sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Hastings, P.

Normalized to: Hastings, P.

9 article(s) in total. 398 co-authors, from 1 to 6 common article(s). Median position in authors list is 14,0.

[1]  oai:arXiv.org:1508.03070  [pdf] - 1264215
The Mid-Infrared Instrument for the James Webb Space Telescope, VI: The Medium Resolution Spectrometer
Comments:
Submitted: 2015-08-12
We describe the design and performance of the Medium Resolution Spectrometer (MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral channels in a compact opto-mechanical layout that generates spectral images over fields of view up to 7.7 X 7.7 arcseconds in extent and at spectral resolving powers ranging from 1,300 to 3,700. Each channel includes an all-reflective integral field unit (IFU): an 'image slicer' that reformats the input field for presentation to a grating spectrometer. Two 1024 X 1024 focal plane arrays record the output spectral images with an instantaneous spectral coverage of approximately one third of the full wavelength range of each channel. The full 5 to 28.5 micron spectrum is then obtained by making three exposures using gratings and pass-band-determining filters that are selected using just two three-position mechanisms. The expected on-orbit optical performance is presented, based on testing of the MIRI Flight Model and including spectral and spatial coverage and resolution. The point spread function of the reconstructed images is shown to be diffraction limited and the optical transmission is shown to be consistent with the design expectations.
[2]  oai:arXiv.org:1508.02333  [pdf] - 1264202
The Mid-Infrared Instrument for JWST, II: Design and Build
Comments:
Submitted: 2015-08-10
The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST) provides measurements over the wavelength range 5 to 28.5 microns. MIRI has, within a single 'package', four key scientific functions: photometric imaging, coronagraphy, single-source low-spectral resolving power (R ~ 100) spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field spectroscopy. An associated cooler system maintains MIRI at its operating temperature of < 6.7 K. This paper describes the driving principles behind the design of MIRI, the primary design parameters, and their realization in terms of the 'as-built' instrument. It also describes the test program that led to delivery of the tested and calibrated Flight Model to NASA in 2012, and the confirmation after delivery of the key interface requirements.
[3]  oai:arXiv.org:1208.5780  [pdf] - 1150948
MOONS: a Multi-Object Optical and Near-infrared Spectrograph for the VLT
Comments: 9 pages, 5 figures. To appear in the proceedings of the SPIE Astronomical Instrumentation + Telescopes conference, Amsterdam, 2012
Submitted: 2012-08-28
MOONS is a new conceptual design for a Multi-Object Optical and Near-infrared Spectrograph for the Very Large Telescope (VLT), selected by ESO for a Phase A study. The baseline design consists of 1000 fibers deployable over a field of view of 500 square arcmin, the largest patrol field offered by the Nasmyth focus at the VLT. The total wavelength coverage is 0.8um-1.8um and two resolution modes: medium resolution and high resolution. In the medium resolution mode (R=4,000-6,000) the entire wavelength range 0.8um-1.8um is observed simultaneously, while the high resolution mode covers simultaneously three selected spectral regions: one around the CaII triplet (at R=8,000) to measure radial velocities, and two regions at R=20,000 one in the J-band and one in the H-band, for detailed measurements of chemical abundances. The grasp of the 8.2m Very Large Telescope (VLT) combined with the large multiplex and wavelength coverage of MOONS - extending into the near-IR - will provide the observational power necessary to study galaxy formation and evolution over the entire history of the Universe, from our Milky Way, through the redshift desert and up to the epoch of re-ionization at z>8-9. At the same time, the high spectral resolution mode will allow astronomers to study chemical abundances of stars in our Galaxy, in particular in the highly obscured regions of the Bulge, and provide the necessary follow-up of the Gaia mission. Such characteristics and versatility make MOONS the long-awaited workhorse near-IR MOS for the VLT, which will perfectly complement optical spectroscopy performed by FLAMES and VIMOS.
[4]  oai:arXiv.org:1207.0768  [pdf] - 1124573
Multi-Object Spectroscopy with the European ELT: Scientific synergies between EAGLE & EVE
Comments: 14 pages, to be published in Proc SPIE 8446: Ground-based & Airborne Instrumentation for Astronomy IV
Submitted: 2012-07-03
The EAGLE and EVE Phase A studies for instruments for the European Extremely Large Telescope (E-ELT) originated from related top-level scientific questions, but employed different (yet complementary) methods to deliver the required observations. We re-examine the motivations for a multi-object spectrograph (MOS) on the E-ELT and present a unified set of requirements for a versatile instrument. Such a MOS would exploit the excellent spatial resolution in the near-infrared envisaged for EAGLE, combined with aspects of the spectral coverage and large multiplex of EVE. We briefly discuss the top-level systems which could satisfy these requirements in a single instrument at one of the Nasmyth foci of the E-ELT.
[5]  oai:arXiv.org:1007.1587  [pdf] - 1033600
EAGLE ISS - A modular twin-channel integral-field near-IR spectrograph
Comments: 12 pages, to be published in Proc SPIE 7735: Ground-based & Airborne Instrumentation for Astronomy III
Submitted: 2010-07-09
The ISS (Integral-field Spectrograph System) has been designed as part of the EAGLE Phase A Instrument Study for the E-ELT. It consists of two input channels of 1.65x1.65 arcsec field-of-view, each reconfigured spatially by an image-slicing integral-field unit to feed a single near-IR spectrograph using cryogenic volume-phase-holographic (VPH) gratings to disperse the image spectrally. A 4k x 4k array detector array records the dispersed images. The optical design employs anamorphic magnification, image slicing, VPH gratings scanned with a novel cryo-mechanism and a three-lens camera. The mechanical implementation features IFU optics in Zerodur, a modular bench structure and a number of high-precision cryo-mechanisms.
[6]  oai:arXiv.org:1005.5123  [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.; Abergel, A.; Abreu, A.; Ade, P. A. R.; André, P.; Augueres, J. -L.; Babbedge, T.; Bae, Y.; Baillie, T.; Baluteau, J. -P.; Barlow, M. J.; Bendo, G.; Benielli, D.; Bock, J. J.; Bonhomme, P.; Brisbin, D.; Brockley-Blatt, C.; Caldwell, M.; Cara, C.; Castro-Rodriguez, N.; Cerulli, R.; Chanial, P.; Chen, S.; Clark, E.; Clements, D. L.; Clerc, L.; Coker, J.; Communal, D.; Conversi, L.; Cox, P.; Crumb, D.; Cunningham, C.; Daly, F.; Davis, G. R.; De Antoni, P.; Delderfield, J.; Devin, N.; Di Giorgio, A.; Didschuns, I.; Dohlen, K.; Donati, M.; Dowell, A.; Dowell, C. D.; Duband, L.; Dumaye, L.; Emery, R. J.; Ferlet, M.; Ferrand, D.; Fontignie, J.; Fox, M.; Franceschini, A.; Frerking, M.; Fulton, T.; Garcia, J.; Gastaud, R.; Gear, W. K.; Glenn, J.; Goizel, A.; Griffin, D. K.; Grundy, T.; Guest, S.; Guillemet, L.; Hargrave, P. C.; Harwit, M.; Hastings, P.; Hatziminaoglou, E.; Herman, M.; Hinde, B.; Hristov, V.; Huang, M.; Imhof, P.; Isaak, K. J.; Israelsson, U.; Ivison, R. J.; Jennings, D.; Kiernan, B.; King, K. J.; Lange, A. E.; Latter, W.; Laurent, G.; Laurent, P.; Leeks, S. J.; Lellouch, E.; Levenson, L.; Li, B.; Li, J.; Lilienthal, J.; Lim, T.; Liu, J.; Lu, N.; Madden, S.; Mainetti, G.; Marliani, P.; McKay, D.; Mercier, K.; Molinari, S.; Morris, H.; Moseley, H.; Mulder, J.; Mur, M.; Naylor, D. A.; Nguyen, H.; O'Halloran, B.; Oliver, S.; Olofsson, G.; Olofsson, H. -G.; Orfei, R.; Page, M. J.; Pain, I.; Panuzzo, P.; Papageorgiou, A.; Parks, G.; Parr-Burman, P.; Pearce, A.; Pearson, C.; Pérez-Fournon, I.; Pinsard, F.; Pisano, G.; Podosek, J.; Pohlen, M.; Polehampton, E. T.; Pouliquen, D.; Rigopoulou, D.; Rizzo, D.; Roseboom, I. G.; Roussel, H.; Rowan-Robinson, M.; Rownd, B.; Saraceno, P.; Sauvage, M.; Savage, R.; Savini, G.; Sawyer, E.; Scharmberg, C.; Schmitt, D.; Schneider, N.; Schulz, B.; Schwartz, A.; Shafer, R.; Shupe, D. L.; Sibthorpe, B.; Sidher, S.; Smith, A.; Smith, A. J.; Smith, D.; Spencer, L.; Stobie, B.; Sudiwala, R.; Sukhatme, K.; Surace, C.; Stevens, J. A.; Swinyard, B. M.; Trichas, M.; Tourette, T.; Triou, H.; Tseng, S.; Tucker, C.; Turner, A.; Vaccari, M.; Valtchanov, I.; Vigroux, L.; Virique, E.; Voellmer, G.; Walker, H.; Ward, R.; Waskett, T.; Weilert, M.; Wesson, R.; White, G. J.; Whitehouse, N.; Wilson, C. D.; Winter, B.; Woodcraft, A. L.; Wright, G. S.; Xu, C. K.; Zavagno, A.; Zemcov, M.; Zhang, L.; Zonca, E.
Comments: Accepted for publication in Astronomy & Astrophyics (Herschel first results special issue)
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a field of view of 4' x 8', observed simultaneously in the three spectral bands. Its main operating mode is scan-mapping, whereby the field of view is scanned across the sky to achieve full spatial sampling and to cover large areas if desired. The spectrometer has an approximately circular field of view with a diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25 GHz by changing the stroke length of the FTS scan mirror. Its main operating mode involves a fixed telescope pointing with multiple scans of the FTS mirror to acquire spectral data. For extended source measurements, multiple position offsets are implemented by means of an internal beam steering mirror to achieve the desired spatial sampling and by rastering of the telescope pointing to map areas larger than the field of view. The SPIRE instrument consists of a cold focal plane unit located inside the Herschel cryostat and warm electronics units, located on the spacecraft Service Module, for instrument control and data handling. Science data are transmitted to Earth with no on-board data compression, and processed by automatic pipelines to produce calibrated science products. The in-flight performance of the instrument matches or exceeds predictions based on pre-launch testing and modelling: the photometer sensitivity is comparable to or slightly better than estimated pre-launch, and the spectrometer sensitivity is also better by a factor of 1.5-2.
[7]  oai:arXiv.org:0907.3610  [pdf] - 1003008
HARP/ACSIS: A submillimetre spectral imaging system on the James Clerk Maxwell Telescope
Comments: MNRAS Accepted 2009 July 2. 18 pages, 25 figures and 6 tables
Submitted: 2009-07-21
This paper describes a new Heterodyne Array Receiver Programme (HARP) and Auto-Correlation Spectral Imaging System (ACSIS) that have recently been installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The 16-element focal-plane array receiver, operating in the submillimetre from 325 to 375 GHz, offers high (three-dimensional) mapping speeds, along with significant improvements over single-detector counterparts in calibration and image quality. Receiver temperatures are $\sim$120 K across the whole band and system temperatures of $\sim$300K are reached routinely under good weather conditions. The system includes a single-sideband filter so these are SSB figures. Used in conjunction with ACSIS, the system can produce large-scale maps rapidly, in one or more frequency settings, at high spatial and spectral resolution. Fully-sampled maps of size 1 square degree can be observed in under 1 hour. The scientific need for array receivers arises from the requirement for programmes to study samples of objects of statistically significant size, in large-scale unbiased surveys of galactic and extra-galactic regions. Along with morphological information, the new spectral imaging system can be used to study the physical and chemical properties of regions of interest. Its three-dimensional imaging capabilities are critical for research into turbulence and dynamics. In addition, HARP/ACSIS will provide highly complementary science programmes to wide-field continuum studies, and produce the essential preparatory work for submillimetre interferometers such as the SMA and ALMA.
[8]  oai:arXiv.org:astro-ph/0605484  [pdf] - 82171
A multi-object, multi-field spectrometer and imager for a European ELT
Comments: 9 pages, 8 figures, to be published in Proc. SPIE 6269, Ground-based & Airborne Instrumentation for Astronomy
Submitted: 2006-05-19
One of the highlights of the European ELT Science Case book is the study of resolved stellar populations, potentially out to the Virgo Cluster of galaxies. A European ELT would enable such studies in a wide range of unexplored distant environments, in terms of both galaxy morphology and metallicity. As part of a small study, a revised science case has been used to shape the conceptual design of a multi-object, multi-field spectrometer and imager (MOMSI). Here we present an overview of some key science drivers, and how to achieve these with elements such as multiplex, AO-correction, pick-off technology and spectral resolution.
[9]  oai:arXiv.org:astro-ph/0202306  [pdf] - 47800
Multiple Integral Field Spectroscopy
Comments: 8 pages, 5 colour figures. To be published in the Proceedings of the ESO Workshop Scientific Drivers for ESO Future VLT/VLTI Instrumentation
Submitted: 2002-02-15
Integral-field spectroscopy is the most effective method of exploiting the superb image quality of the ESO-VLT, allowing complex astrophysical processes to be probed on the angular scales currently accessible only for imaging data, but with the addition of information in the spectral dimension. We discuss science drivers and requirements for multiple deployable integral fields for spectroscopy in the near-infrared. We then describe a fully modular instrument concept which can achieve such a capability over a 5-10' field with up to 32 deployable integral fields, each fully cryogenic with 1-2.5 micron coverage at a spectral resolution of ~3000, each with a 4" x 4" field of view sampled at 0.2"/pixel to take advantage of the best K-band seeing.