Normalized to: Harnden,, F.
[1]
oai:arXiv.org:astro-ph/0410136 [pdf] - 554559
Chandra Orion Ultradeep Project: Observations and Source Lists
Getman, K. V.;
Flaccomio, E.;
Broos, P. S.;
Grosso, N.;
Tsujimoto, M.;
Townsley, L.;
Garmire, G. P.;
Kastner, J.;
Li, J.;
Harnden,, F. R.;
Wolk, S.;
Murray, S. S.;
Lada, C. J.;
Muench, A. A.;
McCaughrean, M. J.;
Meeus, G.;
Damiani, F.;
Micela, G.;
Sciortino, S.;
Bally, J.;
Hillenbrand, L. A.;
Herbst, W.;
Preibisch, T.;
Feigelson, E. D.
Submitted: 2004-10-05
We present a description of the data reduction methods and the derived
catalog of more than 1600 X-ray point sources from the exceptionally deep
January 2003 Chandra X-ray Observatory observation of the Orion Nebula Cluster
and embedded populations around OMC-1. The observation was obtained with
Chandra's Advanced CCD Imaging Spectrometer (ACIS) and has been nicknamed the
Chandra Orion Ultradeep Project (COUP). With an 838 ks exposure made over a
continuous period of 13.2 days, the COUP observation provides the most uniform
and comprehensive dataset on the X-ray emission of normal stars ever obtained
in the history of X-ray astronomy.
[2]
oai:arXiv.org:astro-ph/0405580 [pdf] - 554550
X-ray spectroscopy of the unsteady quiescent corona of AD Leo with
Chandra
Submitted: 2004-05-28
We present the analysis and interpretation of an observation of the flare
star AD Leo (dM3e) with Chandra/LETG. The high resolution X-ray spectrum
allowed us to infer the plasma emission measure distribution (EMD) vs.
temperature, and the abundances of individual elements in the corona of this
magnetically-active star, during a typical state characterized by significant
variability but no large flaring event. We have also measured plasma densities
at various temperatures using spectroscopic diagnostics provided by He-like
triplets and Fe XXI lines. We show that the present EMD is similar to those
previously obtained from EUVE spectra during quiescent and flaring states,
confirming the long-term stability of the corona of AD Leo. At variance with
the case of other active stars, the EMD of AD Leo is characterized by a
significantly shallower slope, compatible with that predicted by static models
of isobaric loops with constant cross-section and uniform heating. We discuss
such coronal modeling to infer the average properties of the corona in terms of
loop populations, including estimates of the surface filling factor. We also
show that the EMD is compatible with the model of a corona continuously heated
by flares. The coronal composition is such that the element abundances,
relative to solar values, tend to increase with the First Ionization Potential,
with few exceptions. The line to continuum ratios suggest a nearly solar
coronal metallicity.
[3]
oai:arXiv.org:astro-ph/0308492 [pdf] - 554542
Chandra Multi-wavelength Project (ChaMP). I. First X-ray Source Catalog
Kim, D. -W.;
Cameron, R. A.;
Drake, J. J.;
Evans, N. R.;
Freeman, P.;
Gaetz, T. J.;
Ghosh, H.;
Green, P. J.;
Harnden,, F. R.;
Karovska, M.;
Kashyap, V.;
Maksym, P. W.;
Ratzlaff, P. W.;
Schlegel, E. M.;
Silverman, J. D.;
Tananbaum, H. D.;
Vikhlinin, A. A.;
Wilkes, B. J.;
Grimes, J. P.
Submitted: 2003-08-27
The Chandra Multi-wavelength Project (ChaMP) is a wide-area (~14 deg^2)
survey of serendipitous Chandra X-ray sources, aiming to establish fair
statistical samples covering a wide range of characteristics (such as absorbed
AGNs, high z clusters of galaxies) at flux levels (fX ~ 10^-15 - 10^-14 erg
sec-1 cm-2) intermediate between the Chandra Deep surveys and previous
missions. We present the first ChaMP catalog, which consists of 991 near
on-axis, bright X-ray sources obtained from the initial sample of 62
observations. The data have been uniformly reduced and analyzed with techniques
specifically developed for the ChaMP and then validated by visual examination.
To assess source reliability and positional uncertainty, we perform a series of
simulations and also use Chandra data to complement the simulation study. The
false source detection rate is found to be as good as or better than expected
for a given limiting threshold. On the other hand, the chance of missing a real
source is rather complex, depending on the source counts, off-axis distance (or
PSF), and background rate. The positional error (95% confidence level) is
usually < 1" for a bright source, regardless of its off-axis distance while it
can be as large as 4" for a weak source (~20 counts) at a large off-axis
distance (Doff-axis > 8'). We have also developed new methods to find spatially
extended or temporary variable sources and those sources are listed in the
catalog.
[4]
oai:arXiv.org:astro-ph/0308493 [pdf] - 554543
Chandra Multi-wavelength Project (ChaMP). II. First Results of X-ray
Source Properties
Kim, D. -W.;
Wilkes, B. J.;
Green, P. J.;
Cameron, R. A.;
Drake, J. J.;
Evans, N. R.;
Freeman, P.;
Gaetz, T. J.;
Ghosh, H.;
Harnden,, F. R.;
Karovska, M.;
Kashyap, V.;
Maksym, P. W.;
Ratzlaff, P. W.;
Schlegel, E. M.;
Silverman, J. D.;
Tananbaum, H. D.;
Vikhlinin, A. A.
Submitted: 2003-08-27
We present the first results of ChaMP X-ray source properties obtained from
the initial sample of 62 observations. The data have been uniformly reduced and
analyzed with techniques specifically developed for the ChaMP and then
validated by visual examination. Utilizing only near on-axis, bright X-ray
sources (to avoid problems caused by incompleteness and the Eddington bias), we
derive the Log(N)-Log(S) relation in soft (0.5-2 keV) and hard (2-8 keV) energy
bands. The ChaMP data are consistent with previous results of ROSAT, ASCA and
Chandra deep surveys. In particular, our data nicely fill in the flux gap in
the hard band between the Chandra Deep Field data and the previous ASCA data.
We check whether there is any systematic difference in the source density
between cluster and non-cluster fields and also search for field-to-field
variations, both of which have been previously reported. We found no
significant field-to-field cosmic variation in either test within the
statistics (~1 sigma) across the flux levels included in our sample. In the
X-ray color-color plot, most sources fall in the location characterized by
photon index = 1.5-2 and NH = a few x 10^20 cm^2, suggesting that they are
typical broad-line AGNs. There also exist a considerable number of sources with
peculiar X-ray colors (e.g., highly absorbed, very hard, very soft). We confirm
a trend that on average the X-ray color hardens as the count rate decreases.
Since the hardening is confined to the softest energy band (0.3-0.9 keV), we
conclude it is most likely due to absorption. We cross-correlate the X-ray
sources with other catalogs and describe their properties in terms of optical
color, X-ray-to-optical luminosity ratio and X-ray colors.