Normalized to: Hans, O.
[1]
oai:arXiv.org:1809.10376 [pdf] - 1795793
Multiple Star Systems in the Orion Nebula
GRAVITY collaboration;
Karl, Martina;
Pfuhl, Oliver;
Eisenhauer, Frank;
Genzel, Reinhard;
Grellmann, Rebekka;
Habibi, Maryam;
Abuter, Roberto;
Accardo, Matteo;
Amorim, António;
Anugu, Narsireddy;
Ávila, Gerardo;
Benisty, Myriam;
Berger, Jean-Philippe;
Bland, Nicolas;
Bonnet, Henri;
Bourget, Pierre;
Brandner, Wolfgang;
Brast, Roland;
Buron, Alexander;
Garatti, Alessio Caratti o;
Chapron, Frédéric;
Clénet, Yann;
Collin, Claude;
Foresto, Vincent Coudé du;
de Wit, Willem-Jan;
de Zeeuw, Tim;
Deen, Casey;
Delplancke-Ströbele, Françoise;
Dembet, Roderick;
Derie, Frédéric;
Dexter, Jason;
Duvert, Gilles;
Ebert, Monica;
Eckart, Andreas;
Esselborn, Michael;
Fédou, Pierre;
Finger, Gert;
Garcia, Paulo;
Dabo, Cesar Enrique Garcia;
Lopez, Rebeca Garcia;
Gao, Feng;
Gandron, Éric;
Gillessen, Stefan;
Gonté, Frédéric;
Gordo, Paulo;
Grözinger, Ulrich;
Guajardo, Patricia;
Guieu, Sylvain;
Haguenauer, Pierre;
Hans, Oliver;
Haubois, Xavier;
Haug, Marcus;
Haußmann, Frank;
Henning, Thomas;
Hippler, Stefan;
Horrobin, Matthew;
Huber, Armin;
Hubert, Zoltan;
Hubin, Norbert;
Hummel, Christian A.;
Jakob, Gerd;
Jochum, Lieselotte;
Jocou, Laurent;
Kaufer, Andreas;
Kellner, Stefan;
Kandrew, Sarah;
Kern, Lothar;
Kervella, Pierre;
Kiekebusch, Mario;
Klein, Ralf;
Köhler, Rainer;
Kolb, Johan;
Kulas, Martin;
Lacour, Sylvestre;
Lapeyrère, Vincent;
Lazareff, Bernard;
Bouquin, Jean-Baptiste Le;
Léna, Pierre;
Lenzen, Rainer;
Lévêque, Samuel;
Lin, Chien-Cheng;
Lippa, Magdalena;
Magnard, Yves;
Mehrgan, Leander;
Mérand, Antoine;
Moulin, Thibaut;
Müller, Eric;
Müller, Friedrich;
Neumann, Udo;
Oberti, Sylvain;
Ott, Thomas;
Pallanca, Laurent;
Panduro, Johana;
Pasquini, Luca;
Paumard, Thibaut;
Percheron, Isabelle;
Perraut, Karine;
Perrin, Guy;
Pflüger, Andreas;
Duc, Thanh Phan;
Plewa, Philipp M.;
Popovic, Dan;
Rabien, Sebastian;
Ramírez, Andrés;
Ramos, Jose;
Rau, Christian;
Riquelme, Miguel;
Rodríguez-Coira, Gustavo;
Rohloff, Ralf-Rainer;
Rosales, Alejandra;
Rousset, Gérard;
Sanchez-Bermudez, Joel;
Scheithauer, Silvia;
Schöller, Markus;
Schuhler, Nicolas;
Spyromilio, Jason;
Straub, Odele;
Straubmeier, Christian;
Sturm, Eckhard;
Suarez, Marcos;
Tristram, Konrad R. W.;
Ventura, Noel;
Vincent, Frédéric;
Waisberg, Idel;
Wank, Imke;
Widmann, Felix;
Wieprecht, Ekkehard;
Wiest, Michael;
Wiezorrek, Erich;
Wittkowski, Markus;
Woillez, Julien;
Wolff, Burkhard;
Yazici, Senol;
Ziegler, Denis;
Zins, Gérard
Submitted: 2018-09-27
This work presents an interferometric study of the massive-binary fraction in
the Orion Trapezium Cluster with the recently comissioned GRAVITY instrument.
We observe a total of 16 stars of mainly OB spectral type. We find three
previously unknown companions for $\theta ^1$ Ori B, $\theta ^2$ Ori B, and
$\theta ^2$ Ori C. We determine a separation for the previously suspected
companion of NU Ori. We confirm four companions for $\theta ^1$ Ori A, $\theta
^1$ Ori C, $\theta ^1$ Ori D, and $\theta ^2$ Ori A, all with substantially
improved astrometry and photometric mass estimates. We refine the orbit of the
eccentric high-mass binary $\theta ^1$ Ori C and we are able to derive a new
orbit for $\theta ^1$ Ori D. We find a system mass of 21.7 $M_{\odot}$ and a
period of $53$ days. Together with other previously detected companions seen in
spectroscopy or direct imaging, eleven of the 16 high-mass stars are multiple
systems. We obtain a total number of 22 companions with separations up to 600
AU. The companion fraction of the early B and O stars in our sample is about 2,
significantly higher than in earlier studies of mostly OB associations. The
separation distribution hints towards a bimodality. Such a bimodality has been
previously found in A stars, but rarely in OB binaries, which up to this point
have been assumed to be mostly compact with a tail of wider companions. We also
do not find a substantial population of equal-mass binaries. The observed
distribution of mass ratios declines steeply with mass, and like the direct
star counts, indicates that our companions follow a standard power law initial
mass function. Again, this is in contrast to earlier findings of flat mass
ratio distributions in OB associations. We exclude collision as a dominant
formation mechanism but find no clear preference for core accretion or
competitive accretion.
[2]
oai:arXiv.org:1705.02345 [pdf] - 1583163
First Light for GRAVITY: Phase Referencing Optical Interferometry for
the Very Large Telescope Interferometer
GRAVITY Collaboration;
Abuter, R.;
Accardo, M.;
Amorim, A.;
Anugu, N.;
Ávila, G.;
Azouaoui, N.;
Benisty, M.;
Berger, J. P.;
Blind, N.;
Bonnet, H.;
Bourget, P.;
Brandner, W.;
Brast, R.;
Buron, A.;
Burtscher, L.;
Cassaing, F.;
Chapron, F.;
Choquet, É.;
Clénet, Y.;
Collin, C.;
Foresto, V. Coudé du;
de Wit, W.;
de Zeeuw, P. T.;
Deen, C.;
Delplancke-Ströbele, F.;
Dembet, R.;
Derie, F.;
Dexter, J.;
Duvert, G.;
Ebert, M.;
Eckart, A.;
Eisenhauer, F.;
Esselborn, M.;
Fédou, P.;
Finger, G.;
Garcia, P.;
Dabo, C. E. Garcia;
Lopez, R. Garcia;
Gendron, E.;
Genzel, R.;
Gillessen, S.;
Gonte, F.;
Gordo, P.;
Grould, M.;
Grözinger, U.;
Guieu, S.;
Haguenauer, P.;
Hans, O.;
Haubois, X.;
Haug, M.;
Haussmann, F.;
Henning, Th.;
Hippler, S.;
Horrobin, M.;
Huber, A.;
Hubert, Z.;
Hubin, N.;
Hummel, C. A.;
Jakob, G.;
Janssen, A.;
Jochum, L.;
Jocou, L.;
Kaufer, A.;
Kellner, S.;
Kern, L.;
Kervella, P.;
Kiekebusch, M.;
Klein, R.;
Kok, Y.;
Kolb, J.;
Kulas, M.;
Lacour, S.;
Lapeyrère, V.;
Lazareff, B.;
Bouquin, J. -B. Le;
Lèna, P.;
Lenzen, R.;
Lévêque, S.;
Lippa, M.;
Magnard, Y.;
Mehrgan, L.;
Mellein, M.;
Mérand, A.;
Moreno-Ventas, J.;
Moulin, T.;
Müller, E.;
Müller, F.;
Neumann, U.;
Oberti, S.;
Ott, T.;
Pallanca, L.;
Panduro, J.;
Pasquini, L.;
Paumard, T.;
Percheron, I.;
Perraut, K.;
Perrin, G.;
Pflüger, A.;
Pfuhl, O.;
Duc, T. Phan;
Plewa, P. M.;
Popovic, D.;
Rabien, S.;
Ramírez, A.;
Ramos, J.;
Rau, C.;
Riquelme, M.;
Rohloff, R. -R.;
Rousset, G.;
Sanchez-Bermudez, J.;
Scheithauer, S.;
Schöller, M.;
Schuhler, N.;
Spyromilio, J.;
Straubmeier, C.;
Sturm, E.;
Suarez, M.;
Tristram, K. R. W.;
Ventura, N.;
Vincent, F.;
Waisberg, I.;
Wank, I.;
Weber, J.;
Wieprecht, E.;
Wiest, M.;
Wiezorrek, E.;
Wittkowski, M.;
Woillez, J.;
Wolff, B.;
Yazici, S.;
Ziegler, D.;
Zins, G.
Submitted: 2017-05-05
GRAVITY is a new instrument to coherently combine the light of the European
Southern Observatory Very Large Telescope Interferometer to form a telescope
with an equivalent 130 m diameter angular resolution and a collecting area of
200 m$^2$. The instrument comprises fiber fed integrated optics beam
combination, high resolution spectroscopy, built-in beam analysis and control,
near-infrared wavefront sensing, phase-tracking, dual beam operation and laser
metrology [...]. This article gives an overview of GRAVITY and reports on the
performance and the first astronomical observations during commissioning in
2015/16. We demonstrate phase tracking on stars as faint as m$_K$ ~ 10 mag,
phase-referenced interferometry of objects fainter than m$_K$ ~ 15 mag with a
limiting magnitude of m$_K$ ~ 17 mag, minute long coherent integrations, a
visibility accuracy of better than 0.25 %, and spectro-differential phase and
closure phase accuracy better than 0.5{\deg}, corresponding to a differential
astrometric precision of better than 10 microarcseconds ({\mu}as). The
dual-beam astrometry, measuring the phase difference of two objects with laser
metrology, is still under commissioning. First observations show residuals as
low as 50 {\mu}as when following objects over several months. We illustrate the
instrument performance with the observations of archetypical objects for the
different instrument modes. Examples include the Galactic Center supermassive
black hole and its fast orbiting star S2 for phase referenced dual beam
observations and infrared wavefront sensing, the High Mass X-Ray Binary BP Cru
and the Active Galactic Nucleus of PDS 456 for few {\mu}as spectro-differential
astrometry, the T Tauri star S CrA for a spectro-differential visibility
analysis, {\xi} Tel and 24 Cap for high accuracy visibility observations, and
{\eta} Car for interferometric imaging with GRAVITY.
[3]
oai:arXiv.org:1608.04888 [pdf] - 1458639
The metrology system of the VLTI instrument GRAVITY
Lippa, Magdalena;
Gillessen, Stefan;
Blind, Nicolas;
Kok, Yipting;
Yazici, Senol;
Weber, Johannes;
Pfuhl, Oliver;
Haug, Marcus;
Kellner, Stefan;
Wieprecht, Ekkehard;
Eisenhauer, Frank;
Genzel, Reinhard;
Hans, Oliver;
Haussmann, Frank;
Huber, David;
Kratschmann, Tobias;
Ott, Thomas;
Plattner, Markus;
Rau, Christian;
Sturm, Eckhard;
Waisberg, Idel;
Wiezorrek, Erich;
Perrin, Guy;
Perraut, Karine;
Brandner, Wolfgang;
Straubmeier, Christian;
Amorim, Antonio
Submitted: 2016-08-17
The VLTI instrument GRAVITY combines the beams from four telescopes and
provides phase-referenced imaging as well as precision-astrometry of order 10
microarcseconds by observing two celestial objects in dual-field mode. Their
angular separation can be determined from their differential OPD (dOPD) when
the internal dOPDs in the interferometer are known. Here, we present the
general overview of the novel metrology system which performs these
measurements. The metrology consists of a three-beam laser system and a
homodyne detection scheme for three-beam interference using phase-shifting
interferometry in combination with lock-in amplifiers. Via this approach the
metrology system measures dOPDs on a nanometer-level.
[4]
oai:arXiv.org:1503.07303 [pdf] - 970999
GRAVITY: the VLTI 4-beam combiner for narrow-angle astrometry and
interferometric imaging
Blind, N.;
Eisenhauer, F.;
Gillessen, S.;
Kok, Y.;
Lippa, M.;
Perrin, G.;
Dembet, R.;
Fedou, P.;
Lacour, S.;
Perraut, K.;
Jocou, L.;
Burtscher, L.;
Hans, O.;
Haug, M.;
Haussmann, F.;
Huber, S.;
Janssen, A.;
Kellner, S.;
Ott, T.;
Pfuhl, O.;
Sturm, E.;
Weber, J.;
Wieprecht, E.;
Amorim, A.;
Brandner, W.;
Straubmeier, C.
Submitted: 2015-03-25
GRAVITY is the second generation Very Large Telescope Interferometer
instrument for precision narrow-angle astrometry and interferometric imaging in
the Near Infra-Red (NIR). It shall provide precision astrometry of order 10
microarcseconds, and imaging capability at a few milliarcsecond resolution, and
hence will revolutionise dynamical measurements of celestial objects. GRAVITY
is currently in the last stages of its integration and tests in Garching at
MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present
here the instrument, with a particular focus on the components making use of
fibres: integrated optics beam combiners, polarisation rotators, fibre
differential delay lines, and the metrology.
[5]
oai:arXiv.org:1501.05822 [pdf] - 925683
The GRAVITY instrument software / High-level software
Burtscher, Leonard;
Wieprecht, Ekkehard;
Ott, Thomas;
Kok, Yitping;
Yazici, Senol;
Anugu, Narsireddy;
Dembet, Roderick;
Fedou, Pierre;
Lacour, Sylvestre;
Ott, Juergen;
Paumard, Thibaut;
Lapeyrere, Vincent;
Kervella, Pierre;
Abuter, Roberto;
Pozna, Eszter;
Eisenhauer, Frank;
Blind, Nicolas;
Genzel, Reinhard;
Gillessen, Stefan;
Hans, Oliver;
Haug, Marcus;
Haussmann, Frank;
Kellner, Stefan;
Lippa, Magdalena;
Pfuhl, Oliver;
Sturm, Eckhard;
Weber, Johannes;
Amorim, Antonio;
Brandner, Wolfgang;
Rousselet-Perraut, Karine;
Perrin, Guy S.;
Straubmeier, Christian;
Schoeller, Markus
Submitted: 2015-01-23
GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking,
astrometric and imaging instrument for the Very Large Telescope Interferometer
(VLTI). It is requiring the development of one of the most complex instrument
software systems ever built for an ESO instrument. Apart from its many
interfaces and interdependencies, one of the most challenging aspects is the
overall performance and stability of this complex system. The three infrared
detectors and the fast reflective memory network (RMN) recorder contribute a
total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data
per night. The detectors, the two instrument Local Control Units (LCUs) as well
as the five LCUs running applications under TAC (Tools for Advanced Control)
architecture, are interconnected with fast Ethernet, RMN fibers and dedicated
fiber connections as well as signals for the time synchronization. Here we give
a simplified overview of all subsystems of GRAVITY and their interfaces and
discuss two examples of high-level applications during observations: the
acquisition procedure and the gathering and merging of data to the final FITS
file.
[6]
oai:arXiv.org:1501.04738 [pdf] - 923534
The GRAVITY metrology system: narrow-angle astrometry via phase-shifting
interferometry
Lippa, M.;
Blind, N.;
Gillessen, S.;
Kok, Y.;
Weber, J.;
Eisenhauer, F.;
Pfuhl, O.;
Janssen, A.;
Haug, M.;
Haußmann, F.;
Kellner, S.;
Hans, O.;
Wieprecht, E.;
Ott, T.;
Burtscher, L.;
Genzel, R.;
Sturm, E.;
Hofmann, R.;
Huber, S.;
Huber, D.;
Senftleben, S.;
Pflüger, A.;
Greßmann, R.;
Perrin, G.;
Perraut, K.;
Brandner, W.;
Straubmeier, C.;
Amorim, A.;
Schöller, M.
Submitted: 2015-01-20
The VLTI instrument GRAVITY will provide very powerful astrometry by
combining the light from four telescopes for two objects simultaneously. It
will measure the angular separation between the two astronomical objects to a
precision of 10 microarcseconds. This corresponds to a differential optical
path difference (dOPD) between the targets of few nanometers and the paths
within the interferometer have to be maintained stable to that level. For this
purpose, the novel metrology system of GRAVITY will monitor the internal dOPDs
by means of phase-shifting interferometry. We present the four-step
phase-shifting concept of the metrology with emphasis on the method used for
calibrating the phase shifts. The latter is based on a phase-step insensitive
algorithm which unambiguously extracts phases in contrast to other methods that
are strongly limited by non-linearities of the phase-shifting device. The main
constraint of this algorithm is to introduce a robust ellipse fitting routine.
Via this approach we are able to measure phase shifts in the laboratory with a
typical accuracy of lambda/2000 or 1 nanometer of the metrology wavelength.
[7]
oai:arXiv.org:1412.1696 [pdf] - 904702
The fiber coupler and beam stabilization system of the GRAVITY
interferometer
Pfuhl, O.;
Haug, M.;
Eisenhauer, F.;
Kellner, S.;
Haussmann, F.;
Perrin, G.;
Gillessen, S.;
Straubmeier, C.;
Ott, T.;
Rousselet-Perraut, K.;
Amorim, A.;
Lippa, M.;
Janssen, A.;
Brandner, W.;
Kok, Y.;
Blind, N.;
Burtscher, L.;
Sturm, E.;
Wieprecht, E.;
Schoeller, M.;
Weber, J.;
Hans, O.;
Huber, S.
Submitted: 2014-12-04
We present the installed and fully operational beam stabilization and fiber
injection subsystem feeding the 2nd generation VLTI instrument GRAVITY. The
interferometer GRAVITY requires an unprecedented stability of the VLTI optical
train to achieve micro-arcsecond astrometry. For this purpose, GRAVITY contains
four fiber coupler units, one per telescope. Each unit is equipped with
actuators to stabilize the telescope beam in terms of tilt and lateral pupil
displacement, to rotate the field, to adjust the polarization and to compensate
atmospheric piston. A special roof-prism offers the possibility of on-axis as
well as off-axis fringe tracking without changing the optical train. We
describe the assembly, integration and alignment and the resulting optical
quality and performance of the individual units. Finally, we present the
closed-loop performance of the tip-tilt and pupil tracking achieved with the
final systems in the lab.
[8]
oai:arXiv.org:1407.6669 [pdf] - 861906
The GRAVITY metrology system: modeling a metrology in optical fibers
Blind, N.;
Huber, H.;
Eisenhauer, F.;
Weber, J.;
Gillessen, S.;
Lippa, M.;
Burtscher, L.;
Hans, O.;
Haug, M.;
Haussmann, F.;
Huber, S.;
Janssen, A.;
Kellner, S.;
Kok, Y.;
Ott, T.;
Pfuhl, O.;
Sturm, E.;
Wieprecht, E.;
Amorim, A.;
Brandner, W.;
Perrin, G.;
Perraut, K.;
Straubmeier, C.
Submitted: 2014-07-24
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for
high-precision narrow-angle astrometry and phase-referenced interferometric
imaging. The laser metrology system of GRAVITY is at the heart of its
astrometric mode, which must measure the distance of 2 stars with a precision
of 10 micro-arcseconds. This means the metrology has to measure the optical
path difference between the two beam combiners of GRAVITY to a level of 5 nm.
The metrology design presents some non-common paths that have consequently to
be stable at a level of 1 nm. Otherwise they would impact the performance of
GRAVITY. The various tests we made in the past on the prototype give us hints
on the components responsible for this error, and on their respective
contribution to the total error. It is however difficult to assess their exact
origin from only OPD measurements, and therefore, to propose a solution to this
problem. In this paper, we present the results of a semi-empirical modeling of
the fibered metrology system, relying on theoretical basis, as well as on
characterisations of key components. The modeling of the metrology system
regarding various effects, e.g., temperature, waveguide heating or mechanical
stress, will help us to understand how the metrology behave. The goals of this
modeling are to 1) model the test set-ups and reproduce the measurements (as a
validation of the modeling), 2) determine the origin of the non-common path
errors, and 3) propose modifications to the current metrology design to reach
the required 1nm stability.
[9]
oai:arXiv.org:1407.6660 [pdf] - 861905
GRAVITY: the Calibration Unit
Blind, N.;
Eisenhauer, F.;
Haug, M.;
Gillessen, S.;
Lippa, M.;
Burtscher, L.;
Hans, O.;
Haussmann, F.;
Huber, S.;
Janssen, A.;
Kellner, S.;
Kok, Y.;
Ott, T.;
Pfuhl, O.;
Sturm, E.;
Weber, J.;
Wieprecht, E.;
Amorim, A.;
Brandner, W.;
Perrin, G.;
Perraut, K.;
Straubmeier, C.
Submitted: 2014-07-24
We present in this paper the design and characterisation of a new sub-system
of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The
Calibration Unit provides all functions to test and calibrate the beam combiner
instrument: it creates two artificial stars on four beams, and dispose of four
delay lines with an internal metrology. It also includes artificial stars for
the tip-tilt and pupil guiding systems, as well as four metrology pick-up
diodes, for tests and calibration of the corresponding sub-systems. The
calibration unit also hosts the reference targets to align GRAVITY to the VLTI,
and the safety shutters to avoid the metrology light to propagate in the
VLTI-lab. We present the results of the characterisation and validtion of these
differrent sub-units.