Normalized to: Haller, C.
[1]
oai:arXiv.org:1403.5747 [pdf] - 903425
Calibration and performance of the photon sensor response of FACT -- The
First G-APD Cherenkov telescope
Biland, A.;
Bretz, T.;
Buß, J.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Freiwald, J.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hempfling, C.;
Hildebrand, D.;
Hughes, G.;
Horisberger, U.;
Knoetig, M. L.;
Krähenbühl, T.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meier, K.;
Mueller, S.;
Neise, D.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Rhode, W.;
Röser, U.;
Stucki, J. -P.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Vogler, P.;
Walter, R.;
Weitzel, Q.
Submitted: 2014-03-23, last modified: 2014-07-30
The First G-APD Cherenkov Telescope (FACT) is the first in-operation test of
the performance of silicon photo detectors in Cherenkov Astronomy. For more
than two years it is operated on La Palma, Canary Islands (Spain), for the
purpose of long-term monitoring of astrophysical sources. For this, the
performance of the photo detectors is crucial and therefore has been studied in
great detail. Special care has been taken for their temperature and voltage
dependence implementing a correction method to keep their properties stable.
Several measurements have been carried out to monitor the performance. The
measurements and their results are shown, demonstrating the stability of the
gain below the percent level. The resulting stability of the whole system is
discussed, nicely demonstrating that silicon photo detectors are perfectly
suited for the usage in Cherenkov telescopes, especially for long-term
monitoring purpose.
[2]
oai:arXiv.org:1407.1988 [pdf] - 1516230
FACT -- Operation of the First G-APD Cherenkov Telescope
Bretz, T.;
Biland, A.;
Buß, J.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Freiwald, J.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hempfling, C.;
Hildebrand, D.;
Hughes, G.;
Horisberger, U.;
Knoetig, M. L.;
Krähenbühl, T.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meier, K.;
Mueller, S.;
Neise, D.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Rhode, W.;
Röser, U.;
Stucki, J. -P.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Vogler, P.;
Walter, R.;
Weitzel, Q.
Submitted: 2014-07-08
Since more than two years, the First G-APD Cherenkov Telescope (FACT) is
operating successfully at the Canary Island of La Palma. Apart from its purpose
to serve as a monitoring facility for the brightest TeV blazars, it was built
as a major step to establish solid state photon counters as detectors in
Cherenkov astronomy.
The camera of the First G-APD Cherenkov Telesope comprises 1440 Geiger-mode
avalanche photo diodes (G-APD aka. MPPC or SiPM) for photon detection. Since
properties as the gain of G-APDs depend on temperature and the applied voltage,
a real-time feedback system has been developed and implemented. To correct for
the change introduced by temperature, several sensors have been placed close to
the photon detectors. Their read out is used to calculate a corresponding
voltage offset. In addition to temperature changes, changing current introduces
a voltage drop in the supporting resistor network. To correct changes in the
voltage drop introduced by varying photon flux from the night-sky background,
the current is measured and the voltage drop calculated. To check the stability
of the G-APD properties, dark count spectra with high statistics have been
taken under different environmental conditions and been evaluated.
The maximum data rate delivered by the camera is about 240 MB/s. The recorded
data, which can exceed 1 TB in a moonless night, is compressed in real-time
with a proprietary loss-less algorithm. The performance is better than gzip by
almost a factor of two in compression ratio and speed. In total, two to three
CPU cores are needed for data taking. In parallel, a quick-look analysis of the
recently recorded data is executed on a second machine. Its result is publicly
available within a few minutes after the data were taken.
[...]
[3]
oai:arXiv.org:1403.3573 [pdf] - 797027
FACT -- The G-APD revolution in Cherenkov astronomy
Bretz, T.;
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Buß, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hempfling, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. S.;
Knoetig, M. L.;
Köhne, J. H.;
Krähenbühl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Müuller, S.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Röser, U.;
Stucki, J. P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zänglein, M.
Submitted: 2014-03-14
Since two years, the FACT telescope is operating on the Canary Island of La
Palma. Apart from its purpose to serve as a monitoring facility for the
brightest TeV blazars, it was built as a major step to establish solid state
photon counters as detectors in Cherenkov astronomy. The camera of the First
G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes
(G-APD), equipped with solid light guides to increase the effective light
collection area of each sensor. Since no sense-line is available, a special
challenge is to keep the applied voltage stable although the current drawn by
the G-APD depends on the flux of night-sky background photons significantly
varying with ambient light conditions. Methods have been developed to keep the
temperature and voltage dependent response of the G-APDs stable during
operation. As a cross-check, dark count spectra with high statistics have been
taken under different environmental conditions. In this presentation, the
project, the developed methods and the experience from two years of operation
of the first G-APD based camera in Cherenkov astronomy under changing
environmental conditions will be presented.
[4]
oai:arXiv.org:1308.1512 [pdf] - 1934965
FACT - The First G-APD Cherenkov Telescope: Status and Results
Bretz, T.;
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buss, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
Koehne, J. -H.;
Kraehenbuehl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Roeser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zaenglein, M.
Submitted: 2013-08-07
The First G-APD Cherenkov telescope (FACT) is the first telescope using
silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the
HEGRA CT3 telescope, still located at the Observatorio del Roque de los
Muchachos, and it is successfully in operation since Oct. 2011. The use of
Silicon devices promises a higher photon detection efficiency, more robustness
and higher precision than photo-multiplier tubes. The FACT collaboration is
investigating with which precision these devices can be operated on the
long-term. Currently, the telescope is successfully operated from remote and
robotic operation is under development. During the past months of operation,
the foreseen monitoring program of the brightest known TeV blazars has been
carried out, and first physics results have been obtained including a strong
flare of Mrk501. An instantaneous flare alert system is already in a testing
phase. This presentation will give an overview of the project and summarize its
goals, status and first results.
[5]
oai:arXiv.org:1307.7892 [pdf] - 699793
FACT: Towards Robotic Operation of an Imaging Air Cherenkov Telescope
Biland, A.;
Anderhub, H.;
Backes, M.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buss, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
Koehne, J. -H.;
Kraehenbuehl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Roeser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zaenglein, M.
Submitted: 2013-07-30
The First G-APD Cherenkov Telescope (FACT) became operational at La Palma in
October 2011. Since summer 2012, due to very smooth and stable operation, it is
the first telescope of its kind that is routinely operated from remote, without
the need for a data-taking crew on site. In addition, many standard tasks of
operation are executed automatically without the need for manual interaction.
Based on the experience gained so far, some alterations to improve the safety
of the system are under development to allow robotic operation in the future.
We present the setup and precautions used to implement remote operations and
the experience gained so far, as well as the work towards robotic operation.
[6]
oai:arXiv.org:1304.1710 [pdf] - 680263
Design and Operation of FACT -- The First G-APD Cherenkov Telescope
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buß, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
K"ohne, J. H.;
Kr"ahenb"uhl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
R"oser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Z"anglein, M.
Submitted: 2013-04-05
The First G-APD Cherenkov Telescope (FACT) is designed to detect cosmic
gamma-rays with energies from several hundred GeV up to about 10 TeV using the
Imaging Atmospheric Cherenkov Technique. In contrast to former or existing
telescopes, the camera of the FACT telescope is comprised of solid-state
Geiger-mode Avalanche Photodiodes (G-APD) instead of photomultiplier tubes for
photo detection. It is the first full-scale device of its kind employing this
new technology. The telescope is operated at the Observatorio del Roque de los
Muchachos (La Palma, Canary Islands, Spain) since fall 2011. This paper
describes in detail the design, construction and operation of the system,
including hardware and software aspects. Technical experiences gained after one
year of operation are discussed and conclusions with regard to future projects
are drawn.
[7]
oai:arXiv.org:1006.5335 [pdf] - 297292
The ArDM experiment
ArDM Collaboration;
Amsler, C.;
Badertscher, A.;
Boccone, V.;
Bourgeois, N.;
Bueno, A.;
Carmona-Benitez, M. C.;
Chorowski, M.;
Creus, W.;
Curioni, A.;
Daw, E.;
Degunda, U.;
Dell'Antone, A.;
Droge, M.;
Epprecht, L.;
Haller, C.;
Haranczyk, M.;
Horikawa, S.;
Kaufmann, L.;
Kisiel, J.;
Knecht, L.;
Laffranchi, M.;
Lagoda, J.;
Lazzaro, C.;
Lightfoot, P.;
Lozano, J.;
Lussi, D.;
Maire, G.;
Mania, S.;
Marchionni, A.;
Mavrokoridis, K.;
Melgarejo, A.;
Mijakowski, P.;
Natterer, G.;
Navas-Concha, S.;
Otiougova, P.;
Piotrowska, A.;
Polinski, J.;
de Prado, M.;
Przewlocki, P.;
Ravat, S.;
Regenfus, C.;
Resnati, F.;
Robinson, M.;
Rochet, J.;
Romero, L.;
Rondio, E.;
Rubbia, A.;
Scotto-Lavina, L.;
Spooner, N.;
Viant, T.;
Trawinski, A.;
Ulbricht, J.;
Zalewska, A.
Submitted: 2010-06-28
The aim of the ArDM project is the development and operation of a one ton
double-phase liquid argon detector for direct Dark Matter searches. The
detector measures both the scintillation light and the ionization charge from
ionizing radiation using two independent readout systems. This paper briefly
describes the detector concept and presents preliminary results from the ArDM
R&D program, including a 3 l prototype developed to test the charge readout
system.