sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Haro, Miguel Sofo

Normalized to: Haro, M.

13 article(s) in total. 187 co-authors, from 1 to 12 common article(s). Median position in authors list is 28,0.

[1]  oai:arXiv.org:2004.11378  [pdf] - 2083499
SENSEI: Direct-Detection Results on sub-GeV Dark Matter from a New Skipper-CCD
Comments: 5 pages, 4 figures, 1 table + Supplemental Materials (4 pages, 6 figures) + References
Submitted: 2020-04-23
We present the first direct-detection search for eV-to-GeV dark matter using a new ~2-gram high-resistivity Skipper-CCD from a dedicated fabrication batch that was optimized for dark-matter searches. Using 24 days of data acquired in the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the lowest rates in silicon detectors of events containing one, two, three, or four electrons, and achieve world-leading sensitivity for a large range of sub-GeV dark matter masses. Data taken with different thicknesses of the detector shield suggest a correlation between the rate of high-energy tracks and the rate of single-electron events previously classified as "dark current." We detail key characteristics of the new Skipper-CCDs, which augur well for the planned construction of the ~100-gram SENSEI experiment at SNOLAB.
[2]  oai:arXiv.org:2004.07599  [pdf] - 2078813
Low Threshold Acquisition controller for Skipper CCDs
Comments:
Submitted: 2020-04-16
The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.
[3]  oai:arXiv.org:1906.02200  [pdf] - 2000205
Exploring low-energy neutrino physics with the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)
Comments: Updated to match the version accepted for publication in Physical Review D
Submitted: 2019-06-05, last modified: 2019-10-10
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) uses low-noise fully depleted charge-coupled devices (CCDs) with the goal of measuring low-energy recoils from coherent elastic scattering (CE$\nu$NS) of reactor antineutrinos with silicon nuclei and testing nonstandard neutrino interactions (NSI). We report here the first results of the detector array deployed in 2016, considering an active mass 47.6 g (8 CCDs), which is operating at a distance of 30 m from the core of the Angra 2 nuclear reactor, with a thermal power of 3.8 GW. A search for neutrino events is performed by comparing data collected with reactor on (2.1 kg-day) and reactor off (1.6 kg-day). The results show no excess in the reactor-on data, reaching the world record sensitivity down to recoil energies of about 1 keV (0.1 keV electron-equivalent). A 95% confidence level limit for new physics is established at an event rate of 40 times the one expected from the standard model at this energy scale. The results presented here provide a new window to low-energy neutrino physics, allowing one to explore for the first time the energies accessible through the low threshold of CCDs. They will lead to new constrains on NSI from the CE$\nu$NS of antineutrinos from nuclear reactors.
[4]  oai:arXiv.org:1901.10478  [pdf] - 1875312
SENSEI: Direct-Detection Constraints on Sub-GeV Dark Matter from a Shallow Underground Run Using a Prototype Skipper-CCD
Comments: 5 pages, submitted to PRL
Submitted: 2019-01-29
We present new direct-detection constraints on eV-to-GeV dark matter interacting with electrons using a prototype detector of the Sub-Electron-Noise Skipper-CCD Experimental Instrument. The results are based on data taken in the MINOS cavern at the Fermi National Accelerator Laboratory. We focus on data obtained with two distinct readout strategies. For the first strategy, we read out the Skipper-CCD continuously, accumulating an exposure of 0.177 gram-days. While we observe no events containing three or more electrons, we find a large one- and two-electron background event rate, which we attribute to spurious events induced by the amplifier in the Skipper-CCD readout stage. For the second strategy, we take five sets of data in which we switch off all amplifiers while exposing the Skipper-CCD for 120k seconds, and then read out the data through the best prototype amplifier. We find a one-electron event rate of (3.51 +- 0.10) x 10^(-3) events/pixel/day, which is almost two orders of magnitude lower than the one-electron event rate observed in the continuous-readout data, and a two-electron event rate of (3.18 +0.86 -0.55) x 10^(-5) events/pixel/day. We again observe no events containing three or more electrons, for an exposure of 0.069 gram-days. We use these data to derive world-leading constraints on dark matter-electron scattering for masses between 500 keV to 5 MeV, and on dark-photon dark matter being absorbed by electrons for a range of masses below 12.4 eV.
[5]  oai:arXiv.org:1804.00088  [pdf] - 1749256
SENSEI: First Direct-Detection Constraints on sub-GeV Dark Matter from a Surface Run
Comments: 5 pages + references, 4 figures, 1 table. V2 has additional references and minor clarifications. Published in PRL
Submitted: 2018-03-30, last modified: 2018-09-11
The Sub-Electron-Noise Skipper CCD Experimental Instrument (SENSEI) uses the recently developed Skipper-CCD technology to search for electron recoils from the interaction of sub-GeV dark matter particles with electrons in silicon. We report first results from a prototype SENSEI detector, which collected 0.019 gram-days of commissioning data above ground at Fermi National Accelerator Laboratory. These commissioning data are sufficient to set new direct-detection constraints for dark matter particles with masses between ~500 keV and 4 MeV. Moreover, since these data were taken on the surface, they disfavor previously allowed strongly interacting dark matter particles with masses between ~500 keV and a few hundred MeV. We discuss the implications of these data for several dark matter candidates, including one model proposed to explain the anomalously large 21-cm signal observed by the EDGES Collaboration. SENSEI is the first experiment dedicated to the search for electron recoils from dark matter, and these results demonstrate the power of the Skipper-CCD technology for dark matter searches.
[6]  oai:arXiv.org:1611.03066  [pdf] - 1561044
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB
Comments: 5 pages, 5 figures
Submitted: 2016-11-09, last modified: 2017-04-11
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $\kappa$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.
[7]  oai:arXiv.org:1607.07410  [pdf] - 1511851
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
Comments: 11 pages, 11 figures
Submitted: 2016-07-25, last modified: 2016-11-09
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.
[8]  oai:arXiv.org:1605.02151  [pdf] - 1403219
The Latin American Giant Observatory: Contributions to the 34th International Cosmic Ray Conference (ICRC 2015)
Comments: 9 proceedings, the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands; in PoS(ICRC2015)
Submitted: 2016-05-07
The Latin American Giant Observatory (LAGO) is an extended cosmic ray observatory composed by a network of water-Cherenkov detectors spanning over different sites located at significantly different altitudes (from sea level up to more than $5000$\,m a.s.l.) and latitudes across Latin America, covering a huge range of geomagnetic rigidity cut-offs and atmospheric absorption/reaction levels. This detection network is designed to measure the temporal evolution of the radiation flux at ground level with extreme detail. The LAGO project is mainly oriented to perform basic research in three branches: high energy phenomena, space weather and atmospheric radiation at ground level. LAGO is built and operated by the LAGO Collaboration, a non-centralized collaborative union of more than 30 institutions from ten countries. These are the contributions of the LAGO Collaboration to the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands
[9]  oai:arXiv.org:1510.00044  [pdf] - 1323491
Status of the DAMIC direct dark matter search experiment
Comments: Talk presented CIPANP2015. 9 pages, PDFLaTeX, 11 PDF figures, econfmacros LaTeX file
Submitted: 2015-09-30, last modified: 2015-12-08
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This contribution discusses the installation progress, new calibration efforts near the threshold, a preliminary result with 2014 data, and the prospects for physics results after one year of data taking.
[10]  oai:arXiv.org:1510.02126  [pdf] - 1449866
The DAMIC dark matter experiment
Comments: Presented at the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands
Submitted: 2015-10-07
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c$^2$. Previous results have demonstrated the potential of this technology, motivating the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. In this contribution, the mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds will be discussed, as well as physics results after one year of data taking.
[11]  oai:arXiv.org:1506.02562  [pdf] - 1505514
Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment
Comments: 18 pages, 20 figures
Submitted: 2015-06-08, last modified: 2015-07-09
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $\alpha$ and $\beta$ particles. Uranium and thorium contamination in the CCD bulk was measured through $\alpha$ spectroscopy, with an upper limit on the $^{238}$U ($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also searched for pairs of spatially correlated electron tracks separated in time by up to tens of days, as expected from $^{32}$Si-$^{32}$P or $^{210}$Pb-$^{210}$Bi sequences of $\beta$ decays. The decay rate of $^{32}$Si was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was obtained independently by $\alpha$ spectroscopy and the $\beta$ decay sequence search. These levels of radioactive contamination are sufficiently low for the successful operation of CCDs in the forthcoming 100 g DAMIC detector.
[12]  oai:arXiv.org:1407.0347  [pdf] - 845006
DAMIC at SNOLAB
Comments: 13 pages, 12 figures, proceedings prepared for 13th International Conference on Topics in Astroparticle and Underground Physics (TAUP2013)
Submitted: 2014-06-30
We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of energy calibrations from 0.3 keVee to 60 keVee, showing that the CCD is a fully active detector with uniform energy response throughout the silicon target, good resolution (Fano ~0.16), and remarkable linear response to electron energy depositions. We show the capability of the CCD to localize the depth of particle interactions within the silicon target. We discuss the mode of operation and unique imaging capabilities of the CCD, and how they may be exploited to characterize and suppress backgrounds. We present the first results from the deployment of 250 um thick CCDs in SNOLAB, a prototype for the upcoming DAMIC100. DAMIC100 will have a target mass of 0.1 kg and should be able to directly test the CDMS-Si signal within a year of operation.
[13]  oai:arXiv.org:1310.6688  [pdf] - 737451
DAMIC: a novel dark matter experiment
Comments: 4 pages, 6 figures, ICRC2013
Submitted: 2013-10-24
DAMIC (Dark Matter in CCDs) is a novel dark matter experiment that has unique sensitivity to dark matter particles with masses below 10 GeV. Due to its low electronic readout noise (R.M.S. ~3 e-) this instrument is able to reach a detection threshold below 0.5 keV nuclear recoil energy, making the search for dark matter particles with low masses possible. We report on early results and experience gained from a detector that has been running at SNOLAB from Dec 2012. We also discuss the measured and expected backgrounds and present the plan for future detectors to be installed in 2014.