Normalized to: Hamal, P.
[1]
oai:arXiv.org:1911.05285 [pdf] - 2054070
The First Full-Scale Prototypes of the Fluorescence detector Array of
Single-pixel Telescopes
Malacari, M.;
Farmer, J.;
Fujii, T.;
Albury, J.;
Bellido, J. A.;
Chytka, L.;
Hamal, P.;
Horvath, P.;
Hrabovsky, M.;
Mandat, D.;
Matthews, J. N.;
Nozka, L.;
Palatka, M.;
Pech, M.;
Privitera, P.;
Schovanek, P.;
Smida, R.;
Thomas, S. B.;
Travnicek, P.
Submitted: 2019-11-12
The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design
concept for a next-generation UHECR observatory, addressing the requirements
for a large-area, low-cost detector suitable for measuring the properties of
ultra-high energy cosmic rays (UHECRs), having energies exceeding
$10^{19.5}$\,eV, with an unprecedented aperture. We have developed a full-scale
prototype consisting of four 200\,mm diameter photo-multiplier tubes at the
focus of a segmented mirror of 1.6\,m in diameter. In October 2016, September
2017, and September 2018 we installed three such prototypes at the Black Rock
Mesa site of the Telescope Array experiment in central Utah, USA. All three
telescopes have been steadily taking data since installation. We report on the
design and installation of these prototypes, and present some preliminary
results, including measurements of artificial light sources, distant
ultraviolet lasers, and UHECRs. Furthermore, we discuss some additional uses
for these simplified low-cost fluorescence telescopes, including the
facilitation of a systematic comparison of the transparency of the atmosphere
above the Telescope Array experiment and the Pierre Auger Observatory, a study
of the systematic uncertainty associated with the existing fluorescence
detectors of these two experiments, and a cross-calibration of their energy and
$X_{\text{max}}$ scales.
[2]
oai:arXiv.org:1908.06860 [pdf] - 1945116
Calibration and operation of SiPM-based cameras for gamma-ray astronomy
in presence of high night-sky light
Samarai, Imen Al;
Alispach, Cyril Martin;
Balbo, Matteo;
Barbano, Anastasia Maria;
Beshley, Vasyl;
Biland, Adrian;
Blazek, Jiri;
Błocki, Jacek;
Borkowski, Jerzy;
Bulik, Tomek;
Cadoux, Frank Raphael;
Chytka, Ladislav;
Coco, Victor;
De Angelis, Nicolas;
Della Volpe, Domenico;
Favre, Yannick;
Gieras, Tomasz;
Grudzińska, Mira;
Hamal, Petr;
Heller, Matthieu;
Hrabovsky, Miroslav;
Juryšek, Jakub;
Kasperek, Jerzy;
Koncewicz, Katarzyna;
Kotarba, Andrzej;
Lyard, Étienne;
Mach, Emil;
Mandat, Dusan;
Michal, Stanislav;
Michałowski, Jerzy;
Moderski, Rafal;
Montaruli, Teresa;
Nagai, Andrii;
Neise, Dominik;
Niemiec, Jacek;
Ekoume, Theodore Rodrigue Njoh;
Ostrowski, Michal;
Palatka, Miroslav;
Paśko, Paweł;
Pech, Miroslav;
Pilszyk, Bartłomiej;
Przybilski, Henry;
Rajda, Paweł;
Renier, Yves;
Rozwadowski, Paweł;
Schovanek, Petr;
Seweryn, Karol;
Sliusar, Vitali;
Smakulska, Dorota;
Sobczyńska, Dorota;
Stawarz, Łukasz;
Świerblewski, Jacek;
Świerk, Paweł;
Travnicek, Petr;
Pujadas, Isaac Troyano;
Walter, Roland;
Wiecek, Marek;
Zagdański, Aleksander;
Ziȩtara, Krzysztof
Submitted: 2019-08-19
The next generation of Cherenkov telescope cameras feature Silicon Photo
Multipliers (SiPM), which can guarantee excellent performance and allow for
observation also under moonlight, increasing duty-cycle and therefore the
physics reach. A 4 m-diameter Davies-Cotton prototype telescope with a 9-degree
optical FoV and a 1296-pixel SiPM camera, has been designed to meet the
requirements of the next generation of ground-based gamma-ray observatories at
the highest energies.
The large-scale production of the telescopes for array deployment has
required the development of a fully automated calibration strategy which relies
on a dedicated hardware, the Camera Test Setup (CTS). For each camera pixel,
the CTS is equipped with two LEDs, one operated in pulsed mode to reproduce
signal and one in continuous mode to reproduce night-sky background.
In this contribution we will present the camera calibration strategy, from
the laboratory measurement to the on-site monitoring with emphasis on the
results obtained with the first camera prototype. In addition, key performances
such as charge resolution, time resolution and trigger efficiencies and their
degradation with increasing night-sky background level will be presented.
[3]
oai:arXiv.org:1908.02904 [pdf] - 1931542
Observing ultra-high energy cosmic rays with prototypes of the
Fluorescence detector Array of Single-pixel Telescopes (FAST) in both
hemispheres
Fujii, Toshihiro;
Malacari, Max;
Farmer, John;
Albury, Justin;
Bellido, Jose A.;
Chytka, Ladislav;
Hamal, Petr;
Horvath, Pavel;
Hrabovsky, Miroslav;
Kvita, Jiri;
Mandat, Dusan;
Mastrodicasa, Massimo;
Matthews, John N.;
Michal, Stanislav;
Ni, Xiaochen;
Nozka, Libor;
Palatka, Miroslav;
Pech, Miroslav;
Privitera, Paolo;
Schovanek, Petr;
Salamida, Francesco;
Smida, Radomir;
Thomas, Stan B.;
Travnicek, Petr;
Vacula, Martin
Submitted: 2019-08-07
The origin and nature of ultra-high energy cosmic rays (UHECRs) are hot
topics in the astroparticle physics community. The Fluorescence detector Array
of Single-pixel Telescopes (FAST) is a design for a next-generation
ground-based UHECR observatory, addressing the requirements for a large-area,
low-cost detector suitable for measuring the properties of the highest energy
cosmic rays with an unprecedented aperture. We have developed a full-scale
prototype consisting of four 200 mm photomultiplier tubes at the focus of a
segmented mirror of 1.6 m in diameter. Over the last three years, we have
installed three prototypes at the Telescope Array Experiment in Utah, USA.
These telescopes have been steadily taking data since installation. We report
on preliminary results of the full-scale FAST prototypes, including
measurements of UHECRs, and distant ultra-violet lasers used to study the
atmospheric transparency. Furthermore, we discuss the installation of an
additional identical FAST prototype at the Pierre Auger Observatory in
Argentina. Possible benefits to the Telescope Array Experiment and the Pierre
Auger Observatory include a comparison of the transparency of the atmosphere
above both experiments, a study of the systematic uncertainty associated with
their existing fluorescence detectors, and a cross-calibration of their energy
and Xmax scales.
[4]
oai:arXiv.org:1907.08061 [pdf] - 1918999
Monte Carlo study of a single SST-1M prototype for the Cherenkov
Telescope Array
Jurysek, Jakub;
Samarai, Imen Al;
Alispach, Cyril;
Balbo, Matteo;
Barbano, Anastasia Maria;
Beshley, Vasyl;
Biland, Adrian;
Blazek, Jiri;
Błocki, Jacek;
Borkowski, Jerzy;
Bulik, Tomek;
Cadoux, Frank Raphael;
Chytka, Ladislav;
Coco, Victor;
De Angelis, Nicolas;
Della Volpe, Domenico;
Favre, Yannick;
Gieras, Tomasz;
Grudzińska, Mira;
Hamal, Petr;
Heller, Mathieu;
Hrabovsky, Miroslav;
Kasperek, Jerzy;
Koncewicz, Katarzyna;
Kotarba, Andrzej;
Lyard, Etienne;
Mach, Emil;
Mandat, Dusan;
Michal, Stanislav;
Michalowski, Jerzy;
Moderski, Rafal;
Montaruli, Teresa;
Nagai, Andrii;
Neise, Dominik;
Niemiec, Jacek;
Ekoume, Theodore Rodrigue Njoh;
Ostrowski, Michal;
Palatka, Miroslav;
Pasko, Pawel;
Pech, Miroslav;
Pilszyk, Bartłomiej;
Przybilski, Henry;
Rajda, Pawel;
Renier, Yves;
Rozwadowski, Paweł;
Schovanek, Petr;
Seweryn, K.;
Sliusar, Vitalii;
Smakulska, Dorota;
Sobczyńska, Dorota;
Stawarz, Łukasz;
Świerblewski, Jacek;
Świerk, Paweł;
Travnicek, Petr;
Pujadas, Isaac Troyano;
Walter, Roland;
Wiecek, Marek;
Zagdański, Aleksander;
Zietara, Krzystof
Submitted: 2019-07-18
The SST-1M telescope was developed as a prototype of a Small-Size-Telescope
for the Cherenkov Telescope Array observatory and it has been extensively
tested in Krakow since 2017. In this contribution we present validation of the
Monte Carlo model of the prototype and expected performance in Krakow
conditions. We focus on gamma/hadron separation and mono reconstruction of
energy and gamma photon arrival direction using Machine learning methods.