oai:arXiv.org:1511.07718 [pdf] - 1317175
The scintillation of liquid argon
Submitted: 2015-11-24
A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm
to 1000 nm is presented. Excitation was performed using continuous and pulsed
12 keV electron beams. The emission is dominated by the analogue of the so
called 2nd excimer continuum. Various additional emission features were found.
The time structure of the light emission has been measured for a set of well
defined wavelength positions. The results help to interpret literature data in
the context of liquid rare gas detectors in which the wavelength information is
lost due to the use of wavelength shifters.
[2]
oai:arXiv.org:1511.07720 [pdf] - 1317176
Table-top setup for investigating the scintillation properties of liquid
argon
Submitted: 2015-11-24
The spectral and temporal light emission properties of liquid argon have been
studied in the context of its use in large liquid rare-gas detectors for
detecting Dark Matter particles in astronomy. A table-top setup has been
developed. Continuous and pulsed low energy electron beam excitation is used to
stimulate light emission. A spectral range from 110 to 1000 nm in wavelength is
covered by the detection system with a time resolution on the order of 1 ns.
[3]
oai:arXiv.org:1511.07721 [pdf] - 1317177
Ion-beam excitation of liquid argon
Hofmann, M.;
Dandl, T.;
Heindl, T.;
Neumeier, A.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
The scintillation light of liquid argon has been recorded wavelength and time
resolved with very good statistics in a wavelength interval ranging from 118 nm
through 970 nm. Three different ion beams, protons, sulfur ions and gold ions,
were used to excite liquid argon. Only minor differences were observed in the
wavelength-spectra obtained with the different incident particles. Light
emission in the wavelength range of the third excimer continuum was found to be
strongly suppressed in the liquid phase. In time-resolved measurements, the
time structure of the scintillation light can be directly attributed to
wavelength in our studies, as no wavelength shifter has been used. These
measurements confirm that the singlet-to-triplet intensity ratio in the second
excimer continuum range is a useful parameter for particle discrimination,
which can also be employed in wavelength-integrated measurements as long as the
sensitivity of the detector system does not rise steeply for wavelengths longer
than 190 nm. Using our values for the singlet-to-triplet ratio down to low
energies deposited a discrimination threshold between incident protons and
sulfur ions as low as $\sim$2.5 keV seems possible, which represents the
principle limit for the discrimination of these two species in liquid argon.
[4]
oai:arXiv.org:1511.07722 [pdf] - 1317178
Intense Infrared Scintillation of Liquid Ar-Xe Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Hagn, H.;
Hofmann, M.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Intense infrared (IR) light emission from liquid Ar-Xe mixtures has been
observed using 12 keV electron-beam excitation. The emission peaks at a
wavelength of 1.18 $\mu$m and the half-width of the emission band is 0.1
$\mu$m. Maximum intensity has been found for a 10 ppm xenon admixture in liquid
argon. The conversion efficiency of electron beam-power to IR-light is about 1%
(10000 photons per MeV electron energy deposited). A possible application of
this intense IR emission for a new particle discrimination concept in liquid
noble gas detectors is discussed. No light emission was found for perfectly
purified liquid argon in the wavelength range from 0.5 to 3.5 $\mu$m on the
current level of sensitivity.
[5]
oai:arXiv.org:1511.07723 [pdf] - 1317179
Intense Vacuum-Ultraviolet and Infrared Scintillation of Liquid Ar-Xe
Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Vacuum ultraviolet light emission from xenon-doped liquid argon is described
in the context of liquid noble gas particle detectors. Xenon concentrations in
liquid argon from 0.1 ppm to 1000 ppm were studied. The energy transfer from
the second excimer continuum of argon ($\sim$127 nm) to the second excimer
continuum of xenon ($\sim$174 nm) is observed by recording optical emission
spectra. The transfer almost saturates at a xenon concentration of $\sim$10 ppm
for which, in addition, an intense emission in the infrared at a peak
wavelength of 1.17 $\mu$m with (13000$\pm$4000) photons per MeV deposited by
electrons had been found. The corresponding value for the VUV emission at a
peak wavelength of 174 nm (second excimer continuum of xenon) is determined to
be (20000$\pm$6000) photons per MeV electron energy deposited. Under these
excitation conditions pure liquid argon emits (22000$\pm$3000) photons per MeV
electron energy deposited at a peak wavelength of 127nm. An electron-beam
induced emission spectrum for the 10 ppm Ar-Xe liquid mixture ranging from 115
nm to 3.5 $\mu$m is presented. VUV emission spectra from xenon-doped liquid
argon with exponentially varied xenon concentrations from 0.1 ppm to 1000 ppm
are also shown. Time structure measurements of the light emissions at
well-defined wavelength positions in the vacuum ultraviolet as well as in the
near-infrared are presented.
[6]
oai:arXiv.org:1511.07724 [pdf] - 1317180
Attenuation of vacuum ultraviolet light in liquid argon
Submitted: 2015-11-24
The transmission of liquid argon has been measured, wavelength resolved, for
a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation
length is presented for pure argon. It is shown that no universal wavelength
independent attenuation length can be assigned to liquid argon for its own
fluorescence light due to the interplay between the wavelength dependent
emission and absorption. A decreasing transmission is observed below 130 nm in
both chemically cleaned and distilled liquid argon and assigned to absorption
by the analogue of the first argon excimer continuum. For not perfectly cleaned
argon a strong influence of impurities on the transmission is observed. Two
strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm
width, respectively, are assigned to traces of xenon in argon. A broad
absorption region below 180 nm is found for unpurified argon and tentatively
attributed to the presence of water in the argon sample.