Hannawald, M.
Normalized to: Hannawald, M.
4 article(s) in total. 51 co-authors, from 1 to 4 common article(s). Median position in authors list is 24,0.
[1]
oai:arXiv.org:1006.3098 [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark
Matter searches
Kozlov, V. Yu.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X. -F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number
of low count rate experiments, namely direct searches for Dark Matter. In this
work we describe a neutron detector to measure this background in an
underground laboratory, the Laboratoire Souterrain de Modane. The system is
based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of
the EDELWEISS-II experiment for coincident muon detection. The system was
installed in autumn 2008 and passed since then a number of commissioning tests
proving its full functionality. The data-taking is continuously ongoing and a
count rate of the order of 1 muon-induced neutron per day has been achieved.
[2]
oai:arXiv.org:1001.4383 [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Rozov, S.;
Armengaud, E.;
Augier, C.;
Bergé, L.;
Benoit, A.;
Besida, O.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Defay, X.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrach, C.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M-A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the
LSM underground laboratory in proximity of the EDELWEISS-II dark matter search
experiment together with short measurements at various other locations.
Monitoring of the flux of thermal neutrons is accomplished using a mobile
detection system with low background proportional counter filled with $^3$He.
On average 75 neutrons per day are detected with a background level below 1
count per day (cpd). This provides a unique possibility of a day by day study
of variations of the neutron field in a deep underground site. The measured
average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is
$\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We
report the first experimental observation that the point-to-point thermal
neutron flux at LSM varies by more than a factor two.
[3]
oai:arXiv.org:0912.0805 [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic
detectors with interleaved electrodes
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X-F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.;
Collaboration, the EDELWEISS
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark
matter with an array of ten 400 g heat-and-ionization cryogenic detectors
equipped with interleaved electrodes for the rejection of near-surface events.
Six months of continuous operation at the Laboratoire Souterrain de Modane have
been achieved. The observation of one nuclear recoil candidate above 20 keV in
an effective exposure of 144 kgd is interpreted in terms of limits on the
cross-section of spin-independent interactions of WIMPs and nucleons. A
cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80
GeV/c2. This result demonstrates for the first time the very high background
rejection capabilities of these simple and robust detectors in an actual WIMP
search experiment.
[4]
oai:arXiv.org:0905.0753 [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Broniatowski, A.;
Defay, X.;
Armengaud, E.;
Berge, L.;
Benoit, A.;
Besida, O.;
Blumer, J.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrache, C.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M. -A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is
presented, taking advantage of the coplanar grid technique of event
localisation for improved background discrimination. Experiments performed with
prototype devices in the EDELWEISS II setup at the Modane underground facility
demonstrate the remarkably high efficiency of these devices for the rejection
of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate
the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as
proposed in the EURECA project of a one-ton cryogenic detector mass.