Normalized to: Hartner, G.
[1]
oai:arXiv.org:1906.06093 [pdf] - 1900447
Calibration of X-ray telescope prototypes at PANTER
Liao, Ying-Yu;
Shen, Zheng-Xiang;
Yu, Jun;
Huang, Qiu-Shi;
Ma, Bin;
Zhang, Zhong;
Wang, Xiao-Qiang;
Wang, Kun;
Xie, Chun;
Burwitz, Vadim;
Hartner, Gisela;
La Caria, Marlis-Madeleine;
Pelliciari, Carlo;
Wang, Zhan-Shan
Submitted: 2019-06-14
We report a ground X-ray calibration of two X-ray telescope prototypes at the
PANTER X-ray Test Facility, of the Max-Planck-Institute for Extraterrestrial
Physics, in Neuried, Germany. The X-ray telescope prototypes were developed by
the Institute of Precision Optical Engineering (IPOE) of Tongji University, in
a conical Wolter-I configuration, using thermal glass slumping technology.
Prototype #1 with 3 layers and Prototype #2 with 21 layers were tested to
assess the prototypes' on-axis imaging performance. The measurement of
Prototype #1 indicates a Half Power Diameter (HPD) of 82" at 1.49 keV. As for
Prototype #2, we performed more comprehensive measurements of on-axis angular
resolution and effective area at several energies ranging from 0.5-10 keV. The
HPD and effective area are 111" and 39 cm^2 at 1.49 keV, respectively, at which
energy the on-axis performance of the prototypes is our greatest concern.
[2]
oai:arXiv.org:1603.04839 [pdf] - 1374470
Line Spread Functions of Blazed Off-Plane Gratings Operated in the
Littrow Mounting
DeRoo, Casey T.;
McEntaffer, Randall L.;
Miles, Drew M.;
Peterson, Thomas J.;
Marlowe, Hannah;
Tutt, James H.;
Donovan, Benjamin D.;
Menz, Benedikt;
Burwitz, Vadim;
Hartner, Gisela;
Allured, Ryan;
Smith, Randall K.;
Gunther, Ramses;
Yanson, Alex;
Vacanti, Giuseppe;
Ackermann, Marcelo
Submitted: 2016-03-15
Future soft X-ray (10 - 50 Angstrom) spectroscopy missions require higher
effective areas and resolutions to perform critical science that cannot be done
by instruments on current missions. An X-ray grating spectrometer employing
off-plane reflection gratings would be capable of meeting these performance
criteria. Off-plane gratings with blazed groove facets operated in the Littrow
mounting can be used to achieve excellent throughput into orders achieving high
resolutions. We have fabricated two off-plane gratings with blazed groove
profiles via a technique which uses commonly available microfabrication
processes, is easily scaled for mass production, and yields gratings customized
for a given mission architecture. Both fabricated gratings were tested in the
Littrow mounting at the Max-Planck-Institute for extraterrestrial Physics
PANTER X-ray test facility to assess their performance. The line spread
functions of diffracted orders were measured, and a maximum resolution of 800
$\pm$ 20 is reported. In addition, we also observe evidence of a `blaze' effect
from measurements of relative efficiencies of the diffracted orders.
[3]
oai:arXiv.org:1509.02298 [pdf] - 1273356
Profile reconstruction of grazing-incidence X-ray mirrors from
intra-focal X-ray full imaging
Spiga, D.;
Basso, S.;
Bavdaz, M.;
Burwitz, V.;
Civitani, M.;
Citterio, O.;
Ghigo, M.;
Hartner, G.;
Menz, B.;
Pareschi, G.;
Proserpio, L.;
Salmaso, B.;
Tagliaferri, G.;
Wille, E.
Submitted: 2015-09-08
The optics of a number of future X-ray telescopes will have very long focal
lengths (10 - 20 m), and will consist of a number of nested/stacked thin,
grazing-incidence mirrors. The optical quality characterization of a real
mirror can be obtained via profile metrology, and the Point Spread Function of
the mirror can be derived via one of the standard computation methods. However,
in practical cases it can be difficult to access the optical surfaces of
densely stacked mirror shells, after they have been assembled, using the
widespread metrological tools. For this reason, the assessment of the imaging
resolution of a system of mirrors is better obtained via a direct,
full-illumination test in X-rays. If the focus cannot be reached, an
intra-focus test can be performed, and the image can be compared with the
simulation results based on the metrology, if available. However, until today
no quantitative information was extracted from a full-illumination, intra-focal
exposure. In this work we show that, if the detector is located at an optimal
distance from the mirror, the intensity variations of the intra-focal,
full-illumination image in single reflection can be used to reconstruct the
profile of the mirror surface, without the need of a wavefront sensor. The
Point Spread Function can be subsequently computed from the reconstructed
mirror shape. We show the application of this method to an intra-focal (8 m
distance from mirror) test performed at PANTER on an optical module prototype
made of hot-slumped glass foils with a 20 m focal length, from which we could
derive an expected imaging quality near 16 arcsec HEW.
[4]
oai:arXiv.org:1503.05809 [pdf] - 968633
Performance Testing of a Novel Off-plane Reflection Grating and Silicon
Pore Optic Spectrograph at PANTER
Marlowe, Hannah;
McEntaffer, Randall L.;
Allured, Ryan;
DeRoo, Casey;
Miles, Drew M.;
Donovan, Benjamin D.;
Tutt, James H.;
Burwitz, Vadim;
Menz, Benedikt;
Hartner, Gisela D.;
Smith, Randall K.;
Günther, Ramses;
Yanson, Alex;
Vacanti, Giuseppe;
Ackermann, Marcelo
Submitted: 2015-03-19
An X-ray spectrograph consisting of radially ruled off-plane reflection
gratings and silicon pore optics was tested at the Max Planck Institute for
extraterrestrial Physics PANTER X-ray test facility. The silicon pore optic
(SPO) stack used is a test module for the Arcus small explorer mission, which
will also feature aligned off-plane reflection gratings. This test is the first
time two off-plane gratings were actively aligned to each other and with a SPO
to produce an overlapped spectrum. The gratings were aligned using an active
alignment module which allows for the independent manipulation of subsequent
gratings to a reference grating in three degrees of freedom using picomotor
actuators which are controllable external to the test chamber. We report the
line spread functions of the spectrograph and the actively aligned gratings,
and plans for future development.
[5]
oai:arXiv.org:1403.7200 [pdf] - 1208656
The imaging properties of the Gas Pixel Detector as a focal plane
polarimeter
Fabiani, S.;
Costa, E.;
Del Monte, E.;
Muleri, F.;
Soffitta, P.;
Rubini, A.;
Bellazzini, R.;
Brez, A.;
de Ruvo, L.;
Minuti, M.;
Pinchera, M.;
Sgrò, C.;
Spandre, G.;
Spiga, D.;
Tagliaferri, G.;
Pareschi, G.;
Basso, S.;
Citterio, O.;
Burwitz, V.;
Burkert, W.;
Menz, B.;
Hartner, G.
Submitted: 2014-03-27
X-rays are particularly suited to probe the physics of extreme objects.
However, despite the enormous improvements of X-ray Astronomy in imaging,
spectroscopy and timing, polarimetry remains largely unexplored. We propose the
photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate
to fill the gap of more than thirty years of lack of measurements. The GPD, in
the focus of a telescope, will increase the sensitivity of orders of magnitude.
Moreover, since it can measure the energy, the position, the arrival time and
the polarization angle of every single photon, allows to perform polarimetry of
subsets of data singled out from the spectrum, the light curve or the image of
source. The GPD has an intrinsic very fine imaging capability and in this work
we report on the calibration campaign carried out in 2012 at the PANTER X-ray
test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of
Garching (Germany) in which, for the first time, we coupled it to a JET-X
optics module with a focal length of 3.5 m and an angular resolution of 18
arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray
Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small
mission. We derived the imaging and polarimetric performance for extended
sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the
XIPE configuration, discussing also possible improvements by coupling the
detector with advanced optics, having finer angular resolution and larger
effective area, to study with more details extended objects.
[6]
oai:arXiv.org:1311.2220 [pdf] - 786443
Re-testing the JET-X Flight Module No. 2 at the PANTER facility
Spiga, Daniele;
Tagliaferri, Gianpiero;
Soffitta, Paolo;
Citterio, Oberto;
Basso, Stefano;
Bellazzini, Ronaldo;
Brez, Alessandro;
Burkert, Wolfgang;
Burwitz, Vadim;
Costa, Enrico;
de Ruvo, Luca;
Del Monte, Ettore;
Fabiani, Sergio;
Hartner, Gisela;
Menz, Benedikt;
Minuti, Massimo;
Muleri, Fabio;
Pareschi, Giovanni;
Pinchera, Michele;
Rubini, Alda;
Sgrò, Carmelo;
Spandre, Gloria
Submitted: 2013-11-09, last modified: 2014-02-18
The Joint European X-ray Telescope (JET-X) was the core instrument of the
Russian Spectrum-X-gamma space observatory. It consisted of two identical soft
X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured
angular resolution of nearly 15 arcsec. Soon after the payload completion, the
mission was cancelled and the two optical flight modules (FM) were brought to
the Brera Astronomical Observatory where they had been manufactured. After 16
years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray
facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel
Detector (GPD) with polarimetric capabilities in the focal plane of the FM2.
The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In
the first phase of the test campaign, we have re-tested the FM2 at PANTER to
have an up-to-date characterization in terms of angular resolution and
effective area, while in the second part of the test the GPD has been placed in
the focal plane of the FM2. In this paper we report the results of the tests of
the sole FM2, using an unpolarized X-ray source, comparing the results with the
calibration done in 1996.
[7]
oai:arXiv.org:0903.2483 [pdf] - 22372
Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase
A Study
Tagliaferri, G.;
Basso, S.;
Borghi, G.;
Burkert, W.;
Citterio, O.;
Civitani, M.;
Conconi, P.;
Cotroneo, V.;
Freyberg, M.;
Garoli, D.;
Gorenstein, P.;
Hartner, G.;
Mattarello, V.;
Orlandi, A.;
Pareschi, G.;
Romaine, S.;
Spiga, D.;
Valsecchi, G.;
Vernani, D.
Submitted: 2009-03-13
Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong
improvement both in sensitivity and angular resolution compared to all
instruments that have operated so far above 10 keV. The superb hard X-ray
imaging capability will be guaranteed by a mirror module of 100 electroformed
Nickel shells with a multilayer reflecting coating. Here we will describe the
technogical development and solutions adopted for the fabrication of the mirror
module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec
from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A,
terminated at the end of 2008, we have developed three engineering models with
two, two and three shells, respectively. The most critical aspects in the
development of the Simbol-X mirrors are i) the production of the 100 mandrels
with very good surface quality within the timeline of the mission; ii) the
replication of shells that must be very thin (a factor of 2 thinner than those
of XMM-Newton) and still have very good image quality up to 80 keV; iii) the
development of an integration process that allows us to integrate these very
thin mirrors maintaining their intrinsic good image quality. The Phase A study
has shown that we can fabricate the mandrels with the needed quality and that
we have developed a valid integration process. The shells that we have produced
so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and
effective area. However, we still need to make some improvements to reach the
requirements. We will briefly present these results and discuss the possible
improvements that we will investigate during phase B.
[8]
oai:arXiv.org:astro-ph/0508071 [pdf] - 74960
The Swift X-ray Telescope
Burrows, David N.;
Hill, J. E.;
Nousek, J. A.;
Kennea, J. A.;
Wells, A.;
Osborne, J. P.;
Abbey, A. F.;
Beardmore, A.;
Mukerjee, K;
Short, A. D. T.;
Chincarini, G.;
Campana, S.;
Citterio, O.;
Moretti, A.;
Pagani, C.;
Tagliaferri, G.;
Giommi, P.;
Capalbi, M.;
Tamburelli, F.;
Angelini, L.;
Cusumano, G.;
Braeuninger, H. W.;
Burkert, W.;
Hartner, G. D.
Submitted: 2005-08-02
The Swift Gamma-Ray Explorer is designed to make prompt multiwavelength
observations of Gamma-Ray Bursts (GRBs) and GRB afterglows. The X-ray Telescope
(XRT) enables Swift to determine GRB positions with a few arcseconds accuracy
within 100 seconds of the burst onset.
The XRT utilizes a mirror set built for JET-X and an XMM/EPIC MOS CCD
detector to provide a sensitive broad-band (0.2-10 keV) X-ray imager with
effective area of > 120 cm^2 at 1.5 keV, field of view of 23.6 x 23.6
arcminutes, and angular resolution of 18 arcseconds (HPD). The detection
sensitivity is 2x10^-14 erg cm^-2 s^-1 in 10^4 seconds. The instrument is
designed to provide automated source detection and position reporting within 5
seconds of target acquisition. It can also measure the redshifts of GRBs with
Fe line emission or other spectral features. The XRT operates in an
auto-exposure mode, adjusting the CCD readout mode automatically to optimize
the science return for each frame as the source intensity fades. The XRT will
measure spectra and lightcurves of the GRB afterglow beginning about a minute
after the burst and will follow each burst for days or weeks.
[9]
oai:arXiv.org:astro-ph/0407637 [pdf] - 66479
Improving XMM-Newton EPIC pn data at low energies: method and
application to the Vela SNR
Dennerl, Konrad;
Aschenbach, Bernd;
Briel, Ulrich G.;
Brunner, Hermann;
Burwitz, Vadim;
Englhauser, Jakob;
Freyberg, Michael J.;
Haberl, Frank;
Hartner, Gisela;
Iyudin, Anatoli F.;
Kendziorra, Eckhard;
Meidinger, Norbert;
Pfeffermann, Elmar;
Pietsch, Wolfgang;
Strueder, Lothar;
Zavlin, Vyacheslav E.
Submitted: 2004-07-30
High quantum efficiency over a broad spectral range is one of the main
properties of the EPIC pn camera on-board XMM-Newton. The quantum efficiency
rises from ~75% at 0.2 keV to ~100% at 1 keV, stays close to 100% until 8 keV,
and is still ~90% at 10 keV. The EPIC pn camera is attached to an X-ray
telescope which has the highest collecting area currently available, in
particular at low energies (more than 1400 cm2 between 0.1 and 2.0 keV). Thus,
this instrument is very sensitive to the low-energy X-ray emission. However,
X-ray data at energies below ~0.2 keV are considerably affected by detector
effects, which become more and more important towards the lowest transmitted
energies. In addition to that, pixels which have received incorrect offsets
during the calculation of the offset map at the beginning of each observation,
show up as bright patches in low-energy images. Here we describe a method which
is not only capable of suppressing the contaminations found at low energies,
but which also improves the data quality throughout the whole EPIC pn spectral
range. This method is then applied to data from the Vela supernova remnant.
[10]
oai:arXiv.org:astro-ph/0011438 [pdf] - 39445
The first broad-band X-ray images and spectra of the 30 Doradus region
in the LMC
Dennerl, K.;
Haberl, F.;
Aschenbach, B.;
Briel, U. G.;
Balasini, M.;
Braeuninger, H.;
Burkert, W.;
Hartmann, R.;
Hartner, G.;
Hasinger, G.;
Kemmer, J.;
Kendziorra, E.;
Kirsch, M.;
Krause, N.;
Kuster, M.;
Lumb, D.;
Massa, P.;
Meidinger, N.;
Pfeffermann, E.;
Pietsch, W.;
Reppin, C.;
Soltau, H.;
Staubert, R.;
Strueder, L.;
Truemper, J.;
Turner, M.;
Villa, G.;
Zavlin, V. E.
Submitted: 2000-11-23
We present the XMM-Newton first light image, taken in January 2000 with the
EPIC pn camera during the instrument's commissioning phase, when XMM-Newton was
pointing towards the Large Magellanic Cloud (LMC). The field is rich in
different kinds of X-ray sources: point sources, supernova remnants (SNRs) and
diffuse X-ray emission from LMC interstellar gas. The observations are of
unprecedented sensitivity, reaching a few 10^32 erg/s for point sources in the
LMC. We describe how these data sets were analysed and discuss some of the
spectroscopic results. For the SNR N157B the power law spectrum is clearly
steeper than previously determined from ROSAT and ASCA data. The existence of a
significant thermal component is evident and suggests that N157B is not a
Crab-like but a composite SNR. Most puzzling is the spectrum of the LMC hot
interstellar medium, which indicates a significant overabundance of Ne and Mg
of a few times solar.
[11]
oai:arXiv.org:astro-ph/0001034 [pdf] - 1454912
First Light Measurements of Capella with the Low Energy Transmission
Grating Spectrometer aboard the Chandra X-ray Observatory
Brinkman, A. C.;
Gunsing, C. J. T.;
Kaastra, J. S.;
van der Meer, R. L. J.;
Mewe, R.;
Paerels, F.;
Raassen, A. J. J.;
van Rooijen, J. J.;
Bräuninger, H.;
Burkert, W.;
Burwitz, V.;
Hartner, G.;
Predehl, P.;
Ness, J. -U.;
Schmitt, J. H. M. M.;
Drake, J. J.;
Johnson, O.;
Juda, M.;
Kashyap, V.;
Murray, S. S.;
Pease, D.;
Ratzlaff, P.;
Wargelin, B. J.
Submitted: 2000-01-04
We present the first X-ray spectrum obtained by the Low Energy Transmission
Grating Spectrometer (LETGS) aboard the Chandra X-ray Observatory. The spectrum
is of Capella and covers a wavelength range of 5-175 A (2.5-0.07 keV). The
measured wavelength resolution, which is in good agreement with ground
calibration, is $\Delta \lambda \simeq$ 0.06 A (FWHM). Although in-flight
calibration of the LETGS is in progress, the high spectral resolution and
unique wavelength coverage of the LETGS are well demonstrated by the results
from Capella, a coronal source rich in spectral emission lines. While the
primary purpose of this letter is to demonstrate the spectroscopic potential of
the LETGS, we also briefly present some preliminary astrophysical results. We
discuss plasma parameters derived from line ratios in narrow spectral bands,
such as the electron density diagnostics of the He-like triplets of carbon,
nitrogen, and oxygen, as well as resonance scattering of the strong Fe XVII
line at 15.014 A.
[12]
oai:arXiv.org:astro-ph/9909315 [pdf] - 108351
The ROSAT All-Sky Survey Bright Source Catalogue
Voges, Wolfgang;
Aschenbach, Bernd;
Boller, Thomas;
Braeuninger, Heinrich;
Briel, Ulrich;
Burkert, Wolfgang;
Dennerl, Konrad;
Englhauser, Jakob;
Gruber, Rainer;
Haberl, Frank;
Hartner, Gisela;
Hasinger, Guenther;
Pfeffermann, Elmar;
Pietsch, Wolfgang;
Predehl, Peter;
Rosso, Cristina;
Schmitt, Juergen H. M. M.;
Truemper, Joachim;
Zimmermann, Hans-Ulrich
Submitted: 1999-09-17, last modified: 1999-09-20
We present the ROSAT All-Sky Survey Bright Source Catalogue (RASS-BSC,
revision 1RXS) derived from the all-sky survey performed during the first half
year (1990/91) of the ROSAT mission. 18,811 sources are catalogued (i) down to
a limiting ROSAT PSPC count-rate of 0.05 cts/s in the 0.1-2.4 keV energy band,
(ii) with a detection likelihood of at least 15 and (iii) at least 15 source
counts. The 18,811 sources underwent both an automatic validation and an
interactive visual verification process in which for 94% of the sources the
results of the standard processing were confirmed. The remaining 6% have been
analyzed using interactive methods and these sources have been flagged. Flags
are given for (i) nearby sources; (ii) sources with positional errors; (iii)
extended sources; (iv) sources showing complex emission structures; and (v)
sources which are missed by the standard analysis software. Broad band (0.1-2.4
keV) images are available for sources flagged by (ii), (iii) and (iv). For each
source the ROSAT name, position in equatorial coordinates, positional error,
source count-rate and error, background count-rate, exposure time, two
hardness-ratios and errors, extent and likelihood of extent, likelihood of
detection, and the source extraction radius are provided. At a brightness limit
of 0.1 cts/s (8,547 sources) the catalogue represents a sky coverage of 92%.
The RASS-BSC, the table of possible identification candidates, and the broad
band images are available in electronic form (Voges et al. 1996a) via
http://wave.xray.mpe.mpg.de/rosat/catalogues/rass-bsc .