Normalized to: Hechenblaikner, G.
[1]
oai:arXiv.org:1508.01032 [pdf] - 1445715
Performance of a radiatively cooled system for quantum optomechanical
experiments in space
Submitted: 2015-08-05
The performance of a radiatively cooled instrument is investigated in the
context of optomechanical quantum experiments, where the environment of a
macroscopic particle in a quantum-superposition has to be cooled to less than
20\,K in deep space. A heat-transfer analysis between the components of the
instrument as well as a transfer-function analysis on thermal oscillations
induced by the spacecraft interior and by dissipative sources is performed. The
thermal behaviour of the instrument in an orbit around a Lagrangian point and
in a highly elliptical Earth orbit is discussed. Finally, we investigate
further possible design improvements aiming at lower temperatures of the
environment of the macroscopic particle. These include a mirror-based design of
the imaging system on the optical bench and the extension of the heat shields.
[2]
oai:arXiv.org:1310.0084 [pdf] - 915442
STE-QUEST Mission and System Design - Overview after completion of
Phase-A
Submitted: 2013-09-30, last modified: 2014-01-25
STE-QUEST is a fundamental science mission which is considered for launch
within the Cosmic Vision programme of the European Space Agency (ESA). Its main
scientific objectives relate to probing various aspects of Einstein's theory of
general relativity by measuring the gravitational red-shift of the earth, the
moon and the sun as well as testing the weak equivalence principle to
unprecedented accuracy. In order to perform the measurements, the system
features a spacecraft equipped with two complex instruments, an atomic clock
and an atom interferometer, a ground-segment encompassing several
ground-terminals collocated with the best available ground atomic clocks, and
clock comparison between space and ground via microwave and optical links. The
baseline orbit is highly eccentric and exhibits strong variations of incident
solar flux, which poses challenges for thermal and power subsystems in addition
to the difficulties encountered by precise-orbit-determination at high
altitudes. The mission assessment and definition phase (Phase-A) has recently
been completed and this paper gives a concise overview over some system level
results.
[3]
oai:arXiv.org:1309.3234 [pdf] - 815790
How cold can you get in space? Quantum Physics at cryogenic temperatures
in space
Submitted: 2013-09-12, last modified: 2013-09-13
Although it is often believed that the coldness of space is ideally suited
for performing measurements at cryogenic temperatures, this must be regarded
with caution for two reasons: Firstly, the sensitive instrument must be
completely shielded from the strong solar radiation and therefore, e.g. either
be placed inside a satellite or externally on the satellite's shaded side.
Secondly, any platform hosting such an experiment in space generally provides
an environment close to room temperature for the accommodated equipment. To
obtain cryogenic temperatures without active cooling, one must isolate the
instrument from radiative and conductive heat exchange with the platform as
well as possible. We investigate the limits of this passive cooling method in
the context of a recently proposed experiment to observe the decoherence of
quantum superpositions of massive objects. The analyses and conclusions are
applicable to a host of similar experimental designs requiring a cryogenic
environment in space.
[4]
oai:arXiv.org:1307.8154 [pdf] - 700992
Fundamental Performance Determining Factors of the Ultrahigh-Precision
Space-Borne Optical Metrology System for the LISA Pathfinder mission
Submitted: 2013-07-30
The LISA Pathfinder mission to space employs an optical metrology system
(OMS) at its core to measure the distance and attitude between two freely
floating test-masses to picometer and nanorad accuracy, respectively, within
the measurement band of [1 mHz, 30 mHz]. The OMS is based upon an ultra-stable
optical bench with 4 heterodyne interferometers from which interference signals
are read-out and processed by a digital phase-meter. Laser frequency noise,
power fluctuations and optical path-length variations are suppressed to
uncritical levels by dedicated control loops so that the measurement
performance approaches the sensor limit imposed by the phase-meter. The system
design is such that low frequency common mode noise which affects the read-out
phase of all four interferometers is generally well suppressed by subtraction
of a reference phase from the other interferometer signals. However, high
frequency noise directly affects measurement performance and its common mode
rejection depends strongly on the relative signal phases. We discuss how the
data from recent test campaigns point towards high frequency phase noise as a
likely performance limiting factor which explains some important performance
features.