sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Hamal, Petr

Normalized to: Hamal, P.

4 article(s) in total. 79 co-authors, from 1 to 4 common article(s). Median position in authors list is 13,0.

[1]  oai:arXiv.org:1911.05285  [pdf] - 2054070
The First Full-Scale Prototypes of the Fluorescence detector Array of Single-pixel Telescopes
Comments: 26 pages, 23 figures
Submitted: 2019-11-12
The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design concept for a next-generation UHECR observatory, addressing the requirements for a large-area, low-cost detector suitable for measuring the properties of ultra-high energy cosmic rays (UHECRs), having energies exceeding $10^{19.5}$\,eV, with an unprecedented aperture. We have developed a full-scale prototype consisting of four 200\,mm diameter photo-multiplier tubes at the focus of a segmented mirror of 1.6\,m in diameter. In October 2016, September 2017, and September 2018 we installed three such prototypes at the Black Rock Mesa site of the Telescope Array experiment in central Utah, USA. All three telescopes have been steadily taking data since installation. We report on the design and installation of these prototypes, and present some preliminary results, including measurements of artificial light sources, distant ultraviolet lasers, and UHECRs. Furthermore, we discuss some additional uses for these simplified low-cost fluorescence telescopes, including the facilitation of a systematic comparison of the transparency of the atmosphere above the Telescope Array experiment and the Pierre Auger Observatory, a study of the systematic uncertainty associated with the existing fluorescence detectors of these two experiments, and a cross-calibration of their energy and $X_{\text{max}}$ scales.
[2]  oai:arXiv.org:1908.06860  [pdf] - 1945116
Calibration and operation of SiPM-based cameras for gamma-ray astronomy in presence of high night-sky light
Comments:
Submitted: 2019-08-19
The next generation of Cherenkov telescope cameras feature Silicon Photo Multipliers (SiPM), which can guarantee excellent performance and allow for observation also under moonlight, increasing duty-cycle and therefore the physics reach. A 4 m-diameter Davies-Cotton prototype telescope with a 9-degree optical FoV and a 1296-pixel SiPM camera, has been designed to meet the requirements of the next generation of ground-based gamma-ray observatories at the highest energies. The large-scale production of the telescopes for array deployment has required the development of a fully automated calibration strategy which relies on a dedicated hardware, the Camera Test Setup (CTS). For each camera pixel, the CTS is equipped with two LEDs, one operated in pulsed mode to reproduce signal and one in continuous mode to reproduce night-sky background. In this contribution we will present the camera calibration strategy, from the laboratory measurement to the on-site monitoring with emphasis on the results obtained with the first camera prototype. In addition, key performances such as charge resolution, time resolution and trigger efficiencies and their degradation with increasing night-sky background level will be presented.
[3]  oai:arXiv.org:1908.02904  [pdf] - 1931542
Observing ultra-high energy cosmic rays with prototypes of the Fluorescence detector Array of Single-pixel Telescopes (FAST) in both hemispheres
Comments: 8 pages, Proceedings of the 36th International Cosmic Ray Conference (ICRC 2019), July 24th - August 1st, 2019, Madison, WI, USA. arXiv admin note: text overlap with arXiv:1810.06678
Submitted: 2019-08-07
The origin and nature of ultra-high energy cosmic rays (UHECRs) are hot topics in the astroparticle physics community. The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design for a next-generation ground-based UHECR observatory, addressing the requirements for a large-area, low-cost detector suitable for measuring the properties of the highest energy cosmic rays with an unprecedented aperture. We have developed a full-scale prototype consisting of four 200 mm photomultiplier tubes at the focus of a segmented mirror of 1.6 m in diameter. Over the last three years, we have installed three prototypes at the Telescope Array Experiment in Utah, USA. These telescopes have been steadily taking data since installation. We report on preliminary results of the full-scale FAST prototypes, including measurements of UHECRs, and distant ultra-violet lasers used to study the atmospheric transparency. Furthermore, we discuss the installation of an additional identical FAST prototype at the Pierre Auger Observatory in Argentina. Possible benefits to the Telescope Array Experiment and the Pierre Auger Observatory include a comparison of the transparency of the atmosphere above both experiments, a study of the systematic uncertainty associated with their existing fluorescence detectors, and a cross-calibration of their energy and Xmax scales.
[4]  oai:arXiv.org:1907.08061  [pdf] - 1918999
Monte Carlo study of a single SST-1M prototype for the Cherenkov Telescope Array
Comments: 8 pages, 13 figures, ICRC 2019 proceeding
Submitted: 2019-07-18
The SST-1M telescope was developed as a prototype of a Small-Size-Telescope for the Cherenkov Telescope Array observatory and it has been extensively tested in Krakow since 2017. In this contribution we present validation of the Monte Carlo model of the prototype and expected performance in Krakow conditions. We focus on gamma/hadron separation and mono reconstruction of energy and gamma photon arrival direction using Machine learning methods.