Normalized to: Hays-Wehle, J.
[1]
oai:arXiv.org:1811.11313 [pdf] - 1791684
SOFIA - HIRMES: Looking forward to the HIgh-Resolution Mid-infrarEd
Spectrometer
Richards, Samuel N.;
Moseley, Samuel H.;
Stacey, Gordon;
Greenhouse, Matthew;
Kutyrev, Alexander;
Arendt, Richard;
Atanasoff, Hristo;
Banks, Stuart;
Brekosky, Regis P.;
Brown, Ari-David;
Bulcha, Berhanu;
Cazeau, Tony;
Choi, Michael;
Colazo, Felipe;
Engler, Chuck;
Hadjimichael, Theodore;
Hays-Wehle, James;
Henderson, Chuck;
Hsieh, Wen-Ting;
Huang, Jeffrey;
Jenstrom, Iver;
Kellogg, Jim;
Kimball, Mark;
Kovacs, Attila;
Leiter, Steve;
Maher, Steve;
McMurray, Robert;
Melnick, Gary J.;
Mentzell, Eric;
Mikula, Vilem;
Miller, Timothy M.;
Nagler, Peter;
Nikola, Thomas;
Oxborrow, Joseph;
Pontoppidan, Klaus M.;
Rangwala, Naseem;
Rhodes, Alan;
Roberge, Aki;
Rosner, Stefan;
Rostem, Karwan;
Rustemeyer, Nancy;
Sharp, Elmer;
Sparr, Leroy;
Stevanovic, Dejan;
Taraschi, Peter;
Temi, Pasquale;
Vacca, William D.;
de Lorenzo, Jordi Vila Hernandez;
Wohler, Bill;
Wollack, Edward J.;
Wilks, Shannon
Submitted: 2018-11-27
The HIgh-Resolution Mid-infrarEd Spectrometer (HIRMES) is the 3rd Generation
Instrument for the Stratospheric Observatory For Infrared Astronomy (SOFIA),
currently in development at the NASA Goddard Space Flight Center (GSFC), and
due for commissioning in 2019. By combining direct-detection Transition Edge
Sensor (TES) bolometer arrays, grating-dispersive spectroscopy, and a host of
Fabry-Perot tunable filters, HIRMES will provide the ability for High
Resolution (R~100,000), Mid-Resolution (R~10,000), and Low-Resolution (R~600)
slit-spectroscopy, and 2D Spectral Imaging (R~2000 at selected wavelengths)
over the 25 - 122 {\mu}m mid-far infrared waveband. The driving science
application is the evolution of proto-planetary systems via measurements of
water-vapor, water-ice, deuterated hydrogen (HD), and neutral oxygen lines.
However, HIRMES has been designed to be as flexible as possible to cover a wide
range of science cases that fall within its phase-space, all whilst reaching
sensitivities and observing powers not yet seen thus far on SOFIA, providing
unique observing capabilities which will remain unmatched for decades.
[2]
oai:arXiv.org:1710.04326 [pdf] - 1604980
Microwave SQUID Multiplexer demonstration for Cosmic Microwave
Background Imagers
Dober, B.;
Becker, D. T.;
Bennett, D. A.;
Bryan, S. A.;
Duff, S. M.;
Gard, J. D.;
Hays-Wehle, J. P.;
Hilton, G. C.;
Hubmayr, J.;
Mates, J. A. B.;
Reintsema, C. D.;
Vale, L. R.;
Ullom, J. N.
Submitted: 2017-10-11, last modified: 2017-12-15
Key performance characteristics are demonstrated for the microwave SQUID
multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that
have been optimized for cosmic microwave background (CMB) observations. In a
64-channel demonstration, we show that the $\mu$MUX produces a white, input
referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave
probe tone power, which is well below expected fundamental detector and photon
noise sources for a ground-based CMB-optimized bolometer. Operated with
negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the
TES-coupled channels biased at 65% of the sensor normal resistance. This noise
level is consistent with that predicted from bolometer thermal fluctuation
(i.e., phonon) noise. Furthermore, the power spectral density exhibits a white
spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on
large angular scales that constrain the physics of inflation. Additionally, we
report cross-talk measurements that indicate a level below 0.3%, which is less
than the level of cross-talk from multiplexed readout systems in deployed CMB
imagers. These measurements demonstrate the $\mu$MUX as a viable readout
technique for future CMB imaging instruments.
[3]
oai:arXiv.org:1611.07856 [pdf] - 1532790
When "Optimal Filtering" Isn't
Fowler, J. W.;
Alpert, B. K.;
Doriese, W. B.;
Hays-Wehle, J.;
Joe, Y. -I.;
Morgan, K. M.;
O'Neil, G. C.;
Reintsema, C. D.;
Schmidt, D. R.;
Ullom, J. N.;
Swetz, D. S.
Submitted: 2016-11-23
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses
is statistically optimal only if all pulses have the same shape, regardless of
energy. The shapes of pulses from a nonlinear detector can and do depend on the
pulse energy, however. A pulse-fitting procedure that we call "tangent
filtering" accounts for the energy dependence of the shape and should therefore
achieve superior energy resolution. We take a geometric view of the
pulse-fitting problem and give expressions to predict how much the energy
resolution stands to benefit from such a procedure. We also demonstrate the
method with a case study of K-line fluorescence from several 3d transition
metals. The method improves the resolution from 4.9 eV to 4.2 eV at the Cu
K$\alpha$ line (8.0keV).