sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Hauser, A. W.

Normalized to: Hauser, A.

2 article(s) in total. 9 co-authors. Median position in authors list is 4,5.

[1]  oai:arXiv.org:2006.13601  [pdf] - 2123673
Fiber positioning in microlens-fiber coupled integral field unit
Comments: 26 Pages, 18 Figures, 1 Table
Submitted: 2020-06-24
A generic fiber positioning strategy and a fabrication path are presented for microlens-fiber-coupled integral field units. It is assumed that microlens-produced micro-images are carried to the spectrograph input through step-index,multi-mode fiber, but our results apply to micro-pupil reimaging applications as well. Considered are the performance trades between the filling percentage of the fiber core with the micro-image versus throughput and observing efficiency.A merit function is defined as the product of the transmission efficiency and the etendue loss. For a hexagonal packing of spatial elements, the merit function has been found to be maximized to 94% of an ideal fiber IFU merit value (which has zero transmission loss and does not increase the etendue) with a microlens-fiber alignment (centering) tolerance of 1 um RMS. The maximum acceptable relative tilt between the fiber and the microlens face has been analyzed through optical modeling and found to be 0.3 degree RMS for input f-ratio slower than f/3.5 but it is much more relaxed for faster beams. Several options of fabricating fiber holders have been compared to identify cost-effective solutions that deliver the desired fiber positioning accuracy. Femto-second laser-drilling methods deliver holes arrayed on plates with a position and diameter accuracy of 1.5 um RMS, and with an aspect ratio of 1:10. A commercial vendor produces plates with thickness of 5 mm, but with similar (1 um RMS) positioning accuracy. Both of these techniques are found to be moderately expensive. A purely photo-lithographic technique performed at WCAM (a facility at the University of Wisconsin, Madison), in tandem with deep reactive ion etching, has been used to produce a repeatable recipe with 100% yield. Photo-lithography is more precise (0.5 um RMS) in terms of hole positioning and similar diameter accuracy (1 um RMS).
[2]  oai:arXiv.org:1105.3530  [pdf] - 559704
Rotational spectrum of molecular ion NH^+ as a probe for alpha- and m_e/m_p-variation
Comments: 8 pages, 1 figure
Submitted: 2011-05-18
We identify the molecular ion NH^+ as a potential candidate for probing variations in the fine structure constant alpha and electron-to-proton mass ratio mu. NH^+ has an anomalously low-lying excited Sigma state, being only a few hundred cm^-1 above the ground Pi state. Being a light molecule, this proximity is such that rotational levels of the respective states are highly intermixed for low angular momenta. We find that several low-frequency transitions within the collective rotational spectrum experience enhanced sensitivity to alpha- and mu-variation. This is attributable to the close proximity of the Pi and Sigma states, as well as the ensuing strong spin-orbit coupling between them. Suggestions that NH^+ may exist in interstellar space and recent predictions that trapped-ion precision spectroscopy will be adaptable to molecular ions make NH^+ a promising system for future astrophysical and laboratory studies of alpha- and mu-variation.