sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Hays-Wehle, J.

Normalized to: Hays-Wehle, J.

3 article(s) in total. 70 co-authors, from 1 to 2 common article(s). Median position in authors list is 7,0.

[1]  oai:arXiv.org:1811.11313  [pdf] - 1791684
SOFIA - HIRMES: Looking forward to the HIgh-Resolution Mid-infrarEd Spectrometer
Comments: Accepted to the Journal of Astronomical Instrumentation (SOFIA Special Edition) on 11th November 2018
Submitted: 2018-11-27
The HIgh-Resolution Mid-infrarEd Spectrometer (HIRMES) is the 3rd Generation Instrument for the Stratospheric Observatory For Infrared Astronomy (SOFIA), currently in development at the NASA Goddard Space Flight Center (GSFC), and due for commissioning in 2019. By combining direct-detection Transition Edge Sensor (TES) bolometer arrays, grating-dispersive spectroscopy, and a host of Fabry-Perot tunable filters, HIRMES will provide the ability for High Resolution (R~100,000), Mid-Resolution (R~10,000), and Low-Resolution (R~600) slit-spectroscopy, and 2D Spectral Imaging (R~2000 at selected wavelengths) over the 25 - 122 {\mu}m mid-far infrared waveband. The driving science application is the evolution of proto-planetary systems via measurements of water-vapor, water-ice, deuterated hydrogen (HD), and neutral oxygen lines. However, HIRMES has been designed to be as flexible as possible to cover a wide range of science cases that fall within its phase-space, all whilst reaching sensitivities and observing powers not yet seen thus far on SOFIA, providing unique observing capabilities which will remain unmatched for decades.
[2]  oai:arXiv.org:1710.04326  [pdf] - 1604980
Microwave SQUID Multiplexer demonstration for Cosmic Microwave Background Imagers
Comments: 6 pages, 4 figures
Submitted: 2017-10-11, last modified: 2017-12-15
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $\mu$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $\mu$MUX as a viable readout technique for future CMB imaging instruments.
[3]  oai:arXiv.org:1611.07856  [pdf] - 1532790
When "Optimal Filtering" Isn't
Comments: Submitted to the Proceedings of the 2016 Applied Superconductivity Conference
Submitted: 2016-11-23
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy, however. A pulse-fitting procedure that we call "tangent filtering" accounts for the energy dependence of the shape and should therefore achieve superior energy resolution. We take a geometric view of the pulse-fitting problem and give expressions to predict how much the energy resolution stands to benefit from such a procedure. We also demonstrate the method with a case study of K-line fluorescence from several 3d transition metals. The method improves the resolution from 4.9 eV to 4.2 eV at the Cu K$\alpha$ line (8.0keV).