sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Heilmann, Ralf

Normalized to: Heilmann, R.

6 article(s) in total. 42 co-authors, from 1 to 5 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:2004.13001  [pdf] - 2119963
Optical design of diffraction-limited X-ray telescopes
Comments: 20 pages, 11 figures, accepted for publication in Applied Optics
Submitted: 2020-04-24
Astronomical imaging with micro-arcsecond ($\mu$as) angular resolution could enable breakthrough scientific discoveries. Previously-proposed $\mu$as X-ray imager designs have been interferometers with limited effective collecting area. Here we describe X-ray telescopes achieving diffraction-limited performance over a wide energy band with large effective area, employing a nested-shell architecture with grazing-incidence mirrors, while matching the optical path lengths between all shells. We present two compact nested-shell Wolter Type 2 grazing-incidence telescope designs for diffraction-limited X-ray imaging: a micro-arcsecond telescope design with 14 $\mu$as angular resolution and 2.9 m$^2$ of effective area at 5 keV photon energy ($\lambda$=0.25 nm), and a smaller milli-arcsecond telescope design with 525 $\mu$as resolution and 645 cm$^2$ effective area at 1 keV ($\lambda$=1.24 nm). We describe how to match the optical path lengths between all shells in a compact mirror assembly, and investigate chromatic and off-axis aberrations. Chromatic aberration results from total external reflection off of mirror surfaces, and we greatly mitigate its effects by slightly adjusting the path lengths in each mirror shell. The mirror surface height error and alignment requirements for diffraction-limited performance are challenging but arguably achieveable in the coming decades. Since the focal ratio for a diffraction-limited X-ray telescope is extremely large ($f/D$~10$^5$), the only important off-axis aberration is curvature of field, so a 1 arcsecond field of view is feasible with a flat detector. The detector must fly in formation with the mirror assembly, but relative positioning tolerances are on the order of 1 m over a distance of some tens to hundreds of kilometers. While there are many challenges to achieving diffraction-limited X-ray imaging, we did not find any fundamental barriers.
[2]  oai:arXiv.org:1812.08229  [pdf] - 1834189
Demonstration of resolving power $\lambda/\Delta\lambda > 10,000$ for a space-based x-ray transmission grating spectrometer
Comments:
Submitted: 2018-12-19
We present measurements of the resolving power of a soft x-ray spectrometer consisting of 200 nm-period lightweight, alignment-insensitive critical-angle transmission (CAT) gratings and a lightweight slumped-glass Wolter-I focusing mirror pair. We measure and model contributions from source, mirrors, detector pixel size, and grating period variation to the natural line width spectrum of the Al and Mg K$_{\alpha_1 \alpha_2}$ doublets. Measuring up to 18$^{\rm th}$ diffraction order at characteristic Al-K wavelengths we consistently obtain small broadening due to gratings corresponding to a minimum effective grating resolving power $R_g > 10,000$ with 90\% confidence. Upper limits are often compatible with $R_g = \infty$. Independent fitting of different diffraction orders, as well as ensemble fitting of multiple orders at multiple wavelengths, gives compatible results. Our data leads to uncertainties for the Al-K$_{\alpha}$ doublet line width and line separation parameters 2-3 times smaller than values found in the literature. Data from three different gratings are mutually compatible. This demonstrates that CAT gratings perform in excess of the requirements for the Arcus Explorer mission and are suitable for next-generation space-based x-ray spectrometer designs with resolving power 5-10 times higher than the transmission grating spectrometer on the Chandra X-ray Observatory.
[3]  oai:arXiv.org:1607.04517  [pdf] - 1521256
Critical-angle x-ray transmission grating spectrometer with extended bandpass and resolving power > 10,000
Comments: submitted to Proc. SPIE 9905
Submitted: 2016-07-15
Several high priority subjects in astrophysics can be addressed by a state-of-the-art soft x-ray grating spectrometer (XGS). An Explorer-scale, large-area (> 1,000 cm2), high resolving power (R > 3,000) XGS is highly feasible based on Critical-Angle Transmission (CAT) gratings, even for telescopes with angular resolution of 5-10 arcsec. Significantly higher performance can be provided by a CAT XGS on an X-ray-Surveyor-type mission. CAT gratings combine the advantages of blazed reflection gratings (high efficiency, use of higher diffraction orders) with those of transmission gratings (low mass, relaxed alignment and temperature requirements, transparent at high energies) with minimal mission resource demands. They are high-efficiency blazed transmission gratings that consist of freestanding, ultra-high aspect-ratio grating bars made from SOI wafers using anisotropic dry and wet etch techniques. Blazing is achieved through reflection off grating bar sidewalls. Silicon is well matched to the soft x-ray band, and existing silicon CAT gratings exceed 30% absolute diffraction efficiency, with clear paths for improvement. CAT gratings coated with heavier elements allow extension of the CAT grating principle to higher energies and larger angles, enabling higher resolving power at shorter wavelengths. We show x-ray data from CAT gratings coated with platinum using atomic layer deposition, and demonstrate blazing to higher energies and much larger blaze angles than possible with silicon. We measure resolving power of a CAT XGS consisting of a Wolter-I focusing mirror pair from GSFC and CAT gratings, performed at the MSFC SLF. Measurement of the Al Ka doublet in 18th order shows resolving power > 10,000, based on preliminary analysis. This demonstrates that currently fabricated CAT gratings are compatible with the most advanced XGS designs for future soft x-ray spectroscopy missions.
[4]  oai:arXiv.org:0908.0677  [pdf] - 1003290
Broad-Band Soft X-ray Polarimetry
Comments: 6 pages, 3 figures (2 color); to appear in proceedings of "The Coming of Age of X-ray Polarimetry"
Submitted: 2009-08-05
We developed an instrument design capable of measuring linear X-ray polarization over a broad-band using conventional spectroscopic optics. A set of multilayer-coated flats reflects the dispersed X-rays to the instrument detectors. The intensity variation with position angle is measured to determine three Stokes parameters: I, Q, and U -- all as a function of energy. By laterally grading the multilayer optics and matching the dispersion of the gratings, one may take advantage of high multilayer reflectivities and achieve modulation factors > 50% over the entire 0.2 to 0.8 keV band. This instrument could be used in a small orbiting mission or scaled up for the International X-ray Observatory. Laboratory work has begun that would demonstrate the capabilities of key components.
[5]  oai:arXiv.org:0904.3382  [pdf] - 23561
Distribution and Structure of Matter in and around Galaxies
Comments: A White Paper Submitted to the Astro2010 Decadal Survey
Submitted: 2009-04-22
Understanding the origins and distribution of matter in the Universe is one of the most important quests in physics and astronomy. Themes range from astro-particle physics to chemical evolution in the Galaxy to cosmic nucleosynthesis and chemistry in an anticipation of a full account of matter in the Universe. Studies of chemical evolution in the early Universe will answer questions about when and where the majority of metals were formed, how they spread and why they appar today as they are. The evolution of matter in our Universe cannot be characterized as a simple path of development. In fact the state of matter today tells us that mass and matter is under constant reformation through on-going star formation, nucleosynthesis and mass loss on stellar and galactic scales. X-ray absorption studies have evolved in recent years into powerful means to probe the various phases of interstellar and intergalactic media. Future observatories such as IXO and Gen-X will provide vast new opportunities to study structure and distribution of matter with high resolution X-ray spectra. Specifically the capabilities of the soft energy gratings with a resolution of R=3000 onboard IXO will provide ground breaking determinations of element abundance, ionization structure, and dispersion velocities of the interstellar and intergalactic media of our Galaxy and the Local Group
[6]  oai:arXiv.org:0904.3385  [pdf] - 23562
Structure and Evolution of Pre-Main Sequence Stars
Comments: A White Paper Submitted to the Astro2010 Decadal Survey
Submitted: 2009-04-22
Low-mass pre-main sequence (PMS) stars are strong and variable X-ray emitters, as has been well established by EINSTEIN and ROSAT observatories. It was originally believed that this emission was of thermal nature and primarily originated from coronal activity (magnetically confined loops, in analogy with Solar activity) on contracting young stars. Broadband spectral analysis showed that the emission was not isothermal and that elemental abundances were non-Solar. The resolving power of the Chandra and XMM X-ray gratings spectrometers have provided the first, tantalizing details concerning the physical conditions such as temperatures, densities, and abundances that characterize the X-ray emitting regions of young star. These existing high resolution spectrometers, however, simply do not have the effective area to measure diagnostic lines for a large number of PMS stars over required to answer global questions such as: how does magnetic activity in PMS stars differ from that of main sequence stars, how do they evolve, what determines the population structure and activity in stellar clusters, and how does the activity influence the evolution of protostellar disks. Highly resolved (R>3000) X-ray spectroscopy at orders of magnitude greater efficiency than currently available will provide major advances in answering these questions. This requires the ability to resolve the key diagnostic emission lines with a precision of better than 100 km/s.