giving focal plane temperature stability
with fluctuation power spectrum that had $1/f$ knee at 2 mHz. EBEX was the
first balloon-borne instrument to implement technologies characteristic of
modern CMB polarimeters including high throughput optical systems, and large
arrays of transition edge sensor bolometric detectors with mutiplexed readouts.
[9]
oai:arXiv.org:1702.07020 [pdf] - 1783687
The EBEX Balloon-Borne Experiment - Gondola, Attitude Control, and
Control Software
The EBEX Collaboration;
Aboobaker, Asad;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Moncelsi, Lorenzo;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2017-02-22, last modified: 2017-04-11
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument
designed to measure the polarization of the cosmic microwave background (CMB)
radiation. EBEX was the first balloon-borne instrument to implement a
kilo-pixel array of transition edge sensor (TES) bolometric detectors and the
first CMB experiment to use the digital version of the frequency domain
multiplexing system for readout of the TES array. The scan strategy relied on
40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique
demands on the design and operation of the payload that resulted from these new
technologies and the scan strategy. We describe the solutions implemented
including the development of a power system designed to provide a total of at
least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors'
readout system, software to manage and handle the data of the kilo-pixel array,
and specialized attitude reconstruction software. We present flight performance
data showing faultless management of the TES array, adequate powering and
cooling of the readout electronics, and constraint of attitude reconstruction
errors such that the spurious B-modes they induced were less than 10% of CMB
B-mode power spectrum with $r=0.05$.
[10]
oai:arXiv.org:1602.03249 [pdf] - 1356056
A high-resolution pointing system for fast scanning platforms: The EBEX
example
Didier, Joy;
Chapman, Daniel;
Aboobaker, Asad;
Araujo, Derek;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Korotkov, Andrei;
Limon, Michele;
Miller, Amber;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Greg;
Vinokurov, Yuri
Submitted: 2016-02-09
The E and B experiment (EBEX) is a balloon-borne telescope designed to
measure the polarization of the cosmic microwave background with 8' resolution
employing a gondola scanning with speeds of order degree per second. In January
2013, EBEX completed 11 days of observations in a flight over Antarctica
covering $\sim$ 6000 square degrees of the sky. The payload is equipped with
two redundant star cameras and two sets of three orthogonal gyroscopes to
reconstruct the telescope attitude. The EBEX science goals require the pointing
to be reconstructed to approximately 10" in the map domain, and in-flight
attitude control requires the real time pointing to be accurate to $\sim$
0.5$^{\circ}$ . The high velocity scan strategy of EBEX coupled to its float
altitude only permits the star cameras to take images at scan turnarounds,
every $\sim$ 40 seconds, and thus requires the development of a pointing system
with low noise gyroscopes and carefully controlled systematic errors. Here we
report on the design of the pointing system and on a simulation pipeline
developed to understand and minimize the effects of systematic errors. The
performance of the system is evaluated using the 2012/2013 flight data, and we
show that we achieve a pointing error with RMS=25" on 40 seconds azimuth
throws, corresponding to an error of $\sim$ 4.6" in the map domain.
[11]
oai:arXiv.org:1601.07923 [pdf] - 1350058
Temperature calibration of the E and B experiment
Aubin, Francois;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen;
Geach, Christopher;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Macdermid, Kevin;
Marchenko, Valerie;
Miller, Amber D.;
Milligan, Michael;
Pascale, Enzo;
Puglisi, Giuseppe;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2016-01-28
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to
measure the polarization of the cosmic microwave background radiation and to
characterize the polarization of galactic dust. EBEX was launched December 29,
2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky
during 11 days at three frequency bands centered around 150, 250 and 410 GHz.
EBEX was the first experiment to operate a kilo-pixel array of transition-edge
sensor bolometers and a continuously rotating achromatic half-wave plate aboard
a balloon platform. It also pioneered the use of detector readout based on
digital frequency domain multiplexing.
We describe the temperature calibration of the experiment. The gain response
of the experiment is calibrated using a two-step iterative process. We use
signals measured on passes across the Galactic plane to convert from
readout-system counts to power. The effective smoothing scale of the EBEX
optics and the star camera-to-detector offset angles are determined through
\c{hi}2 minimization using the compact HII region RCW 38. This two-step process
is initially performed with parameters measured before the EBEX 2013 flight and
then repeated until the calibration factor and parameters converge.
[12]
oai:arXiv.org:1407.6894 [pdf] - 1215912
The performance of the bolometer array and readout system during the
2012/2013 flight of the E and B experiment (EBEX)
MacDermid, Kevin;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Francois;
Baccigalupi, Carlo;
Bandura, Kevin;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Hannes;
Irwin, Kent;
Johnson, Bradley;
Jaffe, Andrew;
Jones, Terry;
Kisner, Ted;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Greg;
Westbrook, Ben;
Zilic, Kyle
Submitted: 2014-07-22
EBEX is a balloon-borne telescope designed to measure the polarization of the
cosmic microwave background radiation. During its eleven day science flight in
the Austral Summer of 2012, it operated 955 spider-web transition edge sensor
(TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the
first time that an array of TES bolometers has been used on a balloon platform
to conduct science observations. Polarization sensitivity was provided by a
wire grid and continuously rotating half-wave plate. The balloon implementation
of the bolometer array and readout electronics presented unique development
requirements. Here we present an outline of the readout system, the remote
tuning of the bolometers and Superconducting QUantum Interference Device
(SQUID) amplifiers, and preliminary current noise of the bolometer array and
readout system.
[13]
oai:arXiv.org:1106.2507 [pdf] - 372118
Thermal architecture for the SPIDER flight cryostat
Gudmundsson, J. E.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
O'Dea, D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Helson, K. R.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.
Submitted: 2011-06-13
We describe the cryogenic system for SPIDER, a balloon-borne microwave
polarimeter that will map 8% of the sky with degree-scale angular resolution.
The system consists of a 1284 L liquid helium cryostat and a 16 L
capillary-filled superfluid helium tank, which provide base operating
temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption
refrigerators supply sub-Kelvin cooling power to multiple focal planes, which
are housed in monochromatic telescope inserts. The main helium tank is
suspended inside the vacuum vessel with thermally insulating fiberglass
flexures, and shielded from thermal radiation by a combination of two vapor
cooled shields and multi-layer insulation. This system allows for an extremely
low instrumental background and a hold time in excess of 25 days. The total
mass of the cryogenic system, including cryogens, is approximately 1000 kg.
This enables conventional long duration balloon flights. We will discuss the
design, thermal analysis, and qualification of the cryogenic system.
[14]
oai:arXiv.org:1006.3874 [pdf] - 934286
Modeling and characterization of the SPIDER half-wave plate
Bryan, Sean A.;
Ade, Peter A. R.;
Amiri, Mandana;
Benton, Steve;
Bihary, Richard;
Bock, James J.;
Bond, J. Richard;
Bonetti, Joseph A.;
Chiang, H. Cynthia;
Contaldi, Carlo R.;
Crill, Brendan P.;
O'Dea, Daniel;
Dore, Olivier;
Farhang, Marzieh;
Filippini, Jeffrey P.;
Fissel, Laura;
Gandilo, Natalie;
Golwala, Sunil;
Gudmundsson, Jon E.;
Hasselfield, Matthew;
Halpern, Mark;
Helson, Kyle R.;
Hilton, Gene;
Holmes, Warren;
Hristov, Viktor V.;
Irwin, Kent D.;
Jones, William C.;
Kuo, Chao Lin;
MacTavish, Carrie J.;
Mason, Peter;
Morford, Tracy;
Montroy, Thomas E.;
Netterfield, C. Barth;
Rahlin, Alexandra S.;
Reintsema, Carl D.;
Riley, Daniel;
Ruhl, John E.;
Runyan, Marcus C.;
Schenker, Matthew A.;
Shariff, Jamil;
Soler, Juan Diego;
Trangsrud, Amy;
Tucker, Rebecca;
Tucker, Carole;
Turner, Anthony
Submitted: 2010-06-19
Spider is a balloon-borne array of six telescopes that will observe the
Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the
instrument will make a polarization map of the CMB with approximately one-half
degree resolution at 145 GHz. Polarization modulation is achieved via a
cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have
measured millimeter-wave transmission spectra of the sapphire at room and
cryogenic temperatures. The spectra are consistent with our physical optics
model, and the data gives excellent measurements of the indices of A-cut
sapphire. We have also taken preliminary spectra of the integrated HWP, optical
system, and detectors in the prototype Spider receiver. We calculate the
variation in response of the HWP between observing the CMB and foreground
spectra, and estimate that it should not limit the Spider constraints on
inflation.