sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Haussmann, F.

Normalized to: Haussmann, F.

14 article(s) in total. 184 co-authors, from 1 to 14 common article(s). Median position in authors list is 18,5.

[1]  oai:arXiv.org:1911.00611  [pdf] - 1990433
The GRAVITY Young Stellar Object survey -- I. Probing the disks of Herbig Ae/Be stars in terrestrial orbits
Comments: Accepted for publication in A&A; 23 pages, 16 figures, 7 tables
Submitted: 2019-11-01
The formation and the evolution of protoplanetary disks are important stages in the lifetime of stars. The processes of disk evolution and planet formation are intrinsically linked. We spatially resolve with GRAVITY/VLTI in the K-band the sub au-scale region of 27 stars to gain statistical understanding of their properties. We look for correlations with stellar parameters, such as luminosity, mass, temperature and age. Our sample also cover a range of various properties in terms of reprocessed flux, flared or flat morphology, and gaps. We developed semi-physical geometrical models to fit our interferometric data. Our best models correspond to smooth and wide rings, implying that wedge-shaped rims at the dust sublimation edge are favored, as found in the H-band. The closure phases are generally non-null with a median value of ~10 deg, indicating spatial asymmetries of the intensity distributions. Multi-size grain populations could explain the closure phase ranges below 20-25 deg but other scenarios should be invoked to explain the largest ones. Our measurements extend the Radius-Luminosity relation to ~1e4 Lsun and confirm the significant spread around the mean relation observed in the H-band. Gapped sources exhibit a large N-to-K band size ratio and large values of this ratio are only observed for the members of our sample that would be older than 1 Ma, less massive, and with lower luminosity. In the 2 Ms mass range, we observe a correlation in the increase of the relative age with the transition from group II to group I, and an increase of the N-to-K size ratio. However, the size of the current sample does not yet permit us to invoke a clear universal evolution mechanism across the HAeBe mass range. The measured locations of the K-band emission suggest that these disks might be structured by forming young planets, rather than by depletion due to EUV, FUV, and X-ray photo-evaporation.
[2]  oai:arXiv.org:1808.02141  [pdf] - 1729246
GRAVITY chromatic imaging of Eta Car's core
GRAVITY Collaboration; Sanchez-Bermudez, J.; Weigelt, G.; Bestenlehner, J. M.; Kervella, P.; Brandner, W.; Henning, Th.; Müller, A.; Perrin, G.; Pott, J. -U.; Schöller, M.; van Boekel, R.; Abuter, R.; Accardo, M.; Amorim, A.; Anugu, N.; Ávila, G.; Benisty, M.; Berger, J. P.; Blind, N.; Bonnet, H.; Bourget, P.; Brast, R.; Buron, A.; Cantalloube, F.; Garatti, A. Caratti o; Cassaing, F.; Chapron, F.; Choquet, E.; Clénet, Y.; Collin, C.; Foresto, V. Coudé du; de Wit, W.; de Zeeuw, T.; Deen, C.; Delplancke-Ströbele, F.; Dembet, R.; Derie, F.; Dexter, J.; Duvert, G.; Ebert, M.; Eckart, A.; Eisenhauer, F.; Esselborn, M.; Fédou, P.; Garcia, P. J. V.; Dabo, C. E. Garcia; Lopez, R. Garcia; Gao, F.; Gendron, E.; Genzel, R.; Gillessen, S.; Haubois, X.; Haug, M.; Haussmann, F.; Hippler, S.; Horrobin, M.; Huber, A.; Hubert, Z.; Hubin, N.; Hummel, C. A.; Jakob, G.; Jochum, L.; Jocou, L.; Karl, M.; Kaufer, A.; Kellner, S.; Kendrew, S.; Kern, L.; Kiekebusch, M.; Klein, R.; Kolb, J.; Kulas, M.; Lacour, S.; Lapeyrère, V.; Lazareff, B.; Bouquin, J. -B. Le; Léna, P.; Lenzen, R.; Levêque, S.; Lippa, M.; Magnard, Y.; Mehrgan, L.; Mellein, M.; Mérand, A.; Moreno-Ventas, J.; Moulin, T.; Müller, E.; Müller, F.; Neumann, U.; Oberti, S.; Ott, T.; Pallanca, L.; Panduro, J.; Pasquini, L.; Paumard, T.; Percheron, I.; Perraut, K.; Petrucci, P. -O.; Pflüger, A.; Pfuhl, O.; Duc, T. P.; Plewa, P. M.; Popovic, D.; Rabien, S.; Ramirez, A.; Ramos, J.; Rau, C.; Riquelme, M.; Rodríguez-Coira, G.; Rohloff, R. -R.; Rosales, A.; Rousset, G.; Scheithauer, S.; Schuhler, N.; Spyromilio, J.; Straub, O.; Straubmeier, C.; Sturm, E.; Suarez, M.; Tristram, K. R. W.; Ventura, N.; Vincent, F.; Waisberg, I.; Wank, I.; Widmann, F.; Wieprecht, E.; Wiest, M.; Wiezorrek, E.; Wittkowski, M.; Woillez, J.; Wolff, B.; Yazici, S.; Ziegler, D.; Zins, G.
Comments: 32 pages, 27 figures (14 in the main body, 13 in the appendices), accepted for publication in AA
Submitted: 2018-08-06
Eta Car is one of the most intriguing luminous blue variables in the Galaxy. Observations and models at different wavelengths suggest a central binary with a 5.54 yr period residing in its core. 2D and 3D radiative transfer and hydrodynamic simulations predict a primary with a dense and slow stellar wind that interacts with the faster and lower density wind of the secondary. The wind-wind collision scenario suggests that the secondary's wind penetrates the primary's wind creating a low-density cavity in it, with dense walls where the two winds interact. We aim to trace the inner ~5-50 au structure of Eta Car's wind-wind interaction, as seen through BrG and, for the first time, through the He I 2s-2p line. We have used spectro-interferometric observations with GRAVITY at the VLTI. Our modeling of the continuum allows us to estimate its FWHM angular size close to 2 mas and an elongation ratio of 1.06 +/- 0.05 over a PA = 130 +/- 20 deg. Our CMFGEN modeling helped us to confirm that the role of the secondary should be taken into account to properly reproduce the observed BrG and He I lines. Chromatic images across BrG reveal a southeast arc-like feature, possibly associated to the hot post-shocked winds flowing along the cavity wall. The images of He I 2s-2p served to constrain the 20 mas structure of the line-emitting region. The observed morphology of He I suggests that the secondary is responsible for the ionized material that produces the line profile. Both the BrG and the He I 2s-2p maps are consistent with previous hydrodynamical models of the colliding wind scenario. Future dedicated simulations together with an extensive interferometric campaign are necessary to refine our constraints on the wind and stellar parameters of the binary, which finally will help us predict the evolutionary path of Eta Car.
[3]  oai:arXiv.org:1709.01348  [pdf] - 1602617
The wind and the magnetospheric accretion onto the T Tauri star S Coronae Australis at sub-au resolution
Comments: Accepted by A&A
Submitted: 2017-09-05
To investigate the inner regions of protoplanetary disks, we performed near-infrared interferometric observations of the classical TTauri binary system S CrA. We present the first VLTI-GRAVITY high spectral resolution ($R\sim$4000) observations of a classical TTauri binary, S CrA (composed of S CrA N and S CrA S and separated by $\sim$1.4"), combining the four 8-m telescopes in dual-field mode. Our observations in the near-infrared K-band continuum reveal a disk around each binary component, with similar half-flux radii of about 0.1 au at d$\sim$130 pc, inclinations ($i=$28$\pm$3$^o$\ and $i=$22$\pm$6$^o$), and position angles (PA=0$^o\pm$6$^o$ and PA=-2$^o\pm$12$^o$), suggesting that they formed from the fragmentation of a common disk. The S CrA N spectrum shows bright HeI and Br$\gamma$ line emission exhibiting inverse P-Cygni profiles, typically associated with infalling gas. The continuum-compensated Br$\gamma$ line visibilities of S CrA N show the presence of a compact Br$\gamma$ emitting region the radius of which is about $\sim$0.06 au, which is twice as big as the truncation radius. This component is mostly tracing a wind. Moreover, a slight radius change between the blue- and red-shifted Br$\gamma$ line components is marginally detected. The presence of an inverse P-Cygni profile in the HeI and Br$\gamma$ lines, along with the tentative detection of a slightly larger size of the blue-shifted Br$\gamma$ line component, hint at the simultaneous presence of a wind and magnetospheric accretion in S CrA N.
[4]  oai:arXiv.org:1705.02359  [pdf] - 1583169
Accretion-ejection morphology of the microquasar SS433 resolved at sub-au scale
Comments: Submitted for publication in A&A Letters, 4 pages + appendix, 4 figures. Comments welcome
Submitted: 2017-05-05
We present the first optical observation at sub-milliarcsecond (mas) scale of the microquasar SS 433 obtained with the GRAVITY instrument on the VLT interferometer. The 3.5 hour exposure reveals a rich K-band spectrum dominated by hydrogen Br$\gamma\ $ and \ion{He}{i} lines, as well as (red-shifted) emission lines coming from the jets. The K-band continuum emitting region is dominated by a marginally resolved point source ($<$ 1 mas) embedded inside a diffuse background accounting for 10\% of the total flux. The jet line positions agree well with the ones expected from the jet kinematic model, an interpretation also supported by the consistent sign (i.e. negative/positive for the receding/approaching jet component) of the phase shifts observed in the lines. The significant visibility drop across the jet lines, together with the small and nearly identical phases for all baselines, point toward a jet that is offset by less than 0.5 mas from the continuum source and resolved in the direction of propagation, with a typical size of 2 mas. The jet position angle of $\sim$80$^{\circ}$ is consistent with the expected one at the observation date. Jet emission so close to the central binary system would suggest that line locking, if relevant to explain the amplitude and stability of the 0.26c jet velocity, operates on elements heavier than hydrogen. The Br$\gamma\ $ profile is broad and double peaked. It is better resolved than the continuum and the change of the phase signal sign across the line on all baselines suggests an East-West oriented geometry alike the jet direction and supporting a (polar) disk wind origin.
[5]  oai:arXiv.org:1705.02351  [pdf] - 1996654
Sub-milliarcsecond Optical Interferometry of the HMXB BP Cru with VLTI/GRAVITY
Comments: Submitted to ApJ, 22 pages, 17 figures
Submitted: 2017-05-05
We observe the HMXB BP Cru using interferometry in the near-infrared K band with VLTI/GRAVITY. Continuum visibilities are at most partially resolved, consistent with the predicted size of the hypergiant. Differential visibility amplitude ($\Delta |V| \sim 5\%$) and phase ($\Delta \phi \sim 2 \deg$) signatures are observed across the HeI $2.059 \mu$m and Br$\gamma$ lines, the latter seen strongly in emission, unusual for the donor star's spectral type. For a baseline $B \sim 100$m, the differential phase RMS $\sim 0.2 \deg$ corresponds to an astrometric precision of $\sim 2 \mu$as. A model-independent analysis in the marginally resolved limit of interferometry reveals asymmetric and extended emission with a strong wavelength dependence. We propose geometric models based on an extended and distorted wind and/or a high density gas stream, which has long been predicted to be present in this system. The observations show that optical interferometry is now able to resolve HMXBs at the spatial scale at which accretion takes place, and therefore probe the effects of the gravitational and radiation fields of the compact object on its environment.
[6]  oai:arXiv.org:1705.02345  [pdf] - 1583163
First Light for GRAVITY: Phase Referencing Optical Interferometry for the Very Large Telescope Interferometer
GRAVITY Collaboration; Abuter, R.; Accardo, M.; Amorim, A.; Anugu, N.; Ávila, G.; Azouaoui, N.; Benisty, M.; Berger, J. P.; Blind, N.; Bonnet, H.; Bourget, P.; Brandner, W.; Brast, R.; Buron, A.; Burtscher, L.; Cassaing, F.; Chapron, F.; Choquet, É.; Clénet, Y.; Collin, C.; Foresto, V. Coudé du; de Wit, W.; de Zeeuw, P. T.; Deen, C.; Delplancke-Ströbele, F.; Dembet, R.; Derie, F.; Dexter, J.; Duvert, G.; Ebert, M.; Eckart, A.; Eisenhauer, F.; Esselborn, M.; Fédou, P.; Finger, G.; Garcia, P.; Dabo, C. E. Garcia; Lopez, R. Garcia; Gendron, E.; Genzel, R.; Gillessen, S.; Gonte, F.; Gordo, P.; Grould, M.; Grözinger, U.; Guieu, S.; Haguenauer, P.; Hans, O.; Haubois, X.; Haug, M.; Haussmann, F.; Henning, Th.; Hippler, S.; Horrobin, M.; Huber, A.; Hubert, Z.; Hubin, N.; Hummel, C. A.; Jakob, G.; Janssen, A.; Jochum, L.; Jocou, L.; Kaufer, A.; Kellner, S.; Kern, L.; Kervella, P.; Kiekebusch, M.; Klein, R.; Kok, Y.; Kolb, J.; Kulas, M.; Lacour, S.; Lapeyrère, V.; Lazareff, B.; Bouquin, J. -B. Le; Lèna, P.; Lenzen, R.; Lévêque, S.; Lippa, M.; Magnard, Y.; Mehrgan, L.; Mellein, M.; Mérand, A.; Moreno-Ventas, J.; Moulin, T.; Müller, E.; Müller, F.; Neumann, U.; Oberti, S.; Ott, T.; Pallanca, L.; Panduro, J.; Pasquini, L.; Paumard, T.; Percheron, I.; Perraut, K.; Perrin, G.; Pflüger, A.; Pfuhl, O.; Duc, T. Phan; Plewa, P. M.; Popovic, D.; Rabien, S.; Ramírez, A.; Ramos, J.; Rau, C.; Riquelme, M.; Rohloff, R. -R.; Rousset, G.; Sanchez-Bermudez, J.; Scheithauer, S.; Schöller, M.; Schuhler, N.; Spyromilio, J.; Straubmeier, C.; Sturm, E.; Suarez, M.; Tristram, K. R. W.; Ventura, N.; Vincent, F.; Waisberg, I.; Wank, I.; Weber, J.; Wieprecht, E.; Wiest, M.; Wiezorrek, E.; Wittkowski, M.; Woillez, J.; Wolff, B.; Yazici, S.; Ziegler, D.; Zins, G.
Comments: Accepted for publication in A&A, 23 pages, 23 figures, corresponding author: F. Eisenhauer <eisenhau@mpe.mpg.de>
Submitted: 2017-05-05
GRAVITY is a new instrument to coherently combine the light of the European Southern Observatory Very Large Telescope Interferometer to form a telescope with an equivalent 130 m diameter angular resolution and a collecting area of 200 m$^2$. The instrument comprises fiber fed integrated optics beam combination, high resolution spectroscopy, built-in beam analysis and control, near-infrared wavefront sensing, phase-tracking, dual beam operation and laser metrology [...]. This article gives an overview of GRAVITY and reports on the performance and the first astronomical observations during commissioning in 2015/16. We demonstrate phase tracking on stars as faint as m$_K$ ~ 10 mag, phase-referenced interferometry of objects fainter than m$_K$ ~ 15 mag with a limiting magnitude of m$_K$ ~ 17 mag, minute long coherent integrations, a visibility accuracy of better than 0.25 %, and spectro-differential phase and closure phase accuracy better than 0.5{\deg}, corresponding to a differential astrometric precision of better than 10 microarcseconds ({\mu}as). The dual-beam astrometry, measuring the phase difference of two objects with laser metrology, is still under commissioning. First observations show residuals as low as 50 {\mu}as when following objects over several months. We illustrate the instrument performance with the observations of archetypical objects for the different instrument modes. Examples include the Galactic Center supermassive black hole and its fast orbiting star S2 for phase referenced dual beam observations and infrared wavefront sensing, the High Mass X-Ray Binary BP Cru and the Active Galactic Nucleus of PDS 456 for few {\mu}as spectro-differential astrometry, the T Tauri star S CrA for a spectro-differential visibility analysis, {\xi} Tel and 24 Cap for high accuracy visibility observations, and {\eta} Car for interferometric imaging with GRAVITY.
[7]  oai:arXiv.org:1608.04888  [pdf] - 1458639
The metrology system of the VLTI instrument GRAVITY
Comments: 9 pages, 5 figures
Submitted: 2016-08-17
The VLTI instrument GRAVITY combines the beams from four telescopes and provides phase-referenced imaging as well as precision-astrometry of order 10 microarcseconds by observing two celestial objects in dual-field mode. Their angular separation can be determined from their differential OPD (dOPD) when the internal dOPDs in the interferometer are known. Here, we present the general overview of the novel metrology system which performs these measurements. The metrology consists of a three-beam laser system and a homodyne detection scheme for three-beam interference using phase-shifting interferometry in combination with lock-in amplifiers. Via this approach the metrology system measures dOPDs on a nanometer-level.
[8]  oai:arXiv.org:1503.07303  [pdf] - 970999
GRAVITY: the VLTI 4-beam combiner for narrow-angle astrometry and interferometric imaging
Comments: 8 pages, 3 figures. Proceeding of the conference "Fiber optics in astronomy IV". The follwoing authors made significant contribution regarding the work on fibers reported in this paper (ordered by institute and alphabetical order): IPAG: L. Jocou, K. Perraut; LESIA: R. Dembet, P. Fedou, S. Lacour, G. Perrin; MPE: N. Blind, F. Eisenhauer, S. Gillessen,, Y. Kok, M. Lippa
Submitted: 2015-03-25
GRAVITY is the second generation Very Large Telescope Interferometer instrument for precision narrow-angle astrometry and interferometric imaging in the Near Infra-Red (NIR). It shall provide precision astrometry of order 10 microarcseconds, and imaging capability at a few milliarcsecond resolution, and hence will revolutionise dynamical measurements of celestial objects. GRAVITY is currently in the last stages of its integration and tests in Garching at MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present here the instrument, with a particular focus on the components making use of fibres: integrated optics beam combiners, polarisation rotators, fibre differential delay lines, and the metrology.
[9]  oai:arXiv.org:1501.05822  [pdf] - 925683
The GRAVITY instrument software / High-level software
Comments: 8 pages, 7 figures, published in Proc. SPIE 9146, Optical and Infrared Interferometry IV, 91462B
Submitted: 2015-01-23
GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking, astrometric and imaging instrument for the Very Large Telescope Interferometer (VLTI). It is requiring the development of one of the most complex instrument software systems ever built for an ESO instrument. Apart from its many interfaces and interdependencies, one of the most challenging aspects is the overall performance and stability of this complex system. The three infrared detectors and the fast reflective memory network (RMN) recorder contribute a total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data per night. The detectors, the two instrument Local Control Units (LCUs) as well as the five LCUs running applications under TAC (Tools for Advanced Control) architecture, are interconnected with fast Ethernet, RMN fibers and dedicated fiber connections as well as signals for the time synchronization. Here we give a simplified overview of all subsystems of GRAVITY and their interfaces and discuss two examples of high-level applications during observations: the acquisition procedure and the gathering and merging of data to the final FITS file.
[10]  oai:arXiv.org:1412.1696  [pdf] - 904702
The fiber coupler and beam stabilization system of the GRAVITY interferometer
Comments: 14 pages, 13 figures. Proceedings of the SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-12-04
We present the installed and fully operational beam stabilization and fiber injection subsystem feeding the 2nd generation VLTI instrument GRAVITY. The interferometer GRAVITY requires an unprecedented stability of the VLTI optical train to achieve micro-arcsecond astrometry. For this purpose, GRAVITY contains four fiber coupler units, one per telescope. Each unit is equipped with actuators to stabilize the telescope beam in terms of tilt and lateral pupil displacement, to rotate the field, to adjust the polarization and to compensate atmospheric piston. A special roof-prism offers the possibility of on-axis as well as off-axis fringe tracking without changing the optical train. We describe the assembly, integration and alignment and the resulting optical quality and performance of the individual units. Finally, we present the closed-loop performance of the tip-tilt and pupil tracking achieved with the final systems in the lab.
[11]  oai:arXiv.org:1407.6660  [pdf] - 861905
GRAVITY: the Calibration Unit
Comments: 12 pages, 11 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-07-24
We present in this paper the design and characterisation of a new sub-system of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The Calibration Unit provides all functions to test and calibrate the beam combiner instrument: it creates two artificial stars on four beams, and dispose of four delay lines with an internal metrology. It also includes artificial stars for the tip-tilt and pupil guiding systems, as well as four metrology pick-up diodes, for tests and calibration of the corresponding sub-systems. The calibration unit also hosts the reference targets to align GRAVITY to the VLTI, and the safety shutters to avoid the metrology light to propagate in the VLTI-lab. We present the results of the characterisation and validtion of these differrent sub-units.
[12]  oai:arXiv.org:1407.6669  [pdf] - 861906
The GRAVITY metrology system: modeling a metrology in optical fibers
Comments: 20 pages, 19 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-07-24
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging. The laser metrology system of GRAVITY is at the heart of its astrometric mode, which must measure the distance of 2 stars with a precision of 10 micro-arcseconds. This means the metrology has to measure the optical path difference between the two beam combiners of GRAVITY to a level of 5 nm. The metrology design presents some non-common paths that have consequently to be stable at a level of 1 nm. Otherwise they would impact the performance of GRAVITY. The various tests we made in the past on the prototype give us hints on the components responsible for this error, and on their respective contribution to the total error. It is however difficult to assess their exact origin from only OPD measurements, and therefore, to propose a solution to this problem. In this paper, we present the results of a semi-empirical modeling of the fibered metrology system, relying on theoretical basis, as well as on characterisations of key components. The modeling of the metrology system regarding various effects, e.g., temperature, waveguide heating or mechanical stress, will help us to understand how the metrology behave. The goals of this modeling are to 1) model the test set-ups and reproduce the measurements (as a validation of the modeling), 2) determine the origin of the non-common path errors, and 3) propose modifications to the current metrology design to reach the required 1nm stability.
[13]  oai:arXiv.org:1212.5133  [pdf] - 606410
GRAVITY: beam stabilization and light injection subsystems
Comments: Proceedings of SPIE, Vol. 8445, id. 84451U-84451U-20
Submitted: 2012-12-20
We present design results of the 2nd generation VLTI instrument GRAVITY beam stabilization and light injection subsystems. Designed to deliver micro-arcsecond astrometry, GRAVITY requires an unprecedented stability of the VLTI optical train. To meet the astrometric requirements, we have developed a dedicated 'laser guiding system', correcting the longitudinal and lateral pupil position as well as the image jitter. The actuators for the correction are provided by four 'fiber coupler' units located in the GRAVITY cryostat. Each fiber coupler picks the light of one telescope and stabilizes the beam. Furthermore each unit provides field de-rotation, polarization analysis as well as atmospheric piston correction. Using a novel roof prism design offers the possibility of on-axis as well as off-axis fringe tracking without changing the optical path. Finally the stabilized beam is injected with minimized losses into single-mode fibers via parabolic mirrors. We present lab results of the first guiding- as well as the first fiber coupler prototype regarding the closed loop performance and the optical quality. Based on the lab results we discuss the on-sky performance of the system and the implications concerning the sensitivity of GRAVITY.
[14]  oai:arXiv.org:1209.2624  [pdf] - 1151355
GRAVITY: metrology
Comments: Proceedings of SPIE, Vol. 8445, Paper No. 8445-58, 2012
Submitted: 2012-09-12
GRAVITY is a second generation VLTI instrument, combining the light of four telescopes and two objects simultaneously. The main goal is to obtain astrometrically accurate information. Besides correctly measured stellar phases this requires the knowledge of the instrumental differential phase, which has to be measured optically during the astronomical observations. This is the purpose of a dedicated metrology system. The GRAVITY metrology covers the full optical path, from the beam combiners up to the reference points in the beam of the primary telescope mirror, minimizing the systematic uncertainties and providing a proper baseline in astrometric terms. Two laser beams with a fixed phase relation travel backward the whole optical chain, creating a fringe pattern in any plane close to a pupil. By temporal encoding the phase information can be extracted at any point by means of flux measurements with photo diodes. The reference points chosen sample the pupil at typical radii, eliminating potential systematics due differential focus. We present the final design and the performance estimate, which is in accordance with the overall requirements for GRAVITY.