Normalized to: Hancock, B.
[1]
oai:arXiv.org:1612.03506 [pdf] - 1533243
The calibration of read-out-streak photometry in the XMM-Newton Optical
Monitor and the construction of a bright-source catalogue
Page, M. J.;
Chan, N.;
Breeveld, A. A.;
Talavera, A.;
Yershov, V.;
Kennedy, T.;
Kuin, N. P. M.;
Hancock, B.;
Smith, P. J.;
Carter, M.
Submitted: 2016-12-11
The dynamic range of the XMM-Newton Optical Monitor (XMM-OM) is limited at
the bright end by coincidence loss, the superposition of multiple photons in
the individual frames recorded from its micro-channel-plate (MCP) intensified
charge-coupled device (CCD) detector. One way to overcome this limitation is to
use photons that arrive during the frame transfer of the CCD, forming vertical
read-out streaks for bright sources. We calibrate these read-out streaks for
photometry of bright sources observed with XMM-OM. The bright source limit for
read-out streak photometry is set by the recharge time of the MCPs. For XMM-OM
we find that the MCP recharge time is 0.55 ms. We determine that the effective
bright limits for read-out streak photometry with XMM-OM are approximately 1.5
magnitudes brighter than the bright source limits for normal aperture
photometry in full-frame images. This translates into bright-source limits in
Vega magnitudes of UVW2=7.1, UVM2=8.0, UVW1=9.4, U=10.5, B=11.5, V=10.2 and
White=12.5 for data taken early in the mission. The limits brighten by up to
0.2 magnitudes, depending on filter, over the course of the mission as the
detector ages. The method is demonstrated by deriving UVW1 photometry for the
symbiotic nova RR Telescopii, and the new photometry is used to constrain the
e-folding time of its decaying UV emission. Using the read-out streak method,
we obtain photometry for 50 per cent of the missing UV source measurements in
version 2.1 of the XMM-Newton Serendipitous UV Source Survey (XMM-SUSS 2.1)
catalogue.
[2]
oai:arXiv.org:1309.4816 [pdf] - 1179345
The use and calibration of read-out streaks to increase the dynamic
range of the Swift Ultraviolet/Optical Telescope
Page, M. J.;
Kuin, N. P. M.;
Breeveld, A. A.;
Hancock, B.;
Holland, S. T.;
Marshall, F. E.;
Oates, S.;
Roming, P. W. A.;
Siegel, M. H.;
Smith, P. J.;
Carter, M.;
De Pasquale, M.;
Symeonidis, M.;
Yershov, V.;
Beardmore, A. P.
Submitted: 2013-09-18
The dynamic range of photon counting micro-channel-plate (MCP) intensified
charged-coupled device (CCD) instruments such as the Swift Ultraviolet/Optical
Telescope (UVOT) and the XMM-Newton Optical Monitor (XMM-OM) is limited at the
bright end by coincidence loss, the superposition of multiple photons in the
individual frames recorded by the CCD. Photons which arrive during the brief
period in which the image frame is transferred for read out of the CCD are
displaced in the transfer direction in the recorded images. For sufficiently
bright sources, these displaced counts form read-out streaks. Using UVOT
observations of Tycho-2 stars, we investigate the use of these read-out streaks
to obtain photometry for sources which are too bright (and hence have too much
coincidence loss) for normal aperture photometry to be reliable. For
read-out-streak photometry, the bright-source limiting factor is coincidence
loss within the MCPs rather than the CCD. We find that photometric measurements
can be obtained for stars up to 2.4 magnitudes brighter than the usual
full-frame coincidence-loss limit by using the read-out streaks. The resulting
bright-limit Vega magnitudes in the UVOT passbands are UVW2=8.80, UVM2=8.27,
UVW1=8.86, u=9.76, b=10.53, v=9.31 and White=11.71; these limits are
independent of the windowing mode of the camera. We find that a photometric
precision of 0.1 mag can be achieved through read-out streak measurements. A
suitable method for the measurement of read-out streaks is described and all
necessary calibration factors are given.
[3]
oai:arXiv.org:1004.2448 [pdf] - 222203
Paper II: Calibration of the Swift ultraviolet/optical telescope
Breeveld, A. A.;
Curran, P. A.;
Hoversten, E. A.;
Koch, S.;
Landsman, W.;
Marshall, F. E.;
Page, M. J.;
Poole, T. S.;
Roming, P.;
Smith, P. J.;
Still, M.;
Yershov, V.;
Blustin, A. J.;
Brown, P. J.;
Gronwall, C.;
Holland, S. T.;
Kuin, N. P. M.;
McGowan, K.;
Rosen, S.;
Boyd, P.;
Broos, P.;
Carter, M.;
Chester, M. M.;
Hancock, B.;
Huckle, H.;
Immler, S.;
Ivanushkina, M.;
Kennedy, T.;
Mason, K. O.;
Morgan, A. N.;
Oates, S.;
de Pasquale, M.;
Schady, P.;
Siegel, M.;
Berk, D. Vanden
Submitted: 2010-04-14
The Ultraviolet/Optical Telescope (UVOT) is one of three instruments onboard
the Swift observatory. The photometric calibration has been published, and this
paper follows up with details on other aspects of the calibration including a
measurement of the point spread function with an assessment of the orbital
variation and the effect on photometry. A correction for large scale variations
in sensitivity over the field of view is described, as well as a model of the
coincidence loss which is used to assess the coincidence correction in extended
regions. We have provided a correction for the detector distortion and measured
the resulting internal astrometric accuracy of the UVOT, also giving the
absolute accuracy with respect to the International Celestial Reference System.
We have compiled statistics on the background count rates, and discuss the
sources of the background, including instrumental scattered light. In each case
we describe any impact on UVOT measurements, whether any correction is applied
in the standard pipeline data processing or whether further steps are
recommended.
[4]
oai:arXiv.org:0708.2259 [pdf] - 254895
Photometric Calibration of the Swift Ultraviolet/Optical Telescope
Poole, T. S.;
Breeveld, A. A.;
Page, M. J.;
Landsman, W.;
Holland, S. T.;
Roming, P.;
Kuin, N. P. M.;
Brown, P. J.;
Gronwall, C.;
Hunsberger, S.;
Koch, S.;
Mason, K. O.;
Schady, P.;
Berk, D. Vanden;
Blustin, A. J.;
Boyd, P.;
Broos, P.;
Carter, M.;
Chester, M. M.;
Cucchiara, A.;
Hancock, B.;
Huckle, H.;
Immler, S.;
Ivanushkina, M.;
Kennedy, T.;
Marshall, F.;
Morgan, A.;
Pandey, S.;
de Pasquale, M.;
Smith, P. J.;
Still, M.
Submitted: 2007-08-16, last modified: 2007-11-09
We present the photometric calibration of the Swift UltraViolet/Optical
Telescope (UVOT) which includes: optimum photometric and background apertures,
effective area curves, colour transformations, conversion factors for count
rates to flux, and the photometric zero points (which are accurate to better
than 4 per cent) for each of the seven UVOT broadband filters. The calibration
was performed with observations of standard stars and standard star fields that
represent a wide range of spectral star types. The calibration results include
the position dependent uniformity, and instrument response over the 1600-8000A
operational range. Because the UVOT is a photon counting instrument, we also
discuss the effect of coincidence loss on the calibration results. We provide
practical guidelines for using the calibration in UVOT data analysis. The
results presented here supersede previous calibration results.
[5]
oai:arXiv.org:astro-ph/0507413 [pdf] - 386220
The Swift Ultra-Violet/Optical Telescope
Roming, P. W. A.;
Kennedy, T. E.;
Mason, K. O.;
Nousek, J. A.;
Ahr, L.;
Bingham, R. E.;
Broos, P. S.;
Carter, M. J.;
Hancock, B. K.;
Huckle, H. E.;
Hunsberger, S. D.;
Kawakami, H.;
Killough, R.;
Koch, T. S.;
McLelland, M. K.;
Smith, K.;
Smith, P. J.;
Soto, J. C.;
Boyd, P. T.;
Breeveld, A. A.;
Holland, S. T.;
Ivanushkina, M.;
Pryzby, M. S.;
Still, M. D.;
Stock, J.
Submitted: 2005-07-18
The UV/Optical Telescope (UVOT) is one of three instruments flying aboard the
Swift Gamma-ray Observatory. It is designed to capture the early (approximately
1 minute) UV and optical photons from the afterglow of gamma-ray bursts in the
170-600 nm band as well as long term observations of these afterglows. This is
accomplished through the use of UV and optical broadband filters and grisms.
The UVOT has a modified Ritchey-Chretien design with micro-channel plate
intensified charged-coupled device detectors that record the arrival time of
individual photons and provide sub-arcsecond positioning of sources. We discuss
some of the science to be pursued by the UVOT and the overall design of the
instrument.